Daikin T Sense AX1 Instruction Manual

Security
&
Home Automation System
QUICK USER &
INSTALLER MANUAL
(REVISION 2.0)

T Sense Keypad Quick User & Installer Manual Rev 2.0
ARM AND DISARM SYSTEM
Default Master Pin 111 111
QUICK ARM
ARM with PIN
DISARM With PIN
Auto Home
▪Press & hold button [1] for 2 seconds
If enable Partition Option
▪Press [1 or 2] + #
Press 1 for partition 1
Press 2 for partition 2
▪Press [Master PIN] + [#]
By default, keypad will arm partition
1 only
If enable Partition Option
▪Press [Master PIN] +[#]+[1 or 2]+[#]
Press 1 for partition 1
Press 2 for partition 2
▪Press [Master PIN] + [#]
If enable Partition Option
▪Press [Master PIN]+ [#] +[1 or 2] +[#]
Press 1 for partition 1
Press 2 for partition 2
Day
▪Press & hold button [2] for 2 seconds
If enable Partition Option
▪Press [1 or 2] + #
Press 1 for partition 1
Press 2 for partition 2
Night
▪Press & hold button [3] for 2 seconds
If enable Partition Option
▪Press [1 or 2] + #
Press 1 for partition 1
Press 2 for partition 2
Force
▪Press & hold button [4] for 2 seconds
If enable Partition Option
▪Press [1 or 2] + #
Press 1 for partition 1
Press 2 for partition 2
REMARKS
-Default Master PIN = 111111
-The ARMED LED (RED) is ON if the system is armed.
ENABLE PARTITION OPTION
Steps to Enable Partition Option
▪Press [▼] for 2 sec + [▼for PART] + [Press 1 to toggle] + [#]
REMARKS
-By default, partition option is disabled
AUTOMATION CONTROL
COMMAND
▪Press & hold button [5] for 2 seconds
▪Press the relevant module number (01 to 16) to toggle output
▪Press * to exit automation menu
REMARKS
-The keypad will beep twice upon confirmation or else, an error tone will sound.
- To on/off all output: [00] is pressed to toggle all output. System priority to turn OFF all output if there is any output is ON.
1

T Sense Keypad Quick User & Installer Manual Rev 2.0
CLEAR ALARM MEMORY
COMMAND
INFORMATION
▪Press & hold button [6] for 2 seconds
▪Clear Zones, Strobe Light & Ext Comm. Error
DOOR CHIME
COMMAND
▪Hold [7] for 2 sec + [Zone number 01 to 16] + [#]
REMARKS
-When door chime is activated, the keypad will sound each time the designed zone is triggered
SYSTEM SERVICE
COMMAND
INFORMATION
▪Press & hold button [8] for 2 seconds
▪Press the corresponding number to check the trouble
▪Press [*] to Exit
Zone 1 (AC Power Loss)
Zone 2 (Low Battery)
Zone 3 (External Communication Failure)
Zone 4 (Telephone Line Loss)
Zone 5 (Tamper Zone)
REMARKS
- Trouble LED (RED) is ON when there is system trouble
- Trouble LED is OFF when there is no system trouble
BYPASS ZONE AND RESTORED
BYPASS
ZONE RESTORE
▪Press & hold button [9] for 2 seconds
▪Press [Zone Number]
▪Press [#] to save and exit
Press [01] to [16] to select zone 1 to 16
Key in 2 digit
▪Press & hold button [9] for 2 seconds
▪Press [Zone Number]
▪Press [#] to save and exit
Press [01] to [16] to select zone 1 to 16
Key in 2 digit
REMARKS
- Press [01] to [16] to select zone 1 to 16 again in this menu in order to have quick BYPASS and ZONE RESTORE
- In the normal mode, bypass zone will blinking to show that zone is already bypass.
-Bypass zones are cleared after system is disarmed.
KEY LOCK
COMMAND
[COM] + [1] + [#]
REMARKS
-Key lock is design to avoid miss control by guest or kids.
- The “Key lock” icon on LCD will turn ON to indicate key lock is enabled and toggle based
PRECAUTION
-If user key in wrong password for 10x,the keypad will automatically lock by itself for 3 minutes
SERVICE
1 2 3 4 5
2

