• Refer to the following table to change radar Set Values:
Factory Default Value
The device is set up in factory at the following default values:
1. Sensitivity: 10 (max level)
2. Relay hold time: 1 (min: 0.5 sec)
3. Uni-Bidirectional Detection Mode Bi-directional (Uni-directional mode is
available only for RAD 02)
4. Immunity detection: Immunity: OFF ; Quasi-Presence: OFF
5. Relay Status: Passive
6. PIN security: 0000 - block disabled
(only for remote controller)
At the first start up, the device loads the default values.
Radar set value can be modified through the two buttons on the main PC board (On Board setting
procedure) or with the IR remote controller [optional] (IR remote controller setting).
The differences between on board settings procedure and IR controller settings procedure are only in
“Relay status”, “Restore” and the “PIN security code” features. “Restore” feature is only available by on
board push buttons while PIN security code function is available only by remote controller. “Relay status
feature” is partly available by on board push buttons and partly by remote controller.
Programming procedure
Warranty
Carlo Gavazzi guarantees radar device to be free of manufacturing defects for 2 Years from purchasing
date. The guarantee intervenes when the device presents a material defect. The faulty device can be
returned back to our factory and will be repaired free of charge. If the defect is due to an exceeding of
the permissible technical data, wrong wiring, not permissible changes in equipment by the user or a
faulty operation no guarantee is carried out.
DEFECT ROBABLE CAUSE RECOVERY ACTION
Door will not open or close when
radar sensor is activated.
The radar is not powered on
correctly.
The relay output wiring is not
correct.
Control electrical wiring diagram.
Door always remains open or
closed when radar sensor is
activated.
The radar always works with
OP N or CLOS features set on.
Set on AUTO feature by IR remote
controller.
Door is activated in reverse
mode.
Relay Status feature is set on
ACTIV (NC) or PASSIV (NO).
Set on AUTO feature by IR remote
controller.
Door constantly recycles (opens
and closes).
There is something moving in the
field detection area.
The radar sensor detects the door
motions.
Verify Immunity and Sensitivity set
values to increase radar motion
sensing feature.
Adjust vertical or lateral detection
angle and Sensing Field.
IR remote controller keyboard
does not work.
Remote control is lock.
The user PIN security code
entered with remote controller is
not correct.
Insert the correct user PIN
security code.
Refer to On Board Setting
Procedure and restore factory PIN
code.
Radar does not respond to the
Remote Controller Setting
Procedure.
Remote controller batteries are
run-down.
Remote Controller is not well
oriented toward radar sensor.
Check remote controller battery
insertion and voltage.
Orient the remote controller
correctly toward radar sensor.
Trou le Shooting
Please refer to the following tables in order to modify radar parameters setting with remote controller.
All changes made by remote controller, except (OP N, CLOS and AUTO), are stored into the radar memory
and reloaded during radar restart.
KEY FUNCTION
RED
LED
RES ONS
E
GREEN
LED
RES ONSE
1
0...9
Numerical keys NON NON
2
UNLOCK
If PIN is not equal to 0000
(factory default value),
press “UNLOCK” key
and insert the correct PIN
code to enable remote
controller setting.
See next
table NON
3
LOCK
If PIN is not equal to 0000
(factory default value),
press “LOCK” key to
disable remote controller
setting.
See next
table NON
4
TIM -
Press “TIM –” key to
decrease Hold Time set
value.
1…10
quick flash NON
5
TIM +
Press “TIM +” key to
increase Hold Time set
value.
1…10
quick flash NON
6
S NS -
Press “S NS -” key to
decrease Sensitivity set
value.
1…10
quick flash NON
7
S NS +
Press “S NS +” key to
increase Sensitivity
value.
1…10
quick flash NON
8
PIN
Press “PIN” key to
change 4-number PIN
(It’s necessary to insert
the user PIN code if it’s
different from Factory
Default Value).
