11
Supported models
• C4-T4T8-xx 8" Tabletop Touchscreen (black or white)
• C4-T4T10-xx 10" Tabletop Touchscreen (black or white)
Introduction
The Control4® T4 Series Tabletop Touchscreens oer complete
system control in an elegant, compact, and portable design. The
touchscreens are equipped with a full capacitive screen, audio
and video Intercom (with the built-in camera) using SIP, and
more.
This touchscreen can be located anywhere, and the convenient
recharging station enables it to be used as either a tabletop or
portable interface. The touchscreen uses an AC power adapter
for power and Wi-Fi for network connectivity.
Note: 802.11b is not recommended for video intercom.
We recommend using Wireless-N. See “Specifications”
for more information.
Box contents
• Tabletop Touchscreen
• Recharging station
• Recharging station power cord
Accessories available for purchase
• Tabletop Permanent Mount Kit (C4-T4PMNT)
• T4 Touchscreen Tabletop 8" Base (C4-T4TBS8)
• T4 Touchscreen Tabletop 10" Base (C4-T4TBS10)
Warnings
Warning! This product must be grounded in accordance
with the National Electrical Code (NEC) requirements.
Avertissement ! Ce produit doit être fondu selon les
conditions électriques nationales de code (NEC).
Caution! Do not place the touchscreen near sources of
heat or expose to direct sunlight for an extended time.
Avertissement ! Ne placez pas l’unité près des sources
de chaleur ou exposition pour diriger la lumière du soleil
pendant une période prolongée.
Caution! This product generates heat. The room must
have adequate ventilation or the ability to dissipate heat
eectively.
Avertissement ! Ce produit produit de la chaleur. La salle
doit avoir à ventilation proportionnée ou la capacité
d’absorber la chaleur ecacement.
Caution! Use this product only in dry locations.
Avertissement ! Employez ce produit seulement dans
des endroits secs.
Caution! Do not use pens or sharp objects to navigate
or make selections on the touchscreen. To select an item
or scroll through a list, use your fingertip.
Avertissement ! N’employez pas les stylos ou les objets
pointus pour diriger ou pour faire des choix sur l’écran.
Pour choisir un article ou un rouleau par une liste,
employez votre bout du doigt.
Caution! Improper use or installation can cause
DAMAGE OF PROPERTY.
Avertissement ! L’utilisation ou l’installation inexacte
peut causer DAMAGE DE PROPRIÉTÉ.
Important! Using this product in a manner other than
outlined in this document voids your warranty. Further,
Control4 is NOT liable for any damage incurred with the
misuse of this product. See “Warranty.”
T4 Series Tabletop Touchscreens
Installation Guide
2
Specifications and requirements
Specifications
Model Numbers C4-T4T10-BL, C4-T4T10-WH
C4-T4T8-BL, C4-T4T8-WH
Screen
Resolution: 1920 × 1200
Capacitive touch
Camera: 720p
Wireless network
802.11b/g/n 2.4 GHz
802.11a/n/ac 5 GHz
Security: WEP, WPA/WPA2 PSK, 802.1x EAP, PEAP
Notes: (1) While technically the touchscreen can use 802.11b,
802.11b is not supported. (2) 802.11n is recommended for
best performance. Even with 802.11n, broadcasting to
several devices will degrade Video Intercom response time
and images. Broadcasting to additional devices will further
degrade performance. See “Wireless Network Limitations.”
Power supply
100-240V AC, 50/60 Hz
International adapters included
Charging base connections: 5V DC power
Dimensions
(W×H×D)
8" Touchscreen: 178 × 130 × 19 mm (7.0 × 5.1 × 0.75")
8" Base: 106 × 79 × 56 mm (4.17 × 3.11 × 2.21")
10" Touchscreen: 245 × 172 × 23 mm (9.65 × 6.77 × 0.91")
10" Base: 115 × 102 × 66 mm (4.53 × 4.02 × 2.60")
Weight
8" Touchscreen: 1.05 lb (0.47 kg)
8" Charging base: 1.4 lb (0.64 kg)
10" Touchscreen: 1.35 lb (0.60 kg)
10" Charging base: 1.05 lb (0.46 kg)
Operating
temperature
0 to 40 ˚C (32 to 104 ˚F)
Storage
temperature
-20 to 70 ˚C (-4 to 158 ˚F)
Requirements
• A controller fully installed and configured with Control4
OS3.2.1 or newer.
• A wireless network (IEEE 802.11b/g/n) must be installed and
available with a wireless access point (WAP). Security can be
WEP, WPA/WPA2 PSK, 801.1x EAP, or PEAP.
• For AC power, you must have access to an AC power outlet
(AC power adapter included).
Views
Front
E
A B C
D
A Camera LED
B Camera
C Light sensor
D Stereo microphones
E 8"or 10" diagonal, capacitive 1920 × 1200 display
Back (with charging station)
C
F
A B
D
E
G
A Power button. Press to enter or exit battery saving mode,
press and hold to turn off or restart, or press and hold for 10
seconds to power off.
B Reset pinhole. Press to reset, or press and hold to reset and
restore factory defaults.
C Docking connector
D Volume buttons
E Speakers
F Charging station base
G 5V DC power connector
3
Touchscreen placement
Place the touchscreen’s charging station on any level surface
near a power outlet. For more information on mounting the
touchscreen, see “Portable” under “Mounting options” below.
Note: Consider the angle of the touchscreen’s camera
and the sitting or standing position of the people who
will use it while it’s on the charging station.
Connect power and Wi-Fi
The touchscreen uses a Wi-Fi network connection, so it can be
positioned anywhere in the home with a strong WiFi signal and
access to a power outlet.
To connect power and Wi-Fi:
1 Place the touchscreen’s charging station near a power outlet.
2 Connect the AC power adaptor to a power outlet and the
charging station.
3 Make sure you have Wi-Fi working in the home.
If a home requires a large number of Wi-Fi video intercom
devices, ensure that you have a robust Wi-Fi network
(possibly consisting of multiple access points).
Connection notes: (1) Video Intercom. Although
this device supports 802.11b/g/n, 802.11 b is not
recommended for Video Intercom use. (2) We
recommend Wireless-N for best performance.
Wireless network limitations: Many Wi-Fi access points
handle Multicasts (Wi-Fi simultaneously sent to multiple
devices, for example, when the touchscreen broadcasts
video to all stations) by slowing down transmission
speed to the 1 Mb basic rate. This can cause overall
Wi-Fi congestion in the Wi-Fi network during the
broadcast. Video Intercom response times and images
may degrade at each device.
Connect to Wi-Fi
To set up Wi-Fi on the touchscreen:
1 After the touchscreen starts up, tap Network. The network
configuration page opens.
2 Under Wi-Fi, tap or slide OFF/ON to enable Wi-Fi, then tap
the Wi-Fi field to open a list of available networks.
3 Tap the network name you want to connect to.
4 Tap the Password field, then use the on-screen keyboard to
type the password (if required).
Note: If you need to enter a static IP address, follow the
instructions under “To set a wireless static IP address”
below before proceeding.
5 Tap Connect.
If you don’t see the network you want:
1 Tap +, then tap the Network SSID field and type the SSID
(name) of the network by using the on-screen keyboard.
2 Tap the Security field, then select the type of security to use.
3 Tap the Password field, then use the on-screen keyboard to
type the password (if required).
Note: If you need to enter a static IP address, follow the
instructions under “To set a wireless static IP address”
below before proceeding.
4 Tap Save. The new network is added to the bottom of the
network list.
To set a wireless static IP address:
1 Scroll down and tap Show advanced options.
2 Tap IPsettings, then tap Static.
3 Select each box one at a time and use the on-screen
keyboard to type the:
• IP address
• Gateway
• Network prefix length
• DNS 1 (preferred)
• DNS 2 (alternate)
Add and configure in Composer Pro
After the touchscreen is installed and appears on the home
network, use Composer Pro to add it to the Control4 system and
