CCS LDLB Series Manual

- 1 -
LDLB/LDLB-IP Series
Bar Lights
Instruction Guide
Thank you for purchasing a CCS product. To ensure proper use of
the product, please read this instruction guide before use and keep
it for your future reference.
These LED Light Units feature integrated light control and ON/OFF control circuits.
The LEDs are driven with a constant-current system and the light is set to any of 100 levels with variable-current control.
You can change between Constant Lighting Mode and Overdrive Mode.
You can manually set the light intensity from the operating panel or set it with an analog input (0 to 10 V) from an external device.
You can daisy-chain up to three Light Units to provide power and externally control the light intensity of all of the Light Units together.
The LDLB-IP Series provides IP67 water resistance.
Features
The following symbols indicate and classify the precautions in the
Instruction Guide.
PROHIBITED
DISASSEMBLY
PROHIBITED
DO NOT TOUCH
WITH WET HA NDS
DO NOT SUBJE CT
TO MOISTURE
MANDATORY
ACTIONS
These symbols indicate
prohibited actions.
This symbol indicates
required actions.
This product has been designed with full consideration of safety. However, incorrect usage of the product may result in
re, electric shock, or other serious accidents. Observe the following precautions.
Warning
Indicates that incorrect
usage may result in
serious injury or death.
Caution
Indicates that incorrect
usage may result in injury
or property damage.
The following symbols are used in this Instruction Guide to indicate
and classify the relative importance of warnings and cautions. Caution
Do not drop the product
or subject it to impact.
Doing so may cause the
product to malfunction. PROHIBITED
Do not bundle product
cables with highvoltage
lines or power lines.
Doing so may cause the
product to malfunction.
Allow leeway between
the cables when
installing them.
MANDATORY
ACTIONS
Be careful of static
electricity. Damage
to the LED light may
occur, if a person
charged with static
electricity touches it.
Keep the product away
from all items charged
with static electricity.
PROHIBITED
Before moving the
product, disconnect
all connecting cables.
Damaging the cables
may result in fire or
electric shock.
MANDATORY
ACTIONS
Do not bend a cable
past its natural bending
radius or jam a cable
into a narrow space
when wiring the
product. Doing so may
cause product failure.
PROHIBITED
Always hold onto the
plug or connector when
disconnecting the
cables. Pulling on the
cable may damage the
cable and result in fire
or electric shock.
MANDATORY
ACTIONS
Do not intentionally
short-circuit the
positive and negative
output terminals. PROHIBITED
If there is dust or other
foreign matter on the
electrodes, turn OFF
the power supply and
then use a dry cloth
to remove the dust or
foreign matter. Failure to
do so may result in re.
MANDATORY
ACTIONS
Be sure to use the
product within the
range of input voltage.
Applying the voltage
beyond the range may
cause product failure.
PROHIBITED
Do not wipe the product
with organic solvent s,
such as paint thinner or
benzene. Discoloration
or deterioration of the
product surfaces may
oc c ur.
PROHIBITED
1
2
3
45
6
Important Information for Equipment Safety
Confirming Product Information
Names and Functions of Parts
Connections Setting the Light Intensity on the Operating Panel
External Control of the Light Intensity
- Read Before Use -
Warning
Do not disassemble
or modify the product.
Doing so may result in
re or electric shock.
DISASSEMBLY
PROHIBITED
LED light radiation may
cause corneal or retinal
abnormalities if you
look directly at the light.
To prevent harmful light
exposure, never look
directly at the LED light.
MANDATORY
ACTIONS
Do not connect or
disconnect the Light
Unit and cables with
wet hands. Doing so
may result in electric
shock.
DO NOT TOUCH
WITH WET H ANDS
This product generates
high temperatures. Do
not touch the product
while it is turned on or
immediately after it is
turned off, or burning
may result. Provide
cooling with a fan or
other ventilation if the
product is to be used in
a closed space.
MANDATORY
ACTIONS
Using LDLB-series
Light Units (not water
resistant)
Make sure that the
product is free of moisture
or any liquid. Exposure to
water may result in fire,
electric shock.
DO NOT SUBJ ECT
TO MOISTURE
Connect or disconnect
the light cable only after
turning off the power
supply. Failure to do
so may result in circuit
damage, fire caused
by a minute spark, or
electric shock.
