manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CyberData
  6. •
  7. Intercom System
  8. •
  9. CyberData 11272 Manual

CyberData 11272 Manual

Other manuals for 11272

3

Other CyberData Intercom System manuals

CyberData 11308 Manual

CyberData

CyberData 11308 Manual

CyberData 11272 User manual

CyberData

CyberData 11272 User manual

CyberData 11304 User manual

CyberData

CyberData 11304 User manual

CyberData VoIP Desktop Intercom Manual

CyberData

CyberData VoIP Desktop Intercom Manual

CyberData #011123 User manual

CyberData

CyberData #011123 User manual

CyberData 11214 User manual

CyberData

CyberData 11214 User manual

CyberData 011410 Manual

CyberData

CyberData 011410 Manual

CyberData 11304 User manual

CyberData

CyberData 11304 User manual

CyberData 11310 Manual

CyberData

CyberData 11310 Manual

CyberData 11214 User manual

CyberData

CyberData 11214 User manual

CyberData 11305 User manual

CyberData

CyberData 11305 User manual

CyberData 11214 User manual

CyberData

CyberData 11214 User manual

CyberData 11035 User manual

CyberData

CyberData 11035 User manual

CyberData 011530 Manual

CyberData

CyberData 011530 Manual

CyberData 10935 User manual

CyberData

CyberData 10935 User manual

CyberData 11113 User manual

CyberData

CyberData 11113 User manual

CyberData 011414 Manual

CyberData

CyberData 011414 Manual

CyberData VoIP Indoor Intercom 011030 User manual

CyberData

CyberData VoIP Indoor Intercom 011030 User manual

CyberData #011123 Manual

CyberData

CyberData #011123 Manual

CyberData 11307 User manual

CyberData

CyberData 11307 User manual

CyberData 11186 User manual

CyberData

CyberData 11186 User manual

CyberData 011414 User manual

CyberData

CyberData 011414 User manual

CyberData 011035 Manual

CyberData

CyberData 011035 Manual

CyberData 011490 Manual

CyberData

CyberData 011490 Manual

Popular Intercom System manuals by other brands

Videx VRDK1 (25H) Technical manual

Videx

Videx VRDK1 (25H) Technical manual

Auta COMPACT VISUALTECH manual

Auta

Auta COMPACT VISUALTECH manual

Aiphone LC-10S instructions

Aiphone

Aiphone LC-10S instructions

Aiphone PD-1 instructions

Aiphone

Aiphone PD-1 instructions

Aiphone JF-DVF-HID-I instructions

Aiphone

Aiphone JF-DVF-HID-I instructions

Comelit 4893M Technical manual

Comelit

Comelit 4893M Technical manual

MGL Avionics V16 manual

MGL Avionics

MGL Avionics V16 manual

SSS Siedle BVI 750-0 Installation & programming

SSS Siedle

SSS Siedle BVI 750-0 Installation & programming

urmet domus AIKO 1716/1 quick start guide

urmet domus

urmet domus AIKO 1716/1 quick start guide

urmet domus IPerVoice 1039 Installation

urmet domus

urmet domus IPerVoice 1039 Installation

Alpha Communications STR QwikBus TT33-2 Installation, programming, and  user's manual

Alpha Communications

Alpha Communications STR QwikBus TT33-2 Installation, programming, and user's manual

