CHINESPORT S.p.A.
updated 15/07/2008 1/4
12170 VISIT 1 – 12171 VISIT Nar – 12172 VISIT Mobil – 12174 VISIT 3 – 12179 VISIT 3 Trend – 12186 VISIT 2 Trend – 12187
VISIT Flexion – 12188 VISIT Large
CHINESPORT
spa
Via Croazia, 2
33100 UDINE-ITALY
Tel. 0432621621
Fax 0432621620




  


Head adjustment
lever
Head adjustment
lever
Flexion – Relax – Trendelenburg
Control Selectors
Flexion Control
Selectors
CHINESPORT S.p.A.
2/4 updated15/07/2008
12170 VISIT 1 – 12171 VISIT Nar – 12172 VISIT Mobil – 12174 VISIT 3 – 12179 VISIT 3 Trend – 12186 VISIT 2 Trend – 12187
VISIT Flexion – 12188 VISIT Large
CONTENTS
1.
INTENDED USE.......................................................................................................................................................................... 2
2.
SPECIAL WARNINGS AND LIMITS OF USE.......................................................................................................................... 2
3.
USE............................................................................................................................................................................................... 2
4.
DECLARATION OF CONFORMITY......................................................................................................................................... 3
5.
TECHNICAL SHEETS ................................................................................................................................................................ 3
6.
WARRANTY ............................................................................................................................................................................... 4
1. INTENDED USE
Examination and treatment tables, adjustable for height by means of a low voltage pedal-controlled electric actuator (24V).
Wide head, back adjusting gas-spring servomechanism. Versions 12174, 12179 and 12187 feature a split leg section for the
“FLEXION” and “RELAX” positions. Versions 12179 and 12186 furthermore allow TRENDELENBURG positioning, easy to
obtain even with the patient loaded on the table.
2. SPECIAL WARNINGS AND LIMITS OF USE
The equipment must not be used:
−in an explosive or flammable atmosphere;
−in a corrosive atmosphere or in inclement weather;
−when having been tampered with and/or if the original product has undergone changes.
−Always unplug from the mains:
1. when moving the equipment
2. before working on any electrical parts.
−
Do not damage the pedal unit and power cords (avoid crushing, do not pull the cable when
unplugging, etc.). Check the cable regularly and have it replaced when in doubt.
−Do not spill any liquids over the table’s electrical parts.
−Do not connect the equipment to an electric system that does not comply with the related current
regulations.
−Make sure that the mains voltage is the same as the voltage specified in the equipment's technical data.
−Do not insert body parts in the areas indicated by labels as subject to movement and / or adjustment.
−The equipment must be used on a stable surface and with its feet adjusted.
−Retractable wheels make it possible to move the table without any additional load.
−The radiating therapeutic lamps may damage the upholstery leatherette.
−Corrosive and / or abrasive detergent products may damage the upholstery leatherette.
−Two or more people are required to carry the equipment.
3. USE
−Height adjustment: connect the power cable to the mains and press the leg section controls (hand switch on model 12172)
−Head / back section adjustment: use the gas-spring lever (see drawing).
−Split leg section adjustment: use one of the two gas-spring lateral levers (see drawing).
−Retractable wheel insertion: push the lower lever using the sole of your foot;
to disengage, lift the upper lever using the back of your foot.
Height adjustment for hydraulic version 01070:
To adjust the table height, press the hydraulic piston lever several times using your foot, until reaching the height desired. To go
down, hold the lever up using your foot until reaching the height desired.
Height adjustment for foot rail adjustment version 01441:
To adjust the table height, press and hold down the foot rail, until reaching the height desired. To go down, hold the lever up using
your foot until reaching the height desired.
Warning:
•Do not sit down on the head section.
•The board handling may cause pinching near the hinges.
•Do not release head and leg section adjusting devices when loaded.
•To use the table under proper hygienic conditions, it is advisable to periodically disinfect the leatherette and use
disposable rolls.
DIRECT TELEPHONE NUMBER FOR TECHNICAL SERVICE
(+39) 0432 621699.
Outside of business hours, send a fax to fax No. 0432-621698 or an e-mail (see www.chinesport.it)
CHINESPORT S.p.A.
updated15/07/2008 3/4
12170 VISIT 1 – 12171 VISIT Nar – 12172 VISIT Mobil – 12174 VISIT 3 – 12179 VISIT 3 Trend – 12186 VISIT 2 Trend – 12187
VISIT Flexion – 12188 VISIT Large
4. DECLARATION OF CONFORMITY
Item code - Product name
  


