WATER DETECTOR
ART. 30009009
Specifications:
• Relay output: NC / NO selectable, 1A-120V AC / 1A-24V DC (not inducti e)
• External terminal length: 35mm max
• Case: ABS, white
• Length for additional remote sensors: 100m max
• Additional remote sensors: 8 max
• Power supply: 12V DC
• Current absorption: 20mA max (15mA in stand by)
• Dimensions (W x H x D): 60 x 90 × 25 mm
Installation:
• Open the co er of the water detector
• Fix the water detector on the wall near the floor as much as possible
• Loosen the screws that lock the terminals and adjust them at the height you want
• Tighten the screws to lock the terminals
• Make the electrical connections
• Close the co er of the detector
Note: to connect the remote sensors, we suggest using cable of optimal (two conductors of 0.5 mm
2
) to a oid
that the cable installed in humid atmosphere can create leakage damages to the operation of the de ice.
Ideal for water le el detector, tank filling check,
pipes breaking,