CBA RA-4961Q User manual

RA-4961-K1Q
Wireless Alert System
Manual
Features:
•Up to 1,000ft (305m) transmission range*
•18 Programmable ringtones
•Conne t up to 4 wireless transmitter
a essories
•Audible and visual alert via built-in
speaker and flashing light
•Wall or desktop mountable
•Output terminals for optional auxiliary
devi e
•Ea h hannel independently
programmable
* Transmission range will vary depending on installation and operating environment.
®
Kit Includes:
•Wireless Re eiver (RA-4961Q) •Wireless Pushbutton (RA-4961-PBQ)

CBA Wireless Alert System
2SECO-LARM U.S.A., Inc.
Table of Contents
:
Di ensions:
Dimensions
................................
............
2
Parts List ................................................ 3
Spe ifi ations ........................................ 3
Overview ................................................ 4
Installing the Re eiver ........................... 5
Installing the Pushbutton ....................... 5
Repla ing the Pushbutton Battery ......... 6
Pairing
A essories
...............................
6
Deleting Paired A essories ................. 7
Changing the Ringtone and Volume ..... 7
Setting the Notifi ation Mode ................ 7
Wiring an Auxiliary Devi e ..................... 8
Optional A essories ............................. 8
Warranty ................................................ 8
Pushbutton
5
1
/
4
"
(133
mm)
6
5
/
8
"
(169mm)
1
9
/
16
"
(40mm)
Receiver
2
1
/
8
"
(54
mm)
3
7
/
16
"
(87mm)
11
/
16
"
(
18
mm)
1
5
/
16
"
(34mm)
11
/
16
"
(18mm)
RESET
3
1
/
16
"
(78mm)

CBA Wireless Alert System
SECO-LARM U.S.A., Inc. 3
Specifications:
Model n
u ber
RA
-
4961Q
Frequency
914.8MH
z
Channels
4
Accessories per channel
1
Relay o
utput
(Channel 4 only)
1
(Form C Relay), 1A@50VDC
Power supply
3
"
C
"
batteries or 6VDC power adapter
(Both not in luded)
Current
draw
Standby
0.3mA
Max
22
0
mA
Esti ated battery l
ife
27
0 days (3 triggers/day)
Receiver low battery indicator
Notifi ation LED flashes every 5 se onds
Accessory low battery indicator
Zone LED for a essory blinks
ontinuously
Sound level (dB)
Up to
96dB@
1ft(
30 m
)
Operating te perature
32º~140º F (0º~60º C)
Di ensions
5
1
/
4
"
x1
9
/
16
"
x6
5
/
8
"
(133x40x169
mm)
Model n
u ber
RA
-
4961
-
PBQ
Frequency
914.8MH
z
Trans ission r
ange*
Up to 1,000ft
(305m)
Channel
s
1
Power
s
upply
CR2032 Battery
(in luded)
Current
draw
Standby
0.2
µ
A
Active
16m
A
Esti ated battery l
ife
400 days (3 triggers/day)
Low battery
indicator
Zone LED on re eiver blinks ontinuously
IP rating
IP45
Operating te perature
-
4
º~140º F (
-
2
0º~
60º C)
Di ensions
1
5
/
16
"
x
11
/
16
"
x
3
7
/
16
"
(
34
x
18
x
87
mm)
Receiver
(RA
-
4961Q)
Pushbutton
(RA
-
4961
-
PBQ)
1x Wireless alert re eiver
(RA
-
4961Q)
1x Wireless pushbutton (RA-4961-PBQ)
1x Manual
1x CR2032 battery for wireless pushbutton (RA-4961Q batteries not in luded)
Parts List:
*Transmission range will vary depending on installation and operating environment.

