Instruction manual Oi363
Please keep this instruction manual for future reference
9
tubes (Fig. 7.4 & Fig. 7.5) from above the two structures by making them come
down to the appropriate hoodseat. Lift the hood together with the structure and
the extension tubes to make the four springs (Fig. 7.6) hook to the slots (Fig.
7.3-C). Then tighten the two elements securely (Fig. 6.1 & Fig. 6.2) with the safety
screws (Fig. 6.2-A) and connect the hood tube to the drain hole. Make the electrical
connections. (For versions with display only) Lift the lower pipe until the cable
strap coming out of the extraction unit is uncovered and connect it to the display
cable strap. Put down the lower pipe while paying attention it is being properly
introduced into the hood.
Lift the upper tube (Fig. 7.5) up to the ceiling and insert the two self-tapping screws
(Fig. 7.5-D).
Recirculation mode
Place the upper plate (Fig.5.1) on the ceiling. Drill 4 holes, 8 mm each, just next to
the slots. Insert the plastic dowels into the holes (Fig.5.1- A). Fix the baffle (Fig. 5.2)
to the upper bracket (Fig.5.3) with the four self tapping screws provided (Fig. 5.3
A). Screw up the plate together with the baffle (Fig.5.1 B). Then fasten the lower
structure (Fig. 7.2) on the hood by making its holes and the metric thread screws
welded on the fan support coincide (Fig. 7.1). Insert the washers and nuts provided
(Fig. 7.2-A) and screw with an appropriate tool. Connect the drainpipe to the power
unit nozzle and fix securely with a hose clamp. Insert the upper structure (Fig. 7.3)
into the lowest one and adjust its height as required by matching it with the cooking
top’s minimum height. Tighten the two structures securely with the screws provided
(Fig. 7.3-B). Insert the two extension tubes (Fig. 7.4 & Fig. 7.5) from above the two
structures by making them come down to the appropriate hood seat. Lift the hood
together with the structure and the extension tubes to make the four springs (Fig.
7.6) hook to the slots (Fig. 7.3-C). Then tighten the two elements securely (Fig. 6.1 &
Fig. 6.2) with the safety screws (Fig. 6.2-A) and connect the hood tube to the baffle’s
lower hole. Make the electrical connections. (For versions with display only) Lift the
lower pipe until the cable strap coming out of the extraction unit is uncovered and
connect it to the display cable strap. Put down the lower pipe while paying attention
it is being properly introduced into the hood. Lift the upper tube (Fig. 7.5) up to the
ceiling and insert the two self-tapping screws (Fig. 7.5-D).
WARNING:
Before connecting the flexible exhausting pipe to the motor, make sure the stop
valve, which is on the air outlet of the motor, can swing.
OI363_Instruction manual.indd 9 04/04/2018 13:58