SHENZHEN GUIYUAN INDUSTRY DEVELOPMENT CO.,LTD
Http://www.carymart.com E-Mail: sale@carymart.com
1) Connect the live wire of the AC power supply to terminal “L / +”, and the neutral wire of the AC power supply to terminal “N / -“.
2) Connect terminal C to the live wire of the AC power supply, connect terminal B to one side of the AC lamp, and connect another side of the AC
lamp to the neutral wire of the AC power supply.
Setting different control modes (We have set the receiver as Toggle control mode before delivery. If you want to use other control modes,
do as following operation):
1) Setting control mode Toggle: Connect Jumper-2.
Control mode Toggle (with transmitter CV-6): Press -> On; Press again -> Off.
Press button 1: Turn on relay 1 of receiver 1 (connect B and C, disconnectA and B), the lamp1 is on.
Press button 1 again: Turn off relay 1 of receiver 1 (disconnect B and C, connect Aand B), the lamp1 is off.
Press button 2: Turn on relay 2 of receiver 1 (connect B and C, disconnect A and B), the lamp2 is on.
Press button 2 again: Turn off relay 2 of receiver 1 (disconnect B and C, connect Aand B), the lamp2 is off.
…
Press button 5: Turn on relay 1 of receiver 3 (connect B and C, disconnect A and B), the lamp 5 is on.
Press button 5 again: Turn off relay 1 of receiver 3(disconnect B and C, connect A and B), the lamp 5 is off.
Press button 6: Turn on relay 2 of receiver 3 (connect B and C, disconnect A and B), the lamp 6 is on.
Press button 6 again: Turn off relay 2 of receiver 3 (disconnect B and C, connect Aand B), the lamp 6 is off.
2) Setting control mode Momentary: Connect Jumper-1.
Control mode Momentary (with transmitter CV-6): Press and hold -> On; Release -> Off.
Press and hold button 1: Turn on relay 1 of receiver 1 (connect B and C, disconnect A and B), the lamp1 is on.
Release button 1: Turn off relay 1 of receiver 1 (disconnect B and C, connect A and B), the lamp1 is off.
Press and hold button 2: Turn on relay 2 of receiver 1 (connect B and C, disconnectA and B), the lamp2 is on.
Release button 2: Turn off relay 2 of receiver 1 (disconnect B and C, connect A and B), the lamp2 is off.
…
Press and hold button 5: Turn on relay 1 of receiver 3 (connect B and C, disconnectA and B), the lamp 5 is on.
Release button 5: Turn off relay 1 of receiver 3 (disconnect B and C, connect A and B), the lamp 5 is off.
Press and hold button 6: Turn on relay 2 of receiver 3 (connect B and C, disconnectA and B), the lamp 6 is on.
Release button 6: Turn off relay 2 of receiver 3 (disconnect B and C, connect A and B), the lamp 6 is off.
3) Setting control mode Latched: Disconnect Jumper-1 and Jumper-2.
Control mode Latched (with transmitter CV-6): Press -> On, another relay Off; Press another button -> Off.
Press button 1: Turn on relay 1 of receiver 1 (connect B and C, disconnect A and B), the lamp1 is on.
Turn off the other relays of receivers (disconnect B and C, connect Aand B), the other lamps are off.
Press button 2: Turn on relay 2 of receiver 1 (connect B and C, disconnect A and B), the lamp2 is on.
Turn off the other relays of receivers (disconnect B and C, connect Aand B), the other lamps are off.
…
Press button 6: Turn on relay 2 of receiver 3 (connect B and C, disconnect A and B), the lamp6 is on.
Turn off the other relays of receivers (disconnect B and C, connect Aand B), the other lamps are off.
4) Setting control mode Momentary + Toggle: Connect Jumper-1 and Jumper-2.
Control mode Momentary (Channel 1): Press and hold -> On; Release -> Off.
Press and hold button 1: Turn on relay 1 of receiver 1 (connect B and C, disconnectA and B), the lamp1 is on.
Release button 1: Turn off relay 1 of receiver 1 (disconnect B and C, connect A and B), the lamp1 is off.
Control mode Toggle (Channel 2): Press -> On; Press again -> Off.
Press button 2: Turn on relay 2 of receiver 1 (connect B and C, disconnectA and B), the lamp2 is on.
Press button 2 again: Turn off relay 2 of receiver 1 (disconnect B and C, connect Aand B), the lamp2 is off.
…
Press button 5: Turn on relay 2 of receiver 3 (connect B and C, disconnectA and B), the lamp 6 is on.
Press button 5 again: Turn off relay 2 of receiver 3 (disconnect B and C, connect Aand B), the lamp 6 is off.
Manual control terminals:
The receiver has manual control terminals, you can connect external devices, sensors, or manual switches to control the receiver.
1) Signal input:
You can connect external devices (with low level output signal) to terminals “1”, “3”, the external device’s output signal can control the receiver.
When the external device outputs low level signal to terminal “1”and “3“, turn on the relay1 (connect terminals B and C, disconnect terminals A and
B).
When the external device does not output signal to terminal “1”and “3“,turn off the relay1 (disconnect terminals B and C, connect terminalsA and B).
You can connect external devices (with low level output signal) to terminals “2”, “3”, the external device’s output signal can control the receiver.
When the external device outputs low level signal to terminal “2”and “3“, turn on the relay2 (connect terminals B and C, disconnect terminals A and
B).
When the external device does not output signal to terminal “2”and “3“,turn off the relay2 (disconnect terminals B and C, connect terminalsA and B).
2) The manual switches:
You can connect one manual switch to terminals “1”, “3”, and then you can use this manual switch to control the receiver.
When connect terminals “1”and “3”, turn on the relay1 (connect terminals B and C, disconnect terminals A and B).