MANDATORY
ACTIONS
If abnormal condition occurs such as fuming, heat, smell,
noise, or so on, stop using the product immediately, and
turn off the power supply. A fire or electric shock may
result if the product is kept used.
MANDATORY
ACTIONS
The following label is attached to the LED light. The color of the label indicates the luminescence color of the product. The name
label species the model name, power consumption, and serial number. Be sure to check the contents before using the product
and handle the label with care. If the label is missing or damaged and the contents cannot be checked, please contact CCS Inc.
Connecting One Light Unit
Daisy-chaining Two or Three Light Units
Maximum Cable Length
Before you connect the Input Cable or Link Cable, make sure that the power supply is turned OFF. Making connec-
tions with the power supply turned ON may result in re, electric shock, or breakdown in the Light Unit.
Handle the Light Units and connectors with care. Do not deform or damage the connectors.
Connect the cables correctly to the Light Units.
Connect a Sealing Cap to any output connectors to which a cable is not connected to maintain water resistance. The
Sealing Cap is connected to the output connector when the Light Unit is shipped.
If the Light Unit is not used for a long period of time with the cable disconnected, attach the Cap to the connector or take
other measures to maintain water resistance.
Observe the following precautions to prevent electrical shock and accidents from water entry.
Using LDLB-IP-series Light Units
Warning
Caution
1
1
2
2
You can daisy-chain up to three Light Units to set the light intensities or turn ON and OFF all of the Light Units together.
The maximum length of the 24-VDC power supply cable depends on the wire diameter, operating mode, and number of con-
nected Light Units. The maximum cable lengths are given in the following table.
One Light Unit Connected: The table gives the maximum length of the Input Cable.
Two or Three Light Units Connected: The table gives the maximum total length of the Input Cable and Link Cables.
Connect the Input Cable to the input connector and connect the leads on the end of the Input
Cable to an external device.
Connect the output and input connectors of the Light Units with Link Cables. Also connect the Input
Cable to the input connector and connect the leads on the end of the Input Cable to an external device.
Turn ON the power supply.
Turn ON the power supply.
Changing from Constant Lighting Mode to Overdrive Mode
1) Set the ON/OFF inputs from the external device to the status for turning ON the Light Unit in Constant Lighting Mode.
Refer to 7. ON/OFF Inputs for information on the ON/OFF input.
2) Change the operating modes in order from the Light Unit that is farthest from the power supply.
(In the above gure, the order would be Light Unit A, Light Unit B, and then Light Unit C.)
Refer to 3. Names and Functions of Parts for information on changing the operating mode. If the setting status of the
ON/OFF inputs is not correct, an overdrive error will occur when you change the operating mode. Also, if the order is not
correct, an overload error will occur.
Changing from Overdrive Mode to Constant Lighting Mode
1) Change the operating modes in order from the Light Unit that is nearest to the power supply.
(In the above gure, the order would be Light Unit C, Light Unit B, and then Light Unit A.)
Refer to 3. Names and Functions of Parts for information on changing the operating mode. If the order is not correct,
an overload error will occur. The setting status of the ON/OFF inputs is not relevant.
To external device
Input Cable
Link CableLink Cable
Light Unit A Light Unit B Light Unit C
Sealing Cap
(for LDLB-IP Series)
When you daisy-chain Light Units, you must use the operating panel on each Light Unit to change between Constant
Lighting Mode and Overdrive Mode. Use the following procedure to change the operating mode.
To external device
Input Cable
Sealing Cap
(for LDLB-IP Series)
Connection Example
LDLB Light UnitExternal Circuit
Variable power supply
(0 to 10 VDC)
24 VDC
* You can adjust the light intensity with a variable power supply or a variable
resistor.
*
If you use a variable power supply, use a power supply with a sinking
output of 3 mA minimum per Light Unit.
Pin 5
Pin 3
If you use a variable resistor, use the one specified below.
One Light Unit: 15 kΩ
Two Light Units: 10 kΩ
Three Light Units: 5 kΩ
Do not exceed an allowable difference of 20% in the overall resistance.
