Instruction manual DD606BK Instruction manual DD606BK
16 17
Please keep this instruction manual for future reference Please keep this instruction manual for future reference
CLEANING THE EXTRACTOR
Careful maintenance helps to ensure the correct operation and good performance over time.
CAUTION
The hood must be disconnected from the electrical network, both by unplugging the appliance
from the socket and activating the magnetic circuit breaker (safety cut-out), before removing the
metal grease filters. After cleaning, replace the metal grease filters as outlined in the installation
instructions.
MAINTENANCE HOW TO PROCEED? ACCESSORY PRODUCTS TO USE
External surfaces and
accessories
Do not use metallic scrubbers,
abrasive products, or hard brushes.
To clean the external surfaces of the cooker hood
and the light housing screen use only commercially
avail-able household detergents diluted in water.
Then rinse with clean water and dry with a soft
cloth.
Grease filter with
extractable unit open
After 30 hours of operation, the
downdraft will signal the grease filter
saturation.
The saturation is signalled by the
blinking of the 4 central LED’s.
To reset, hold down the timer button
13
Careful maintenance helps to ensure the correct operation and good performance over time.
MAINTENANCE HOW TO PROCEED? ADDITIONAL PRODUCTS TO
USE
External surfaces and
accessories
Do not use metallic scrubbers,
abrasive products or hard brushes.
To clean the external surfaces of the
cooker hood and the light housing
screen use only commercially avail-
able household detergents diluted
in water. Then rinse with clean
water and dry with a soft cloth.
Grease filter with
extractable unit open
After 30 hours of operation,
the downdraft will signal the grease
filter saturation.
The saturation is signaled by the
blinking of the 4 central leds.To
reset, hold down the timer button
for at least 3 seconds, while the
carriage is open.
The grease filters can be washed by
hand or in the dishwasher. These
filters need to be cleaned on a
regular basis, because otherwise
they may represent a fire risk.
Refit the grease filters and
front panel, making sure that the
panel is properly fitted at the sides,
otherwise it may cause the
downdraft to stop operating.
Active charcoal filter
In the recirculation mode, the
active charcoal filter must be
replaced periodically. To remove the
charcoal filter first of all it is
necessary to remove the grease
filter and then pull the plastic key
of the panel itself, in order to
disengage it from its seating.
Follow these steps in reverse order to
insert the active charcoal filter.
Replace the used charcoal filter on
an average of every six months.
Cleaning the extractor
CAUTION
The hood must be disconnected from the electrical network, both by unplugging the appliance from
the socket and activating the magnetic circuit breaker (safety cut-out), before removing the metal
grease filters. After cleaning, replace the metal grease filters as outlined in the installation
instructions.
for at least 3 seconds, while the
carriage is open.
The grease filters can be washed by hand or in
the dishwasher. These filters need to be cleaned
on a regular basis, because otherwise they may
represent a fire risk.
Refit the grease filters and front panel, making
sure that the panel is properly fitted at the sides,
otherwise it may cause the downdraft to stop
operating.
Active charcoal filter In the recirculation mode, the active
charcoal filter must be replaced
periodically.
To remove the charcoal filter first
remove the grease filter and then pull
the plastic key of the panel itself, in
order to disengage it from its seating.
Follow these steps in reverse order to
insert the active charcoal filter.
Replace the used charcoal filter on an
average of every six months.
TROUBLESHOOTING
PROBLEM SOLUTION
The downdraft does not work Check that:
»There is not a power outage.
»A specific speed has actually been selected.
»The red reset key, found over the electrical system box, is pushed.
»Make sure that the wires of the 9 pole connection are inserted
properly in the connector itself (during the connection phase, an
excessive pressure could bend the contacts).
The downdraft has low performance Check that:
»The motor speed selected is sufficient for the quantity of fumes and
vapours present in the room.
»The kitchen is ventilated well enough to allow air for intake.
»The charcoal filter is not worn out. (Filtering version cooker hood).
»The air outlet channel is free and compliant with paragraph no.2.
»The non-return valves of the suctioning unit are free to rotate.
The downdraft stops in the middle of
operation.
Check that:
»There is not a power outage.
»The omnipolar device has not tripped.