configure it.
Use the Composer Pro System Design and Connections views to
add and configure this device.
To add and configure a T4 touchscreen to a project:
1 Add the T4 Tabletop Touchscreen driver to your project.
2 Identify the device to the project, select the touchscreen in
Composer Pro’s Connections > Network view, click Identify,
then tap Identify on the touchscreen.
3 To configure the properties, select the touchscreen in the
System Design view, then view and change the properties in
the Properties pane as needed.
Properties include:
• Network Connection—Reports the touchscreen’s current
network connection type.
• Back Light—Click the arrows or type numbers to set the
light level, then click Set.
Advanced properties include:
• Enable Camera—Allows you to enable or disable the
camera.
Intercom (nested under the touchscreen) properties:
• Appearance—Select to hide the touchscreen from
appearing in Navigators as an available device.
• Behavior—Select the modes you want this touchscreen to
support.
• Audio Control—Select the volume of individual audio
settings.
4
• Sip Information—Information for integrating the
touchscreen into your SIP/VoIP system.
• Custom Buttons—Select to enable and label the two
available custom buttons.
• Alternate Camera—Select to use an external camera for
the video associated with the touchscreen, for example, a
security camera mounted to the side of the entrance and
pointing at the door.
Mounting
Place the charging station on any level surface. While positioning
the touchscreen, consider the angle of the touchscreen’s camera
and the position of the people who will use it while it’s on the
charging station.
Portable use
You can set the touchscreen onto the charging station for
recharging and tabletop use, and lift the screen from the
charging station for portable use (like a tablet).
Tip: For easy and smooth separation of the touchscreen from the
charging station, slightly rotate the touchscreen while lifting it.
Permanent mount
You can mount a touchscreen permanently to a surface, such
as a table, using the optional T4 Tabletop Permanent Mount Kit
(C4-T4PMNT).
1 Peel o the plastic cover on the touchscreen’s docking
connector recess.
2 Use the Phillips-head flat screws provided in the kit to
install the permanent-mount adapter into the touchscreen’s
docking connector recess.
3 Remove the charging station’s bottom cover by removing
the two screws shown.
Base
screws
4 Save the cover and screws.
5 Using a #2 Phillips screwdriver inserted from the base of
the charging station, remove the two screws that secure
the charging station’s top docking connector cover (do not
remove the screw holding the PCB), then discard the two
screws you removed.
6 Screw the base to the back of the touchscreen as shown
using the new threaded, black screws provided. DO NOT
ATTEMPT TO USE THE ORGINAL SCREWS REMOVED
IN STEP 5 OR YOU WILL PERMANANTLY DAMAGE THE
THREADS ON THE TOUCHSCREEN.
7 Reinstall the base bottom cover.
5
8 To install the charging station permanently into a table
or countertop, remove the small rubber discs covering the
threaded holes in the base.
9 Install the threaded posts (all thread) into the base of the
charging station.
10 Using the template and a 1/4" drill, drill two holes into the
surface where you are mounting the touchscreen. Maximum
surface thickness is 32 mm (1.25").
11 Mount the charging station assembly into the mounting
holes and secure it in place using a washer and nut.
Troubleshooting
To power cycle the touchscreen:
1 Press and hold the (power) button for several seconds
until the touchscreen turns o.
2 Press and release the (power) button again to turn on.
To perform a factory data reset:
1 On the touchscreen’s main screen, tap Settings, System Info,
then Factory data reset.
- OR -
If the touchscreen has not yet been configured, tap About,
then Factory data reset.
- OR -
To reset without using the display screen:
a Dock the touchscreen onto its charging station.
b Press and hold the volume up button while using a
straightened paper clip to press and release the reset
button.
Reset hole
c Keep holding down the volume up button until the icon
below appears on the screen, then release the button.
d A message appears, indicating that data is being erased.
control4.com | 888.400.4070
Additional resources
The following resources are available for more support.
• Knowledgebase and forums on Tech Community
• Technical Support
• Control4 website:
www.control4.com
• Composer documentation available at
ctrl4.co/docs
.
Warranty and legal notices
Find details of this product’s 2-Year Limited Warranty at
snapav.com/warranty
, or request a paper copy from Customer
Service at (866) 424-4489. Find other legal resources, such as
regulatory notices and patent information, at
snapav.com/legal
.
More help
For the latest version of this document, open this URL or scan
the QR code on a device that can view PDFs.
200-00683-A
2020-10-09 MS
Copyright ©2020, Wirepath Home Systems, LLC. All rights reserved. Control4 and Snap AV and their respective logos are registered trademarks or trademarks of
Wirepath Home Systems, LLC, dba “Control4” and/or dba “SnapAV” in the United States and/or other countries. Snap AV and Wirepath are also registered trademarks
or trademarks of Wirepath Home Systems, LLC. Other names and brands may be claimed as the property of their respective owners. All specifications subject to change
without notice. A
LATEST VERSION OF THIS DOCUMENT
ctrl4.co/t4-tabletop-ig
T4 DATA SHEET
ctrl4.co/t4-ds
11
Supported models
• C4-T4IW8-BL 8" T4 In-Wall Touchscreen, Black
• C4-T4IW8-WH 8" T4 In-Wall Touchscreen, White
• C4-T4IW10-BL 10" T4 In-Wall Touchscreen, Black
• C4-T4IW10-WH 10" T4 In-Wall Touchscreen, White
Introduction
The Control4® T4 Series 8- and 10-inch In-Wall Touchscreens oer
complete system control in an elegant and compact design. The
touchscreens are equipped with a full capacitive screen, audio
and video Intercom (with the built-in camera) using SIP, and
more.
This touchscreen works great in either new construction or
retrofit installations. For power and network connectivity, choose
from three options:
• Ethernet with PoE—The Ethernet network connection is
provided through the PoE Injector. No additional wiring is
needed.
• Ethernet with AC—Connect the touchscreen to one of the
LAN ports on the gateway/router using an Ethernet cable.
AC power is used to power the touchscreen.
• WiFi with AC—The internal Wi-Fi will communicate with the
LAN’s wireless AP, so no additional network wiring is needed.
AC power is used to power the touchscreen.
Note: 802.11b is not recommended for video intercom.
We recommend using Wireless-N. See “Specifications”
and “Power and Network Installation Options” for more
information.
Box contents
• 8"or 10"T4 In-Wall Touchscreen
• Power box (to power the touchscreen)
• Two screws (to attach the power box to the wall box)
• Set screw (to secure the touchscreen to the power box)
• Set screw tool (3/32" hex wrench)
Accessories available for purchase
• Pakedge 802.3at/af Gigabit PoE+ Injector (PI-30AT), or
Araknis Networks Gigabit PoE+ Injector
(AN-ACC-INJ-POE-30W), each sold separately.
• Wall box options (sold separately)—Metal and plastic, for
new construction or retrofit installations.
• In-Wall Touchscreen Wall Box Kits - New Construction
• Plastic (C4-NWB57C-P)
• Metal (C4-NWB57C-M)
• In-Wall Touchscreen Wall Box Kits - Retrofit
• Plastic (C4-RWB57C-P)
• Metal (C4-RWB57C-M)
For wall box installation details, see:
• In-Wall Touchscreen Wall Box Installation Guide-New
Construction (
ctrl4.co/wallbox-new
)
• In-Wall Touchscreen Wall Box Installation Guide-Retrofit