Note:
According to product specifications, the light intensity that is set on
the operating panel may be used when the resistance is near the
maximum value.
If pin 5 (analog input) and pin 3 (common ground) are not connected on the input connector or if 13 to 24 V (maximum in-
put voltage: 26.4) is input, you can use the + and − switches on the operating panel to manually set the light intensity.
If 0 to 10 V is applied between pin 5 (analog input) and pin 3 (common ground) on the input connector, you can set the light
intensity to any of 100 levels with the voltage of the analog input.
The light intensity is displayed on the digital display between 00 and 99
(100 levels).
If you hold down the + or − key for more than 1 second, the value will
change faster.
The manually set light intensity is saved internally even after you turn
OFF the power supply or after you change to external light intensity
control with an analog input.
The light intensity is displayed on the digital display between 00 and 99 (100 levels).
To maintain the light intensity, continue to input a constant voltage. The light intensity that is set by the analog input is not
stored in the Light Unit.
Note: Depending on the number of connected Light Units and the cable length, different light intensities may be set for the same analog
input voltage.
Note: The digital display will show "--" if the light is turned OFF in Constant Lighting Mode. If you turn the light ON and OFF repeatedly over
a short period of time, the digital display may not display numbers correctly.
MODE
OverDrive Continuous : Hold down
L
E
V
E
L
O/D
Con
Input Connector (M12 Plug) Conguration
Setting the Light Intensity with an Analog Input
Voltage (V) between Pin 5 and 3
Light intensity
0
99
20
40
59
79
2 4 6 8 10
5
4
1
3
2
3Set the operating modes of the Light Units.
Operating
Panel Input Connector (M12 Plug)
The digital display shows the light in-
tensity between 00 and 99.
(“00” is the minimum light level.)
You can manually set the light intensity
with the + and
−
switches. Refer to 5.
Setting the Light Intensity on the Oper-
ating Panel for details.
You can change the operating mode
by holding down the + and − switches
at the same time for 3 seconds.
This connector is used to supply
power to the Light Unit and to input
signals to control the light intensity
and turn the light ON and OFF.
Note: There are no restrictions in the installation
direction. You can install the Light Unit up-
side
down or in any other direction. Refer to
10. Dimensions for the installation holes.
Using LDLB-IP-series
Light Units
If you do not use this con-
nector, always attach a
Sealing Cap to it to main-
tain water resistance.
Output Connector (M12 Socket)
If you daisy-chain Light Units, this
connector is connected to the input
connector on the next Light Unit with
a Link Cable.
If you daisy-chain Light Units, you can
supply power, control the light intensity
with an analog input, and use an ON/
OFF input to control all of the Light Units
together. You can also control the light
intensity of the Light Units individually
from the operating panels. You can con-
nect up to three Light Units.
A Link Cable (model: FECB-0.6-M12-
5M-5F, 0.6 m) is available as an option
(sold separately).
The LDLB-IP-series Light Units maintain IP67
water resistance when this Cable is connected.
Input Cables (models: FECB-M12-5F
Series, 1, 2, 3, and 5 m, ying leads) are
available as options (sold separately).
The LDLB-IP-series Light Units maintain IP67
water resistance when this Cable is connected.
Light-emitting Surface
Digital Display
Mode Indicator
(Top panel)
Pin
No. Signal
Cable
FECB-M12-
5F Series
Wire color
1 24 VDC Brown
2 ON/OFF input (NPN) White
3Common ground Blue
4 ON/OFF input (PNP) Black
5
Analog input (0 to 10 V)
Gray
Pin
No. Signal
Cable
FECB-M12-
5F Series
Wire color
1 24 VDC Brown
2 ON/OFF input (NPN) White
3Common ground Blue
4 ON/OFF input (PNP) Black
5
Analog input (0 to 10 V)
Gray
Light intensity 00 01 …49 50 …98 99
Radiant
quantity
Constant Lighting Mode
10% 11% …55% 55% …99% 100%
Overdrive Mode
100% 102% …214% 216% …328% 330%
5
5
4
3
1
2
3
4
2
1
Refer to 9. Optional Products (Sold Sep-
arately) for details on the Link Cable.
Refer to 6. External Control of the
Light Intensity for information on the
analog input.
