manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CARLO GAVAZZI
  6. •
  7. Security Sensor
  8. •
  9. CARLO GAVAZZI RAD Series User manual

CARLO GAVAZZI RAD Series User manual

100 (3.937”)
40
(1.575”)
Minimum
Clearance
23
(0.905”)
Ø 8 (5/16”)
Ø 3 (1/8”)
Ø 3 (1/8”)
13
(0.511”)
Ceiling
Safety Notes
Inside View
Cover Removing
Red L D IR Receiver Green L D
Push Button
D C (-)
Push Button
INC (+)
Electrical Connections
Caution:
Power on the radar by Class2 or LV transformer.
Do not power on the radar until all primary and secondary wiring is completed.
Installation Tips
Fix firmly radar
sensor to the wall.
Avoid the presence
of moving objects
in radar sensing
field.
Not install panels or
metallic surfaces
close to the device.
Not install radar
on direct exposure
of rain.
Not install radar
close to fluorescent
lamp.
Drilling Plan mm (inches)
Mounting Instructions
Wall mounting. Ceiling mounting.
To install radar is necessary only a screwdriver and drill.
Detection Area Shape modifying instructions
To adjust the type of the sensing field and pattern, verify the following instructions:
RAD 01 To obtain wide pattern install the planar antenna in vertical mode, while to obtain narrow pattern
install the planar antenna in horizontal mode. Carefully remove the fixing tie clip with a screwdriver
and change the orientation mode of planar antenna.
CAUTION!
Power off the radar before removing the planar antenna.
The radar is an electrostatic sensitive device: proceed with caution to remove the planar antenna,
don’t wear synthetic clothes or rubber sole shoes.
Lateral angle rotation 0°
Lateral angle rotation 15°
Planar antenna
vertical angle
Sensing Field adjustment
Mechanical sensor orientation
Adjust the vertical position to obtain the vertical sensing field close or far from the door. Adjust the lateral position to obtain the desired lateral angle sensing field.
Planar antenna
vertical angle
Sensing field adjustment according to Sensitivity setting and mounting Height
The sensing field area size (lobo) depends on the sensitivity parameter setting and the radar mounting height.
Detection area vs Sensitivity value (vertical angle 45°).
Detection area vs Sensitivity value (vertical angle 15°).
RAD 02 Uni & Bidirectional ModelRAD 01 Bidirectional Model
Detection area vs Sensitivity value (vertical angle 45°); vertical mount mode.
Detection area vs Sensitivity value (vertical angle 45°); horizontal mount mode.
Planar
Antenna
Remove cover from behind, before installation.
After installation from the front side, insert the screwdriver in the provided slot.
RAD 01 To obtain wide pattern L1 install
the planar antenna in vertical mode.
RAD 01 To obtain narrow pattern L2 install
the planar antenna in horizontal mode.
RAD 02 To obtain narrow pattern L3 or L4.
Motion Radar Sensor is a digital uni or bidirectional
motion sensor for trouble-free opening of all types of
automatic doors (sliding, swinging, folding, revolving,
speed-doors, overhead doors, etc...), for pedestrian
and civil applications.
It can be adapted to every application without further
accessories and can be controlled by an infrared
remote controller. Mounting height up to 4m (13.12ft)
also available in uni- or bidirectional mode to detect
motion towards or away from the device. Like most of
other microwave detectors, equipped with planar flat
antenna, Carlo Gavazzi Radar activates automatic
doors utilizing doppler shift effect for detecting
movements.
MMoottiioonn RRaaddaarr SSeennssoorr
RRAADD SSeerriieess
CARLO GAVAZZI
Au t o m a t i o n C o m p o n e n t s
Cable inlet
Read Instructions!
Before working with this unit, read these instructions
carefully and completely. Make sure that you have
understood all the information!
Disconnect system from supply network
Before any installation, maintenance or modification
work:
Disconnect your system from the supply network.
nsure that cannot be re-connected inadvertently!
Before start of operation ensure appropriate
installation
