TPS Elektronik GmbH * Senefelder Str. 8 *
41066 Mönchengladbach * www.tps-elektronik.de *
[email protected] * +49(0)21 61 - 49 52 6 - 0
CZ3047T
CZ3035T
CZ3036T
Isolator
CZ.CZ3047T.11(S)E-5.0/17.05
M3
8.0
1
2
Mount the module on a 35mm DIN rail
(1) Make the upside of the isolator to the rail;
(2) Push the downside of the isolator towards the rail.
(1) Every product has been tested strictly before delivery.If users find
any abnormality,please contact the nearest agent or our company.
(2) In 5 years from delivery date,if the product performs abnormally
under normal use conditions,we will repair it for free.
(1) Use a screwdriver (edge length≤6mm)insert the metal lock which
at the downside of the isolator;
(2) Push the screwdriver upwards,and pull the metal lock downwards;
(3) Take out the isolator from the rail.
5
4
Connections
(1)The isolators adopt knock-down terminals.
(2)The wires are single or multiple cables with cross section of 0.5
2 2
mm ~2.5mm .
(3)A length of 8mm bared wire is locked by the M3 bolt, As shown in
figure.
Installation
Disassembly
Maintenance
User Manual
Please read the instruction manual carefully before use the product,
and please safekeeping.
Caution
Please check whether the product type on the package accords
to the ordering contract;
Read this manual carefully before installation or using. If there is
something unclear,please dial technic support hotline-400 881 0780;
Supply voltage is 24VDC, 220VAC is forbidden;
Users are not allowed to dismantle or repair the Isolator otherwise
it will induce malfunction.
1
2
3
YEAR
YEAR
WARRANTY
WARRANTY
Add: Building 6, 201 Minyi Road, Caohejing Hi-Tech Park
Songjiang New Industrial Park, Shanghai 201612, P.R. China
Tel : +86-21-64513350 Fax : +86-21-64846984
Email:chenzhu@chenzhu-inst.com
http://www.chenzhu-inst.com
114.5mm×99.0mm×17.5mm(CZ3035T,CZ3036T)
114.5mm×99.0mm×12.5mm(CZ3047T)
1 2 3
Summarize
Specification
Operation Conditions
(1). The air should not contain any medium corrupting the coat of
chrome, nickel and silver. Moreover, violent quiver and impact or any
cause of electromagnetic induction (such as big current or spark, etc.)
must be avoided when using.
(2). Operating temperature: -20℃~+60℃
(3). Storage temperature: -40℃~+80℃
(4). Relative humidity: 10%~90%
Number of channels: 1 (CZ3047T)
1/2(CZ3035T)
2 (CZ3036T)
Supply voltage: 20~35V DC
Current consumption: (at 24V DC supply, 20mA output)
≤40mA(CZ3047T)
≤45mA(CZ3035T)
≤80mA(CZ3036T)
Input: Current: 0/4~20mA
Distribution voltage: 17.5~25V,current 35mA
Maximum current: 35mA
Output: Current: 0/4~20mA
Output loop-powered:
Load resistance: RL
Output accuracy: 0.1%F.S.
Temperature drift: 0.005%F.S./℃
Response time: Reach 90% of final value in 0.5ms
Power supply protection:
Protect the product from reverse supply voltge destroy
Electromagnetic compatibility: According to IEC 61326-1(GB/T 18268)
Dielectric strength:
1500V AC;1minute(among power supply ,input and output )
Insulation resistance:
≥100MΩ;500V DC(among power supply,input,output and the shell)
Weight: Approx.100g(CZ3047T)
Approx.150g(CZ3035T,CZ3036T)
Suitable IS apparatus:
2-wire transmitter,3-wire transmitter, current source
<
<
Ue=12-30V DC
=(Ue-5)/0.02
Application
3-wire
transmitter
2-wire
transmitter
Current
source
1(+) 2(-)
-
11
12
+
4 20mA~
11
12
10
-
+
S
CZ3047T
4 20mA~
-
+10(+)
-
+
DCS P、LC
11(S)
12(-)
4(+)
5(-) -
+
1(+) 2(-)
-
+
10(+)
11(S)
12(-)
Out1
Out2
4(+)
5(-)
3(+)
6(-)
CZ3035T
CZ3036T
-
+
Out1
Out2
1(+) 2(-)
4(+)
5(-)
3(+)
6(-)
10(+)
11(S)
12(-)
7(+)
8(S)
9(-)
4 20mA~
24V DC
4 20mA~
3-wire
transmitter
2-wire
transmitter
Current
source
-
11
12
+
4 20mA~
11
12
10
-
+
S
4 20mA~
-
+
4 20mA~
DCS P、LC
24V DC
-
11
12
+
4 20mA~
11
12
10
-
+
S
4 20mA~
-
+
4 20mA~
-
8
9
+
4 20mA~
8
9
7
-
+
S
4 20mA~
-
+
4 20mA~
3-wire
transmitter
2-wire
transmitter
Current
source
DCS P、LC
24V DC
Dimensions
Analog input distribution isolator, provides isolated power for 2-wire or
3-wire transmitters which located in field. Transfer 0/4~20mA(or current
source) which generated by transmitters and output isolatedly through
loop powered. This product need an independent power supply. The
power supply, input circuit and output are each galvanically isolated.
RL
Ue
-
+
4 20mA~
RL
Ue
-
+
4 20mA~
RL
Ue
-
+
4 20mA~
RL
Ue
-
+
4 20mA~
RL
Ue

