Quick Reference 930818G © 2017, CyberData Corporation, ALL RIGHTS RESERVED© 2017, CyberData Corporation, ALL RIGHTS RESERVED 930818G Quick Reference
Mounting Options
Contacting CyberData
Fold Down all Flagnuts (4 Places)
before Inserting into Wall Cutout
Cutout
Network Cable
are Not Provided
Screws
Faceplate
Custom
Torx Drive)
Assembly
Ground Wire &
Point Upward.
Arrow Labels must
This will Ensure that
the Intrusion Sensor
Functions Properly.
Wall
Inside Custom Enclosure
Create Service Loop
Torx Key
(Phillip Drive)
(Security
Mounting
Screws
Mounting
Flagnuts
(4 Places)
4
5
Enclosure
K.O.
to J1
6.03 inches
[153mm]
5.28 inches
[134mm]
Network Cable
J1
Intrusion
Sensor
2
3
6
7
8
9
9
1
To mount the Intercom:
1. Make a wall cutout as shown in the picture.
2. Use a flat blade screwdriver to remove the knockout (KO) of the gang box.
3. Feed the ground wire (shown in the “Ground Connection” section) and the network cable from the wall cutout through the
knockout hole of the gang box.
4. Create a service loop for both the ground wire and network cable.
5. Plug the network cable into the J1 connector.
6. Make sure that the arrow labels on the sides of the gang box are pointing up. This will ensure that the intrusion sensor
functions properly.
7. Fold down all of the flagnuts, and then insert the gang box into the wall cutout.
8. Tighten the flagnuts with a size #2 Phillips screwdriver.
9. Use a size #2 Phillips screwdriver to secure the Intercom faceplate assembly to the gang box with either Phillips drive
screws or security Torx drive screws.
Sales: (831) 373-2601 ext. 334
Support: 831-373-2601 ext. 333
Support Website: http://support.cyberdata.net/
RMA Department: (831) 373-2601 ext. 136
RMA Email: [email protected]
RMA Status: http://support.cyberdata.net/
Warranty Information: http://support.cyberdata.net/
Corporate Headquarters
CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA
Phone: 831-373-2601
Fax: 831-373-4193
http://www.cyberdata.net/
Typical System Installation
Getting Started
• Download the Operations Guide PDF file, from the Downloads tab at the following webpage:
http://www.cyberdata.net/voip/011123/
• Create a plan for the locations of your Intercoms.
• WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.
• WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation
instructions.
• WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
• WARNING: This enclosure is not rated for any AC voltages!
Intercom Parts
Tool required for assembly: A size #2 Phillips screwdriver
Parameter Factory Default Setting
IP Addressing DHCP
IP Addressa10.10.10.10
Web Access Username admin
Web Access Password admin
Subnet Maska255.0.0.0
Default Gatewaya10.0.0.1
a. Default if there is not a DHCP server present.
802.3af Compliant Ethernet Switch
Intercom IP Phone IP PBX ServerIntercom Intercom
*More installation and mounting
options are available in the
Operations Guide.
(4) #6 X 3/8-inch,100 Deg.,
Flat Head, Self-Tapping Screw
(1) Intercom Assembly (1) Mounting Kit
(4) #6 X 3/8-inch,100 Deg.,
Flat Head T15 Security Pin Torx
Screw
(1) T15 Security Pin Torx Key
(1) Optional Mounting Kit
The IP Endpoint Company
Installation Quick Reference
SIP Indoor Intercom with Keypad,
Flush Mount
SIP Compliant
011123
© 2017, CyberData Corporation, ALL RIGHTS RESERVED 930818G Quick Reference Quick Reference 930818G © 2017, CyberData Corporation, ALL RIGHTS RESERVED
RTFM Button
Ground Connection
When the device is operational and linked to a network,
you can use the Reset Test Function Management
(RTFM) button (SW1 [see picture]) to announce the
device’s IP address or restore the device to the factory
default settings.
To announce the device’s current IP address:
• Press and release the RTFM button within a five
second window.
Note The device will use DHCP to obtain the new IP
address (DHCP-assigned address or default to
10.10.10.10 if a DHCP server is not present).
To restore the device to factory default settings:
• Press and hold the RTFM button for longer than five
seconds until you hear the device announce that it is
restoring the factory default settings.
RTFM button (SW1)
Star Washer
#6 Ring Terminal
Nut
inside Gang Box
Create Service Loop
Knock Out (Not Provided)
Ground Wire
Dimensions
Terminal Block Connections
6.840 [173.7]
Dimensions are in Inches [Millimeter]
5.860 [148.8]
0.170 [4.3]
2.579 [65.5]
0.25"
Terminal Block
Wire (IN)
can accept 16 AWG wire
1
8
Alternate Power Input:
1 = +8 to +12VDC @ 1000mA Regulated Power Supply*
2 = Power Ground*
Relay Contact:
(1 A at 30 VDC for continuous loads)
3 = Relay Common
4 = Relay Normally Open Contact
5 = Sense Input
6 = Sense Ground
7 = Remote Switch "A"
8 = Remote Switch "B"
*Contacts 1 and 2 on the terminal block are only for
powering the device from a non-PoE 12VDC power
source as an alternative to Network PoE power. Use of
these contacts for any other purpose will damage the
device and void the product warranty.
34
Use a 3.17 mm (1/8-inch) flat blade
screwdriver for the terminal block screws