Warning! Improper installation / operation impair
safety and result in operational difficulties or complete
failure of the unit.
The unit must be installed and put into service
appropriately by qualified personnel. Compliance with
the relevant regulations must be ensured.
With stranded wires: all strands must be secured in
the terminal blocks (potential danger of short circuit).
In operation: No modifications!
As long as the unit is in operation: do not modify the
installation! The same applies also to the secondary
side.
• The unit must not be opened except appropriately
trained personnel!
• Do not introduce any object into the unit!
• Keep away from fire and water!
FCC warnings
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1) this device may not cause harmful interference, and
2) this device must accept any interference received,
including interference that may cause undesired
operation.
© Copyright – Carlo Gavazzi - All rights reserved
This manual accompanies our equipment for use by the end users.
The technical instructions and illustrations contained in this manual are to be treated as confidential and no part
may be reproduced without the prior written permission of Carlo Gavazzi
Service engineers and end users may not divulge the information contained herein or use this manual for
purposes other than those strictly connected with correct use of the equipment.
Specifications are subject to change without notice. Pictures are just an example.
L1 L2 L3 L4 L5 L6
EXIT
EXIT
EXIT
EXIT
EXIT
12
3
45
45° 15°
1.5
2.5
0.5
4.5
m
4.5
m
3.5
0.5
1.5
2.5
3.5
0.5
1.0
1.5
2.0
2.5
3.0
m
0.5
1.5
2.5
3.5
4.5
m
0.5
1.0
1.5
2.0
m
0.5
1.0
1.5
2.0
m
00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.03.0 00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.03.0
00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.03.0 00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.03.0
00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.0
m
m
m3.0 00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.0
m
m
m3.0
S1
S5
S8
S10
S2
S4
S6
S10
S8
S1
S5
S8
S10
S4
S6
S8
S1
S5
S10
S1
S8
S10
S9
S10
4.92
8.20
1.64
14.76
ft
11.48
4.92
8.20
1.64
14.76
ft
11.48
1.64
3.28
4.92
6.56
8.20
9.84
ft
1.64
4.92
8.20
11.48
14.76
ft
1.64
3.28
4.92
6.56
ft
1.64
3.28
4.92
6.56
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
9.84
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
9.84
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
9.84
9.84
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
ft
9.84
9.84
1.5
2.5
0.5
4.5
m
4.5
m
3.5
0.5
1.5
2.5
3.5
0.5
1.0
1.5
2.0
2.5
3.0
m
0.5
1.5
2.5
3.5
4.5
m
0.5
1.0
1.5
2.0
m
0.5
1.0
1.5
2.0
m
00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.03.0 00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.03.0
00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.03.0 00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.03.0
00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.0
m
m
m3.0 00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.0
m
m
m3.0
S1
S5
S8
S10
S2
S4
S6
S10
S8
S1
S5
S8
S10
S4
S6
S8
S1
S5
S10
S1
S8
S10
S9
S10
4.92
8.20
1.64
14.76
ft
11.48
4.92
8.20
1.64
14.76
ft
11.48
1.64
3.28
4.92
6.56
8.20
9.84
ft
1.64
4.92
8.20
11.48
14.76
ft
1.64
3.28
4.92
6.56
ft
1.64
3.28
4.92
6.56
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
9.84
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
9.84
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
9.84
9.84
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
ft
9.84
9.84
h = 2.2m
h = 7.22ft
h = 2.2m
h = 7.22ft
1.5
2.5
0.5
4.5
m
4.5
m
3.5
0.5
1.5
2.5
3.5
0.5
1.0
1.5
2.0
2.5
3.0
m
0.5
1.5
2.5
3.5
4.5
m
0.5
1.0
1.5
2.0
m
0.5
1.0
1.5
2.0
m
00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.03.0 00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.03.0
00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.03.0 00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.03.0
00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.0
m
m
