Quick Reference 931560F © 2022, CyberData Corporation, ALL RIGHTS RESERVED© 2022, CyberData Corporation, ALL RIGHTS RESERVED 931560F Quick Reference
Gooseneck Mounting
Contacting CyberData
Ground Wire
Network Cable
(Sold separately)
Weather Shroud
Backbox
Torx security screw
Faceplate mounting
Torx key
SIP Outdoor Intercom with Keypad
(4 sets included)
Carriage Bolt
Gooseneck
Cable & Wire
Create service loop
Apply RTV Silicone Sealant around mounting holes and
backside perimeter of Backbox and Weather Shroud
Carriage Bolt, Washer & Nut
(All Cables, Fasteners, Sealant and Gooseneck are not provided
(Apply Blue Loctite on threads)
unless noted otherwise.)
J1 to J1
GENERAL ALERT
Caution
Equipment Hazard: Do not use an electric
or power screwdriver to fasten the face plate
and PCB assembly to the gang box. To prevent
over-torque damage to the gasket, do not apply
more than 10 inch-pounds force. Over-torquing
will cause the gasket to tear, risk moisture intrusion,
and effectively void the manufacturer's warranty.
Note: To mount the intercom, use methods
compliant with local electrical codes.
Note: More installation and mounting
information is illustrated in the Operations Guide.
011215 Outdoor Shroud, 2X
Sales: 831-373-2601 ext. 334
Support: 831-373-2601 ext. 333
Support Website: https://support.cyberdata.net/
RMA Department Contact and Status: https://support.cyberdata.net/
Warranty Information: https://support.cyberdata.net/
Corporate Headquarters
CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA
Phone: 831-373-2601
Fax: 831-373-4193
https://www.cyberdata.net/
Typical System Installation
Getting Started
• Download the Operations Guide PDF file, from the Downloads tab at the following webpage:
https://www.cyberdata.net/products/011214
• Create a plan for the locations of your devices.
• WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.
• WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation
instructions.
• WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
• WARNING: This enclosure is not rated for any AC voltages!
Parts
Parameter Factory Default Setting
IP Addressing DHCP
IP AddressaIPv4 Link Local
Web Access Username admin
Web Access Password admin
Subnet MaskaIPv4 Link Local
Default GatewayaIPv4 Link Local
a. Default if there is not a DHCP server present.
802.3af Compliant Ethernet Switch
Intercom IP Phone IP PBX ServerIntercom Intercom
*More installation and mounting
options are available in the
Operations Guide.
Accessory Kit
Mounting Component
(1) 1/2-inch EMT
compression
connector with extra
sealing locknut
(1) 531085* Hole
plug assembly
(4) Carriage bolts
(4) Carriage bolt nuts
(4) Carriage bolt washers
(6) Security Torx Screws
Security Torx Key
(6) Phillips Screws
Optional Accessories
(for gooseneck mounting)
Optional Accessories Sold Separately
Installation Quick Reference
SIP Outdoor Intercom with Keypad
SIP Compliant
011214
The IP Endpoint Company
© 2022, CyberData Corporation, ALL RIGHTS RESERVED 931560F Quick Reference Quick Reference 931560F © 2022, CyberData Corporation, ALL RIGHTS RESERVED
Terminal Block Connections
RTFM Button
Call Button
7.480 [190.00]
Dimensions are in Inches [Millimeters]
2.284 [58.01]
5.118 [130.00]
5.198 [132.03]
Microphone
Hole
Speaker
Drain Hole
Features Dimensions (Front and Side View)
1
8
Wire (IN)
Tin Leads
Approx. 1/4” or
6mm
Terminal Block
can accept 16 AWG wire
Alternate Power Input:
1 = +8 to +12VDC @ 1000mA Regulated Power Supply*
2 = Power Ground*
Relay Contact:
(1 A at 30 VDC for continuous loads)
3 = Relay Common
4 = Relay Normally Open Contact
5 = Sense Input
6 = Sense Ground
7 = Remote Switch "A"
8 = Remote Switch "B"
*Contacts 1 and 2 on the terminal block are only for
powering the device from a non-PoE 12VDC power
source as an alternative to Network PoE power. Use of
these contacts for any other purpose will damage the
device and void the product warranty.
34
Use a 3.17 mm (1/8-inch) flat blade
screwdriver for the terminal block screws
RTFM button (SW1)
When the device is operational and linked to a network, you
can use the Reset Test Function Management (RTFM) but-
ton (SW1 [see picture]) to announce the device’s IP
address or restore the device to the factory
default settings.
To announce the device’s current IP address:
• Press and release the RTFM button within a five
second window.
Note The device will use DHCP to obtain the new IP
address (DHCP-assigned address or default to
IPv4 Link Local if a DHCP server is not present).
To restore the device to factory default settings:
• Press and hold the RTFM button for longer than five
seconds until you hear the device announce that it is
restoring the factory default settings.
Dimensions (Rear View and Mounting Holes)
Wall Mounting
0.000 [0.00]
0.869 [22.07]
2.559 [65.00]
4.249 [107.93]
5.118 [130.00]
0.000 [0.00]
2.050 [52.07]
3.740 [95.00]
5.430 [137.93]
7.480 [190.00]
Ø0.280 [Ø7.11]
(4 Places)
Ø0.876 [Ø22.25]
Dimensions are in inches [millimeters]
Conduit
Ground Wire
Network Cable
1/2" EMT
Compression
connector
1/2" EMT
anchor screw
1/4"
1/4" Concrete
(Sold separately)
Weather Shroud
Wall Anchor
Torx key
SIP Outdoor Intercom with Keypad
through side Conduit Hole
Network and Ground cables
Cables
create service loop
Apply RTV Silicone Sealant Around Mounting Holes and
Backside Perimeter of Backbox and Weather Shroud
with
sealing locknut
(Sold separately)
Torx security screw
Faceplate mounting
(All Cables, Fasteners, Sealant and Gooseneck are not provided
unless noted otherwise.)
with Compression connector
Remove hole plug assembly then
Install it onto the rear conduit hole
*
*
J1 to J1
Note: For flush mount installations, purchase the 011442 Flush
Mount Kit, 2x (sold separately). For more information, go to:
https://www.cyberdata.net/products/011442
Note: To mount the device, use methods
compliant with local electrical codes.
Note: More installation and mounting information
is illustrated in the Operations Guide.
Caution
Equipment Hazard: Do not use an electric or power screwdriver to fasten the face plate and PCB assembly to
the gang box. To prevent over-torque damage to the gasket, do not apply more than 10 inch-pounds force.
Over-torquing will cause the gasket to tear, risk moisture intrusion, and effectively void the manufacturer's
warranty.
GENERAL ALERT
011215 Outdoor Shroud, 2X