Monacor ICM-20H instruction manual

Monacor

Monacor ICM-20H instruction manual

Logenex A202CR Installation & programming

Logenex

Logenex A202CR Installation & programming

Quantum QR5 Installation and programming manual

Quantum

Quantum QR5 Installation and programming manual

EVGA XR1 quick guide

EVGA

EVGA XR1 quick guide

Vidos duo M1021 user manual

Vidos

Vidos duo M1021 user manual

Savant DOR-SMS-00 Deployment guide

Savant

Savant DOR-SMS-00 Deployment guide

SSS Siedle BTSV 850-03 operating instructions

SSS Siedle

SSS Siedle BTSV 850-03 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Quick Reference 931606B © 2019, CyberData Corporation, ALL RIGHTS RESERVED© 2019, CyberData Corporation, ALL RIGHTS RESERVED 931606B Quick Reference
Mounting Options
Contacting CyberData
Fold Down All Flagnuts
before Inserting into Wall Cutout
Cutout
Network Cable Assembly
(Not Provided)
Screws
Faceplate
2 Gang Box
Torx Drive)
Assembly Points Upward,
Arrow Labels Must
This will Ensure
Intrusion Sensor
Function Properly
Wall
Inside Gangbox
Create Service Loop
Torx Key
(Phillip Drive)
(Security
Mounting
Screws
Mounting
Flagnuts
(4 Places)
K.O.
to J1
6.03 inches
[153mm]
5.28 inches
[134mm]
Network Cable
J1
To mount the Intercom:
1. Make a wall cutout as shown in the picture.
2. Use a flat blade screwdriver to remove the knockout (KO) of the gang box.
3. Feed the ground wire (shown in the “Ground Connection” section) and the network cable from the wall cutout through the
knockout hole of the gang box.
4. Create a service loop for both the ground wire and network cable.
5. Plug the network cable into the J1 connector.
6. Make sure that the arrow labels on the sides of the gang box are pointing up. This will ensure that the intrusion sensor
functions properly.
7. Fold down all of the flagnuts, and then insert the gang box into the wall cutout.
8. Tighten the flagnuts with a size #2 Phillips screwdriver.
9. Use a size #2 Phillips screwdriver to secure the Intercom faceplate assembly to the gang box with either Phillips drive
screws or security Torx drive screws.
Sales: (831) 373-2601 ext. 334
Support: 831-373-2601 ext. 333
Support Website: http://support.cyberdata.net/
RMA Department: (831) 373-2601 ext. 136
RMA Email: [email protected]
RMA Status: http://support.cyberdata.net/
Warranty Information: http://support.cyberdata.net/
Corporate Headquarters
CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA
Phone: 831-373-2601
Fax: 831-373-4193
http://www.cyberdata.net/
Typical System Installation
Getting Started
• Download the Operations Guide PDF file, from the Downloads tab at the following webpage:
https://www.cyberdata.net/products/011272
• Create a plan for the locations of your Intercoms.
• WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.
• WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation
instructions.
• WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
• WARNING: This enclosure is not rated for any AC voltages!
Intercom Parts
Tool required for assembly: A size #2 Phillips screwdriver
Parameter Factory Default Setting
IP Addressing DHCP
IP Addressa10.10.10.10
Web Access Username admin
Web Access Password admin
Subnet Maska255.0.0.0
Default Gatewaya10.0.0.1
a. Default if there is not a DHCP server present.
802.3af Compliant Ethernet Switch
Intercom IP Phone IP PBX ServerIntercom Intercom
*More installation and mounting
options are available in the
Operations Guide.
(4) #6 X 3/8-inch,100 Deg.,
Flat Head, Self-Tapping Screw
(1) Intercom Assembly (1) Mounting Kit
(4) #6 X 3/8-inch,100 Deg.,
Flat Head T15 Security Pin Torx
Screw
(1) T15 Security Pin Torx Key
(1) Optional Mounting Kit
The IP Endpoint Company
Installation Quick Reference
SIP Indoor Intercom Flush Mount
SIP Compliant
011272
© 2019, CyberData Corporation, ALL RIGHTS RESERVED 931606B Quick Reference Quick Reference 931606B © 2019, CyberData Corporation, ALL RIGHTS RESERVED
RTFM Button
Ground Connection
When the device is operational and linked to a network,
you can use the Reset Test Function Management
(RTFM) button (SW1 [see picture]) to announce the
device’s IP address or restore the device to the factory
default settings.
To announce the device’s current IP address:
• Press and release the RTFM button within a five
second window.
Note The device will use DHCP to obtain the new IP
address (DHCP-assigned address or default to
10.10.10.10 if a DHCP server is not present).
To restore the device to factory default settings:
• Press and hold the RTFM button for longer than five
seconds until you hear the device announce that it is
restoring the factory default settings.
RTFM button (SW1)
inside Backbox
Create Service Loop
Knock Out
#6 Ring Terminal
Nut (Pre-Installed)
Ground Lug
Cutomer Provide
Ground Wire
Ground Lug Fits
Dimensions
Terminal Block Connections
6.840 [173.7]
Dimensions are in Inches [Millimeter]
2.419 [61.4]
5.860 [148.8]
0.170 [4.3]
1
8
Wire (IN)
Tin Leads
Approx. 1/4” or
6mm
Terminal Block
can accept 16 AWG wire
Alternate Power Input:
1 = +8 to +12VDC @ 1000mA Regulated Power Supply*
2 = Power Ground*
Relay Contact:
(1 A at 30 VDC for continuous loads)
3 = Relay Common
4 = Relay Normally Open Contact
5 = Sense Input
6 = Sense Ground
7 = Remote Switch "A"
8 = Remote Switch "B"
*Contacts 1 and 2 on the terminal block are only for
powering the device from a non-PoE 12VDC power
source as an alternative to Network PoE power. Use of
these contacts for any other purpose will damage the
device and void the product warranty.
34
Use a 3.17 mm (1/8-inch) flat blade
screwdriver for the terminal block screws