m3.0 00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.0
m
m
m3.0
S1
S5
S8
S10
S2
S4
S6
S10
S8
S1
S5
S8
S10
S4
S6
S8
S1
S5
S10
S1
S8
S10
S9
S10
4.92
8.20
1.64
14.76
ft
11.48
4.92
8.20
1.64
14.76
ft
11.48
1.64
3.28
4.92
6.56
8.20
9.84
ft
1.64
4.92
8.20
11.48
14.76
ft
1.64
3.28
4.92
6.56
ft
1.64
3.28
4.92
6.56
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
9.84
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
9.84
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
9.84
9.84
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
ft
9.84
9.84
1.5
2.5
0.5
4.5
m
4.5
m
3.5
0.5
1.5
2.5
3.5
0.5
1.0
1.5
2.0
2.5
3.0
m
0.5
1.5
2.5
3.5
4.5
m
0.5
1.0
1.5
2.0
m
0.5
1.0
1.5
2.0
m
00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.03.0 00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.03.0
00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.03.0 00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.03.0
00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.0
m
m
m3.0 00.50.5 1.01.0 1.51.5 2.02.0 2.52.5 3.0
m
m
m3.0
S1
S5
S8
S10
S2
S4
S6
S10
S8
S1
S5
S8
S10
S4
S6
S8
S1
S5
S10
S1
S8
S10
S9
S10
4.92
8.20
1.64
14.76
ft
11.48
4.92
8.20
1.64
14.76
ft
11.48
1.64
3.28
4.92
6.56
8.20
9.84
ft
1.64
4.92
8.20
11.48
14.76
ft
1.64
3.28
4.92
6.56
ft
1.64
3.28
4.92
6.56
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
9.84
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
9.84
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
9.84
9.84
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
ft
0
1.64
1.64
3.28
3.28
4.92
4.92
6.56
6.56
8.20
8.20
9.84
ft
9.84
9.84
h = 2.2m
h = 7.22ft
h = 2.2m
h = 7.22ft
L1 L2 L3 L4 L5 L6
L1 L2 L3 L4 L5 L6
L1 L2 L3 L4 L5 L6
L1 L2 L3 L4 L5 L6
Note: S1...S10 sensitivity levels setting.
Lateral angle rotation -15°
Main Connector
Relay NO contact
Relay NC contact
Relay Common
Supply Voltage
12 to 24 VAC/DC
12 to 24 VAC/DC
• Refer to the following table to change radar Set Values:
Factory Default Value
The device is set up in factory at the following default values:
1. Sensitivity: 10 (max level)
2. Relay hold time: 1 (min: 0.5 sec)
3. Uni-Bidirectional Detection Mode Bi-directional (Uni-directional mode is
available only for RAD 02)
4. Immunity detection: Immunity: OFF ; Quasi-Presence: OFF
5. Relay Status: Passive
6. PIN security: 0000 - block disabled
(only for remote controller)
At the first start up, the device loads the default values.
Radar set value can be modified through the two buttons on the main PC board (On Board setting
procedure) or with the IR remote controller [optional] (IR remote controller setting).
The differences between on board settings procedure and IR controller settings procedure are only in
“Relay status”, “Restore” and the “PIN security code” features. “Restore” feature is only available by on
board push buttons while PIN security code function is available only by remote controller. “Relay status
feature” is partly available by on board push buttons and partly by remote controller.
Programming procedure
Warranty
Carlo Gavazzi guarantees radar device to be free of manufacturing defects for 2 Years from purchasing
date. The guarantee intervenes when the device presents a material defect. The faulty device can be
returned back to our factory and will be repaired free of charge. If the defect is due to an exceeding of
the permissible technical data, wrong wiring, not permissible changes in equipment by the user or a
faulty operation no guarantee is carried out.
DEFECT ROBABLE CAUSE RECOVERY ACTION
Door will not open or close when
radar sensor is activated.
The radar is not powered on
correctly.
The relay output wiring is not
correct.
Control electrical wiring diagram.
Door always remains open or
closed when radar sensor is
activated.
The radar always works with
OP N or CLOS features set on.
Set on AUTO feature by IR remote
controller.
Door is activated in reverse
mode.
Relay Status feature is set on
ACTIV (NC) or PASSIV (NO).
Set on AUTO feature by IR remote
controller.