CBA Wireless Alert System
4SECO-LARM U.S.A., Inc.
Overview:
Receiver
Pushbutton
Notifi ation
sele tion
swit h
Open the front over.
Rear Side
Speaker
Notifi ation light
Channel
notifi ation
Battery ompartment
Volume ontrol
Channel
sele t
button
Tone
sele t
button
Front (Cover off)
Mounting holes
6VDC Input
Relay
swit hes
Wi
ring
terminal
RESET
Reset button
Front (Cover on)
Battery
holder
Pushbutton
A tivation LED
Front (Cover off)

CBA Wireless Alert System
SECO-LARM U.S.A., Inc. 5
Installing the Receiver:
1.
Open the
front over of the re eiver unit.
2. Determine how the re eiver will be powered. Either insert three "C" batteries
(observing orre t
polarity, not in luded) or onne t to 6VDC power supply (not in luded).
Low battery is indi ated
when the notifi ation light flashes on e every 5 se onds.
3. Program pushbutton and any other a essories (see Pairing Accessories pg. 6).
4. Re eiver may either be pla ed on a table or other surfa e, or it may be mounted on a wall.
For Wall Mounting
1. Hold the re eiver unit against the wall to get an idea of where the re eiver should be installed.
2. Install 2 s rews (not in luded) on the wall 2
5
/
16
" (58mm) apart.
3. Hang the re eiver on the s rews.
Re eiver
Wall
Installing the
Pushbutton
:
Re eiver
Table
1.
Remove
the
front over of the pushbutton by inserting a paper lip in the not h at the top of the
unit. Push down on the paper lip with for e and pull the top of the front over from the
pushbutton.
2. Mount the pushbutton to a wall or other surfa e using s rews (not in luded) through the two
mounting holes.
3.
On e the pushbutton has been mounted, snap the front over onto the unit.
Insert paper lip
in not h Remove over
Mounting
holes

CBA Wireless Alert System
6SECO-LARM U.S.A., Inc.
Replacing the Pushbutton Battery:
1.
Remove the front over of the pushbutton by inserting a paper lip in the not h at the
top of the
unit. Push down on the paper lip with for e and pull the top of the front over from the
pushbutton.
2. If there is a previous battery installed, use a fingernail or small obje t to remove the battery
from the battery holder.
3. Slide a CR2032 batter
y into the battery holder, making sure to observe orre t polarity (positive
fa es out).
4. Snap the front over onto the pushbutton.
Insert paper
lip
in not h
Remove over
Battery
holder
P
airing
Accessories:
1.
Enter programming mode by holding down the
hannel
sele t button until
the C
hannel 1
LED
flashes on the hannel notifi ation panel.
2. Press the hannel sele t button to y le through hannels until the desired hannel is sele ted.
3. Press the tone sele t button to y le through ringtones until the desired ringtone is sele ted.
4. Trigger the pushbutton or other a essory. On e the a essory is triggered, the re eiver will
beep indi ating the units have been paired. If another hannel lights up, this a essory is
already programmed on the indi ated hannel.
Note: If pairing an a essory to a hannel that is already paired with another a essory, the
original paired a essory will be deleted.
5. Press the hannel sele t button to move to the next hannel or to exit paring mode.
Note: If no a tivity for 30 se onds the re eiver will automati ally exit pairing mode.
Note:
Low battery for this and other a essories is shown on the re eiver. When an a essory
battery is low, the zone LED for that a essory will blink ontinuously.
Channel
sele t
button
Tone
sele t
button

CBA Wireless Alert System
SECO-LARM U.S.A., Inc. 7
Deleting Paired Accessories
:
1.
Enter programming mode by holding
down the hannel sele t button until
the
Channel 1 LED flashes on the hannel
notifi ation panel.
2. Press the hannel
sele t button to y le
through hannels until the desired
hannel is sele ted.
3. Press and hold the hannel sele t and
tone sele t buttons simultaneously until
a beep is heard and the hannel LED
flashes. Press hannel sele t button to
exit pairing mode. If no a tions within
30 se onds, the re eiver will
automati ally exit the pairing mode.
Note:
The reset button is used to res
e
t a hannel after it has been triggered. It is
not used to
lear any programming.
Tone
sele t
button
Channel
sele t
button
Changing the Ringtone and Volu e
:
1.
Enter programming mode by holding
down the hannel sele t button until
the Channel 1 LED flashes on the
hannel notifi ation panel.
2. Press the hannel sele t button to y le
through hannels until the desired
hannel is sele ted.
3. Press the tone sele t button to y le
through ringtones until the desired
ringtone is sele ted.
4. Press the hannel sele t button to exit
programming mode.
5. To adjust volume, use a small
s rewdriver to adjust the volume knob.
Volume
Tone
sele t
button
Channel
sele t
button
Setting the Notification Mode:
1.
The wireless alert re
eiver has three modes
–
Audible
Alarm, Visual Alarm, and Audible and Visual Alarm.
2. When the Notifi ation sele tion swit h is flipped to
Audible Alarm the re eiver speaker will sound and the
zone LED will light up.
3. When the swit h is flipped to Audible and Visual Alarm
the re eiver's speaker will sound, the notifi ation LED
will light up, and the zone LED will light up.
4.
When the swit h is flipped to Visual Alarm the re eiver's
notifi ation LED will flash and the zone LED will light up.
Audible Alarm
Audi
ble &
Visual Alarm
(Default)
Visual Alarm