Refer to 7. ON/OFF Inputs for informa-
tion on the ON/OFF inputs.
Refer to 9. Optional Products (Sold Sepa-
rately) for details on the Input Cable.
Label (Example)
Name label (Example)
The general relationship between the light intensity and the radiant quantity is shown in the following table.
Constant Lighting Mode
You can set the light intensity to any of
100 levels from the operating panel or with
an analog input from the input connector.
You can turn the light ON and OFF with an
ON/OFF input from the input connector.
Overdrive Mode
The mode indicator on the operating
panel will light. A larger current en-
ables a brighter light intensity (100 lev-
els) than in Constant Lighting Mode.
However, the light intensities that you
can set are restricted as shown below.
Refer to 7. ON/OFF Inputs for details.
Operating time
Signal repeat period to light the LEDs
Wire diameter
Number of Light Units connected in Constant Lighting Mode
Number of Light Units connected in Overdrive Mode
123123
AWG16 10 m 10 m 10 m 10 m 5.5 m 2 m
AWG18 10 m 10 m 10 m 8 m 3.5 m 1.5 m
AWG20 10 m 10 m 7 m 5.5 m 2 m Cannot be used.
AWG22 10 m 7 m 4.5 m* 3 m* 1 m* Cannot be used.*
* The wire diameter is AWG22 for the optional (sold separately) FECB-M12-5F-series Input Cables and FECB-0.6-M12-5M-5F Link Cable. If the
maximum length given above is exceeded, shorten the Input Cable or contact CCS.
− switch+ switchDigital display
All manuals and user guides at all-guides.com
all-guides.com

- 2 -
Signal from a Sinking Input (NPN)
You can turn the light ON and OFF with a signal input from the input connector. With these Light Units, you can use a
sinking input (NPN) or a sourcing input (PNP).
Pin 4 Open
Constant Lighting Mode Connection Example
Pin 4 High Voltage
Overdrive Mode
Light Unit status
Pin 2 (NPN)
Lit. Lit.
Low voltage
Open
ON delay time: 55 us max.OFF delay time: 45 us max.
Not lit.
Minimum operating time:
Approx. 100 us
Light Unit status
Pin 2 (NPN)
Lit. Lit.
Low voltage
Open
ON delay time: 55 us max.OFF delay time: 45 us max.
Not lit.
Minimum operating time:
Approx. 100 us
Pin 2 (NPN)
Low voltage
Open
Light Unit status Not lit. Not lit.
OFF delay time: 45 us max.
Lit.
ON delay time: 55 us max.
Minimum operating time:
Approx. 100 us
Pin 2 (NPN)
Low voltage
Open
Light Unit status Not lit. Not lit.
OFF delay time: 45 us max.
Lit.
ON delay time: 55 us max.
Minimum operating time:
Approx. 100 us
LDLB Light UnitExternal Circuit
Pin 4
Pin 3
Pin 2
Transistor (NPN)
open collector
LDLB Light UnitExternal Circuit
5 VDC
24 VDC
Pin 4
Pin 3
Pin 2
Transistor (NPN)
open collector
5 VDC
**
Switch the signal input on pin 2 to turn the light ON and OFF with a signal from a sinking input (NPN). Also, you can input
a high voltage on pin 4 to switch the logic for turning the light ON and OFF. Switch the signal input on pin 4 to turn the light ON and OFF with a signal from a sourcing input (PNP). Also, you can input
a low voltage on pin 2 to switch the logic for turning the light ON and OFF.
* Use an element or switch with a current ow of approximately 1 mA in the external circuit.
Logic Ta ble
Refer to the following table for the low and high voltages.
Logic switching
Pin 4 Open High voltage
Signal input Pin 2 (NPN) Open
Low voltage
Open
Low voltage
Operating
mode
Constant Lighting Mode
Lit. Not lit. Not lit. Lit.
Overdrive Mode
Not lit. Lit. Lit. Not lit.
Logic switching
Pin 2 Open Low voltage
Signal input Pin 4 (PNP) Open
High voltage
Open
High voltage
Operating
mode
Constant Lighting Mode
Lit. Not lit. Not lit. Lit.
Overdrive Mode
Not lit. Lit. Lit. Not lit.