(
ctrl4.co/wallbox-retro
)
8"and 10"T4 Series In-Wall Touchscreen
Installation Guide
2
Warnings
Warning! The touchscreen must be protected by an
external circuit breaker or a fuse rated at 6A maximum
when used in Europe.
AVERTISSEMENT ! Pour réduire le risque du feu ou de
choc électrique, n’exposez pas cet appareil à la pluie ou
à l’humidité.
Warning! Do not place the touchscreen near sources of
heat or expose to direct sunlight for an extended period
of time.
AVERTISSEMENT ! Ne placez pas l’unité près des
sources de chaleur ou exposition pour diriger la lumière
du soleil pendant une période prolongée.
Warning! Install in accordance with all national, state,
and local electrical codes.
AVERTISSEMENT ! Installez selon tous les national, état,
et codes électriques locaux.
Warning! This product generates heat. The room must
have adequate ventilation or the ability to dissipate heat
eectively.
AVERTISSEMENT ! Ce produit produit de la chaleur.
La salle doit avoir à ventilation proportionnée ou la
capacité d’absorber la chaleur ecacement.
Warning! This product must be grounded in accordance
with the National Electrical Code (NEC) requirements.
AVERTISSEMENT ! Ce produit doit être fondu selon les
conditions électriques nationales de code (NEC).
Warning! Use this product only in dry locations.
AVERTISSEMENT ! Employez ce produit seulement dans
des endroits secs.
Caution! Do not use pens or sharp objects to navigate
or make selections on the touchscreen. To select an item
or scroll through a list, use your fingertip.
AVERTISSEMENT ! N’employez pas les stylos ou les
objets pointus pour diriger ou pour faire des choix sur
l’écran. Pour choisir un article ou un rouleau par une
liste, employez votre bout du doigt.
Caution! Improper use or installation can cause
DAMAGE OF PROPERTY.
AVERTISSEMENT ! L’utilisation ou l’installation inexacte
peut causer DAMAGE DE PROPRIÉTÉ.
Important! Using this product in a manner other than
outlined in this document voids your warranty. Further,
Control4 is NOT liable for any damage incurred with the
misuse of this product. See “Warranty.”
Important ! Utilisant ce produit en quelque sorte autre
que décrit dans ce document vide votre garantie. De
plus, Control4 n’est pas responsable d’aucun dommage
encouru avec l’abus de ce produit. Voyez que «
Warranty. »
Specifications and requirements
Specifications
Model Numbers C4-T4IW10-BL, C4-T4IW10-WH,
C4-T4IW8-BL, C4-T4IW8-WH
Screen Resolution: 1920 × 1200, capacitive touch
Camera: 720p
Network
Ethernet or Wi-Fi
• 802.11b/g/n 2.4 GHz
• 802.11a/n/ac 5 GHz
• Security: WEP, WPA/WPA2 PSK, 802.1x EAP, PEAP
Notes: (1) While technically the touchscreen can
use 802.11b, 802.11b is not supported. (2) 802.11n
is recommended for best performance. Even
with 802.11n, broadcasting to several devices will
degrade Video Intercom response time and images.
Broadcasting to additional devices will further
degrade performance. See “Wireless Network
Limitations.”
Power supply PoE (IEEE 802.3af) 13 W peak
100-240V AC, 50/60 Hz
Dimensions (W × H × D)
8" model: 175 × 127 × 13 mm (6.9 × 5.0 × 0.53")
10" model: 239 × 165 × 13 mm (9.4 × 6.5 × 0.53")
Wall box: 68 × 104 × 61 mm (2.7 × 4.1 × 2.4")
Power box: 71 × 114 × 46 mm (2.8 × 4.5 × 1.8")
Weight (with mid-box) 8" model: 0.41 kg (0.9 lb)
10" model: 0.68 kg (1.5 lb)
Operating temperature 0 to 40 ˚C (32 to 104 ˚F)
Storage temperature -20 to 70 ˚C (-4 to 158 ˚F)
Requirements
• A controller fully installed and configured with Control4
OS3.2.0 or later.
• Control4 Touchscreen wall box installed. See “Accessories.”
• If using Ethernet with PoE power:
• Ethernet network installed and available that includes a
gateway/router/switch
• Control4 PoE Injector (model #AC-POE1-B) or another
third-party, UL/ANSI-certified PoE injector or switch.
• Two Ethernet Cat 5/6 cables: (1) one that runs from the
Ethernet gateway/router/switch to the PoE injector/switch
and (2) one that runs from the PoE injector/switch to the
Ethernet connection in the touchscreen’s wall box.
• If using Ethernet with AC power:
• Ethernet network installed and available that includes a
gateway/router/switch
• Access to in-wall AC power (neutral connection required)
• One Ethernet Cat 5/6 cable that runs from the Ethernet
gateway/router/switch to the touchscreen
• A 14-gauge electrical wire long enough to pull between
the touchscreen and the power source
• If using Wi-Fi with AC power:
• Wireless network (IEEE 802.11b/g/n) installed and
available with a wireless access point (AP). Security can
be WEP, WPA/WPA2 PSK, 801.1x EAP, or PEAP.
• Access to in-wall AC power (neutral connection required)
• A 14-gauge electrical wire long enough to pull between
the touchscreen and the power source
3
Front view
E
A B C
D
A Indicator LED (startup, camera in use, audio listening)
B Camera
C Ambient light sensor
D Stereo microphones
E 8”or 10” diagonal, capacitive 1920 × 1200 display
Back view
D
CB
G
E
F
A
A Reset pinhole buttons-For resetting and restoring the
touchscreen to factory default settings.
B Upper mount tab
C Power—Press this button to turn the touchscreen on, or press
and hold it to turn the touchscreen o.
D Docking electrical connector
E Locking tab
F Set screw—secures the touchscreen to the power box.
G Stereo speakers
Top view
A B C
A Power button. Press to turn the display on and off, press and
hold to select Power off or Restart, or press and hold for 10
seconds to reset the device.
B Center pinhole. Not used.
C Reset pinhole. Press to reset, or press and hold until “Erasing”
appears on the screen to restore factory defaults.
Touchscreen placement
Place the touchscreen in a convenient location at eye level,
typically near the entrance of the room, about 145 to 155 cm
(57to61 inches) from the floor (Figure 3).
Note: Consider the camera on the panel and the height
of the people in the home who will use the camera for
Video Intercom.
Important: The top of the touchscreen must be
mounted no higher than 2 m (6.6 ft.) above the floor.
Figure 1: Touchscreen placement
LED indicator
The LED on the touchscreen indicates the camera status of the
camera and booting information as described in the next table.
Camera/LED color state Touchscreen status
O Camera is o
Green Camera is on
Green (blinking slowly) Touchscreen is booting
Installation
Warning! Before installing the touchscreen, switch o
the circuit breaker or remove the fuse from the fuse box.
AVERTISSEMENT ! Pour l’endroit où vous installez
l’écran tactile, coupez le disjoncteur ou enlevez le fusible
de la boîte de fusible.
Important! Before you can complete the instructions
below, you must have an 8"or 10"Touchscreen wall box
installed according to the documentation provided in
the wall box kit. See “Accessories” for details.
Important ! Avant de lire les instruction ci-dessous,
il vous faut un support mural installé suivant la
documentation fournie avec le kit du support mural. Plus
de détails dans la partie << Accessoires >>.
Important! When cutting the opening for the wall box,
do not cut the opening too large. Be conservative and
cautiously enlarge it as needed.
Important ! En coupant l’ouverture pour le support
mural, ne faites pas une ouverture trop grande. Soyez
prudent, et agrandissez la avec précaution.
Touchscreen
AC power
(unless using PoE)
4
Power and network installation options
This device uses an Ethernet or Wi-Fi network connection and
can be powered using PoE or AC power.
Choose one of the following options to install the power and
network communication.
Caution! Do not attempt to use PoE and AC power at
the same time. Choose only one power option.
ATTENTION ! Ne pas tenter d’utiliser PoE et AC en
