CRL JACKSON OVERHEAD CONCEALED DOOR CLOSER
13
crlaurence.com | usalum.com
TOP ARM ASSEMBLIES
CENTER-HUNG DOOR CLOSER TOP ARM ASSEMBLIES
CAT. NO. DESCRIPTION RAIL TYPE
20400B CRL Jackson Type "S" Side Load Center-Hung 1/2" (13 mm) Deep Top Rail
202000 CRL Jackson Type "A" End Load Center-Hung 1" (25 mm) Deep Top Rail
202010 CRL Jackson Type "PT" End Load Center-Hung 7/8" (22 mm) Deep Top Rail
202085 CRL Jackson Type "K" End Load Center-Hung 5/8" (16 mm) Deep Top Rail
CRL8010AS CRL Jackson Short End Load Center-Hung For use with CRL Wedge Lock Door Rails
20510 CRL Jackson Wood Door Side Load Center-Hung 5/8" (16 mm) Depth Mortised Rail
(Mortised Channel Included)
202090 CRL Jackson Wood Door End Load Center-Hung 3/4" (19 mm) Depth Mortised Rail
(Mortised Channel Included)
CLOSER SELECTION CHART
CLOSER MAXIMUM INTERIOR DOOR MAXIMUM EXTERIOR DOOR
Adjustable Spring 3'-6" (1067) 3'-0" (914)
Light Duty Spring 3'-6" (1067) 3'-0" (914)
Regular Duty Spring 3'-6" (1067) 3'-0" (914)
Heavy-Duty Spring 4'-0" (1219) 3'-6" (1067)
SPRING POWER
ADJUSTMENT DATA
Closer leaves factory set at size LD
for a 3'-0" (914 mm) door.
To change opening force 1 size
takes approximately 4 turns
– Clockwise to increase
– Counter-Clockwise to decrease
APPROXIMATE OPENING FORCE IN POUNDS
CLOSER CENTER HUNG OFFSET SLIDE-ARM *
2/6 x 7/0 3/0 x 7/0 3/6 x 7/0 4/0 x 7/0 2/6 x 7/0 3/0 x 7/0 3/6 x 7/0 4/0 x 7/0
Adjustable Spring N/A N/A
Light Duty Spring 10 8 6 5 14 12 10 8
Regular Duty Spring 12 10 8 6 17 14.5 13 11
Heavy-Duty Spring 17 15 13 11 N/A 19 17 15
= Adjustable opening force 5 lbs. to 8 lbs. for barrier-free applications for door width noted.*
N/A = Application not recommended.
NOTE: Readings are in pound force required to open door and are taken at the lock stile to full degree of opening.
* IMPORTANT: The use of an Offset Slide-Arm will add 2 to 4 pounds of opening force due to track friction and therefore
may not allow A.D.A. required opening forces and still provide adequate spring power to control and close
the door.
* WARNING: Although A.D.A. Series Closers comply with A.D.A. specied opening forces, they might not provide
adequate spring power to control and close the door due to varying site conditions and door sizes.
CENTER-HUNG INSTALLATION