Therapy and / or examination and / or treatment table
Classification
( Art. 8 of Legislative Decree No. 46 of 24/03/1997)
I
Class
(Art 2.2.4-5 of Standard CEI 62.5.)
II
Type
(Art 2.2.24-25-26 of Standard CEI 62.5)
B
The “UNION” tables are made in compliance with Directive 93/42/EEC
CHINESPORT S.p.A.
(Legal Rep)
5. TECHNICAL SHEETS
- = not available
S = standard
O = optional
12170
12171
12172
12188
12174
12179
12187
12186
CHARACTERISTICS
Power supply Primary: 230V-50Hz 1.5A
Secondary: 24V 70VA
Use: Temporary: use 2 minutes – pause 18 minutes
Dimensions See page 1
Minimum Height 48cm
Maximum Height 98cm
Lifting Capacity 180Kg
Access to Lift UP TO 18cm
Weight 70 74 76 77 76 77
Luxury flame-retardant leatherette S
Standard flame-retardant leatherette -
BOARDS
No. of adjustable boards 1 3 2
Head/Back Gas-spring servomechanism
Simultaneous seat – leg rest -
Gas-spring servomechanism
-
Seat -
Gas-spring
servomechanism
-
Back
Gas-spring
servomechanism
-
POSITIONS-POSTURES
Prone position (breathing hole) S
Prone position with negative tilt setting possible on
head section
S
Sitting position with legs extended S
Armchair position (seat tilt) - S -
Bent leg position S -
Flexion position (lumbar relief and drainage) - S -
Trendelenburg position - S - S
ACCESSORIES
Wheel kit O S
permanent
with brake O
Fold-down side rails O -
Foot rail adjustment O - O
Adjustable cervical pillow O
Adjustable roll holder O
Battery charger function S
Emergency back-up battery O
CHINESPORT S.p.A.
4/4 updated15/07/2008
12170 VISIT 1 – 12171 VISIT Nar – 12172 VISIT Mobil – 12174 VISIT 3 – 12179 VISIT 3 Trend – 12186 VISIT 2 Trend – 12187
VISIT Flexion – 12188 VISIT Large
6. WARRANTY
GENERAL AFTER-SALES SERVICE CONDITIONS FOR CHINESPORT ITEMS
The warranty is valid 36 months from the date of delivery.
The warranty does not cover expendable items, rechargeable batteries, and generally all the material subjected to wear, breakdowns caused by knocks, falls, misuse or improper use, accidental
events and damaged caused by transportation. The warranty will automatically be forfeited if the equipment is tampered with.
Repairs on the equipment will be carried out in relation to the breakdown stated.
An estimate must be specifically requested.
Any payment is intended cash on delivery, unless other agreements are made.
For any controversy, the only place of jurisdiction shall be UDINE (ITALY).
Direct service number 0432/524360
REPAIRS UNDER WARRANTY
Repairs under warranty must be specifically requested.
Repairs under warranty are intended at our laboratory and upon previous authorization.
The return shipment for products sent in their original packaging will be made free of carriage.
A fiscal document is required for repairs under warranty; the purchase date indicated must fall within the warranty time period (bill of sale, purchase invoice or receipt).
If the product results perfectly operational when it is checked, the charges for breakdown identification will be debited to the customer in any event.
REPAIRS NOT UNDER WARRANTY
The transportation charges relating to previously-authorized repairs made in our laboratory that are not under warranty, are at the expense of the customer.
We will provide a written quote only for services priced at least € 50 +VAT.
The warranty on a repair, limited to parts replaced during the intervention, is 12 months from the moment the machinery is collected.
If the product results perfectly operational when it is checked, the charges for breakdown identification will be debited to the customer in any event.
REPAIRS MADE AT HOME
In the event repairs are made at the customer’s home, a written request is required indicating the complete details of the person making the request, the type of machine and the breakdown.
The cost per kilometre for the transfer of the technician will be agreed upon in relation to the urgency of the customer.
In the event the machine involved is under warranty, only the cost for the transfer will be charged to the customer.
Time is calculated from the moment the technician leaves our laboratory until he/she returns. The time of his/her return will be estimated based on the time required to get there.
SALE OF SPARE PARTS AND EXPENDABLE ITEMS
The orders must arrive in writing and specify the customer, item and shipping modality as well as the precise fiscal data of the customer.
The minimum order charge is € 26 + VAT. No sales invoices are issued for amounts lower than € 26 + VAT
The order processing time can vary depending on the availability of the material.
Returned parts will not be accepted.
Payment shall be cash on delivery, unless other agreements are made.
-20°
124
68
68 195
+70°
-20°
68
124 195
51
+70°
68 51
-20°
195
68
124
85
+70°
12170-12172 12171 12188
68
140° 33195
68 90
+70°
-20°
+40°
+20°
12174-12179 12179
+20°
124
68
68 195
+70°
-20°
-20°
68
33
33
55
195
68
+55°
+70°
12186 12187