CBA Wireless Alert System
8SECO-LARM U.S.A., Inc.
FCC COMPLIANCE STATEMENT: RA-4961-PBQ FCC ID: YAHDCX-800
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT
ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Noti e:
The hanges or modifi ations not expressly approved by the party responsible for omplian e ould void the user’s authority
to operate the equipment. IMPORTANT NOTE: To omply with the FCC RF exposure omplian e requirements, no hange
to the antenna or the devi e is permitted. Any hange to the antenna or the devi e ould result in the devi e ex eeding the
RF exposure requirements and void user’s authority to operate the devi e.
Optional Accessories
:
Wireless
Indoor PIR
Sensor
RA-4961-PRQ
Wireless
Vibrating
Receiver
RA-4961-VPQ
Wireless
Outdoor PIR
Sensor
RA-4961-DSQ
Wireless
Mailbox/Tilt
Sensor
RA-4961-MBQ
Wireless
Magnetic
Contact
RA-4961-MCQ
Wireless
Pushbutton
RA-4961-PBQ
Wiring an Auxiliary Device:
1.
To onne t an auxiliary notifi ation devi e to hannel 4, flip the left
(
relay
)
swit h to
"
ON
"
.
2. Flip the right (time) swit h to 2 for a 2-se ond a tivation time or 5 for a 5-se ond a tivation time.
3. Wire the auxiliary devi e to the wiring terminal a ording to the diagram below.
4. When hannel 4 is a tivated, the auxiliary devi e will also be triggered.
Note:
Default positions are "OFF" (rel
ay) and "2" (time).
NOTICE
:
The information and spe ifi ations printed in this manual are urrent at the time of publi ation.
However, the
SECO-LARM poli y is one of ontinual development and improvement. For this reason, SECO-
LARM reserves the right to
hange spe ifi ations without noti e. SECO-LARM is also not responsible for misprints or typographi al errors.
Trademarks
are the property of SECO-LARM USA In . or their respe tive owners.
Copyright © 2015 SECO-LARM U.S.A., In . All rights reserved. This material may not be reprodu ed
or opied, in whole or
in part, without the written permission of SECO-LARM.
LIMITED
WARRANTY:
This SECO-
LARM produ t is warranted against defe ts in material and workmanship while
used in normal servi e for one (1) year from the date of sale to the original ustomer. SECO-
LARM’s obligation is limited to
the repair or repla ement of any defe tive part if the unit is returned, transportation prepaid, to SECO-LARM.
This Warranty
is void if damage is aused by or attributed to a ts of God, physi al or ele tri al misuse or abuse, negle t, repair or
alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-
LARM determines that su h
equipment is not operating properly as a result of auses other than defe ts in material and workmanship.
The sole
obligation of SECO
-
LARM and the
pur haser’s ex lusive remedy, shall be limited to the repla ement or repair only, at
SECO-LARM’s option. In no event shall SECO-
LARM be liable for any spe ial, ollateral, in idental, or onsequential
personal or property damage of any kind to the pur haser or anyone else.
SECO
-
LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Website: www.se o-larm. om
PIHVK1
Phone: (949) 261-2999 | (800) 662-0800 Email: sales@se o-larm. om
MiRA-4961-K1Q_151001.do
TERMINALS
COM
N.C.
COM
N.O.
1A@50VDC
This manual suits for next models
2
Table of contents