Door constantly recycles (opens
and closes).
There is something moving in the
field detection area.
The radar sensor detects the door
motions.
Verify Immunity and Sensitivity set
values to increase radar motion
sensing feature.
Adjust vertical or lateral detection
angle and Sensing Field.
IR remote controller keyboard
does not work.
Remote control is lock.
The user PIN security code
entered with remote controller is
not correct.
Insert the correct user PIN
security code.
Refer to On Board Setting
Procedure and restore factory PIN
code.
Radar does not respond to the
Remote Controller Setting
Procedure.
Remote controller batteries are
run-down.
Remote Controller is not well
oriented toward radar sensor.
Check remote controller battery
insertion and voltage.
Orient the remote controller
correctly toward radar sensor.
Trou le Shooting
Please refer to the following tables in order to modify radar parameters setting with remote controller.
All changes made by remote controller, except (OP N, CLOS and AUTO), are stored into the radar memory
and reloaded during radar restart.
KEY FUNCTION
RED
LED
RES ONS
E
GREEN
LED
RES ONSE
1
0...9
Numerical keys NON NON
2
UNLOCK
If PIN is not equal to 0000
(factory default value),
press “UNLOCK” key
and insert the correct PIN
code to enable remote
controller setting.
See next
table NON
3
LOCK
If PIN is not equal to 0000
(factory default value),
press “LOCK” key to
disable remote controller
setting.
See next
table NON
4
TIM -
Press “TIM –” key to
decrease Hold Time set
value.
1…10
quick flash NON
5
TIM +
Press “TIM +” key to
increase Hold Time set
value.
1…10
quick flash NON
6
S NS -
Press “S NS -” key to
decrease Sensitivity set
value.
1…10
quick flash NON
7
S NS +
Press “S NS +” key to
increase Sensitivity
value.
1…10
quick flash NON
8
PIN
Press “PIN” key to
change 4-number PIN
(It’s necessary to insert
the user PIN code if it’s
different from Factory
Default Value).
See next
table NON
The remote controller device can be disabled inserting a four numbers PIN code therefore. All IR-remote
setting functions are available only if the correct PIN is inserted. The Security feature is activated only if
the PIN is different from 0000 (factory set value).
The next table shows the procedure to modify and set PIN Security code:
PIN Security code
FOUR IN CODE SETTING
ACTUAL
IN VALUE
STE
1
STE
2
STE
3
US R’S
ACTION
RD L D
ANSW R
US R’S
ACTION
RD L D
ANSW R
US R’S
ACTION
RD L D
ANSW R
Actual PIN
code = 0000
(Factory set
value)
Press once
“PIN” key.
Red L D will
flash once.
Compose
sequentially 0000
code with remote
controller
keyboard
.
Red L D will
flash twice.
Compose
sequentially the
new XXXX PIN
value with
remote controller
keyboard.
The red L D
will flash three
times (The
new XXXX PIN
code now is
set).
Actual PIN
code = xxxx
(User set
value)
Press once
“PIN” key.
Red L D will
flash once.
Compose
sequentially the
actual XXXX
code value with
r e m o t e
c o n t r o l l e r
keyboard.
Red L D will
flash twice if
PIN code is
OK: get to
Step 3.
No flash will
happen if PIN
code is not
correct: restart
from Step 1.
C o m p o s e
sequentially
the new YYYY
PIN value with
r e m o t e
c o n t r o l l e r
keyboard.
The red L D
will flash three
times (The
new YYYY
PIN code now
is set).
IR REMOTE CONTROLLER UNLOCK
ACTUAL
IN VALUE
STE
1
STE
2
STE
3
US R’S
ACTION
R D L D
ANSW R
US R’S
ACTION
R D L D
ANSW R
US R’S
ACTION
Actual PIN
code = 0000
(Factory set
value)
Not
available.
X
Not
available.
X
Not
available.
Actual PIN
code = xxxx
(User set
value)
Press once
“UNL O C K ”
key.
Red L D will
flash once.
Compose
sequentially the
actual XXXX
code value with
r e m o t e
controller
keyboard.
Red L D will
flash twice if PIN
code is OK: get
to Step 3.
No flash will
happen if PIN
code is not
correct: restart
from Step 1.
IR remote device keyboard is
activated and it’s possible to
use the device for setting
parameters.
IR REMOTE
CONTROLLER LOCK
ACTUAL
IN VALUE
STE 1 STE 2
US R’S
ACTION R D L D ANSW R US R’S
ACTION
Actual PIN
code = 0000