même temps. Choisir une seule option d’alimentation.
Option 1: Ethernet connection with PoE
PoE supplies DC power on the Ethernet cable using a PoE
Injector (model #AC-POE1-B) or a third-party PoE solution to
provide the touchscreen with power and a network connection.
The touchscreen works with the Control4 PoE Injector or a third-
party PoE Injector.
To set up your PoE and Ethernet connection with a PoE Injector:
1 Attach the PoE Injector according to the instructions in your
PoE’s installation guide if provided. Control4 PoE Injector
instructions are provided later in this document.
2 Pull the Ethernet cable from that location to where you want
to install the touchscreen.
Figure 2: Ethernet with PoE—Requires Ethernet connection to PoE
injector
Option 2: Ethernet connection with AC
The Ethernet is connected directly to the switch (Figure 5). This
power connection requires both neutral and hot connections.
Figure 3: Ethernet—Requires a connection to Ethernet and AC power
Option 3: Wi-Fi connection with AC
Place the touchscreen above a power source, for example, an
outlet. Ensure that you have Wi-Fi in the home (Figure 6).
Important: The touchscreen cannot connect to a Wi-Fi
network when already connected by Ethernet.
Notes: (1) Video Intercom. Although this device
supports 802.11b/g/n, 802.11 b is not recommended for
Video Intercom use. (2) We recommend Wireless-N for
Video Intercom. See the Composer Pro User Guide for
details about the touchscreen’s properties.
Wireless Network Limitations: Many Wi-Fi Access Points
handle Multicasts (Wi-Fi simultaneously sent to multiple
devices, for example, when the touchscreen broadcasts
video to all stations) by slowing down transmission
speed to the 1 Mb basic rate. This can cause overall
Wi-Fi congestion in the Wi-Fi network during the
broadcast. Video Intercom response times and images
may degrade at each device.
If a home requires a large number of Wi-Fi Video
Intercom devices, ensure that you have a robust Wi-Fi
network (possibly consisting of multiple access points).
Figure 4: Wi-Fi—Requires AC power and AP
Power installation
Prepare the plastic power box for installation into the wall box by
inserting either the Ethernet cable or the AC power cable into the
power box, and then follow the instructions.
Connecting PoE
Connect the PoE injector to power and the network, and then
connect it to the power box. It can be located anywhere along
the cable that connects the power box to the network switch.
To install a Control4 PoE injector:
1 Connect the Control4 PoE injector to an AC outlet using the
power cord.
2 Connect one of the LAN ports on the network switch to the
PoE Injector’s LAN port using Cat 5/6 Ethernet cable.
3 Pull a cable going from the PoE injector’s PWR LAN-OUT
port through one of the touchscreen’s left-side wall box
knockout holes.
4 Go to “Connecting to a wired network” below.
Place touchcreen here
Controller
Switch
Wireless
access point
WiFi
5
Connecting to a wired network
To connect to a wired network:
1 Pull the in-wall Ethernet cable through a left-side knockout
hole of the wall box, then plug it into the Ethernet jack on
the back of the power box (Figure 8).
Figure 5: Insert Ethernet cable into power box
Note: The Ethernet port on the power box does not
have functioning indicator LEDs.
2 Go to “Attach the power box and touchscreen” below.
Connecting AC power
The steps below represent a typical U.S. installation.
Caution: Use only 14 AWG wire for AC connections. For
supply connections, use wires suitable for at least
60 °C (140 °F).
1 Connect the wires to the AC power source for the
touchscreen according to national and local electrical codes.
Installation may require alternative wires and the use of the
included terminal block.
2 Pull the power cable through a right-side knockout hole of
the wall box to the terminal block.
3 Strip the black and white power wire ends to 1/4"as
necessary. Using a flat-head screwdriver, loosen the screws
on the power box’s terminal block and connect the power
wires to each terminal (Figure 5), then tighten the screws.
Figure 6: Connect AC power to terminal block
Neutral (N)
Line (L)
4 If using a plastic wall box with an exposed bare copper
ground, wrap the ground in electrical tape or heat shrink
tape/tubing. If using a metal wall box, attach the ground
wire to the wall box.
Attach the power box and touchscreen
To attach the power box and touchscreen:
1 Align and bend the wires to fit them inside the wall box.
2 Slide the power box into the wall box, then secure the
power box to the wall box using the two screws provided
(Figure6).
Caution: Do not use an electric driver to tighten the screws.
Overtightening can result in the power box becoming slightly
warped, resulting in a poor electrical docking connection.
Use only a hand screwdriver to tighten the screws.
Tip: If overtightened screws result in the power box warping,
loosen the screws until the power box is flush to the wall.
Figure 7: Secure power box to wall box
3 Angle the top of the touchscreen toward the wall, insert the
top mounting bracket onto the power box, then press the
bottom of the touchscreen into place (a magnet will hold it
in position).
Figure 8: Attach the touchscreen top first
4 Secure in place with the included set screw and 3/32" hex
wrench.
6
Configuration
Configure the touchscreen for wireless (optional)
To configure the touchscreen for wireless:
1 After initialization, tap Network. The network configuration
page opens.
2 Under Wi-Fi, tap or slide OFF/ON to enable WiFi, then tap
the Wi-Fi field to open a list of available networks.
3 Tap the network name you want to connect to.
4 Tap the Password field, then use the on-screen keyboard to
type the password (if required).
Note: If you need to enter a static IP address, follow the
instructions under “To set a wireless static IP address”
below before proceeding.
5 Tap Connect.
If you don’t see the network you want:
1 Tap +, then tap the Network SSID field and type the SSID
(name) of the network by using the on-screen keyboard.
2 Tap the Security field, then select the type of security to use.
3 Tap the Password field, then use the on-screen keyboard to
type the password (if required).
Note: If you need to enter a static IP address, follow the
instructions under “To set a wireless static IP address”
below before proceeding.
4 Tap Save. The new network is added to the bottom of the
network list.
To set a wireless static IP address:
1 Scroll down and tap Show advanced options.
2 Tap IPsettings, then tap Static.
3 Select each box one at a time and use the on-screen
keyboard to type the:
• IP address
• Gateway
• Network prefix length
• DNS 1 (preferred)
• DNS 2 (alternate)
Configure the touchscreen for Ethernet
If you want to use DHCP (default) for your Ethernet connection,
no further setup is required.
To configure a static IP address for Ethernet:
1 After initialization, tap Network. The network configuration
page opens.
2 Tap Ethernet. The Ethernet settings screen opens.
3 Tap Static IP Settings, then tap Use static IP.
4 Select each box one at a time and use the on-screen
keyboard to type the IP Address, Gateway, Netmask, DNS 1
(preferred), and DNS 2 (alternate).
5 Tap SAVE when finished.
Add and configure in Composer Pro
After the touchscreen is installed and appears on the home
network, use Composer Pro to add it to the Control4 system and
configure it.
Use the Composer Pro System Design and Connections views to
add and configure this device.
To add and configure a T4 touchscreen to a project:
1 Add the T4 8/10"In-Wall Touchscreen driver to your project.
2 Select the touchscreen or its Intercom component in the