T Sense Keypad Quick User & Installer Manual Rev 2.0
KEYPAD SETTING
Keypad Setting
Command
Partition Option
Press [▼] for 2 sec + [▼for PART] + [Press 1 to toggle] + [#]
ON/OFF Keypad backlight
Press [▼] for 2 sec + [▼for LIGHT] + [Press 1 to toggle] + [#]
ON/OFF keypad Arm tone
Press [▼] for 2 sec + [▼for A TONE] + [Press 1 to toggle] + [#]
ON/OFF entry & exit delay buzzer tone
Press [▼] for 2 sec + [▼for E TONE] + [Press 1 to toggle] + [#]
ON/OFF key press tone
Press [▼] for 2 sec + [▼for K TONE] + [Press 1 to toggle] + [#]
Reset default setting
Press [▼] for 2 sec + [▼for RESET] + [#] + [Yes] + [#]
TESTING THE SYSTEM
TESTING
Command
Walk Test
Enter : Press and hold [▲] for 2sec + [▼for WALK] + [#]
Exit Walk Test : Press [#]
Bell Test
Press and Hold [▲] for 2sec + [▼for BELL] + [#]
CMS Test
Press and Hold [▲] for 2 sec + [▼for CMS] + [#]
Battery Test
Press and Hold [▲] for 2sec + [▼for BATT] + [#]
Identification Test
Press and Hold [▲] for 2 sec + [▼for IDEN] + [#]
Remark
Please refer to the identification test table
IDENTIFICATION TEST TABLE
[▲] / [▼] to scroll System Identification and IO Identification
System Identification
IO Identification
Zone number
Description
Zone number
Description
1
Keypad 1
1
Output 1
2
Keypad 2
2
Output 2
3
Keypad 3
3
Output 3
4
Keypad 4
4
Output 4
5
Keypad 5
5
Output 5
6
Keypad 6
6
Output 6
7
Keypad 7
7
Output 7
8
Keypad 8
8
Output 8
9
Voice
9
Output 9
10
AIM
10
Output 10
11
WSM
11
Output 11
12
Zone Expander 1
12
Output 12
13
IO Expander 1
13
Output 13
14
IO Expander 2
14
Output 14
15
-
15
Output 15
16
-
16
Output 16
IDENTIFICATION TEST TABLE
3

T Sense Keypad Quick User & Installer Manual Rev 2.0
USER PROGRAMMING SUMMARY Default Master Pin 111 111
Description
Command
Enter User Programming Mode
[Master Pin] + [COM] + [#]
Exit User Programming Mode
Press and Hold [*] for 2 sec
Edit Master Pin
[▼for Pin] + [#] + [▼for Master] + [#] + [New Pin] + [#] + [Re-enter Pin] + [#]
*Edit User 1 - 7 Pin
[▼for Pin] + [#] + [▼for User 1 - 7] + [#] + [New Pin] + [#] + [Re-enter Pin] + [#] +
[Access Level] + [#] + [Partition] + [#]
*Edit Guest Pin
[▼for Pin] + [#] + [▼for Guest] + [#] + [New Pin] + [#] + [Re-enter Pin] + [#] +
[Access Level] + [#] + [Partition] + [#] + [Valid Day] + [#]
* Remark [Access Level] –Refer to create/edit User 1 –7 Pin, Guest/Duress Pin
Authority for user code can be set according to details below:
Key [1] –Arm Enable (1)/ Disable (0), Key [2] –Disarm Enable (1)/ Disable (0)
Key [3] –Bypass Enable (1)/ Disable (0), Key [4] –Open/ Close Report (1)/ Disable (0)
Edit Duress Pin
[▼for Pin] + [#] + [▼for Duress] + [#] + [4 digit New Pin] + [#] + [Re-enter NEW PIN]
+ [#]
Program Clock
[▼for Timer] + [#] + [▼for Clock] + [#] + [Set Time] + [#]
**Program Arm Timer
[▼for Timer] + [#] + [▼for Arm] + [#] + [Set Time] + [#] + [Select Partition] + [#]
**Program Disarm Timer
[▼for Timer] + [#] + [▼for Disarm] + [#] + [Set Time] + [#] + [Select Partition] + [#]
**Remark [Select Partition] –Refer to Program Arm/Disarm Timer
User need to enable partition option to select partition. The steps as below:
Press [▼] for 2 sec + [▼for Partition Opt] + [Press 1 to toggle] + [#]
Delete Arm Timer
[▼for Timer] + [#] + [▼for Arm] + [#] + [0] + [#]
Delete Disarm Timer
[▼for Timer] + [#] + [▼for Disarm] + [#] + [0] + [#]
Program ON IO Timer
[▼for Timer] + [#] + [▼for IO On 1 - 4] + [#] + [Set Time] + [#] + [Output] + [#]
Program OFF IO Timer
[▼for Timer] + [#] + [▼for IO Off 1 - 4] + [#] + [Set Time] + [#] + [Output] + [#]
Delete ON IO Timer
[▼for Timer] + [#] + [▼for IO On 1 - 4] + [#] + [0] + [#]
Delete OFF IO Timer
[▼for Timer] + [#] + [▼for IO Off 1 - 4] + [#] + [0] + [#]
Program Personal Telephone
Number
[▼for Phone] + [#] + [▼for Phone 1 - 4] + [#] + [Telephone Number] + [#]
Delete Personal Telephone
Number
[▼for Phone] + [#] + [▼for Phone 1 - 4] + [#] + [0] + [#]
Installer Access Setting
[▼for Extra] + [#] + [▼for Ins Ac] + [#] + [Press 1 to toggle] + [#]
Phone Line Loss Detection Setting
[▼for Extra] + [#] + [▼for Ph Det] + [#] + [Press 1 to toggle] + [#]
PC Communication Setting
[▼for Extra] + [#] + [▼for PC Com] + [#] + [Press 1 to toggle] + [#]
4

