CONDTROL IR-T3 User manual



3
IR-T
3
CONDTROL
FUNCTIONS/APPLICATIONS 4
SET 4
SPECIFICATIONS 5
INSERT/REPLACE BATTERIES 6
SWITCH ON/OFF THE PRODUCT 6
PRODUCT DESCRIPTION 7
PRODUCT SETTINGS 9
OPERATION 10
SAFETY REGULATIONS 14
CARE AND MAINTENANCE 15
UTILIZATION 16
WARRANTY 17
EN: CONTENTS

4
User manual
INFRARED THERMOMETER
IR-T
3
CONDTROL
Congratulations on your purchase of infrared thermometer IR-T3 CONDTROL.
Safety instructions can be found in the end of this user manual and should be carefully read
before you use the product for the first time.
FUNCTIONS/APPLICATIONS
Infrared thermometer IR-T3 is designed to measure object’s surface temperature by
noncontact method(IR) and contact (TK) technology. It can be used to measure the surface
temperature of hard-to-reach objects like electrified equipment or moving objects at a
distance.
IR-T3 is equipped with an ergonomic and shock resistant casing, an intuitive interface, laser
pointer, scan mode and lots of analytic functions.
The principle of non-contact temperature measurement is based on measuring the intensity of
infrared radiation of the object’s surface.
SET
Infrared Thermometer 1 pc.
Power supply (9V) 1 pc.
Type-K probe 1 pc.
Pouch 1 pc.
User manual 1 pc.

5
User manual
INFRARED THERMOMETER
IR-T
3
CONDTROL
SPECIFICATIONS
IR Range -50...10500C
0F
TK Range -50...13700C
0F
Accuracy IR: -50…000F±40C0F
0…50000F0C/3.60F
500…105000F0C/3.60F
TK: -50...137000F±1.5% ±10C0F
D:S 30:1
Resolution 0.10C(0.10F)<1000, 10C(10F) >1000
Response Time
Spectral Response
Emissivity 0,1…1,0
Operating Temperature 00C…50000F
Relative Humidity Operation: 10...95%
Storage Temperature 000F...1400F
Weight / Dimensions (L*W*H)
Power Supply
Tripod thread 1/4’’
Additional functions MAX, MIN, DIF, AVG record
Record

6
User manual
INFRARED THERMOMETER
IR-T
3
CONDTROL
1. Remove the screw
2. Open the battery cover
INSERT/REPLACE BATTERIES
When the low battery icon appears,
replace the meter’s battery.
Open the battery cover, replace the 9V
battery and close the cover.
SWITCH ON/OFF THE PRODUCT
Pull and hold the Trigger to turn the meter on, the «SCAN» icon will appear and begin testing.
The meter will automatically shut off after 35 seconds.

7
User manual
INFRARED THERMOMETER
IR-T
3
CONDTROL
1 - Laser pointer
3 - K-type probe interface
4 - keypad
5 - Measurement trigger
6 - Battery cover
7 - Battery cover fixation screw
9 - Tripod thread 1/4’’
10 - LCD Display
PRODUCT DESCRIPTION

User manual
INFRARED THERMOMETER
IR-T
3
CONDTROL
Display
1 - Measurement Icon
3 - Laser Icon
4 - Backlit Icon
5 - Trigger Lock
6 - 0C / 0F Icon
10 - Function values line for the MAX, MIN, DIF,AVG, HAL, LAL. and REC
11 - Low Battery Icon
13 - Low Alarm Icon
14 - High Alarm Icon
15 - High Alarm Set
19 - Current temperature value line

9
User manual
INFRARED THERMOMETER
IR-T
3
CONDTROL
PRODUCT SETTINGS
1) In “HOLD” Mode, press button to turn on/off backlight.
3) To switch the temperature In Measurement Mode,
- Press down button for 0C
- Press up button for 0F
4) There are 3 adjustable options :
- Emissivity
- Low Alarm Set
- High Alarm Set
After power on the meter, keep pressing button until icon flashes on the screen,
then loose button , enter into Emissivity Mode, press button to adjust emissivity
value, then keep pressing button return to the normal measurement mode. (After
entering into Emissivity Mode, momentarily press button can set the High/Low alarm
value ).

