Quick Reference 931642B © 2019, CyberData Corporation, ALL RIGHTS RESERVED© 2019, CyberData Corporation, ALL RIGHTS RESERVED 931642B Quick Reference
Mounting Options
Contacting CyberData
To mount the Intercom:
1. Make a wall cutout as shown in the picture.
2. Use a flat blade screwdriver to remove the knockout (KO) of the gang box.
3. Feed the ground wire (shown in the “Ground Connection” section) and the network cable from the wall cutout through the
knockout hole of the gang box.
4. Create a service loop for both the ground wire and network cable.
5. Plug the network cable into the J1 connector.
6. Make sure that the arrow labels on the sides of the gang box are pointing up. This will ensure that the intrusion sensor
functions properly.
7. Fold down all of the flagnuts, and then insert the gang box into the wall cutout.
8. Tighten the flagnuts with a size #2 Phillips screwdriver.
9. Use either a size #2 Phillips screwdriver or a Torx Driver Bit to secure the Intercom faceplate assembly to the gang box
with either Phillips drive screws or security Torx drive screws.
Before Insert the Backbox
into the Wall
Cutout
Network Cable are
Not Provided
Screws
Faceplate
Torx Drive)
Assembly
Ground Wire &
Point Upward.
Arrow Labels must
This will Ensure
the Intrusion Sensor
Function Properly.
Wall
Inside Gang Box
Create Service Loop
Torx Key
(Phillip Drive)
(Security
Mounting
Screws
Mounting
(4 Places)
Fold Down all Flagnuts
Knockout
to J1
6.03 inches
[153mm]
5.28 inches
[134mm]
Network Cable
J1
Sales: (831) 373-2601 ext. 334
Support: 831-373-2601 ext. 333
Support Website: http://support.cyberdata.net/
RMA Department: (831) 373-2601 ext. 136
RMA Status: http://support.cyberdata.net/
Warranty Information: http://support.cyberdata.net/
Corporate Headquarters
CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA
Phone: 831-373-2601
Fax: 831-373-4193
http://www.cyberdata.net/
Typical System Installation
Getting Started
• Download the Operations Guide PDF file, from the Downloads tab at the following webpage:
https://www.cyberdata.net/products/011308
• Create a plan for the locations of your Intercoms.
• WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.
• WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation
instructions.
• WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
• WARNING: This enclosure is not rated for any AC voltages!
Intercom Parts
Tool required for assembly: A size #2 Phillips screwdriver
Parameter Factory Default Setting
IP Addressing DHCP
IP Addressa10.10.10.10
Web Access Username admin
Web Access Password admin
Subnet Maska255.0.0.0
Default Gatewaya10.0.0.1
a. Default if there is not a DHCP server present.
802.3af Compliant Ethernet Switch
Intercom IP Phone InformaCast ServerIntercom Intercom
*More installation and mounting
options are available in the
Operations Guide.
(4) #6 X 3/8-inch,100 Deg.,
Flat Head, Self-Tapping Screw
(1) Intercom Assembly (1) Mounting Kit
(4) #6 X 3/8-inch,100 Deg.,
Flat Head T15 Security Pin Torx
Screw
(1) T15 Security Pin Torx Key
(1) Optional Mounting Kit
The IP Endpoint Company
Installation Quick Reference
InformaCast Enabled Indoor
Intercom with Keypad, Flush Mount
011308