T Sense Keypad Quick User & Installer Manual Rev 2.0
INSTALLER PROGRAMMING SHEET
Default Installer Pin 12345
Enter Installer programming mode: [INSTALLER CODE] +
[COM] + [#]
Symbol:
Exit Installer programming mode: Press and hold [*] for 2
seconds
Enable
Back to Installer programming main page: [*]
Disable
x
Unused
PC
Display
Item
Description
Zone Display (Default Setting)
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
Zone Type Setting
01
DELAY
Delay Zone
Zone number ON mean the zone
is assigned as Delay Zone
02
INSTAN
Instant Zone
Zone number ON mean the zone
is assigned as Instant Zone
03
INTER
Interior Zone
Zone number ON mean the zone
is assigned as Interior Zone
04
24 HR
24 Hour Zone
Zone number ON mean the zone
is assigned as 24 Hour Zone
05
LIGHT
Light Zone
Zone number ON mean the zone
is assigned as Light Zone
06
SILENT
Silent Zone
Zone number ON mean the zone
is assigned as silent Zone
Remark : Based on Zone Type Setting’s Table (Refer above table)
-Press the number to toggle the setting
Alarm Delay Setting
07
ENTRY1
Partition 1 Entry
Delay Timer
From 0 to 200 seconds
030#
08
ENTRY2
Partition 2 Entry
Delay Timer
From 0 to 200 seconds
000#
09
EXIT1
Partition 1 Exit
Delay Timer
From 0 to 200 seconds
060#
10
EXIT2
Partition 2 Exit
Delay Timer
From 0 to 200 seconds
000#
11
BELL
Bell Audible Time
From 1 to 30 minutes, 0 =
continuous
005#
Zone Partition
14
ZN
NUM
Individual Zone
Partition
Key in zone number
(01 - 16 #)
Part
Partition
Set 1 for partition 1. 2 for
partition 2.
1#
Zone Sensitivity Setting
16
ZN
NUM
Individual Zone
Sensitivity
Key in zone number
(01 - 16 #)
ZN SEN
Sensitivity level
From 1 to 100.
Sensitivity level x 10ms.
006#
17
P GRP
Zone Pulse Count
Group
Zone number ON mean the zone
is programmed to the zone pulse
count group
18
P CTR
Zone Pulse
Counter
From 1 to 255 times. If counter
exceed, zone pulse count group
will trigger
002#
19
P TMR
Zone Pulse
Counter Reset
Timer
From 1 to 255 seconds. Zone
pulse counter reset timer
090#
5