This manual suits for next models

15

Other chinesport Medical Equipment manuals

chinesport TILTTable LT1 User manual

chinesport

chinesport TILTTable LT1 User manual

chinesport ERGO 10 User manual

chinesport

chinesport ERGO 10 User manual

chinesport ARTIPRESS User manual

chinesport

chinesport ARTIPRESS User manual

chinesport Anchor Series User manual

chinesport

chinesport Anchor Series User manual

chinesport 06855 Operating instructions

chinesport

chinesport 06855 Operating instructions

chinesport UnionVisit LV1 User manual

chinesport

chinesport UnionVisit LV1 User manual

chinesport FISIOLASER IRD User manual

chinesport

chinesport FISIOLASER IRD User manual

chinesport Bobath LB3 Series User manual

chinesport

chinesport Bobath LB3 Series User manual

Popular Medical Equipment manuals by other brands

Kinesia HomeView user guide

Kinesia

Kinesia HomeView user guide

natus MADSEN Alpha OAE+ user manual

natus

natus MADSEN Alpha OAE+ user manual

GE HEALTHCARE CARESCAPE Monitor B650 Technical manual

GE HEALTHCARE

GE HEALTHCARE CARESCAPE Monitor B650 Technical manual

Respironics BiPAP Focus Operator's manual

Respironics

Respironics BiPAP Focus Operator's manual

KaWe easy clic user manual

KaWe

KaWe easy clic user manual

GE 750 Clinical Reference Guide

GE

GE 750 Clinical Reference Guide

BM e-POC Series operating manual

BM

BM e-POC Series operating manual

Stephan STAXEL 1,5 Service manual

Stephan

Stephan STAXEL 1,5 Service manual

Leica BIOSYSTEMS CM3600 XP Instructions for use

Leica BIOSYSTEMS

Leica BIOSYSTEMS CM3600 XP Instructions for use

Datascope Passport 2 Service manual

Datascope

Datascope Passport 2 Service manual

EDAN SE-2003 user manual

EDAN

EDAN SE-2003 user manual

Akron GYNAECOLOGY 2 Service manual

Akron

Akron GYNAECOLOGY 2 Service manual

Bard Peripheral Vascular True Instructions for use

Bard Peripheral Vascular

Bard Peripheral Vascular True Instructions for use

Otto Bock 50P12 Instructions for use

Otto Bock

Otto Bock 50P12 Instructions for use

Bittium NeurOne user manual

Bittium

Bittium NeurOne user manual

Sunrise Medical TRU-TRAC TT-92B Series operating instructions

Sunrise Medical

Sunrise Medical TRU-TRAC TT-92B Series operating instructions

Drive 15561 Owner's assembly and operating manual

Drive

Drive 15561 Owner's assembly and operating manual

Hausmann 1396 Operation and service guide

Hausmann

Hausmann 1396 Operation and service guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.