(Factory set
value)
Not
available. XNot
available.
Actual PIN
code = xxxx
(User set
value)
Press once “LOCK” key. Red L D will flash once.
IR remote device keyboard is
disconnected and it’s not
possible to use the device for
setting parameters.
Notes:
• If no events happened per one minute, radar will restart automatically and reload the previous current
set values; Red L D will flash quickly per 1 second.
• If you have forgotten PIN XXXX code, it’s possible to reset the PIN factory value through the two
buttons on the main PC board: please refer to “R STOR ” feature of On Board setting Procedure.
IR remote controller setting procedure
The next tables show the procedure to UNLOCK and LOCK the IR remote controller keyboard.
Type
Detection mode
Ordering Key
Type selection
RAD 01
Detection Mode
Bidirectional* 01
Uni&Bi-directional* 02
* Bidirectional: to detect motion towards and
away from the sensor
Uni & Bidirectional: to detect motion towards
and/or away from the sensor.
Type
IR remote controller
Accessory
RAD 00 RC
Electrical data
Frequency emitted (K-Band) 24.125GHz
Radiated power < 16dBm IRP
Rated supply voltage 12 – 24VAC ±10%
12 – 24VDC +30% / -
10%
Main frequency 50 to 60HZ
Power consumption < 1W (VA)
Output Relay SPDT
Rated Voltage 30VAC/DC
Max switching current 1A (resistive load)
Max switching power 30W
(resistive load)
Hold time 0.5 – 9s (adjustable)
Environmental data
Temperature range
-20°C to +70°C
(-4°F to +158°F
)
Humidity from 0% to 90%RH
Immunity R&TT 1999/5/ C
MC 2004/108/ C
Max. mounting height
4m
(13.12ft
)
Protection degree IP54
General data
Sensing field orientation double mechanical
adjustment,
lateral and vertical
Detection angle
Vertical
0° to 90° in 15° increments
Lateral +/- 30° in 7.5° increments
Sensing field shape
bidirectional model By Sensor module
orientation
Detecting area
(mounting height 2.2m (7.22ft))
Wide sensing field
4m (W) x 2m (D)
(13.12ft (W) x 6.56ft (D)
)
Narrow sensing field
2m (W) x 2.5m (D)
(6.56ft (W) x 8.20ft (D)
)
Detection mode
Only bidirectional
to detect motions towards
and away from sensor
Uni & bidirectional
to detect motions towards
or/and away from sensor
Motion detecting speed
0.05 - 1m/s (0.164 - 3.28fps)
(measured in the sensor axis)
Mechanical data
Housing Material Polycarbonate
Dimensions WxHxD
118 x 80 x 53mm
(4.645 x 3.149 x 2.086inch.)
Weight
150g
(5.29oz
)
Cable length 2.5m (8.20ft)
Colour Glossy/Translucid Black
Box Content
• Motion Radar Sensor
• Tie Clip for sensor fixing (RAD 01)
• Connecting cable
• Screws and anchor fixing set
• Instruction manual
Approvals
Manual Setting Device By two buttons on main
PCB board.
Remote Setting Device IR remote controller (optional)
Reset to factory set Value 1 - Restore PIN security code
(only by PCB buttons) 2 - Restore all factory values
Sensitivity 10 levels (1 to 10)
It allows increment or
decrement of detection
field.
Relay hold time 10 levels (0.5 to 9s)
It fixes the maintenance’s
time of the relay status.
Uni-bidirectional mode It sets direction mode
detection (only for uni-
bidirectional device).
Immunity detection “Quasi-presence”, Normal
mode, Increased Immunity
(Implemented by a digital filter)
Adjustment and Setting
It prevents some external
noise as objects carried
by wind, strong rain, etc.
Relay status
Active, Passive, (only by PCB buttons)
It permits to fix the relay
status: normally open or
close.
Automatic mode/ (only by IR remote controller)
Permanently Open/Close. It permits to enable or disable
normal sensor detection and
set ON or OFF permanently
relay output.
AUTO / OP N / CLOS
Security code 4-digit PIN access code
(only by IR remote controller) It permits to lock or unlock
optional remote controller
keyboard setting.
It is necessary to press simultaneously for 1
second the two PC-board buttons D C(-) and
INC(+) to enter in programming procedure.
When the two buttons are released the Green L D
states permanently active (ON) so the device is
ready to be set.
Next setting action must be done in 20 seconds,