project tree’s System Design view.
3 View and change the properties in the Properties pane as
needed.
Properties include:
• Network Connection—Reports the touchscreen’s current
network connection type.
• Back Light—Use the arrows or type numbers to set the
light level, then click Set.
• Adaptive Brightness Enabled—Enables or disables
adaptive brightness.
Advanced properties include:
• Camera Enabled—Enables or disables the camera.
• Reboot—Remotely reboots the touchscreen.
Intercom (nested under the touchscreen) properties:
• Appearance
• Exclude from Navigator—Select to hide the
touchscreen from appearing in user interfaces as an
available device.
• High Quality Enabled—Select to use the highest
resolution setting for the camera.
• Dial Pad UI Enabled—Enables the on-screen dial pad.
• Behavior
• Select the modes you want this touchscreen to
support: Play Door Chime, Do Not Disturb, Auto
Answer, Send Video, Monitor Mode, Echo Calibration,
Disable Echo Cancellation.
• Audio Control—Select the volume of individual audio
settings.
• Sip Information—Information for integrating the
touchscreen into your SIP/VoIP system.
• Custom Buttons—Select to enable and label the two
available custom buttons
• Alternate Camera—Select to use an external camera for
the video associated with the touchscreen, for example,
a security camera mounted to the side of the person
operating the touchscreen.
7
Troubleshooting
Boot up time
When the device is booting up, it may take 30 seconds or longer
before the Green LED turns on. When it turns on, it blinks slowly
for a time and then turns o. After that, you’ll see an image on
the touchscreen (either the setup menu or the room’s home
screen).
Unresponsive screen
If the camera’s LED blinks on and o for more than 30 seconds,
the device may need to be power cycled. If power cycling doesn’t
solve the problem, the touchscreen may need to be restored to
factory defaults.
To power cycle the touchscreen:
1 Press and hold the power button for several seconds until
the touchscreen turns o.
2 Press and release the power button again to turn back on.
To restore to factory defaults:
1 On the touchscreen’s main screen, tap Settings, System Info,
then Factory data reset.
- OR -
If the touchscreen has not yet been configured, tap About,
then Factory data reset.
- OR -
To reset without using the display screen, insert a
straightened paper clip into the left pinhole on top of the
touchscreen, then press and hold it while pressing the RESET
(right) pinhole button for several seconds until the the icon
below appears on the display.
Removing the touchscreen from the wall
To remove the touchscreen:
1 Remove the 3/32" set screw.
2 Pull the bottom of the touchscreen away from the locking
tab, then lift the screen up and o the power box.
Figure 9: Lift bottom away and lift up
control4.com | 888.400.4070
Additional resources
The following resources are available for additional support.
• Knowledgebase and forums in Technician Community
• Technical Support
• Control4 website:
www.control4.com
• Composer documentation in its online help.
Warranty and legal notices
Find details of this product’s 2-Year Limited Warranty at
snapav.com/warranty
, or request a paper copy from Customer
Service at (866) 424-4489. Find other legal resources, such as
regulatory notices and patent information, at
snapav.com/legal
.
More help
For the latest version of this document, open this URL or scan the
QR code on a device that can view PDFs.
200-00678-B
2020-10-20 MS
Copyright ©2020, Wirepath Home Systems, LLC. All rights reserved. Control4 and Snap AV and their respective logos are registered trademarks or trademarks of
Wirepath Home Systems, LLC, dba “Control4” and/or dba “SnapAV” in the United States and/or other countries. Snap AV and Wirepath are also registered trademarks
or trademarks of Wirepath Home Systems, LLC. Other names and brands may be claimed as the property of their respective owners. All specifications subject to change
without notice. B
LATEST VERSION OF THIS DOCUMENT
ctrl4.co/t4-inwall-ig
WALL BOX INSTALL: NEW CONSTRUCTION
ctrl4.co/wallbox-new
WALL BOX INSTALL: RETROFIT
ctrl4.co/wallbox-retro
In-Wall Touchscreen
Wall Box - New Construction
Installation Guide
Introduction
This wall box kit provides a wall box (back box) to accommodate the installation
of in-wall touchscreens. The kit is intended for new construction where drywall
is not yet in place. Along with the wall box, the kit contains a stud plate for
attachment to a wall stud before drywall installation.
Supported touchscreen models
• C4-T4IW8-BL 8" T4 In-Wall Touchscreen, Black
• C4-T4IW8-WH 8" T4 In-Wall Touchscreen, White
• C4-T4IW10-BL 10" T4 In-Wall Touchscreen, Black
• C4-T4IW10-WH 10" T4 In-Wall Touchscreen, White
Also supports these legacy touchscreens:
• C4-WALL7 T3-7 7" In-Wall Touchscreen
• C4-WALL10 T3-10 10" In-Wall Touchscreen
• C4-TSWMC5-EG 5" In-Wall Touchscreen
• C4-TSWMC7-EG 7" In-Wall Touchscreen
• C4-TW7C0 7" In-Wall Touchscreen with Camera
• For more installation instructions specific to legacy touchscreens, see earlier
versions of this guide.
Box contents
The following items are included in the kit:
• In-Wall Touchscreen Wall Box - New Construction
• Ferrite clamps: two rectangular, one round
• Plastic wall boxes include two screws. Metal wall boxes include four screws
(2 short, 2 long)
Tools needed
• Tape measure and pencil
• Hammer or screwdriver
• A 5/16" nut driver or socket wrench (metal wall box only)
• Nails or screws (4 to 6)
Warning! Before you install the wall box, ensure that you’ve turned o the
power to the wires that will be attached to the box.
Attention ! Avant d’installer le boîtier arrière, assurer vous d’avoir désactivé le
pouvoir sur les fils qui seront attachées à la boîte.
Specifications
Dimensions: 68 x 104 x 81 mm (2.7 x 4.1 x 3.19")
Plastic wall box model (C4-NWB57C-P)
A Dovetail socket (on both sides to reverse position)
B Stud plate
B
A
Metal wall box model (C4-NWB57C-M)
A Mounting location (on both sides to reverse position)
B Stud plate
B
A
Installing the wall box
Note: This kit is intended for installation of a wall box before drywall
installation. If the drywall is in place, use kits intended for retrofit (C4-
RWB57C-P or C4-RWB57C-M). For more information, visit the product pages
at
ctrl4.co/boxnewp
and
ctrl4.co/boxnewm
.
To install this wall box:
1 Find an appropriate wall box location for the touchscreen you are installing:
• The wall box should be in a convenient location, for example, near the
entrance of a room.
• The wall box should be at eye level, about about 1.5meters (57 to
61inches) from the floor.
Touchscreen
AC outlet (unless
using PoE)
• When using Ethernet or PoE, the wall box should be near a location where
an Ethernet Cat 5/6 cable is pulled.
• When using AC power, position the wall box above or near an AC power
source, such as an AC outlet.
2 Hold the wall box and stud plate against the nearest stud, then mark the
correct position according to your choices in Step 1. Follow these guidelines:
a Place the wall box so that, when mounted, it is flush with the surface of
the drywall after the drywall is installed. For example, if the drywall is
3/8 of an inch deep, the front rim of the wall box must be 3/8 of an inch
above the wall stud (toward you).
Important: Make sure the wall box is flush with the wall after the drywall
is installed. Allow 3/8 of an inch before the drywall is installed (depending
on the thickness of the drywall), and err toward 5/16 inch for the best fit.
b Install the wall box according to the arrows inside the box that indicate
the correct side up.
Important: For safety, install the wall box with the correct side up.