T Sense Keypad Quick User & Installer Manual Rev 2.0
Reporting Setting
30
TEL CT
Telephony
Control
Zone 1 ON mean enable DTMF
Dialling ELSE Pulse Dialling
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Zone 2 ON mean enable Double
Call
31
RCV TY
Receiver Type
Zone 1 ON mean Receiver 1 is
Personal Reporting else CMS
reporting
x
x
x
x
x
x
x
x
x
x
x
x
Zone 2 ON mean Receiver 2 is
Personal Reporting else CMS
reporting
Zone 3 ON mean Receiver 3 is
Personal Reporting else CMS
reporting
Zone 4 ON mean Receiver 4 is
Personal Reporting else CMS
reporting
32
RCV OP
Receiver Options
Zone 1 ON mean Receiver 1 is
Permanent else Backup
x
x
x
x
x
x
x
x
x
x
x
x
Zone 2 ON mean Receiver 2 is
Permanent else Backup
Zone 3 ON mean Receiver 3 is
Permanent else Backup
Zone 4 ON mean Receiver 4 is
Permanent else Backup
33
REPORT
System Status
Report
Zone 1 ON mean enable Keypad
Alarm Reporting
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Zone 2 ON mean enable System
Status (Combination of function
below)
A: System Status
B: Open Report
C: Close Report
D: System Reset Report
E: CMS Periodic Report
(*Proceed to 39 to set CMS
Periodic Test)
G: Alarm Restore Reporting
H: Bypass & Bypass Restore
Reporting
34
ZN RPT
Zone Alarm
Reporting
Zone number ON mean enable
Alarm Reporting
Remark : Based on Reporting Setting’s Table (Refer above table)- Press the number to toggle the setting
Communication Options
35
ACC 1
CMS Account
Number 1
4 digit CMS account number 1
0000#
36
ACC 2
CMS Account
Number 2
4 digit CMS account number 2
0000#
37
ACC 3
CMS Account
Number 3
4 digit CMS account number 3
0000#
38
ACC 4
CMS Account
Number 4
4 digit CMS account number 4
0000#
39
PERIOD
CMS Periodic Test
Report
From 0 to 24 hours
000#
40
RING
Ring Number
From 1 to 99 rings
010#
41
DL ATP
Dial Attempts
From 0 to 15 times
005#
42
DELAY
Delay Before Dial
Timer
From 0 to 150
000#
43
REDIAL
Redial Timer
From 0 to 10
000#
6

T Sense Keypad Quick User & Installer Manual Rev 2.0
Remark : Based on Communication Option’s Table (Refer previous table, page 6)
- Enter [0000] # to delete/clear CMS account number
Or
-Press [31] to enter command and press [1] # to set receiver type as personal type to disable CMS account number
Zone Circuit Type Setting
50
EOL
End of Line
Zone number ON means the zone
is EOL type else NO/NC type
51
NO NC
Normally
Open/Normally
Close
Zone number ON means the zone
is NO type else NC.
Remark : Based on Zone Circuit Type Setting’s Table (Refer above table)
- Press the number to toggle the setting
Keyswitch and Tamper Setting
52
KEYSET
Keyswitch setting
Zone 1 ON mean enable
keyswitch
X
X
X
X
X
X
X
X
X
X
X
X
Zone 2 ON mean the keyswitch is
Momentary else Latch Remote
Control
Zone 3 ON mean keyswitch is NC
type else NO type
Zone 4 ON mean enable
keyswitch Siren toot else Strobe
Light blink
(Toot once/Blink 3 sec: ARM;
Toot twice/Blink 8 sec: DISARM)
53
TAMPER
Tamper Setting
Zone 1 ON mean enable Tamper
X
X
X
X
X
X
X
X
X
X
X
X
X
Zone 2 ON mean Tamper
activated 24 hours else activate
during Arm
Zone 3 ON mean Tamper is NC
type else NO
Remark : Keyswitch and Tamper Setting’sTable (Refer above table)
- Press the number to toggle the setting
Programmable Output Setting
54
OC1
OC1 setting
Zone 1 ON mean enable OC1
X
X
X
X
X
X
X
X
X
X
Zone 2 ON mean enable OC1
with latch high output
X
X
X
X
X
X
X
X
X
X
Zone 3 ON mean enable OC1
with latch low output
X
X
X
X
X
X
X
X
X
X
Zone 4 ON mean enable OC1
with momentary high output
X
X
X
X
X
X
X
X
X
X
Zone 5 ON mean enable OC1
with momentary low output
X
X
X
X
X
X
X
X
X
X
Zone 6 ON mean OC1 activated in
alarm mode else arm & disarm
mode
X
X
X
X
X
X
X
X
X
X
(Zone 2 to zone 5 will toggle)
X
X
X
X
X
X
X
X
X
X
55
OC2
OC2 setting
Zone 1 ON mean enable OC2
X
X
X
X
X
X
X
X
X
X
Zone 2 ON mean enable OC2
with latch high output
X
X
X
X
X
X
X
X
X
X
Zone 3 ON mean enable OC2
with latch low output
X
X
X
X
X
X
X
X
X
X
Zone 4 ON mean enable OC2
with momentary high output
X
X
X
X
X
X
X
X
X
X
Zone 5 ON mean enable OC2
with momentary low output
X
X
X
X
X
X
X
X
X
X
Zone 6 ON mean OC2 activated in
alarm mode else arm & disarm
mode
X
X
X
X
X
X
X
X
X
X
(Zone 2 to zone 5 will toggle)
X
X
X
X
X
X
X
X
X
X
7