See next
table NON
The remote controller device can be disabled inserting a four numbers PIN code therefore. All IR-remote
setting functions are available only if the correct PIN is inserted. The Security feature is activated only if
the PIN is different from 0000 (factory set value).
The next table shows the procedure to modify and set PIN Security code:
PIN Security code
FOUR IN CODE SETTING
ACTUAL
IN VALUE
STE
1
STE
2
STE
3
US R’S
ACTION
RD L D
ANSW R
US R’S
ACTION
RD L D
ANSW R
US R’S
ACTION
RD L D
ANSW R
Actual PIN
code = 0000
(Factory set
value)
Press once
“PIN” key.
Red L D will
flash once.
Compose
sequentially 0000
code with remote
controller
keyboard
.
Red L D will
flash twice.
Compose
sequentially the
new XXXX PIN
value with
remote controller
keyboard.
The red L D
will flash three
times (The
new XXXX PIN
code now is
set).
Actual PIN
code = xxxx
(User set
value)
Press once
“PIN” key.
Red L D will
flash once.
Compose
sequentially the
actual XXXX
code value with
r e m o t e
c o n t r o l l e r
keyboard.
Red L D will
flash twice if
PIN code is
OK: get to
Step 3.
No flash will
happen if PIN
code is not
correct: restart
from Step 1.
C o m p o s e
sequentially
the new YYYY
PIN value with
r e m o t e
c o n t r o l l e r
keyboard.
The red L D
will flash three
times (The
new YYYY
PIN code now
is set).
IR REMOTE CONTROLLER UNLOCK
ACTUAL
IN VALUE
STE
1
STE
2
STE
3
US R’S
ACTION
R D L D
ANSW R
US R’S
ACTION
R D L D
ANSW R
US R’S
ACTION
Actual PIN
code = 0000
(Factory set
value)
Not
available.
X
Not
available.
X
Not
available.
Actual PIN
code = xxxx
(User set
value)
Press once
“UNL O C K ”
key.
Red L D will
flash once.
Compose
sequentially the
actual XXXX
code value with
r e m o t e
controller
keyboard.
Red L D will
flash twice if PIN
code is OK: get
to Step 3.
No flash will
happen if PIN
code is not
correct: restart
from Step 1.
IR remote device keyboard is
activated and it’s possible to
use the device for setting
parameters.
IR REMOTE
CONTROLLER LOCK
ACTUAL
IN VALUE
STE 1 STE 2
US R’S
ACTION R D L D ANSW R US R’S
ACTION
Actual PIN
code = 0000
(Factory set
value)
Not
available. XNot
available.
Actual PIN
code = xxxx
(User set
value)
Press once “LOCK” key. Red L D will flash once.
IR remote device keyboard is
disconnected and it’s not
possible to use the device for
setting parameters.
Notes:
• If no events happened per one minute, radar will restart automatically and reload the previous current
set values; Red L D will flash quickly per 1 second.
• If you have forgotten PIN XXXX code, it’s possible to reset the PIN factory value through the two
buttons on the main PC board: please refer to “R STOR ” feature of On Board setting Procedure.
IR remote controller setting procedure
The next tables show the procedure to UNLOCK and LOCK the IR remote controller keyboard.
Type
Detection mode
Ordering Key
Type selection
RAD 01
Detection Mode
Bidirectional* 01
Uni&Bi-directional* 02
* Bidirectional: to detect motion towards and
away from the sensor
Uni & Bidirectional: to detect motion towards
and/or away from the sensor.
