Carepeutic KH317 User manual

Joint Relaxation Heated Vibration Massager
Knee and Joint Physiotherapy Unit
Instruction Manual
Model: KH317

Knee and Joint Physiotherapy Unit
___________________________________________________________________________
_______________________________________
By Carepeutic®
2
*** Keep this manual for future reference ***
READAND SAVE IMPORTANT SAFETY INSTRUCTIONS
Read the following safety information carefully before using this product. If you have any
medical conditions (such as pacemaker and pregnant) or are undergoing medical treatment or
surgery, we advise that you should consult with your doctor before use.
SAFETY NOTE:
Warning: This product does NOT have water-proof, do not immerse water. Do not use
this product under blankets or under other covers. This is NOT a toy.
Attention: This product is designed for private use, not intended for medical or
commercial purpose. Children should be supervised to ensure that they do not use this product
as a toy.
CAUTION:
•Do not immerse water in any circumstances.
•Do not use this massager in close proximity to fireplace. Care should be exercised near
open flame or with burning cigarettes.
•Do not use the product if you are hungry, right after meal, drunk, or right after
extreme exercise.
•Do not use the product if you have wound or are after surgery and not yet fully
recovered.
•Do not use this product continuously for more than 45 minutes at a time. The product
has default working time of 30 minutes. It'll automatically turn off when the time is
up. It is recommended that you should take 10 to 15 minutes break for every 30
minutes of use.
•Do not use this product while you are sleeping, and avoid falling asleep while the
product is in use.
•Always unplug the product from the wall outlet after use. Never leave this product
unattended while its power is connected.
•Never use the product close to heater, fireplace, stove or other heat source.
•Always escort and pay attention while children, patients, disabled and elderly people
are using this product. This product is not for children without adult supervision.
•Never use the product if the plug/wire/product is damaged, if it is not in a smooth
operation as it should be, or if it immerses water.
•Unauthorized person is not allowed to reconstruct or replace the component of this
product.

Knee and Joint Physiotherapy Unit
___________________________________________________________________________
_______________________________________
By Carepeutic®
3
•Do not use this product in sauna room or bathroom, or in area where has high
humidity.
•Close supervision is necessary when this product is used by, close or next to children,
invalids, or disabled person.
•Never let children, mental retarded and people with difficulty in action to operate this
product and to reach the power cord.
•If the product has not been used for a long time, check it before use again.
•Excessive use can lead to overheat and shorter product life. Should this occur, turn off
and unplug the power, and allow the product to cool down before use again.
•Do not use this product as a substitute for medical treatment.
•This product is designed for household use only.
MEDICAL NOTES:
1. To avoid excessive stimulation of skin, the massage time should not exceed the
recommended minutes at a time.
2. If you are under medical treatment and your doctor or orthopedist does not
particularly forbid massage, you can enjoy the massage following your doctor's
instruction.
3. A massage should never feel unpleasant. Should pain or discomfort result,
discontinue use and consult with your doctor.
4. Excessive massage can also have harm to body.
5. People who are unable to feel normal temperature, the ill persons undergoing medical
treatment and children should not use this product. If in doubt, talk to your doctor in
advance.
WARNING 一TO REDUCE RISK OF BURN, FIRE, ELECTRIC SHOCK, OR INJURY TO
USERS:
1. This product should never be left unattended when it is plugged in. Unplug from wall
outlet when it is not in use.
2. Close supervision is necessary when this product is used by or close to children,
invalids, or disabled persons. THIS PRODUCT IS NOTATOY.
3. Use this product only for its intended use as described in this manual.
4. Never operate this product if it has a damaged power cord or plug, if it is not working
properly, if it has been damaged on shell or immersed water. Return the product to
service center for examination and repair. Never try to take apart or repair this
product by yourselves.
5. Do not carry this product with its power cord or use the power cord as a handle.
6. Turn off the product on the control panel before removing plug from outlet. Do not
turn on the device during charging (if any).
7. Use only the original adaptor or charging cable that comes with the product.
8. Keep this product and its power cord away from fireplace or wet sources.
9. Always unplug the power cord from the wall outlet after using and before cleaning.
10. Do not use attachments that are not recommended by manufacturer for this product.