T Sense Keypad Quick User & Installer Manual Rev 2.0
56
OC3
OC3 setting
Zone 1 ON mean enable OC3
X
X
X
X
X
X
X
X
X
X
Zone 2 ON mean enable OC3
with latch high output
X
X
X
X
X
X
X
X
X
X
Zone 3 ON mean enable OC3
with latch low output
X
X
X
X
X
X
X
X
X
X
Zone 4 ON mean enable OC3
with momentary high output
X
X
X
X
X
X
X
X
X
X
Zone 5 ON mean enable OC3
with momentary low output
X
X
X
X
X
X
X
X
X
X
Zone 6 ON mean OC3 activated in
alarm mode else arm & disarm
mode
X
X
X
X
X
X
X
X
X
X
(Zone 2 to zone 5 will toggle)
X
X
X
X
X
X
X
X
X
X
57
OC4
OC4 setting
Zone 1 ON mean enable OC4
X
X
X
X
X
X
X
X
X
X
Zone 2 ON mean enable OC4
with latch high output
X
X
X
X
X
X
X
X
X
X
Zone 3 ON mean enable OC4
with latch low output
X
X
X
X
X
X
X
X
X
X
Zone 4 ON mean enable OC4
with momentary high output
X
X
X
X
X
X
X
X
X
X
Zone 5 ON mean enable OC4
with momentary low output
X
X
X
X
X
X
X
X
X
X
Zone 6 ON mean OC4 activated in
alarm mode else arm & disarm
mode
X
X
X
X
X
X
X
X
X
X
(Zone 2 to zone 5 will toggle)
X
X
X
X
X
X
X
X
X
X
Home Automation Setting
64
ET ZN1
Event Trigger
Zone Group 1
Zone LED ON mean the zone is
will turn on Event Trigger Output
when violated
65
ET IO1
Event Trigger
Output Group 1
Zone LED ON mean enable IO
point
66
ET ZN2
Event Trigger
Zone Group 2
Zone LED ON mean the zone is
will turn on Event Trigger Output
when violated
67
ET IO2
Event Trigger
Output Group 2
Zone LED ON mean enable IO
point
Remark : Home Automation Setting’s (Refer above table)
- Press the corresponding number to select the output to be activated (Toggle based)
System Security
70
LOCK C
Keypad Lock
Counter
From 1 to 255 times of password
error before keypad lock
010#
71
LOCK T
Keypad Lock Time
From 0 to 255 minutes
003#
72
INS CD
Change installer
code
5 digits installer code
12345#
8
DAIKIN ELECTRONIC DEVICES MALAYSIA SDN BHD
Table of contents
Popular Security System manuals by other brands

Pilz
Pilz SDD ES PROFIBUS operating manual

Aritech
Aritech Attender 50 owner's manual

Lorex
Lorex SG17L7584 instruction manual

Precision Digital Corporation
Precision Digital Corporation Vigilante II PD154 instruction manual

Kentix
Kentix MultiSensor-LAN user manual

Fortress Automotive Security
Fortress Automotive Security FS-60 Installation handbook