Pin
Signal input status
Range
Pin 2 (NPN) Low voltage 0 to 1.1 VDC
Pin 4 High voltage
20.7 to 26.4 VDC
Pin
Signal input status
Range
Pin 2 Low voltage 0 to 1.1 VDC
Pin 4 (PNP) High voltage
20.7 to 26.4 VDC
Transistor
(NPN)
Pin 2
Pin 3
(ground)
Switch,
relay, etc.
Pin 2
Pin 3
(ground)
Signal from a Sourcing Input (PNP)
Pin 2 Open
Constant Lighting Mode Connection Example
Pin 2 Low Voltage
Overdrive Mode
LDLB Light UnitExternal Circuit
5 VDC
24 VDC
Pin 4
Pin 3
Pin 2
Transistor (PNP)
open collector
*
LDLB Light UnitExternal Circuit
5 VDC
24 VDC
Pin 4
Pin 3
Pin 2
Transistor (PNP)
open collector
*
Pin 4 (PNP)
High voltage
Open
Lit.
Light Unit status Lit.
OFF delay time: 45 us max.
Not lit.
ON delay time: 55 us max.
Minimum operating time:
Approx. 100 us
Pin 4 (PNP)
High voltage
Open
Lit.
Light Unit status Lit.
OFF delay time: 45 us max.
Not lit.
ON delay time: 55 us max.
Minimum operating time:
Approx. 100 us
Light Unit status
Pin 4 (PNP)
Not lit. Not lit.
High voltage
Open
ON delay time: 55 us max. OFF delay time: 45 us max.
Lit.
Minimum operating time:
Approx. 100 us
Light Unit status
Pin 4 (PNP)
Not lit. Not lit.
High voltage
Open
ON delay time: 55 us max. OFF delay time: 45 us max.
Lit.
Minimum operating time:
Approx. 100 us
* Use an element or switch with a current ow of approximately 1 mA in the external circuit.
Logic Table
Refer to the following table for the low and high voltages.
Pin 4
Pin 3
(ground)
Switch,
relay, etc.
Pin 4
Pin 3
(ground)
Transistor
(PNP)
Optional Products (Sold Separately)9
Error Displays
8
If an error occurs, it will be shown on the digital display on the operating panel.
Digital display Status
E1 Overdrive error
In Overdrive Mode, the operating time or the ON signal repeat period limit was exceeded. This
error is shown on the digital display for 3 seconds. The mode indicator on the upper left of the
digital display will ash continuously.
(The mode indicator will stop ashing when you change to Constant Lighting Mode or when you
cycle the power supply.)
E2 Overload error An overload occurred, e.g., four or more Light Units were connected.
Outputting light will be stopped and automatic recovery will be attempted after 3 seconds.
Restrictions in Overdrive Mode
Depending on the set light intensity, the operating time and the repeat period of the signal that lights the Light Unit (i.e., the
ON signal) are restricted. Input ON signals that meet the conditions given in the following table.
*1 If the ON signal exceeds the above operating time (T
L
),
the light will be turned OFF automatically.
*2 If the ON signal is input in less time than the above
period, it will be ignored.
Light intensity Operating time (TL)*1 ON signal repeat period*2
0 to 28 125 ms max. At least 6.7 times the operating time
29 to 99 10 ms max. At least 14.3 times the operating time
If the ON signal is input continuously, the light will repeatedly turn ON and OFF.
Light Unit
status
ON signal
6.7 or 14.3 times T
L
6.7 or 14.3 times T
L
6.7 or 14.3 times T
L
Not lit.
Lit.
Not lit.
Lit. Lit.
Not lit. Not lit.
ON delay time: 55 us max.
T
L
: Operating time
(125 ms max. or 10 ms max.)
: Invalid ON signals
T
L
T
L
T
L
ON delay time: 55 us max. ON delay time: 55 us max.
Common Specications
Specications by Model
Main Specifications
11
Input voltage (rating) 24 VDC
Input voltage (range) 22.8 to 26.4 VDC
Input current (rating)* Constant lighting mode: 1.3A max.
Overdrive mode: 6A max.