Other CyberData Intercom System manuals

CyberData 11214 User manual

CyberData

CyberData 11214 User manual

CyberData 11113 User manual

CyberData

CyberData 11113 User manual

CyberData 11186 User manual

CyberData

CyberData 11186 User manual

CyberData 11305 Manual

CyberData

CyberData 11305 Manual

CyberData VoIP Indoor Intercom 011030 Manual

CyberData

CyberData VoIP Indoor Intercom 011030 Manual

CyberData 011307 Manual

CyberData

CyberData 011307 Manual

CyberData 011410 Manual

CyberData

CyberData 011410 Manual

CyberData 11305 User manual

CyberData

CyberData 11305 User manual

CyberData 11113 User manual

CyberData

CyberData 11113 User manual

CyberData VoIP Indoor Intercom 011030 User manual

CyberData

CyberData VoIP Indoor Intercom 011030 User manual

CyberData VoIP Intercom 010935B User manual

CyberData

CyberData VoIP Intercom 010935B User manual

CyberData 11272 User manual

CyberData

CyberData 11272 User manual

CyberData 11214 Manual

CyberData

CyberData 11214 Manual

CyberData 11111 User manual

CyberData

CyberData 11111 User manual

CyberData 11214 Manual

CyberData

CyberData 11214 Manual

CyberData 11308 User manual

CyberData

CyberData 11308 User manual

CyberData 11186 User manual

CyberData

CyberData 11186 User manual

CyberData 11186 User manual

CyberData

CyberData 11186 User manual

CyberData 011530 Manual

CyberData

CyberData 011530 Manual

CyberData 011211 series Manual

CyberData

CyberData 011211 series Manual

CyberData 11111 User manual

CyberData

CyberData 11111 User manual

CyberData #011123 User manual

CyberData

CyberData #011123 User manual

CyberData 11307 User manual

CyberData

CyberData 11307 User manual

CyberData 11035 User manual

CyberData

CyberData 11035 User manual

Popular Intercom System manuals by other brands

Algo 3008 installation guide

Algo

Algo 3008 installation guide

2N Clip user manual

2N

2N Clip user manual

Comelit 6722W user manual

Comelit

Comelit 6722W user manual

Hollyland Solidcom C1 Pro user manual

Hollyland

Hollyland Solidcom C1 Pro user manual

Aiphone IS SERIES Quik start programming guide

Aiphone

Aiphone IS SERIES Quik start programming guide

RDM 481 BB D-20 installation instructions

RDM

RDM 481 BB D-20 installation instructions

Alpha Communications TekTone Tek-COM PK724 Series installation instructions

Alpha Communications

Alpha Communications TekTone Tek-COM PK724 Series installation instructions

Aiphone IP-EWST Quick setup instructions

Aiphone

Aiphone IP-EWST Quick setup instructions

Aristel AN1808-08 Quick installation guide

Aristel

Aristel AN1808-08 Quick installation guide

Commax DP-LA01M user manual

Commax

Commax DP-LA01M user manual

Fermax CITY LINE manual

Fermax

Fermax CITY LINE manual

Akuvox SDP-R29 user manual

Akuvox

Akuvox SDP-R29 user manual

Algo 8028 SIP Doorphone Installation and user guide

Algo

Algo 8028 SIP Doorphone Installation and user guide

Easydoor DJ 1T user manual

Easydoor

Easydoor DJ 1T user manual

Bticino 363511 installation manual

Bticino

Bticino 363511 installation manual

Guardian Telecom ExP-TBA Installation & operation

Guardian Telecom

Guardian Telecom ExP-TBA Installation & operation

Aiphone AP-10AS/C instructions

Aiphone

Aiphone AP-10AS/C instructions

RTS SAP612 user manual

RTS

RTS SAP612 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.