c Install the wall box with the stud plate on either the right or the left side,
depending on which wall stud you choose. You may detach the stud plate
from the wall box on one side and reattach it on the opposite side, if
needed.
3 Detach the stud plate from the wall box.
• Plastic box: Slide the wall plate toward the back of the wall box.
• Metal box: Unscrew the wall box from the stud plate.
This allows you to attach the stud plate to the wall stud without interference
from the wall box.
4 Align the stud plate with the marks you made on the stud (Step 2). If you are
using a plastic wall box, make sure the dovetail is toward the back of the stud
plate (away from you).
5 Nail or screw the stud plate to the wall stud.
Recommended hardware: #9/3.5 mm wood screw or 6D/3 mm nail.
6 Mount the wall box to the stud plate.
• Plastic box: Slide the wall box onto the stud plate dovetail all the way,
leaving the wall box protruding the depth of the drywall, or slightly less
(Step 2a).
• Metal box: Bolt the wall box back onto the stud plate.
Note: If you are using a metal box, you can continue to adjust its angle
and position slightly relative to the drywall.
7 When running cables into the wall box, use a left-side knockout for the
Ethernet cable, and use a right-side knockout for the AC power (if used).
Note: The left (low-voltage) and right (high-voltage) sides of the wall box are
separated by a barrier. Low-voltage connections must be pulled through a
knockout on the left side, and high-voltage on the right.
Caution: Use only 14 AWG wire for AC connections. For supply connections,
use wires suitable for at least 60 °C (140 °F).
8 Install the drywall as you would normally, making sure to cut the size of the
hole accurately.
9 After you install the drywall, carefully tighten the screws to pull in the
securing tabs so that the wall box is flush with the surface of the wall.
Important: In the metal wall box kit, the two longer screws are for use
with the T4, the shorter for use with the T3.
Note: Overtightening the screws may pull the box into the wall.
Important: When you are ready to install the drywall, and you are cutting the
opening for the wall box, do not cut the opening too large. Be conservative
and enlarge the hole as needed.
Additional resources
The following resources are available for additional support.
• Knowledgebase and forums in Technician Community
• Technical Support
• Control4 website:
www.control4.com
• Composer documentation in its online help.
Warranty and legal notices
Find details of this product’s 2-Year Limited Warranty at
snapav.com/warranty
, or
request a paper copy from Customer Service at (866) 424-4489. Find other legal
resources, such as regulatory notices and patent information, at
snapav.com/legal
.
More help
For the latest version of this document, open this URL or scan the QR code on a
device that can view PDFs.
200-00165-J
2020-10-20 MS
J
Copyright ©2020, Wirepath Home Systems, LLC. All rights reserved. Control4 and Snap
AV and their respective logos are registered trademarks or trademarks of Wirepath
Home Systems, LLC, dba “Control4” and/or dba “SnapAV” in the United States and/or
other countries. Snap AV and Wirepath are also registered trademarks or trademarks of
Wirepath Home Systems, LLC. Other names and brands may be claimed as the property
of their respective owners. All specifications subject to change without notice.
MOST RECENT VERSION
ctrl4.co/wallbox-new
T4 IN-WALL TOUCHSCREEN INSTALL GUIDE
ctrl4.co/t4-inwall-ig
Regulatory Compliance & Safety Information for Model C4-T4IW8-WH, C4-T4IW8-BL, C4-
T4IW10-WH, C4-T4IW10-BL
Electrical Safety Advisory
Sécurité électrique consultatif
Important Safety Instructions
Consignes de sécurité importantes
Read the safety instructions before using this product.
Lisez les consignes de sécurité avant d'utiliser ce produit.
1. Read these instructions.
Lisez ces instructions.
2. Keep these instructions.
Conservez ces instructions.
3. Heed all warnings.
Respectez tous les avertissements.
4. Follow all instructions.
Suivez toutes les instructions.
5. Do not use this apparatus near water.
Ne pas utiliser cet appareil près de l'eau.
6. Clean only with dry cloth.
Nettoyez-le uniquement avec un chiffon sec.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s
instructions.
Ne pas bloquer les ouvertures de ventilation. Installer conformément aux instructions du
fabricant.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other
apparatus (including amplifiers) that produce heat.
Ne pas installer près de sources de chaleur telles que des radiateurs, registres de
chaleur, poêles, ou autres appareils (incluant les amplificateurs) qui produisent de la
chaleur.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized
plug has two blades with one wider than the other. A grounding type plug has two blades
and a third grounding prong. The wide blade or the third prong is provided for your safety.
If the provided plug does not fit into your outlet, consult an electrician for replacement of
the obsolete outlet.
Ne pas contourner le dispositif de sécurité de la fiche polarisée ou de mise à la terre. Une
fiche polarisée possède deux lames dont une plus large que l'autre. Une fiche de terre a
deux lames et une troisième broche de terre. La lame large ou la troisième broche est
fournie pour votre sécurité. Si la fiche fournie ne s'adapte pas à votre prise, consultez un
électricien pour le remplacement de la prise obsolète.
10. Only use attachments/accessories specified by the manufacturer.
Utilisez uniquement des fixations / accessoires spécifiés par le fabricant.
11. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or
sold with the apparatus. When a cart is used, use caution when moving the
cart/apparatus combination to avoid injury from tip-over.
Utilisez uniquement avec le chariot, le socle, le trépied, le support ou la table spécifiés
par le fabricant ou vendu avec l'appareil. Lorsque vous utilisez un chariot, soyez prudent
lorsque vous déplacez l'ensemble chariot / appareil pour éviter des blessures dues au
renversement.
12. Unplug this apparatus during lightning storms or when unused for long periods of time.
Débranchez cet appareil pendant les orages ou lorsqu'il n'est pas utilisé pendant de
longues périodes de temps.
13. Warning! Install this equipment in accordance with all national, state, and local electrical
codes and must be completed by a certified electrician. For supply connections use 14
AWG only that is suitable for at least 600C. This equipment must be mounted at height
less than or equal to 2m. This equipment may only be used with, and requires the use of,
one of the following separately certified Wall-Box models, C4-NWB57C-M, C4-NWB57C-
P, C4-RWB57C-M, C4-RWB57C-P.
Attention! Installez cet équipement conformément à tous les codes électriques nationaux,
provinciaux et locaux et doit être effectué par un électricien certifié. Pour les connexions
d'alimentation, utilisez uniquement 14 AWG qui convient à au moins 600C. Cet
équipement doit être monté à une hauteur inférieure ou égale à 2 m. Cet équipement ne
peut être utilisé qu'avec l'un des modèles de boîtiers muraux certifiés séparément
suivants, C4-NWB57C-M, C4-NWB57C-P, C4-RWB57C-M, C4-RWB57C-P.
14. Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus
has been exposed to rain or moisture, does not operate normally, or has been dropped.
Confiez toutes les réparations à un personnel qualifié. Une réparation est nécessaire
lorsque l'appareil a été endommagé de quelque façon que ce soit le cordon
d'alimentation ou la fiche est endommagé, du liquide a été renversé ou si des objets sont