Input connector M12 (5 pins, plug)
Output connector M12 (5 pins, socket)
Lighting mode Constant lighting mode, overdrive mode
Inrush current (max.) 6 A from a cold start
Insulation withstand voltage
(input and output-case)
250 VAC for one minute, cutoff current: 10 mA,
500 VDC, 1MΩ min.
Operating temperature
and humidity (indoors only)
Temperature: 0 to 40°C, Humidity: 20% to
85% (with no condensation)
Storage temperature
and humidity
Temperature: −20 to 60°C, Humidity: 20%
to 85% (with no condensation)
Vibration resistance
Acceleration: 19.6 m/s
2
, frequency: 10 to 55 Hz,
cycles: 3 minutes,sweep cycle: for 1 hour
each in X, Y, and Z directions
Shock
Acceleration: 800 m/s2, Application time: 11 ms,
Repetitions: 3 times each in 6 directions
Cooling method Natural air cooling
CE Marking
Safety standard: Conforms to EN62471
EMS standard: Conforms to EN61000-6-2
EMI standard: Conforms to EN61000-6- 4
Environmental regulations
RoHS compliant
Case material Aluminum alloy, resin
Weight 500 g
Accessories Instruction Guide
Model LED
color
Peak wavelength /
Correlated color
temperature (typ.)
Power
consumption
(W)(max.)
Protective
structure
LDLB-300SW-N
White 6100 K 31
-
LDLB-300RD-N
Red 630 nm 24
-
LDLB-IP-300SW-N
White 6100 K 31
Conforms to IP67
(JIS C 0920)
LDLB-IP-300RD-N
Red 630 nm 24
Conforms to IP67
(JIS C 0920)
* Recommended tightening torque: 0.7 N·m
*
*
The dimensions shown on the left include
tolerance. If you mount two Light Units with
their short sides adjacent to each other, you
can separate the centers of the installation
holes by 8 mm to eliminate misregistration.
4 x Ø4.5
(For installation)
313
304
63
3.5
3.5
Sealing Cap: PROT-M12 (PHOENIX CONTACT)
(For LDLB-IP Series)
300 (発光面)
24 (Emitting surface)
10
320
70
11
Bottom view
Rear view
Top vie w
8
32
Side view
8(0.6)
54
8
8
Headquarters
Address any product queries to the following address or to your nearest CCS representative.
* The power supply for daisy-chained Light Units must provide
sufcient output for all of the Light Units.
7
10
7
ON/OFF Inputs
DimensionsON/OFF Inputs (Continued)
Light Unit
status
ON signal
TL
6.7 or 14.3 times TL
Not lit.
Lit. Lit.
Not lit.
Not lit.
Light Unit
status Not lit. Not lit.
ON signal
ON delay time: 55 us max. OFF delay time: 45 us max.
Lit.
TL
Input Connector (M12 Plug) Conguration
5
4
1
3
2
Pin No. Signal
Cable
FECB-M12-5F Series
Wire color
1 24 VDC Brown
2 ON/OFF input (NPN) White
3Common ground Blue
4 ON/OFF input (PNP) Black
5 Analog input (0 to 10 V) Gray
EXCEPT FOR THE EXPRESS WARRANTIES STATED IN THIS DOCUMENT, CCS MAKES NO
ADDITIONAL WARRANTIES, E XPRESS, IM PLIED, OR STATUTORY, AS TO ANY MATTER
WHATSOE VER. IN PARTICUL AR, A NY AN D ALL WARRA NTIES OF MERCHANTABILIT Y
OR FITNESS FOR PARTICUL AR PU RPOSE ARE E XPRESSLY EXCLUDED.
EXCEPT AS EXPRESSLY SET FORTH HEREIN, CCS MAKES NO WARRA NTIES WITH RE-
SPECT TO THE PRODUCTS.
WARR ANT Y PERI OD: TWO YEARS (ONE Y EAR FOR RADIANT QUANTITY), STARTING
FROM CCS I nc. SH IPPING DATE.
CCS Inc. WILL R EPAIR OR R EPLACE THE PRODUCT FREE OF CHARG E IF IT SH OULD
FAIL TO FUNCTION O R IF THE RADIANT QUANTITY OF THE PRO DUCT SHOULD DROP
TO 50% OR LESS OF ITS INITIAL RADIA NT QUANTIT Y WITHIN THE S PECIFIED WARR AN -
TY PERIOD. IF EITH ER OF THESE CONDITIONS OCCURS, PLEASE TAKE THE PRODUCT
TO YOUR CCS SALES REPRESENTATIVE.
