manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Danfoss
  6. •
  7. Control Unit
  8. •
  9. Danfoss FH-WC User manual

Danfoss FH-WC User manual

This manual suits for next models

1

Other Danfoss Control Unit manuals

Danfoss PVG 32 Manual

Danfoss

Danfoss PVG 32 Manual

Danfoss ASV-PV User manual

Danfoss

Danfoss ASV-PV User manual

Danfoss MSV-C User manual

Danfoss

Danfoss MSV-C User manual

Danfoss MCO 101 User manual

Danfoss

Danfoss MCO 101 User manual

Danfoss VLT Ea4 User manual

Danfoss

Danfoss VLT Ea4 User manual

Danfoss JIP-WW User manual

Danfoss

Danfoss JIP-WW User manual

Danfoss ASV-PV DN 15 User manual

Danfoss

Danfoss ASV-PV DN 15 User manual

Danfoss PVG 120 User manual

Danfoss

Danfoss PVG 120 User manual

Danfoss EKF Series User manual

Danfoss

Danfoss EKF Series User manual

Danfoss PVG 100 Manual

Danfoss

Danfoss PVG 100 Manual

Danfoss AB-QM series User manual

Danfoss

Danfoss AB-QM series User manual

Danfoss ICSH 25 User manual

Danfoss

Danfoss ICSH 25 User manual

Danfoss AMZ 112 User manual

Danfoss

Danfoss AMZ 112 User manual

Danfoss ChangeOver6 User manual

Danfoss

Danfoss ChangeOver6 User manual

Danfoss EKE 1P User manual

Danfoss

Danfoss EKE 1P User manual

Danfoss MNF Series User manual

Danfoss

Danfoss MNF Series User manual

Danfoss EVR 2 User manual

Danfoss

Danfoss EVR 2 User manual

Danfoss VHX-DUO Installation instructions manual

Danfoss

Danfoss VHX-DUO Installation instructions manual

Danfoss Genesis Passive User manual

Danfoss

Danfoss Genesis Passive User manual

Danfoss PM 5-65 User manual

Danfoss

Danfoss PM 5-65 User manual

Danfoss EKC 102A User manual

Danfoss

Danfoss EKC 102A User manual

Danfoss Icon Master User guide

Danfoss

Danfoss Icon Master User guide

Danfoss KP 1 User manual

Danfoss

Danfoss KP 1 User manual

Danfoss ECL Comfort 210 User manual

Danfoss

Danfoss ECL Comfort 210 User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

MOTECK CB4M-S user guide

MOTECK

MOTECK CB4M-S user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
Specification FH-WC
Code number 088H012800
Hard-wired control box for
underfloor heating ●
Number of zone outputs for
thermal actuators 8
Maximum number of actuator
per zone 2
Zone outputs - voltage 230 Vac, 50 Hz
Zone outputs (2) -
max rating 3W
Night set-back channels (1) 2
Voltage free relay output for
interlocks 2 x SPST
Voltage rating of interlock relay 230 Vac, 50 Hz
Current rating of interlock relay 2 Amps, inductive
Power supply 230 Vac, 50 Hz
Max ambient temperature 50°C
Dimensions,mm 314w x 110h x 61d
(1) Night set-back requires separate time control
(2) Maximum 2 actuators per zone
FH-WC Hardwired Underfloor Heating Connection Box
Installation Instructions
System Schematic
Mounting
Mains in
Interlock
Interlock
ROOM THERMOSTATS
FH-WC WIRING BOX
MANIFOLD
THERMAL
ACTUATORS
Zone 1
Zone 2
Zone 3
Cable Access: Thermostats, Interlock and Mains
FH-WC Hard Wired Box
Cable Access: Thermal Actuators
2
Wiring Connections
System 1: basic system without time control
System 2: system with programmable
roomthermostats System 3: system with 2 channel centralised
night set-back
Replacing Wiring Box Cover
Danfoss Randall can accept no responsibilty for possible errors in catalogues, brochures and other printed material. Danfoss Randall reserves the right to alter its products
without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications
already agreed.
Danfoss Randall Limited,
AmpthillRoad,
Bedford, MK42 9ER
Telephone: (01234) 364621 Fax: (01234) 219705
Email: [email protected]
Website: www.danfoss-randall.co.uk
Part No: 90091 Iss: 03 05/05