4P642495-1A–2022.02 Page 1of 52
Design guide Modbus Interface DIII
EKMBDXB7V1
Table of Contents
Safety Precautions ..............................................................................................................................................3
1. Introduction....................................................................................................................................................3
1.1 System layout ...........................................................................................................................................3
1.2 Limitations ................................................................................................................................................4
1.3 Specifications............................................................................................................................................4
1.3.1 Dimensions and field wiring ..............................................................................................................5
1.3.2 Wiring diagram ..................................................................................................................................6
1.3.3 LED meaning ......................................................................................................................................6
1.3.4 Termination resistance (SS switches) ................................................................................................6
1.3.5 Push buttons......................................................................................................................................7
1.3.6 Dipswitch meaning ............................................................................................................................7
1.4 Overview of compatible Daikin units ranges with DIII connection...........................................................8
1.5 Overview of compatibilty with other DIII centralised control equipment................................................8
2. Modbus communication...............................................................................................................................10
2.1 Modbus Interface DIII settings................................................................................................................10
2.2 Communication format ..........................................................................................................................11
2.2.1 Function format ...............................................................................................................................11
2.2.2 Character format .............................................................................................................................14
2.2.3 Silent internal time ..........................................................................................................................14
2.2.5 Response time .................................................................................................................................14
2.3 Communication procedure.....................................................................................................................15
2.3.1 System initialisation.........................................................................................................................15
2.3.2 Monitor and operate units from the BMS .......................................................................................16
2.3.3 Other DIII devices exist in the same system ....................................................................................20
3. Modbus registers..........................................................................................................................................21
3.1. Input registers........................................................................................................................................21
3.2 Holding registers.....................................................................................................................................32
4. Software of Modbus Interface DIII ...............................................................................................................40
4.1 Software releases ...................................................................................................................................40
4.2 Software update with Updater...............................................................................................................40
4.2.1 Updater............................................................................................................................................40
4.2.2 Method 1) Update with the PC USB cable EKPCCAB*. ....................................................................41
4.2.3 Method 2) Update with a USB/RS485 converter.............................................................................43
5. Modbus Interface DIII test operation ...........................................................................................................45