SAFETYCONSIDERATIONS
Readandfollowmanufacturerinstructionscarefully.Followall
localelectricalcodesduringinstallation.Allwiringmustconform
tolocalandnationalelectricalcodes.Improperwiringor
installationmaydamagetheInfinitySystem.Recognizesafety
information.Thisisthesafety-alertsymbol/_'. When you see
this symbol on the equipment and in the instruction manual, be
alert to the potential fnr personal injury. Understand the signal
words DANGER. WARNING, and CAUTION.
These words are used with the safety-alert symbol. DANGER
identifies the most serious hazards, which will result in severe
personal injury or death. WARNING signifies a hazard, which
could result in personal injury or death. CAUTION is used to
identify unsafe practices, which may result in minor personal
injury or product and property damage. NOTE is used to
highlight suggestions which will result in enhanced installation,
reliability, or operation.
INTRODUCTION
The Infinity System consists of several intelligent communicating
components which includes the Infinity Control (or User
Interface), variable speed furnace or FE fan coil, 2-stage AC or
HP and Infinity Packaged Products, which continually
communicate with each other via a four-wire connection called
the ABCD bus. Commands, operating conditions, and other data
are passed continually between components over the ABCD bus.
The result is a new level of comfort, versatility, and simplicity.
All Infinity furnaces or fan coils are variable-speed and nmlti
stage for maximum flexibility, efficiency, and comfort. They
support controlled ventilation, humidification, dehumidification,
and air quality control. Either an Infinity (communicating), or a
standard 24 vac controlled outdoor unit may be used.
When using conventional outdoor units, the Infinity furnace or
fan coil provides the 24 volt signals needed to control them. Also,
the Infinity Network Interface Module (P/N SYSTXCCNIM01)
allows connection of a Carrier HRV or ERV without the need for
a separate wall control.
All system components are controlled through the wall mounted
Infinity Control. which replaces the conventional thermostat and
provides the homeowner with a single wall control fnr all features
of the system.
INSTALLATION AND START-UP OVERVIEW
This instruction covers installation of the Infinity Control only.
Physical installation instructions for the indoor and outdoor
equipment, and accessories are provided with each unit.
Setup, commissioning, operation, and troubleshooting of the
Infinity System are covered only in this installation instruction. It
is the guide to connecting the system components and
commissioning the system once all physical components are
installed. Special screen prompts and start-up capabilities are
provided in the Infinity System to simplify and automate the
initial commissioning of the system.
• Install Infinity Control according to this instruction.
• Install indoor unit, outdoor unit, and accessories ac-
cording to their instructions.
• Wire complete system according to this instruction.
• Setup, commission, and operate system according to
this instruction to assure a smooth and trouble free
start-up.
INSTALLATION
SECTION 1.--CHECK EQUIPMENT AND JOB SITE
Inspect equipment. File claim with shipping company prior to
installation if shipment is damaged or incomplete.
SECTION 2.--INFINITY CONTROL LOCATION AND
WIRING CONSIDERATIONS
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury
or death.
Disconnect Power befnre routing control wiring.
All wiring must comply with national, local, and state codes.
INFINITY CONTROL LOCATION -- The Infinity Control
User Interface is the command center fnr the Infinity System. It
should be located where it is easily accessible and visible to the
adult homeowner or end user.
For accurate temperature measurement, the following guidelines
should be followed:
The Infinity Control and Room Sensors should be
mounted:
•Approximately 5 feet (1.5 nmters) from the floor.
• Close to or in a frequently used room, preferably on an
inside partitioning wall.
• On a section of wall without pipes or ductwork.
The Infinity Control and Room Sensors should NOT be
mounted:
•Close to a window, on an outside wall, or next to a
door leading to the outside.
• Exposed to direct light or heat from a lamp, sun,
fireplace, or other temperature-radiating objects which
could cause a false reading.
• Close to or in direct airflow from supply registers.
• In areas with poor air circulation, such as behind a door
or in an alcove.
REMOTE ROOM SENSOR OPTION -- A Remote Room
Sensor can be used with the Infinity Control to take the place of
the User Interface internal temperature sensor. This allows the
Infinity Control to be mounted in areas with less than optimal
airflow (such as near an exterior door, window or in a closet). The
remote sensor can be wired to the terminal block connectors
labeled $1 and $2 at the User Interface backplate, or the OS1 and
OS1C connection at the Damper Control Module. In either case,
the Infinity Control will automatically detect the Remote Room
Sensor and ignore its internal temperature sensor. It is also
important to note the humidity sensor cannot be remotely located.
so do not locate the Infinity Control in an area where humidity
sensing may not be accurate.
NOTE:S1 & $2 connection on UI backplate is now used for
Remote Room Sensor. NOT for OAT Sensor hookup.