otherwise the device return in normal operation
mode and it’s necessary to restart.
On oard setting procedure
KEY FUNCTION
RED
LED
RES ONSE
GREEN
LED
RES ONSE
9
OP N
Press “OP N” key to
disable normal radar
detection functionality
and to set Relay Status
output always ACTIV .
NON Always ON
10
CLOS
Press “CLOS ” key to
disable normal radar
detection functionality
and to set Relay Status
output always NOT
ACTIV .
NON A l w a y s
OFF
11
AUTO
Press “AUTO” key to
available normal radar
detection functionality.
NON NON
12
IMM
Press “IMM” key once
to activate or twice to
disable Immunity
feature.
1 quick
flash :ON
2 quick
flashes : OFF
NON
13
FORWARD
Press “FORWARD” key
to activate uni-
directional motion
detection towards the
sensor (available only
for RAD 02).
1 quick
flash NON
14
BACKWARD
Press “BACKWARD”
key to activate uni-
directional motion
detection away from the
sensor (available only
for RAD 02).
2 quick
flashes NON
15
BOTH
Press “BOTH” key to
activate bi-directional
motion detection
towards or away from
the sensor (available
only for RAD 02).
3 quick
flashes NON
16
QP
Press “QP” key once to
activate or twice to
disable Quasi-Presence
feature.
1 quick
flash :ON
2 quick
flashes : OFF
NON
STE S STE 0 STE 1 STE 2 STE 3
SETTING DESCRI TION US R’S
ACTION
GR N L D
STATUS
US R’S
ACTION
R D L D
STATUS
US R’S
ACTION R D L D STATUS US R’S
ACTION
ROGRAMMING
ROCEDURE START U
Press together
D C & INC per 1
sec.
Green L D
switch on
permanently.
XX X X
Press D C & INC per 1 sec. to go to
Sensitivity (see Sensitivity ST P 1) or
wait 20 sec. to end setting procedure.
SENSITIVITY X X
Press together
DC & INC per 1
sec.
Red L D will
flash once.
Press D C or INC per 1 sec. to increase
or decrease Sensitivity current value.
Red L D flashes the number of the new
set value (1…10 quick flashes).
Return to Step 2 or press D C & INC
per 1 sec. to go to Hold Time (see Hold
Time ST P 1) or wait 20 sec. to end
setting procedure.
HOLD TIME X X
Press together
DC & INC per 1
sec.
Red L D will
flash twice.
Press D C or INC per 1 sec. to increase
or decrease Hold Time current value
Red L D flashes the number of the new
set value (1…10 quick flashes).
Return to Step 2 or press D C & INC
per 1 sec. to go to Detection Mode
(see Detection Mode ST P 1) or wait
20 sec. to end setting procedure.
DETECTION MODE X X
Press together
D C & INC per 1
sec.
Red L D will
flash three
times.
Feature available only for RAD 02
model.
•RAD 01: press D C & INC per 1 sec.
to go to Immunity.
•RAD 02: press INC per 1 sec. to
change Detection Mode current
value.
Only for RAD 02 model:
1 quick Red L D flash: Toward;
2 quick Red L D flashes: Backward;
3 quick Red L D flashes: Toward and
Backward;
Return to Step 2 or press D C & INC
per 1 sec. to go to Immunity (see
Immunity ST P 1) or wait 20 sec. to
end setting procedure.
IMMUNITY X X
Press together
D C & INC per 1
sec.
Red L D will
flash four times.
Press INC per 1 sec. to change
Immunity current value.
1 quick flash: Immunity ON, QP OFF;
2 quick flashes: Immunity OFF, QP ON;
3 quick flashes: Immunity ON, QP ON;
4 quick flashes: Immunty OFF, QP OFF;
Return to Step 2 or press D C & INC
per 1 sec. to go to Relay Status (see
Relay Status ST P 1) or wait 20 sec. to
end setting procedure.
RELAY STATUS X X
Press together
D C & INC per 1
sec.
Red L D will
flash five times.
Press INC per 1 sec. to change Relays
Status current value
1 quick flash: Relay mode PASSIV
(NO);
2 quick flashes: Relay mode ACTIV
(NC);
Return to Step 2 or press D C & INC
per 1 sec. to go to Restore (see Restore
ST P 1) or wait 20 sec. to end setting
procedure.
RESTORE X X
Press together
DC & INC per 1
sec.
Red L D will
flash six times.
Press INC per 1 sec. to change Restore
current value.
1 quick flash: Restore PIN to 0000
2 quick flashes: Restore all to factory
default values.
Return to Step 2 or wait 20 sec. to end
setting procedure.
* Not available
RAD-M-ENG REV.00 02.06.08
1
F
23 4 5
6 7
SENS-
8
TIME+
TIME-
9
SENS+
0
OPEN CLOSE
DOOR
AUTO
IMM
PIN
QP
RAD-00-RC
1
11
10
7
2