10
User manual
INFRARED THERMOMETER
IR-T
3
CONDTROL
OPERATION
Pull and hold the Trigger to turn the meter on, the «SCAN» icon will appear and begin testing.
Release the trigger, the «HOLD» icon will appear, and the reading will be held for several
The laser is designed for aiming only; it can be shut off while operating in short distance to
save the battery.
If the meter used in an ambient temperature with wide temperature change, awaiting it at least
30 minutes to adjust it.
Vapor and fog affect the readings.
Not recommend for measuring shiny or polished metal surfaces like stainless steel, aluminum,
etc.
Additional functions
Thermometer IR-T3 is equipped by several additional functions. It’s icon will appear on the
LCD display.
Measurement or calculation result will appear in the function values line of the LCD display.
Press button to choose REC, MAX, MIN, DIF, AVG, High/Low Alarm values and TK
measurement.
- minimum measured value - «MIN»;
- maximum measured value - «MAX»;
- the maximum difference between the maximum and minimum measured values - «DIF»;
- medium-arithmetic value - «AVG»;
- thermocouple readings - «TK». You need to connect the thermocouple. If the thermocouple
is not connected, device temperature to be measured;
- High/low alarm set «HAL»/»LAL».
The function is designed to facilitate temperature control of the object. If the measured
temperature is Higher/lower, IR-T3 thermometer give a loud signal and alarm icon appear on
the display. High/Low values are adjustable at the Product settings ;

11
User manual
INFRARED THERMOMETER
IR-T
3
CONDTROL
Lock Function
After power on the meter, lock the unit on for
continuous measurement by sliding the switch to right
LOCK position.
After finish the measurement, slide the switch to
left UNLOCK position.(After entering into continuous
measurement, the trigger button will not work.)
Emissivity
All objects emit thermal energy. Emitted energy
quantity depends on the surface temperature
and object emissivity. The product can measure
emission on the surface of object and calculate
object temperature. Objects with different surfaces
but with the same temperature can emit
different quantity of thermal energy. Many objects
(e.g. coated metal, wood, water, skin and
texture) possess high emissivity (0,9 and more), and
emit more energy than glossy surfaces
and uncoated metal, because their emissivity is less
than 0,6. Adjustment of emissivity helps
to take this feature into consideration and minimize
inaccuracy of temperature measurement.
lock button

User manual
INFRARED THERMOMETER
IR-T
3
CONDTROL
Emissivity Table
Substance Thermal
emissivity
Substance Thermal
emissivity
Aluminium 0.30 Glass 0.90 - 0.95
Asphalt 0.95 Iron oxides
Concrete 0.95 Lacquer
Leather 0.95 Plastic
Ceramic 0.95 Paper 0.70 - 0.94
Copper 0.50 Sand 0.90
Brick 0.90 Rubber 0.95
Carbon Timber 0.94
Fatlute 0.94 Textiles 0.94
Frozen food 0.90 Lead 0.50
Hot food 0.93 Marble 0.94
Ice Cloth(black)
Snow 0.90 Plaster
Human skin Water 0.93

13
User manual
INFRARED THERMOMETER
IR-T
3
CONDTROL
Field of View
As distance (D) from the object increases, the spot size (S) of the area measured by the unit
becomes larger.
The minimum measurement spot size at the intersection of the two lasers is 760 mm from the
instrument to the measured surface. The spot size increases in the ratio of 30:1. To determine
the size of the measurement spot (S) you need the distance from the instrument to the target
(D) to divide by 30.
Laser pointers are a guideline to determine the size and position of the measurement spot.
Spot
Distance
0.4in (10mm)
12in (300mm)
InfraRed Laser
1.2in (30mm)
36in (900mm)

