manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Cooper Lighting
  6. •
  7. Touchscreen
  8. •
  9. Cooper Lighting TSE100 User manual

Cooper Lighting TSE100 User manual

Popular Touchscreen manuals by other brands

HAI OmniTouch 10p user manual

HAI

HAI OmniTouch 10p user manual

NEXIO HID Touch-screen user guide

NEXIO

NEXIO HID Touch-screen user guide

Elo TouchSystems E534869 user manual

Elo TouchSystems

Elo TouchSystems E534869 user manual

Dell C8618QT user guide

Dell

Dell C8618QT user guide

InTouch INDT156 user manual

InTouch

InTouch INDT156 user manual

Tipro FREE+ 12.1" Getting started

Tipro

Tipro FREE+ 12.1" Getting started

Advantech IDP31-215W Series user manual

Advantech

Advantech IDP31-215W Series user manual

Element VK Series user manual

Element

Element VK Series user manual

Johnson Controls Advanced Graphic Touchscreen Display Installation and operation manual

Johnson Controls

Johnson Controls Advanced Graphic Touchscreen Display Installation and operation manual

Elo TouchSystems 2799L user manual

Elo TouchSystems

Elo TouchSystems 2799L user manual

Elo TouchSystems 2020L Product dimensions

Elo TouchSystems

Elo TouchSystems 2020L Product dimensions

Wiggly-Amps Engage installation instructions

Wiggly-Amps

Wiggly-Amps Engage installation instructions

gefran G-Vision 67-070 Operating instructions manual

gefran

gefran G-Vision 67-070 Operating instructions manual

Sinocan T06-15 user manual

Sinocan

Sinocan T06-15 user manual

COMFILE CUTOUCH CT1820 user manual

COMFILE

COMFILE CUTOUCH CT1820 user manual

Future Design ELI101-IPHW user manual

Future Design

Future Design ELI101-IPHW user manual

InTouch KIO-LITE-215L-WM user manual

InTouch

InTouch KIO-LITE-215L-WM user manual

Elo TouchSystems 1739L user guide

Elo TouchSystems

Elo TouchSystems 1739L user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

TSE55-B Color Touchscreen
Installation Instructions
Installation guide
TSE100 Colour Touchscreen
Planning the Installation
TSE100 is designed to be wall mounted in
landscape orientation.
TSE100 requires a minimum mounting depth of
1.86” (47mm) from the front wall surface plus
room for cable/s. TSE100 is designed to be
powered over an Ethernet connection (PoE), via
iCANnetTM or an auxiliary power supply.
There are two ways the TSE100 communicates
with an iCANnetTM network.
1. A hard wired Ethernet connection to a TSI-1 /
TSI-1-NA via a PoE Switch.
Or
2. Directly to iCANnetTM using iCANnetTM cable.
Overview
Back BoxTSE100 Mounting Bracket
Installation
A dedicated mounting bracket is included with the
TSE100. Also available is an optional back box -
12NC 912600000669
(Dimensions: 134mm h x 195mm w x 48mm d.
5.28” h x 7.68” w x 1.89” d)
The mounting bracket must be used for the
installation.
Using the included screws, (or any other flat head
M3.5 screws) fix the mounting bracket to the
back box and verify that the components are level
before mounting the screen.
To allow the screen to be mounted to the bracket,
ensure there is 40mm clearance above and to the
right of the backbox.
Mounting height
The recommend mounting height for the
TSE100 is 57 - 64in (145-165cm) above the
finished floor to the center of the unit.
Mounting the TSE100
Align the mounting frame lugs with the TSE100
mounting key slots. Once located, slide the screen
first downwards and then diagonally down and to
the left. Make sure the mounting lugs are properly
engaged.
57” / 145cm
64” / 165cm
Rear of touchscreen
Mounting frame
Mounting frame lugs
Mounting frame lugs
Removing the TSE100
Grip the touchscreen firmly and first lift diagonally
up and to the right, then directly upwards to
disengage the mounting bracket lugs from the
touchscreen slots.
Connecting to the lighting system
Via Ethernet
TSE100 can connect to the lighting system using a
touchscreen interface (TSI-1 or TSI-1NA) via a PoE
network switch.
Connect the TSE100 using a standard CAT5E or
CAT6 Ethernet cable from the PoE network switch
to the LAN/PoE socket on the back of the TSE100.
Ensure that both the touchscreen and touchscreen
interface are on the same physical Ethernet
Network and within the same IP address range.
See the ‘TSE40/TSE100 Programming Guide’ for
information on setting IP addresses.
Source
Controller Control Plate /
Wallstation
iCAN
PoE Ethernet
Switch
PoE
TSI-1 /
TSI1-NA TSE
Touchscreen
PoE Ethernet Connection
Source
Controller Control Plate /
Wallstation
Control Plate /
Wallstation
iCAN
TSE
Touchscreen
Function iCANnetTM Cable Colours
+VDC Red
0V Black
CAN H White
Shield Silver
CAN L Blue
iCANnetTM Network Connections
Direct to iCANnetTM using network power
Sufficient DC power must be available on
the iCANnetTM network to accommodate the
touchscreen.
iCANnet
Maximum segment distance: 500m (1640 ft)
Devices per segment: 100 (without bridge or repeater).
Specications
Dimensions: 245.4mm w (9.66”) x 164mm h (6.45”)
Mounting depth: 47mm (1.86”)
Display: 10.05” (255.27mm) Diagonal
Resolution: 1280 x 800 (16:10)
Network: 10/100/1000 Ethernet
Supply:
• Power over Ethernet (PoE)
• 15V DC (12-18V) via iCANnetTM
• 12-24V DC via auxiliary power supply
Current Consumption:
12V DC - 660mA Max
24V DC - 330mA Max
Document: TSE100 9850-001095-02
UK
Usk House, Lakeside, Llantarnam Park,
Cwmbran, NP44 3HD, UK
Phone: +44 (0)844 324 9100
Email: [email protected]
www.ilight.co.uk
US
1121 Highway 74 South
Peachtree City, GA 30269
Phone: +1 800 553 3879
Email: [email protected]
www.cooperlighting.com
Canada
5925 McLaughlin Road
Mississauga, Ontario L5R 1B8
P: 905-501-3000
Email: [email protected]
www.cooperlighting.com
EU Authorised Representative
Cooper Lighting Netherlands B.V.
High Tech Campus
HTC 48, Eindhoven
5656 AE
Termination
iCANnetTM is a ‘daisy chain’ protocol that requires
termination on the device located at either end of
the chain.
If the TSE100 is the last device on the network a
120ohm termination resistor will need to be added
between CAN-H and CAN-L (White & Blue). These
are included in the SW3 Kit.
Auxillary Power
Link
+V cables are ommitted from the screen but need to
be connected thru for the rest of the network to work
iCANnet
Source
Controller Control Plate /
Wallstation
Control Plate /
Wallstation
PSU
iCAN
TSE
Touchscreen
Function iCANnetTM Cable Colours
+VDC Red (Not connected)
0V Black
CAN H White
Shield Silver
CAN L Blue
Never apply more than 18V DC to iCANnetTM
iCANnetTM Network Connections
Direct to iCANnetTM using auxillary power supply
TSE100 can also be connected directly to the
iCANnetTM network using iCANnetTM cable and an
auxillary power supply.
Note: When utilising a suitable DC power supply,
such as 12NC: 912600000668, be sure to fit
the green power connector included with the
touchscreen, paying particular attention to polarity.