Type
IR remote controller
Accessory
RAD 00 RC
Electrical data
Frequency emitted (K-Band) 24.125GHz
Radiated power < 16dBm IRP
Rated supply voltage 12 – 24VAC ±10%
12 – 24VDC +30% / -
10%
Main frequency 50 to 60HZ
Power consumption < 1W (VA)
Output Relay SPDT
Rated Voltage 30VAC/DC
Max switching current 1A (resistive load)
Max switching power 30W
(resistive load)
Hold time 0.5 – 9s (adjustable)
Environmental data
Temperature range
-20°C to +70°C
(-4°F to +158°F
)
Humidity from 0% to 90%RH
Immunity R&TT 1999/5/ C
MC 2004/108/ C
Max. mounting height
4m
(13.12ft
)
Protection degree IP54
General data
Sensing field orientation double mechanical
adjustment,
lateral and vertical
Detection angle
Vertical
0° to 90° in 15° increments
Lateral +/- 30° in 7.5° increments
Sensing field shape
bidirectional model By Sensor module
orientation
Detecting area
(mounting height 2.2m (7.22ft))
Wide sensing field
4m (W) x 2m (D)
(13.12ft (W) x 6.56ft (D)
)
Narrow sensing field
2m (W) x 2.5m (D)
(6.56ft (W) x 8.20ft (D)
)
Detection mode
Only bidirectional
to detect motions towards
and away from sensor
Uni & bidirectional
to detect motions towards
or/and away from sensor
Motion detecting speed
0.05 - 1m/s (0.164 - 3.28fps)
(measured in the sensor axis)
Mechanical data
Housing Material Polycarbonate
Dimensions WxHxD
118 x 80 x 53mm
(4.645 x 3.149 x 2.086inch.)
Weight
150g
(5.29oz
)
Cable length 2.5m (8.20ft)
Colour Glossy/Translucid Black
Box Content
• Motion Radar Sensor
• Tie Clip for sensor fixing (RAD 01)
• Connecting cable
• Screws and anchor fixing set
• Instruction manual
Approvals
Manual Setting Device By two buttons on main
PCB board.
Remote Setting Device IR remote controller (optional)
Reset to factory set Value 1 - Restore PIN security code
(only by PCB buttons) 2 - Restore all factory values
Sensitivity 10 levels (1 to 10)
It allows increment or
decrement of detection
field.
Relay hold time 10 levels (0.5 to 9s)
It fixes the maintenance’s
time of the relay status.
Uni-bidirectional mode It sets direction mode
detection (only for uni-
bidirectional device).
Immunity detection “Quasi-presence”, Normal
mode, Increased Immunity
(Implemented by a digital filter)
Adjustment and Setting
It prevents some external
noise as objects carried
by wind, strong rain, etc.
Relay status
Active, Passive, (only by PCB buttons)
It permits to fix the relay
status: normally open or
close.
Automatic mode/ (only by IR remote controller)
Permanently Open/Close. It permits to enable or disable
normal sensor detection and
set ON or OFF permanently
relay output.
AUTO / OP N / CLOS
Security code 4-digit PIN access code
(only by IR remote controller) It permits to lock or unlock
optional remote controller
keyboard setting.
It is necessary to press simultaneously for 1
second the two PC-board buttons D C(-) and
INC(+) to enter in programming procedure.
When the two buttons are released the Green L D
states permanently active (ON) so the device is
ready to be set.
Next setting action must be done in 20 seconds,
otherwise the device return in normal operation
mode and it’s necessary to restart.
On oard setting procedure
KEY FUNCTION
RED
LED
RES ONSE
GREEN
LED
RES ONSE
9
OP N
Press “OP N” key to
disable normal radar
detection functionality
and to set Relay Status
output always ACTIV .
NON Always ON
10
CLOS
Press “CLOS ” key to
disable normal radar
detection functionality
and to set Relay Status
output always NOT
ACTIV .
NON A l w a y s
OFF
11
AUTO
Press “AUTO” key to
available normal radar
detection functionality.
NON NON
12
IMM
Press “IMM” key once
to activate or twice to
disable Immunity
feature.
1 quick
flash :ON
2 quick
flashes : OFF
NON
13
FORWARD
Press “FORWARD” key
to activate uni-
directional motion
detection towards the
sensor (available only
for RAD 02).