Knee and Joint Physiotherapy Unit
___________________________________________________________________________
_______________________________________
By Carepeutic®
4
NOTICE: this product should not be used in the following circumstances:
•Massage should be comfortable and pleasant. Should extreme pain result, discontinue
use and consult with your doctor.
•Avoid using an uncertified extension cord because the extension cord may lead to
overheat and risk of fire.
•This product should never be used by an individual with a medical condition that will
limit the user’s capability to operate the product.
•Never use this product if there is wound or injury on targeted area.
•Do not use this product after taking pain relief medications, sedatives or alcohol.
Consult with your doctor if you are under these circumstances.
•Do not use this product when you have insensitive skin in your targeted areas or in
the environment of poor air circulation. The unattended use of heat by children or
incapacitated persons may be dangerous.
•It is recommended not to use this product 30 minutes before or after your meal.
Product parts:
Magnets
Vibration
Massage
Tungsten
Lamp
Heating
Infrared Heat

Knee and Joint Physiotherapy Unit
___________________________________________________________________________
_______________________________________
By Carepeutic®
5
Parts/ accessories
ACAdaptor
AC power jack
On/Off switch for vibration
massager. (Left side underneath of
massager)
On/Off button for Heat
Function (Start/Stop)
Temperature control buttons +/-
Control panel
Straps
buckle

Knee and Joint Physiotherapy Unit
___________________________________________________________________________
_______________________________________
By Carepeutic®
6
Comfort padding cover
Straps: 2 straps for knee / elbow, 1 strap for shoulder
OPERATION GUIDE:
1. Put the Comfort Padding Cover on the target area (recommended if you are not
wearing comfortable dress).
2. Put the massager on the top of the Comfort Padding Cover with the control panel
facing up. Adjust the straps until it fits your girth of knee properly and have it
buckled.
3. For best performance, always attach the massager to the curve of knee as close as
possible.
4. Connect the AC power cable to AC Power Jack on massager, connect the AC adaptor
to power cable and plug into wall outlet.
5. The LED light on control panel is on, LED screen shows "--".
6. Infrared Therapy:
•To turn on Infrared Heat function, press Start/Stop button once on control
panel, Infrared Therapy starts working; LED screen shows 40℃(default
minimum temperature).
7. Warming Heat Therapy:
•Press UP or DOWN button to set your preferred temperature (maximum
65℃). Warming Light starts working; LED screen shows your preferred
temperature.
•Its thermostat-control system will control the heat level automatically. It'll
stop heating when it reaches your preset temperature and restart heating when
its temperature is lower than your preset temperature.
•Note: the GREEN indicator light will be on and off alternatively during
heating and off when the heating stops.

Knee and Joint Physiotherapy Unit
___________________________________________________________________________
_______________________________________
By Carepeutic®
7
8. If you do not want heat therapy, choose to have only infrared therapy, press DOWN
button to reduce temperature to its minimum level (40℃). And it'll work with only
infrared therapy.
9. To turn off Infrared Heat function, Press Start/Stop button once again on control
panel. LED screen shows "--".
10. Vibration Massage:
•Press the On/Off Switch to "-" or "o" position to turn On/Off vibration
massage.
•Note: On/Off Switch is located on the left side underneath the massager.
11. Infrared / Heat therapy and Vibration massage are independently controlled.
Turning On/Off either one of the 2 functions will not affect another function.
Temperature increment:
1. For temperature within 40℃to 55℃, the unit increment is 5℃every time you press
UP or DOWN button. From 56℃to 65℃, the unit increment is 1℃.
Timer:
1. The default time for infrared heat therapy is 30 minutes. It'll automatically shut off
after 30 minutes of use. You need to press Start/Stop button again on control panel if
you need more cycles.
2. There is not default time for vibration massage. You can turn On/Off the vibration
massage any time.
Automatic Heating Temperature Balancing System:
1. The device has built-in automatic heating temperature balancing system.
2. The heating system starts after you set up the temperature. During heating, the green
indicator light is on and off alternatively.
3. The heating system stops when the temperature reaches your preferred temperature
level, and the green indicator light is off.
4. The heating system starts again when its temperature is lower than your preferred
level, and the green indicator light is on and off again. This cycle will continue and so
on.
How to put on the massager:

Knee and Joint Physiotherapy Unit
___________________________________________________________________________
_______________________________________
By Carepeutic®
8
Attach to knee and buckle up Plug in power cord Turn on power
Suggestions for use:
For Knee For Shoulder For Elbow
1. Use it for a while before movement or going out, which will reduce the sense of pain
at knees and relieve muscle stiffness.
2. For better effect, it’s suggested to use it for 2 to 3 times every day with warm
temperature level (40℃), 30 minutes each time.
3. Warm temperature is the most proper temperature for users. It is not recommended to
set temperature to high level such as more than 55℃, especially not for new users .
4. Acute temperature change will discount the performance. Try to adjust the
temperature gradually.
5. Upon relief of the sense of pain, it’s suggested to conduct extensive gentle exercise by
continuously unbending and bending the knee joints for minutes, when you feel
comfortable.
6. Always wear comfortable dress and or use the Comfort Padding Cover included with
the product.
7. Excessive use of the massage may also discount the performance. Long time of direct
exposure to skin may result in burning injury or skin sensibility.

Knee and Joint Physiotherapy Unit
___________________________________________________________________________
_______________________________________
By Carepeutic®
9
Care and Maintenance
•This product has no waterproof. Do not immerse water.
•Before cleaning, you must turn off the device.
•Clean the product with a soft, damp towel. Never use strong abrasives, detergents or
cleaning agents for cleaning.
Storage:
•Turn off the device or unplug the power cord from the electrical outlet and allow
it to cool down.
•Place it in a clean, dry location.
•Do not drag or hang the unit with its power cord.
•This product is designed for household use only.
•Never put the product close to fireplace or other heating sources.
Features:
•Superconducting Acupressure massage for knees, elbow, and shoulder. Improve
muscle tissue stiffness. Relieve muscle tension and stimulate blood circulation.
•Equipped with both thermostat-regulated soothing heat therapy.
•Built-in magnets, providing gentle and comfortable magnetic therapy.
•With independent control vibration massage, provides soothing comfortable massage
for joint and muscle tension relief.
•Ergonomically designed cozy padded body, fit knees with girth of 20 inches or less.
With elastic and adjustable straps for knees and shoulder.
•Automatically shut off after 30 minutes of use (heat function only).
•Temperature control system: Heating system starts and stops automatically based on
the temperature preset.

Knee and Joint Physiotherapy Unit
___________________________________________________________________________
_______________________________________
By Carepeutic®
10
•Temperature auto balancing system: The device has built-in temperature balancing
function. Heating function on and off automatically based on your preset temperature
level.
•Soothing Heat Therapy: adjustable temperature, from 40° C - 65°C (113oF - 149oF).
•Vibration Massage and Infrared Heat Therapy work alone or simultaneously.
Specifications:
•Powered byAC adaptor 12V DC output (included).
•Power consumption: 20W
•Comes with 2 adjustable straps for knee, elbow and 1 adjustable strap for shoulder.
•With Comfort Padding Cover.
•Product size: 10x9x3 inches
•Product weight: 1.3 lbs
Troubleshooting:
Problem
Cause
Solutions
No power
AC not plugged in or default
working time is up
Check if AC is properly plugged into the
power jack. Auto shut off after 30 minutes
(for heating). Unplug the unit and turn it
on again.
Heating stops
working
Its default working time is 30
minutes.
The current temperature is lower
than its preset temperature level
Turn off the power and turn it on again.
Adjust its present temperature higher than
its default 40C (45C, 50C, etc)
Vibration
massage not
working
For vibration massage, its own
On/Off power switch is on the
left side underneath the control
panel.
Turn On the power switch for vibration
massage. Power switch for Heat and
Vibration are controlled separately.
Note: This product is not intended to diagnose, treat, cure, or prevent any disease.
Limited Warranty:
Please contact seller for warranty. Limited warranty from manufacturer only for original purchaser
against manufacturing or workmanship defect under normal use. Due to the hygiene or rehabilitation
nature of this product, it is non-returnable.
Carepeutic® is a registered trademark,
all rights reserved, © Q.L.M.
www.ideaTomorrow.com
Powered by Carepeutic® Global Lab
Conceptualized in USA
Other manuals for KH317
1
Table of contents
Other Carepeutic Massager manuals

Carepeutic
Carepeutic Mega Sport User manual

Carepeutic
Carepeutic KH329 User manual

Carepeutic
Carepeutic KH381 User manual

Carepeutic
Carepeutic KH254 User manual

Carepeutic
Carepeutic KH325 User manual

Carepeutic
Carepeutic KH298 User manual

Carepeutic
Carepeutic KH391 User manual

Carepeutic
Carepeutic KH261 User manual

Carepeutic
Carepeutic KH265 User manual

Carepeutic
Carepeutic KH317 User manual