16
12
15
9
0*
5
13
6
4
8
3
14
00668822
Warnings
Warning: Changes or modifications made to this equipment not expressly approved by CARLO
GAVAZZI LOGISTICS may void the FCC authorization to operate this equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Trade Name: Carlo Gavazzi Logistics S.p.A.
via Milano 13, I-20020 Lainate (MI)
Model No: RAD01 / RAD01N
FCC ID: U7PRAD01
IC: 7118A-RAD01
Model No: RAD02 / RAD02N
FCC ID: U7PRAD02
IC: 7118A-RAD02
This device com lies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. O eration is subject to the following two conditions. (1) this device may not cause
harmful interference, and (2) this device must acce t any interference received, including interference that may cause undesired o eration.
Specifications are subject to change without notice. Pictures are just an example.
RG
STEPS 1 2 3
ACTION LED ACTION LED ACTION
1
SENSITI ITY
SENSIBILIDAD
SENSIBILITÉ
SENSIBILITÁ
EMPFINDLICHKEIT
GE OELIGHEID
>1s
G
1
R
1…
R10
>20s
2
HOLD TIME
TIEMPO DE RETARDO
TEMPS DE MAINTIEN DU RELAIS
TEMPO DI MANTENIMENTO DEL RELÉ
HALTEZEIT DES RELAIS
ACTI ERINGSTIJD RELAIS
>1s
G
2
R
1…
R10
>20s
3
DETECTION MODE
MODO DE DETECCIÓN
DÉTECTION
MODALITÀ DI RILE AMENTO
BETRIEBSART
DETECTIE PRINCIPE
>1s
G
3
R
>1s
>
1
R
2
R
3
R
>20s
4
IMMUNITY
INMUNIDAD
IMMUNITÉ
IMMUNITÁ
IMMUNITÄT
IMMUNITEIT
>1s
G
4
R
>1s
>20s
5
RELAY STATUS
ESTADO DEL RELÉ
ÉTAT DU RELAIS
STATO DEL RELÉ
RELAISZUSTAND
RELAIS STATUS
>1s
G
5
R
>1s
1
R
2
R
>20s
6
RESTORE
RESTABLECIMIENTO
RàZ DES PARAMÉTRAGES D’USINE
RESET SETTAGGI DI FABBRICA
RÜCKSTELLUNG
RESET
>1s
G
6
R
>1s
1
R
2
R
>20s
>1s
>
2
R
2
R
IMMUNITY
IMMUNIDAD
IMMUNITÉ
IMMUNITÁ
IMMUNITÄT
IMMUNITEIT
QUASI
RESENCE
1
R
ON OFF
R2
OFF ON
3
R
ON ON
4
R
OFF OFF
RAD 01
RAD 02
Default = 10
Default = 1
ASSIVE (NO)
ACTIVE (NC)
IN = 0000
DEFAULT
ON BOARD QUICK SET-UP TABLE
R
R
R
R
R
R
0
START PROGRAMMING
INICIAR EL PROGRAMA
DEBUT DE PROGRAMMATION
INIZIO PROGRAMMAZIONE
PROGRAMMIERUNGSANFANG
START INSTELLINGEN
>1s
G
G
R
1 2 3 4 5 6 7 8 9 10
Value
1 MIN
2 3 4 5 6 7 8 9
10MAX
R
1 2 3 4 5 6 7 8 9 10
sec.
0.5
1 2 3 4 5 6 7 8
9
RED BLINKING LED
LED ROJO AR ADEANTE
LED ROUGE CLIGNOTANT
LED ROSSO LAM EGGIANTE
ROTE BLINKEN LED-ANZEIGE
RODE LED HET KNI EREN
GREEN LED
LED VERDE
LED VERTE
LED VERDE
GRÜNE LED-ANZEIGE
GROENE LED
DECREASE
DISMINUIR
DIMINUER
DIMINUIRE
KÜRZEN
VERMEERDEREN
INCREASE
AUMENTAR
AUGMENTER
AUMENTARE
ERHÖHEN
VERMINDEREN
Specifications are subject to change without notice. Pictures are just an example.
ACTION/LED DESCRIPTION
1
F
2345
67
SENS -
8
TIME +
TIME -
9
SENS +
S
0
OPEN CLOSE
DOOR
AUTO
IMM
PIN
QP
RAD-00-RC
DESCRIPTION ACTION/LED
O EN CLOSE
NUMMERICAL KEYS
TECLA NUMÉRICA
AVÉ NUMVRIQUE
TASTIERA NUMERICA
NNUMMERIEKE TOETSEN
AUTO
1…
R10
HOLD TIME
TIEM O DE RETARDO
TEM S DE MAINTIEN DU RELAIS
TEM O DI MANTENIMENTO DEL RELÉ
HALTEZEIT DES RELAIS
ACTIVERINGSTIJD RELAIS
SENSITIVITY
SENSIBILIDAD
SENSIBILITÉ
SENSIBILITÁ
EM FINDLICHKEIT
GEVOELIGHEID
1…
R10
1…
R10
SENSITIVITY
SENSIBILIDAD
SENSIBILITÉ
SENSIBILITÁ
EM FINDLICHKEIT
GEVOELIGHEID
HOLD TIME
TIEM O DE RETARDO
TEM S DE MAINTIEN DU RELAIS
TEM O DI MANTENIMENTO DEL RELÉ
HALTEZEIT DES RELAIS
ACTIVERINGSTIJD RELAIS
1…
R10
Refer to the manual
Referirse al manual
Consulter la notice
Riferirsi al manuale
Siehe Manual
Raadpleed de handleiding
LOCK
IN Key
Código IN
Code IN
Codice IN
IN Code
IN Code
Refer to the manual
Referirse al manual
Consulter la notice
Riferirsi al manuale
Siehe Manual
Raadpleed de handleiding
1
R
DETECTION MODE
MODO DE DETECCIÓN
DÉTECTION
MODALITÀ DI RILEVAMENTO
BETRIEBSART
DETECTIE RINCI E
UNLOCK
Refer to the manual
Código IN
Consulter la notice
Riferirsi al manuale
Siehe Manual
Raadpleed de handleiding
R2
DETECTION MODE
MODO DE DETECCIÓN
DÉTECTION
MODALITÀ DI RILEVAMENTO
BETRIEBSART
DETECTIE RINCI E
QUASI RESENCE
1
R
R2
ON
OFF
3
R
DETECTION MODE
MODO DE DETECCIÓN
DÉTECTION
MODALITÀ DI RILEVAMENTO
BETRIEBSART
DETECTIE RINCI E
IMMUNITY
INMUNIDAD
IMMUNITÉ
IMMUNITÁ
IMMUNITÄT
IMMUNITEIT
1
R
R2
ON
OFF
QUICK SET-UP TABLE BY REMOTE CONTROL

