Quick Reference 930945C © 2017, CyberData Corporation, ALL RIGHTS RESERVED© 2017, CyberData Corporation, ALL RIGHTS RESERVED 930945C Quick Reference
Wall Mounting Options
Gang Box Mounting Options
Mounting Screw &
Wall Cutout
on Wall
Pre Drill Holes
to J1
Cable
Network
Backplate
Plastic Ribbed Anchor
Remove Screw & Nut
Before Installation
Mounting
Screw (3x)
Loop Wire
Clockwise
Wire
Ground
Wire
Ground
Closed
Slots
Slots
Opening
Slot
Entry
Cable
Wall Cutout
or Two Gang Box
Backplate accept
Single Gang Box
Backplate
Wall Cutout
Wire
Ground
Two Gang Box use four
Single Gang Box use two
Screw Accessory Kit
In Two Gang Box Mounting
Move Ground Cable to Center Hole
Remove Screw & Nut
Before Install to Gang Box
Mounting
Screw (3x)
Loop Wire
Clockwise
Wire
Ground
Cable
Network
Closed
Slots
Cable
Slot
Entry
Cable
Getting Started
• Download the Operations Guide PDF file, from the Downloads tab at the following webpage:
http://www.cyberdata.net/voip/011304/
• Create a plan for the locations of your Intercoms.
• WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.
• WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation
instructions.
• WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
• WARNING: This enclosure is not rated for any AC voltages!
Parts
Contacting CyberData
Parameter Factory Default Setting
IP Addressing DHCP
IP Addressa
a. Default if there is not a DHCP server present.
10.10.10.10
Web Access Username admin
Web Access Password admin
Subnet Maska255.0.0.0
Default Gatewaya10.0.0.1
(4) Plastic Ribbed Anchor (4) #6-32 FlatHead Countersunk
Machine Screw
(1) Wall Mounting Kit(1) Intercom Assembly (1) Gang Box Mounting Kit
(4) Sheet Metal Screw
Sales: (831) 373-2601 ext. 334
Support: 831-373-2601 ext. 333
Support Website: http://support.cyberdata.net/
RMA Department: (831) 373-2601 ext. 136
RMA Email: [email protected]et
RMA Status: http://support.cyberdata.net/
Warranty Information: http://support.cyberdata.net/
Corporate Headquarters
CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA
Phone: 831-373-2601
Fax: 831-373-4193
http://www.cyberdata.net/
The IP Endpoint Company
Installation Quick Reference
Singlewire InformaCast
Emergency Intercom
011304
© 2017, CyberData Corporation, ALL RIGHTS RESERVED 930945C Quick Reference Quick Reference 930945C © 2017, CyberData Corporation, ALL RIGHTS RESERVED
RTFM Button
Maximum Recommended Wall Cutout Dimensions
RTFM button (SW1)
When the device is operational and linked to a net-
work, you can use the Reset Test Function Man-
agement (RTFM) button (SW1 [see picture]) to
announce the device’s IP address or restore the
device to the factory
default settings.
To announce the device’s current IP address:
• Press and release the RTFM button within a
five second window.
Note The device will use DHCP to obtain the
new IP address (DHCP-assigned address
or default to 10.10.10.10 if a DHCP server
is not present).
To restore the device to factory default settings:
• Press and hold the RTFM button for longer
than five seconds until you hear the device
announce that it is restoring the factory default
settings.
DIMENSIONS ARE IN INCHES [MILLIMETER]
3.40 [86.4]
ø0.19 [ø4.8]
2.39 [60.8]
3.40 [86.4]
2.65 [67.3]
0.50 [12.8]
0.38 [9.5]
(4 Places)
Dimensions
Terminal Block Connections
4.53 [115.0]
4.53 [115.0]
2.22 [56.3]
DIMENSIONS ARE IN INCHES [MILLIMETER]
0.25"
Terminal Block
Wire (IN)
can accept 16 AWG wire
1
8
Alternate Power Input:
1 = +8 to +12VDC @ 1000mA Regulated Power Supply*
2 = Power Ground*
Relay Contact:
(1 A at 30 VDC for continuous loads)
3 = Relay Common
4 = Relay Normally Open Contact
5 = Sense Input
6 = Sense Ground
7 = Remote Switch "A"
8 = Remote Switch "B"
*Contacts 1 and 2 on the terminal block are only for
powering the device from a non-PoE 12VDC power
source as an alternative to Network PoE power. Use of
these contacts for any other purpose will damage the
device and void the product warranty.
34
Use a 3.17 mm (1/8-inch) flat blade
screwdriver for the terminal block screws