WARRANTY TERMS
1 CCS Inc. WILL REPAIR OR REPLACE THE PRODUCT FREE OF CHARGE IF IT SHOU LD
FAIL TO FUNCTION U NDER USE ON OUR SPECIFIED CONDITION IN ACCORDANCE
WITH TH E INSTRUCTION GUIDE AND OTHER WRITTEN CAUTIONS DURING THE INDI-
CATED WARR ANT Y PERIOD OF T WO YE ARS.
2 CCS Inc. WILL REPAIR OR REPLACE THE PRODUCT FREE OF CHARGE IF ITS R ADIANT
QUANTITY SHOULD DROP TO 50% OR LESS OF ITS INITIA L RADIANT QUANTITY UN-
DER USE O N OUR SPECIFIED CONDITION IN ACCORDA NCE WITH THE INSTRUCTION
GUIDE AND OTH ER WRITTEN CAUTIONS DURING THE INDICATED WARR ANTY PERI-
OD OF ON E YEA R.
3 CCS Inc. WILL CHARGE A REPAIR FEE UNDER THE FOLLOWING CONDITION S:
1) IF THE PROD UCT HAS BEEN SUBJECTED TO MISUSE, UN AUTHO RIZED REPAIRS,
OR MODIFICATION FROM ITS ORIGINAL DESIGN.
2)
IF THE PRODUCT HAS BEEN DAMAG ED FROM IMPACTS DUE TO INA PPROPRIATE HAN-
DLING.
3) IF DAMAGE TO THE PRODUCT RESULTS FROM EX TERN AL CAUSES INCLUDING
ACCIDENTS, FIRE, POLLUTIO N, RIOTS, COM MUNICATION FAILURES, E ARTH-
QUAKES, THUNDERSTORMS, WIND A ND FLOOD DAMAG E, OR ANY OTHER ACT OF
PROVIDENCE, OR FROM ANY EX TRAORDI NARY CONDITIONS SUCH AS ELECTRICAL
SURGES, WATER LEAKAGE, CONDENSATION, OR THE USE OF CHEMICALS.
4) IF THE DAMAGE RESULTS FROM CONNECTION TO ANY Control Unit OR TO AN Y EQUIPMENT
WHICH CCS Inc. DOES NOT MANU FACTURE O R DOES NOT SPECIFY FOR US E.
4
CCS ASSUMES NO LIABILIT Y FOR ANY PURCHASER’S SECONDA RY DAMAGE (DAM AGE
OF
EQUIPMENT, LOSS OF OPPORTUNITIES, LOSS O F PROFITS, ETC.) OR ANY OTHER
DAMAGE RESULTING FROM A FAILU RE OF OUR PRODUCT.
THIS WARRA NTY INFOR MATION PROVIDES THE SCO PE OF CC S'S PRODUCT WARR AN-
TY WITHIN THE SPECIFIED PERIOD, AN D DOES NOT INDICATE OR IMPLY ANY FURTH ER
GUAR ANTEE BEYOND THE WARRANTY TERMS.
CONTACT CCS FOR INQ UIRIES OR INFORMATION ON REPAIRS TO THE PRODUCT AF-
TER THE EXPIRATION O F THE WARRA NTY.
NOTE: THE RADIANT QUANTITY REFERS TO THE WATTAGE OF PHYSICAL ENERGY R ADI ATED
FROM AN LED. IT REFERS TO THE RADIATION LUMINOSITY OF THE LED MEASURED
UNDER CONDITIONS SPECIFIED BY CCS OR THE R ADIATION ILLUMINATION OF THE LED
UNDER SPECIFIED IRR ADIATION CO NDITIONS. CCS SPECIFIES THE R ADIANT QUANTITY
FOR EACH LED LIGHT BECAUSE THE MEASUREMENT AND IRR ADIATION CONDITIONS
VARY FROM THE FORM, THE APPLICATION AND THE IRRADIATION WAVELENGTH.
Warranty Information
Copyright© 2016 CCS Inc. All Rights Reserved.