This manual suits for next models

2

Other CARLO GAVAZZI Security Sensor manuals

CARLO GAVAZZI Guardian 2 Product information sheet

CARLO GAVAZZI

CARLO GAVAZZI Guardian 2 Product information sheet

CARLO GAVAZZI Guardian 2 Product information sheet

CARLO GAVAZZI

CARLO GAVAZZI Guardian 2 Product information sheet

CARLO GAVAZZI LDP1 User manual

CARLO GAVAZZI

CARLO GAVAZZI LDP1 User manual

CARLO GAVAZZI Guardian 1 Product information sheet

CARLO GAVAZZI

CARLO GAVAZZI Guardian 1 Product information sheet

CARLO GAVAZZI LDP1 User manual

CARLO GAVAZZI

CARLO GAVAZZI LDP1 User manual

CARLO GAVAZZI CAR PARK 3 OUTDOOR Owner's manual

CARLO GAVAZZI

CARLO GAVAZZI CAR PARK 3 OUTDOOR Owner's manual

CARLO GAVAZZI SMS User manual

CARLO GAVAZZI

CARLO GAVAZZI SMS User manual

CARLO GAVAZZI DLI-P360L24MF User manual

CARLO GAVAZZI

CARLO GAVAZZI DLI-P360L24MF User manual

CARLO GAVAZZI LDD1 User manual

CARLO GAVAZZI

CARLO GAVAZZI LDD1 User manual

CARLO GAVAZZI TRIPLESHIELD CA User manual

CARLO GAVAZZI

CARLO GAVAZZI TRIPLESHIELD CA User manual

Popular Security Sensor manuals by other brands

STEINEL IR Quattro SLIM Series manual

STEINEL

STEINEL IR Quattro SLIM Series manual

SkyLink HA-434 quick start guide

SkyLink

SkyLink HA-434 quick start guide

Visonic Vi-motion installation instructions

Visonic

Visonic Vi-motion installation instructions

P&E PE-7208P User manual & installation guide

P&E

P&E PE-7208P User manual & installation guide

Otto Bock 8S5 Series Instructions for use

Otto Bock

Otto Bock 8S5 Series Instructions for use

DBI SALA LAD-SAF 5000338 instruction manual

DBI SALA

DBI SALA LAD-SAF 5000338 instruction manual

GasTech F-GUARD IR3-HD user manual

GasTech

GasTech F-GUARD IR3-HD user manual

Zircon Leak Alert WiFi manual

Zircon

Zircon Leak Alert WiFi manual

König SAS-ASNS4xx-QIG Series user manual

König

König SAS-ASNS4xx-QIG Series user manual

Kompernass BA 105 A1 operating instructions

Kompernass

Kompernass BA 105 A1 operating instructions

TKF ACE Guideline

TKF

TKF ACE Guideline

System Sensor WFD20 Installation and maintenance instructions

System Sensor

System Sensor WFD20 Installation and maintenance instructions

WT sensor PC12K quick start guide

WT sensor

WT sensor PC12K quick start guide

PCB Piezotronics W109C12/038CY010AC Installation and operating manual

PCB Piezotronics

PCB Piezotronics W109C12/038CY010AC Installation and operating manual

Zumtobel ONLITE manual

Zumtobel

Zumtobel ONLITE manual

PCB 4115K-08A Installation and operating manual

PCB

PCB 4115K-08A Installation and operating manual

Baumer UNAM 30U6103/S14 quick start guide

Baumer

Baumer UNAM 30U6103/S14 quick start guide

schmersal AZM 200 operating instructions

schmersal

schmersal AZM 200 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.