Other manuals for #011123

4

Other CyberData Intercom System manuals

CyberData 11310 Manual

CyberData

CyberData 11310 Manual

CyberData 11214 Manual

CyberData

CyberData 11214 Manual

CyberData 11214 User manual

CyberData

CyberData 11214 User manual

CyberData 3COM VCX PBX Server User manual

CyberData

CyberData 3COM VCX PBX Server User manual

CyberData 11035 User manual

CyberData

CyberData 11035 User manual

CyberData 011309 Manual

CyberData

CyberData 011309 Manual

CyberData 11308 User manual

CyberData

CyberData 11308 User manual

CyberData 11111 User manual

CyberData

CyberData 11111 User manual

CyberData 11035 User manual

CyberData

CyberData 11035 User manual

CyberData 11111 User manual

CyberData

CyberData 11111 User manual

CyberData 011211x User manual

CyberData

CyberData 011211x User manual

CyberData 11113 User manual

CyberData

CyberData 11113 User manual

CyberData 11214 User manual

CyberData

CyberData 11214 User manual

CyberData 11209 Manual

CyberData

CyberData 11209 Manual

CyberData VoIP Intercom 010935F User manual

CyberData

CyberData VoIP Intercom 010935F User manual

CyberData 11111 User manual

CyberData

CyberData 11111 User manual

CyberData 11214 Manual

CyberData

CyberData 11214 Manual

CyberData VoIP Indoor Intercom 011030 User manual

CyberData

CyberData VoIP Indoor Intercom 011030 User manual

CyberData V3 Keypad User manual

CyberData

CyberData V3 Keypad User manual

CyberData 011478 Manual

CyberData

CyberData 011478 Manual

CyberData 011214 Manual

CyberData

CyberData 011214 Manual

CyberData RAL 9003 User manual

CyberData

CyberData RAL 9003 User manual

CyberData 11113 User manual

CyberData

CyberData 11113 User manual

CyberData 011123x User manual

CyberData

CyberData 011123x User manual

Popular Intercom System manuals by other brands

Algo 3006 installation guide

Algo

Algo 3006 installation guide

Auta 760595 manual

Auta

Auta 760595 manual

KOCOM KC-MC35 user manual

KOCOM

KOCOM KC-MC35 user manual

Aiphone JP Series installation guide

Aiphone

Aiphone JP Series installation guide

SSS Siedle Siedle Steel STLM 645-02 Product information

SSS Siedle

SSS Siedle Siedle Steel STLM 645-02 Product information

Bticino 364235 installation manual

Bticino

Bticino 364235 installation manual

Eyevision EV-IP-KP22 user manual

Eyevision

Eyevision EV-IP-KP22 user manual

3M HEADSET C1060 Replacement parts list

3M

3M HEADSET C1060 Replacement parts list

Aiphone TA-12H instructions

Aiphone

Aiphone TA-12H instructions

Vimar ELVOX 6570 Installer's guide

Vimar

Vimar ELVOX 6570 Installer's guide

Commax CDV-50P manual

Commax

Commax CDV-50P manual

Aiphone GT-1M3 Operation guide

Aiphone

Aiphone GT-1M3 Operation guide

Fermax iLOFT VDS Extra manual

Fermax

Fermax iLOFT VDS Extra manual

Sigtronics US-12S Installation and operating instructions

Sigtronics

Sigtronics US-12S Installation and operating instructions

KOCOM KC-MB20 user manual

KOCOM

KOCOM KC-MB20 user manual

Aiphone GT-1M-L Service manual

Aiphone

Aiphone GT-1M-L Service manual

PS Engineering PMA7000B Series Pilot's guide and operation manual

PS Engineering

PS Engineering PMA7000B Series Pilot's guide and operation manual

Genway 2018D user manual

Genway

Genway 2018D user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.