Descriptions in this instruction guide are based on information available as of July 2016. KZ06922-T001-003
Shimodachiuri-agaru, Karasuma-dori, Kamigyo-ku,Kyoto 602-8011 Japan
E-mail : intlsales@ccs-inc.co.jp
Phone : +81-75-415-8284 Fax : +81-75-415-8278
Use our website to nd your nearest CCS representative.
http://www.ccs-grp.com/mvad
C ontent s of this Instruction Guide may be changed without prior notice.
Illustrations used in this Instruction Guide may differ from ac tual products.
CCS maintains the copyright on this Instruction Guide. Unauthorized transfer or reproduction is strictly prohibited.
Instruction Guide and Dimensional Diagrams in PDF or CAD can be downloaded from the CC S website. http://www.ccs-grp.com
Information Required for China RoHS Directive
环保
使用期限 产品
有害物质的名称及含量
铅
(Pb)
汞
(Hg)
镉
(Cd)
六价铬
(C r ( VI ))
多溴联 苯
(PB B)
多溴二 苯醚
(PBDE)
LED 照明
( 本表格依据 SJ/T11364 的规定编制。)
:
表示该有毒有害物质在该部件所有均质材料中的含量均在 GB/T26572 标准规定的限量要求以下。
:
表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 GB/T26572 标准规定的限量要求。
( 注 ) 铅和镉中的“×”,因欧洲 Ro HS 没限定,故用“○”表示。
Usage deadline for environmental protection
The number used in this logo is based on “Management Methods for Restricting Hazardous Substances Used
in Electric and Electronic Products” and related regulations from People’s Republic of China. It shows the
product usage duration in years for environmental protection. After nishing a product usage, the product
needs to be re-used or discarded appropriately following local law and regulations, complying with safety and
usage caution.
Usage Deadline
for Environmental
Protection
Product
name
Names and contents of hazardous substances
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
chromium (Cr(VI))
PBB PBDE
LED
Lights
(This table is made in c ompliance with SJ/T11364 regulations.)
: Indicates that this toxic or hazardous subst ances contained in all the homogeneous
materials for this par t, according to GB /T26572 is within the limit requirement.
: Indicates that this tox ic or hazardous substance c ontained in all the homogeneous materials
for this part, according to GB/ T26572, is over the limit requirement.
*Lead and cadmium are exc luded in EU RoHS.
Names and contents of hazardous substances 产品中有害物质的名称及含量
环保使用期限
此标志的数字是根据中华人民共和国电器电子产品有害物质限制使用管理办法以及有关标准等,表示该产品的环
保使用期限的年数。
遵守产品的安全和使用上的注意,在产品使用后采取适当的方法根据各地法律,规定,回收再利用或进
行废弃处理。
Ø14.8
44 n x 1000 50
(Ø 5.1)
(n=1, 2, 3, 5)
(Unit: mm)
(Unit: mm)
Light Unit (input connector)
(Socket)
Input connector
(Socket)
Output connector
(Plug)
Flying leads
(5 wires, AWG22)
Ø14.8
(Ø 5.1)
Ø14.8
44 600 46.8
Input Cable Link Cable
Model: FECB-n-M12-5F Model: FECB-0.6-M12-5M-5F
This cable is used to supply power to the Light Unit and to input sig-
nals to control the light intensity and turn the light ON and OFF.
Use this cable for daisy-chain connections.
Select the required cable length.
Weight: 50 g max.
Model
FECB-1-M12-5F FECB-2-M12-5F FECB-3-M12-5F FECB-5-M12-5F
Length 1 m 2 m 3 m
5 m
Weight 55 g max. 90g max. 130g max. 210g max.
All manuals and user guides at all-guides.com
This manual suits for next models
5
Other CCS Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

ledscom
ledscom LC-SS-391 installation instructions

SilverStar
SilverStar Show Wash 120 user manual

Power Fist
Power Fist 8002382 user manual

Astral Pool
Astral Pool Mini Skimmer Installation and maintenance manual

IMG STAGE LINE
IMG STAGE LINE BEAM-20LED instruction manual

LIVARNO LUX
LIVARNO LUX 282449 Assembly, operating and safety instructions