Other manuals for 11304

3

Other CyberData Intercom System manuals

CyberData VoIP Intercom 010935F User manual

CyberData

CyberData VoIP Intercom 010935F User manual

CyberData #011123 Manual

CyberData

CyberData #011123 Manual

CyberData 011311 Manual

CyberData

CyberData 011311 Manual

CyberData 011186 User manual

CyberData

CyberData 011186 User manual

CyberData 11186 Manual

CyberData

CyberData 11186 Manual

CyberData #011123 User manual

CyberData

CyberData #011123 User manual

CyberData 11186 User manual

CyberData

CyberData 11186 User manual

CyberData 011035 Manual

CyberData

CyberData 011035 Manual

CyberData 011306 Manual

CyberData

CyberData 011306 Manual

CyberData 11307 User manual

CyberData

CyberData 11307 User manual

CyberData 11214 User manual

CyberData

CyberData 11214 User manual

CyberData VoIP Desktop Intercom Manual

CyberData

CyberData VoIP Desktop Intercom Manual

CyberData 11214 Manual

CyberData

CyberData 11214 Manual

CyberData 11113 Manual

CyberData

CyberData 11113 Manual

CyberData 11186 User manual

CyberData

CyberData 11186 User manual

CyberData 011410 Manual

CyberData

CyberData 011410 Manual

CyberData 011414 Manual

CyberData

CyberData 011414 Manual

CyberData 3CX User manual

CyberData

CyberData 3CX User manual

CyberData 11111 User manual

CyberData

CyberData 11111 User manual

CyberData VoIP Indoor Intercom 011030 User manual

CyberData

CyberData VoIP Indoor Intercom 011030 User manual

CyberData 11186 User manual

CyberData

CyberData 11186 User manual

CyberData 011478 Manual

CyberData

CyberData 011478 Manual

CyberData 11113 User manual

CyberData

CyberData 11113 User manual

CyberData 11272 Manual

CyberData

CyberData 11272 Manual

Popular Intercom System manuals by other brands

Algo 3008 installation guide

Algo

Algo 3008 installation guide

2N Clip user manual

2N

2N Clip user manual

Comelit 6722W user manual

Comelit

Comelit 6722W user manual

Hollyland Solidcom C1 Pro user manual

Hollyland

Hollyland Solidcom C1 Pro user manual

Aiphone IS SERIES Quik start programming guide

Aiphone

Aiphone IS SERIES Quik start programming guide

RDM 481 BB D-20 installation instructions

RDM

RDM 481 BB D-20 installation instructions

Alpha Communications TekTone Tek-COM PK724 Series installation instructions

Alpha Communications

Alpha Communications TekTone Tek-COM PK724 Series installation instructions

Aiphone IP-EWST Quick setup instructions

Aiphone

Aiphone IP-EWST Quick setup instructions

Aristel AN1808-08 Quick installation guide

Aristel

Aristel AN1808-08 Quick installation guide

Commax DP-LA01M user manual

Commax

Commax DP-LA01M user manual

Fermax CITY LINE manual

Fermax

Fermax CITY LINE manual

Akuvox SDP-R29 user manual

Akuvox

Akuvox SDP-R29 user manual

Algo 8028 SIP Doorphone Installation and user guide

Algo

Algo 8028 SIP Doorphone Installation and user guide

Easydoor DJ 1T user manual

Easydoor

Easydoor DJ 1T user manual

Bticino 363511 installation manual

Bticino

Bticino 363511 installation manual

Guardian Telecom ExP-TBA Installation & operation

Guardian Telecom

Guardian Telecom ExP-TBA Installation & operation

Aiphone AP-10AS/C instructions

Aiphone

Aiphone AP-10AS/C instructions

RTS SAP612 user manual

RTS

RTS SAP612 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.