This manual suits for next models

3

Other Chenzhu Relay manuals

Chenzhu CZSR8801-8A4B User manual

Chenzhu

Chenzhu CZSR8801-8A4B User manual

Chenzhu CZ3055 User manual

Chenzhu

Chenzhu CZ3055 User manual

Chenzhu CZ3093 User manual

Chenzhu

Chenzhu CZ3093 User manual

Chenzhu CZSR8001-3A1B User manual

Chenzhu

Chenzhu CZSR8001-3A1B User manual

Chenzhu CZSR8401-1A User manual

Chenzhu

Chenzhu CZSR8401-1A User manual

Chenzhu CZSR8201-3A1B User manual

Chenzhu

Chenzhu CZSR8201-3A1B User manual

Chenzhu GS8547-EX User manual

Chenzhu

Chenzhu GS8547-EX User manual

Chenzhu GS8536-EX User manual

Chenzhu

Chenzhu GS8536-EX User manual

Chenzhu GS8572-EX.R User manual

Chenzhu

Chenzhu GS8572-EX.R User manual

Chenzhu GS8512-EX.12 User manual

Chenzhu

Chenzhu GS8512-EX.12 User manual

Chenzhu GS8500 EX Series User manual

Chenzhu

Chenzhu GS8500 EX Series User manual

Chenzhu CZ3383.11 User manual

Chenzhu

Chenzhu CZ3383.11 User manual

Chenzhu CZ3038 User manual

Chenzhu

Chenzhu CZ3038 User manual

Chenzhu CZ3074 User manual

Chenzhu

Chenzhu CZ3074 User manual

Popular Relay manuals by other brands

Pilz PSEN 1.1b-25 operating instructions

Pilz

Pilz PSEN 1.1b-25 operating instructions

AJAX WallSwitch quick start guide

AJAX

AJAX WallSwitch quick start guide

Pilz PZE X4.1P operating manual

Pilz

Pilz PZE X4.1P operating manual

Berker 2912 quick start guide

Berker

Berker 2912 quick start guide

ZIEHL TR 800 Web operating manual

ZIEHL

ZIEHL TR 800 Web operating manual

Mikro DIN330 user manual

Mikro

Mikro DIN330 user manual

LSIS GIPAM 2200 manual

LSIS

LSIS GIPAM 2200 manual

Sel SEL-787 instruction manual

Sel

Sel SEL-787 instruction manual

MULTISPAN VPR 3P manual

MULTISPAN

MULTISPAN VPR 3P manual

Minebea MIS-304-P Mounting instruction

Minebea

Minebea MIS-304-P Mounting instruction

ABB TF140DU installation instructions

ABB

ABB TF140DU installation instructions

Siemens siprotec 7SD5 user manual

Siemens

Siemens siprotec 7SD5 user manual

Enerwave ZWN-RSM2-PLUS installation instructions

Enerwave

Enerwave ZWN-RSM2-PLUS installation instructions

ERL MIT161 APPLICATION AND COMMISSIONING MANUAL

ERL

ERL MIT161 APPLICATION AND COMMISSIONING MANUAL

GE Masoneilan 469 Series Communications guide

GE

GE Masoneilan 469 Series Communications guide

ABB UAF operating instructions

ABB

ABB UAF operating instructions

CD Automation REVO SSR user manual

CD Automation

CD Automation REVO SSR user manual

Siemens SIRIUS 3RF22 Series operating instructions

Siemens

Siemens SIRIUS 3RF22 Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.