1 quick
flash NON
14
BACKWARD
Press “BACKWARD”
key to activate uni-
directional motion
detection away from the
sensor (available only
for RAD 02).
2 quick
flashes NON
15
BOTH
Press “BOTH” key to
activate bi-directional
motion detection
towards or away from
the sensor (available
only for RAD 02).
3 quick
flashes NON
16
QP
Press “QP” key once to
activate or twice to
disable Quasi-Presence
feature.
1 quick
flash :ON
2 quick
flashes : OFF
NON
STE S STE 0 STE 1 STE 2 STE 3
SETTING DESCRI TION US R’S
ACTION
GR N L D
STATUS
US R’S
ACTION
R D L D
STATUS
US R’S
ACTION R D L D STATUS US R’S
ACTION
ROGRAMMING
ROCEDURE START U
Press together
D C & INC per 1
sec.
Green L D
switch on
permanently.
XX X X
Press D C & INC per 1 sec. to go to
Sensitivity (see Sensitivity ST P 1) or
wait 20 sec. to end setting procedure.
SENSITIVITY X X
Press together
DC & INC per 1
sec.
Red L D will
flash once.
Press D C or INC per 1 sec. to increase
or decrease Sensitivity current value.
Red L D flashes the number of the new
set value (1…10 quick flashes).
Return to Step 2 or press D C & INC
per 1 sec. to go to Hold Time (see Hold
Time ST P 1) or wait 20 sec. to end
setting procedure.
HOLD TIME X X
Press together
DC & INC per 1
sec.
Red L D will
flash twice.
Press D C or INC per 1 sec. to increase
or decrease Hold Time current value
Red L D flashes the number of the new
set value (1…10 quick flashes).
Return to Step 2 or press D C & INC
per 1 sec. to go to Detection Mode
(see Detection Mode ST P 1) or wait
20 sec. to end setting procedure.
DETECTION MODE X X
Press together
D C & INC per 1
sec.
Red L D will
flash three
times.
Feature available only for RAD 02
model.
•RAD 01: press D C & INC per 1 sec.
to go to Immunity.
•RAD 02: press INC per 1 sec. to
change Detection Mode current
value.
Only for RAD 02 model:
1 quick Red L D flash: Toward;
2 quick Red L D flashes: Backward;
3 quick Red L D flashes: Toward and
Backward;
Return to Step 2 or press D C & INC
per 1 sec. to go to Immunity (see
Immunity ST P 1) or wait 20 sec. to
end setting procedure.
IMMUNITY X X
Press together
D C & INC per 1
sec.
Red L D will
flash four times.
Press INC per 1 sec. to change
Immunity current value.
1 quick flash: Immunity ON, QP OFF;
2 quick flashes: Immunity OFF, QP ON;
3 quick flashes: Immunity ON, QP ON;
4 quick flashes: Immunty OFF, QP OFF;
Return to Step 2 or press D C & INC
per 1 sec. to go to Relay Status (see
Relay Status ST P 1) or wait 20 sec. to
end setting procedure.
RELAY STATUS X X
Press together
D C & INC per 1
sec.
Red L D will
flash five times.
Press INC per 1 sec. to change Relays
Status current value
1 quick flash: Relay mode PASSIV
(NO);
2 quick flashes: Relay mode ACTIV
(NC);
Return to Step 2 or press D C & INC
per 1 sec. to go to Restore (see Restore
ST P 1) or wait 20 sec. to end setting
procedure.
RESTORE X X
Press together
DC & INC per 1
sec.
Red L D will
flash six times.
Press INC per 1 sec. to change Restore
current value.
1 quick flash: Restore PIN to 0000
2 quick flashes: Restore all to factory
default values.
Return to Step 2 or wait 20 sec. to end
setting procedure.
* Not available
RAD-M-ENG REV.00 02.06.08