14
User manual
INFRARED THERMOMETER
IR-T
3
CONDTROL
SAFETY REGULATIONS
The user manual should be read carefully before you use the product for the first time.
Unintended use of the product can be dangerous for human’s health and cause serious injury.
Keep this user manual. If the product is given to somebody for temporary use, be sure to
enclose user manual to it.
- Do not misuse the product
- Do not remove warning signs and protect them from abrasion, because they contain
information about safe operation of the product.
The device b
wavelength.
- Do not look into the laser beam or its reflection, with
unprotected eye or through an optical instrument. Do not point the laser beam at people or
animals without the need. You can dazzle them.
- To protect your eyes close them or look aside.
- It is prohibited to disassemble or repair the product yourself. Intrust product repair to
qualified personnel and use original spare parts only.
- Do not use the product in explosive environment, close to flammable materials.
- Avoid heating the batteries to avoid the risk of explosion and electrolyte leakage. In case of
liquid contact with skin, wash it immediately with soap and water. In case of contact with eyes,
flush with clean water during 10 minutes and consult the doctor.

15
User manual
INFRARED THERMOMETER
IR-T
3
CONDTROL
CARE AND MAINTENANCE
Attention! The instrument is a precision device and requires careful handling. The following
recommendations will extend the life of the product:
- Do not point the product at the sun
- Protect the product from bumps, falls, excessive vibration; do not let liquids, construction
dust and foreign objects get inside the product.
- Do not expose the product to extreme temperatures.
- If liquids get inside the product first remove the batteries, then contact a service center.
- Do not store or use the product under high humidity conditions for a long time.
- Clean the product with soft wet cloth.
- Keep device optics clean and protect it from mechanical damage.
excessive mechanical or other impact, before and after taking important measurements.

16
User manual
INFRARED THERMOMETER
IR-T
3
CONDTROL
UTILIZATION
Expired tools, accessories and package should be passed for waste recycle. Please send the
product to the following address for proper recycle:
CONDTROL GmbH
Wasserburger Strasse 9
Germany
Do not throw the product in municipal waste!
must be collected separately and submitted to environmentally friendly recycle of wastes.

17
User manual
INFRARED THERMOMETER
IR-T
3
CONDTROL
WARRANTY
All CONDTROL GmbH products go through post-production control and are governed by the
following warranty terms. The buyer’s right to claim about defects and general provisions of
the current legislation do not expire.
1) CONDTROL GmbH agrees to eliminate all defects in the product, discovered during the
warranty period, that represent the defect in material or workmanship in full volume and at
its own expense.
(see the original supporting document).
3) The Warranty does not cover defects resulting from wear and tear or improper use,
malfunction of the product caused by failure to observe the instructions of this user manual,
untimely maintenance and service and insufficient care, the use of non-original accessories
and spare parts. Modifications in design of the product relieves the seller from responsibility
for warranty works. The warranty does not cover cosmetic damage, that doesn’t hinder normal
operation of the product.
4) CONDTROL GmbH reserves the right to decide on replacement or repair of the device.
5) Other claims not mentioned above, are not covered by the warranty.
6) After holding warranty works by CONDTROl GmbH warranty period is not renewed or
extended.
7) CONDTROL GmbH is not liable for loss of profit or inconvenience associated with
a defect of the device, the rental cost of alternative equipment for the period of repair.
This warranty applies to German law except provision of the United Nations Convention on
contracts for the international sale of goods (CISG).
In warranty case please return the product to retail seller or send it with defect description to
the following address:
CONDTROL GmbH
Wasserburger Strasse 9
Germany

Руководство пользователя
ИНФРАКРАСНЫЙ ПИРОМЕТР
IR-T
3
CONDTROL
Перед первым использованием прибора, пожалуйста, внимательно ознакомьтесь
с правилами безопасности, приведенными в конце данного руководства по
эксплуатации.

19
Руководство пользователя
ИНФРАКРАСНЫЙ ПИРОМЕТР
IR-T
3
CONDTROL
-50...10500C
0F
-50...13700C
0F
00F±40C0F
0…50000F0C/3.60F
500…105000F0C/3.60F
T: -50...137000F±1.5% ±10C0F
30:1
0.10C(0.10F)<1000, 10C(10F) >1000
0,1…1,0
00C…50000F
000F...1400F
1/4’’