T Sense Keypad Quick User & Installer Manual Rev 2.0
Remark : Based on Communication Option’s Table (Refer previous table, page 6)
- Enter [0000] # to delete/clear CMS account number
Or
-Press [31] to enter command and press [1] # to set receiver type as personal type to disable CMS account number
Zone Circuit Type Setting
Zone number ON means the zone
is EOL type else NO/NC type
Normally
Open/Normally
Close
Zone number ON means the zone
is NO type else NC.
Remark : Based on Zone Circuit Type Setting’s Table (Refer above table)
- Press the number to toggle the setting
Keyswitch and Tamper Setting
Zone 1 ON mean enable
keyswitch
Zone 2 ON mean the keyswitch is
Momentary else Latch Remote
Control
Zone 3 ON mean keyswitch is NC
type else NO type
Zone 4 ON mean enable
keyswitch Siren toot else Strobe
Light blink
(Toot once/Blink 3 sec: ARM;
Toot twice/Blink 8 sec: DISARM)
Zone 1 ON mean enable Tamper
Zone 2 ON mean Tamper
activated 24 hours else activate
during Arm
Zone 3 ON mean Tamper is NC
type else NO
Remark : Keyswitch and Tamper Setting’sTable (Refer above table)
- Press the number to toggle the setting
Programmable Output Setting
Zone 1 ON mean enable OC1
Zone 2 ON mean enable OC1
with latch high output
Zone 3 ON mean enable OC1
with latch low output
Zone 4 ON mean enable OC1
with momentary high output
Zone 5 ON mean enable OC1
with momentary low output
Zone 6 ON mean OC1 activated in
alarm mode else arm & disarm
mode
(Zone 2 to zone 5 will toggle)
Zone 1 ON mean enable OC2
Zone 2 ON mean enable OC2
with latch high output
Zone 3 ON mean enable OC2
with latch low output
Zone 4 ON mean enable OC2
with momentary high output
Zone 5 ON mean enable OC2
with momentary low output
Zone 6 ON mean OC2 activated in
alarm mode else arm & disarm
mode
(Zone 2 to zone 5 will toggle)