tombés dans l'appareil, l'appareil a été exposé à la pluie ou à l'humidité, ne fonctionne
pas normalement, ou s'il est tombé.
15. This equipment uses AC power which can be subjected to electrical surges, typically
lightning transients which are very destructive to customer terminal equipment connected
to AC power sources. The warranty for this equipment does not cover damage caused
by electrical surge or lightning transients. To reduce the risk of this equipment becoming
damaged it is suggested that the customer consider installing a surge arrestor.
Cet équipement utilise la puissance AC qui peuvent être soumis à des surtensions
électriques, la foudre généralement transitoires qui sont très destructives envers les
équipements terminaux connectés à des sources d'alimentation CA. La garantie de cet
appareil ne couvre pas les dommages causés par les surtensions électriques ou
transitoires de foudre. Pour réduire le risque de cet équipement devient endommagé, il
est suggéré que le client envisager l'installation d'un limiteur de surtension.
16. To completely disconnect unit power from the AC mains, turn off the circuit breaker. To
reconnect power, turn on the circuit breaker following all safety instructions and
guidelines. The circuit breaker shall remain readily accessible.
Pour déconnecter complètement l'alimentation de l'unité du secteur, désactivez le
disjoncteur. Pour rebrancher l'alimentation, activez le disjoncteur en suivant toutes les
instructions et directives de sécurité. Le disjoncteur doit rester facilement accessible.
17. This product relies on the buildings installation for short-circuit (overcurrent) protection.
Ensure that the protective device is rated not greater than: 20A.
Ce produit repose sur l'installation des bâtiments pour les courts-circuits (surintensité) de
protection. Assurez-vous que le dispositif de protection est assignée ne dépassant pas:
20A.
18. Never push objects of any kind into this product through cabinet slots as they may touch
dangerous voltage points or short out parts that could result in fire or electric shock.
N'introduisez jamais d'objets d'aucune sorte dans ce produit à travers les fentes du
boîtier car ils pourraient toucher des points de tension dangereux ou court-circuiter des
pièces qui pourraient entraîner un incendie ou un choc électrique.
19. This product can interfere with electrical equipment such as tape recorders, TV sets,
radios, computers and microwave ovens if placed in close proximity.
Ce produit peut interférer avec des appareils électriques tels que les magnétophones,
téléviseurs, radios, ordinateurs et fours à micro-ondes si placés à proximité.
The lightning flash and arrow head within the triangle is a warning sign alerting
you of dangerous voltage inside the product
L'éclair et la flèche dans le triangle est un signe d'alerte pour vous avertir
d'une tension dangereuse à l'intérieur du produit
Caution: To reduce the risk of electric shock, do not remove cover (or back).
No user serviceable parts inside. Refer servicing to qualified service
personnel.
Attention: Pour réduire le risque de choc électrique, ne pas retirer le couvercle
(ou l'arrière). Aucune pièce réparable par l'utilisateur. Confiez l'entretien à un
personnel qualifié.
The exclamation point within the triangle is a warning sign alerting you of
important instructions accompanying the product.
Le point d'exclamation dans un triangle est un signe d'avertissement vous
signale des instructions importantes accompagnant le produit.
See marking on bottom / back of product
Voir le marquage sur les bas / dos du produit
Warning!: To reduce the risk of electrical shock, do not expose this
apparatus to rain or moisture
AVERTISSEMENT! Pour réduire le risque de choc électrique,
n'exposez pas cet appareil à la pluie ou à l'humidité.
Save these instructions
Conservez ces instructions
Compliance of this equipment is confirmed by the following label that is placed on the equipment:
Conformité de cet appareil est confirmé par le symbole suivant qui est placé sur l'équipement:
USA & Canada Compliance
FCC Part 15, Subpart B & IC Unintentional Emissions Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
•Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC rules and ISED’s license-exempt RSSs. Operation
is subject to the following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Cet appareil est conforme à la section 15 des règles de la FCC et ISED’s aux RSS exempts de
licence d'ISED. Son utilisation est soumise aux deux conditions suivantes: (1) Cet appareil ne
doit pas causer d’interférences nuisibles et (2) cet appareil doit accepter toutes les interférences
reçues, y compris celles pouvant entraîner un fonctionnement non souhaité.
IMPORTANT! Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.
IMPORTANT! Tous les changements ou modifications pas expressément approuvés par la partie
responsable de la conformité ont pu vider l’autorité de l’utilisateur pour actionner cet équipement.
Canada Warning Statement:
CAN ICES-3 (B)/NMB-3(B)
• This product meets the applicable Innovation, Science and Economic Development Canada
technical specifications.
• Ce produit répond aux spécifications techniques applicables à l'innovation, Science et
Développement économique Canada.
FCC Part 15, Subpart C / RSS-247 Intentional Emissions Interference Statement
Compliance of this equipment is confirmed by the following certification numbers that are placed
on the equipment:
Notice: The term “FCC ID:” and “IC:” before the certification number signifies that FCC and
Industry Canada technical specifications were met.
FCC ID: 2AJACT4TS
IC: 7848A-T4TS
This equipment must be installed by qualified professionals or contractors in accordance with
FCC Part 15.203 & IC RSS-247, Antenna Requirements. Do not use any antenna other than the
one provided with the unit.
Operations in the 5.15-5.25GHz band are restricted to indoor usage only.
Caution :
(i) the device for operation in the band 5150-5250 MHz is only for indoor use to reduce the
potential for harmful interference to co-channel mobile satellite systems;
(ii) the maximum antenna gain permitted for devices in the band 5725-5850 MHz shall be such
that the equipment still complies with the e.i.r.p. limits specified for point-to-point and
non-point-to-point operation as appropriate; and
(iii) Users should also be advised that high-power radars are allocated as primary users (i.e.
priority users) of the bands 5650-5850 MHz and that these radars could cause interference
and/or damage to LE-LAN devices.
Avertissement:
(i) les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une
utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de
satellites mobiles utilisant les mêmes canaux;
(ii) le gain maximal d'antenne permis (pour les dispositifs utilisant la bande de 5725 à
5 850 MHz) doit être conforme à la limite de la p.i.r.e. spécifiée pour l'exploitation
point à point et l’exploitation non point à point, selon le cas;
(iii) De plus, les utilisateurs devraient aussi être avisés que les utilisateurs de radars de haute
puissance sont désignés utilisateurs principaux (c.-à-d., qu’ils ont la priorité) pour les bandes
5650-5850 MHz et que ces radars pourraient causer du brouillage et/ou des dommages aux
dispositifs LAN-EL.
FCC Partie 15, sous-partie C / RSS-247 Déclaration volontaire des émissions interférences
Conformité de cet appareil est confirmé par les chiffres de certification suivants qui sont placés
sur l'équipement:
Avis: Le terme «FCC ID:" et "IC:" devant le numéro de certification signifie que les spécifications
techniques de la FCC et d'Industrie Canada ont été respectées.
FCC ID: 2AJACT4TS
IC: 7848A-T4TS

Other manuals for T4 Series

3

This manual suits for next models

4

Other Contro l4 Touchscreen manuals

Contro l4 C4-TW7C0-BL User manual

Contro l4

Contro l4 C4-TW7C0-BL User manual

Contro l4 T3 Series User manual

Contro l4

Contro l4 T3 Series User manual

Contro l4 C4-FP C Series User manual

Contro l4

Contro l4 C4-FP C Series User manual

Contro l4 T4 Series User manual

Contro l4

Contro l4 T4 Series User manual

Contro l4 T4 Series User manual

Contro l4

Contro l4 T4 Series User manual

Contro l4 C4-TSMC7-EN-BL User manual

Contro l4

Contro l4 C4-TSMC7-EN-BL User manual

Contro l4 T3 Series User manual

Contro l4

Contro l4 T3 Series User manual

Contro l4 T4 Series User manual

Contro l4

Contro l4 T4 Series User manual

Popular Touchscreen manuals by other brands

Acuity Fresco Quick start manual

Acuity

Acuity Fresco Quick start manual

Speechi SpeechiTouch 003 quick start guide

Speechi

Speechi SpeechiTouch 003 quick start guide

Videx 6700 Series manual

Videx

Videx 6700 Series manual

Advantech UTC-520A user manual

Advantech

Advantech UTC-520A user manual

DTEN D7 Product guide

DTEN

DTEN D7 Product guide

Elo TouchSystems 1900L Specification sheet

Elo TouchSystems

Elo TouchSystems 1900L Specification sheet

Fireye Plant Master Guide

Fireye

Fireye Plant Master Guide

Disgo Tablet 6000 user manual

Disgo

Disgo Tablet 6000 user manual

FDI uEZ GUI Series quick start guide

FDI

FDI uEZ GUI Series quick start guide

Dell C8618QT user guide

Dell

Dell C8618QT user guide

Element VK Series user manual

Element

Element VK Series user manual

Elo TouchSystems 2639L Product dimensions

Elo TouchSystems

Elo TouchSystems 2639L Product dimensions

GE 60-924-RF-TS Simon XT Installation sheet

GE

GE 60-924-RF-TS Simon XT Installation sheet

Advantech UPOS-M15 Series Startup manual

Advantech

Advantech UPOS-M15 Series Startup manual

Johnson Controls Tyco HS2TCHP E user manual

Johnson Controls

Johnson Controls Tyco HS2TCHP E user manual

CAME STDCSN manual

CAME

CAME STDCSN manual

HDI Mobi OS Series Operation manual

HDI

HDI Mobi OS Series Operation manual

DUOTECNO DT0C-10X quick start guide

DUOTECNO

DUOTECNO DT0C-10X quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.