manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Danfoss
  6. •
  7. Controllers
  8. •
  9. Danfoss AK-UI55 User manual

Danfoss AK-UI55 User manual

Other Danfoss Controllers manuals

Danfoss AME 110 NL User manual

Danfoss

Danfoss AME 110 NL User manual

Danfoss Optyma Plus User manual

Danfoss

Danfoss Optyma Plus User manual

Danfoss DEVIreg Multi User manual

Danfoss

Danfoss DEVIreg Multi User manual

Danfoss AME 410 User manual

Danfoss

Danfoss AME 410 User manual

Danfoss VLT AutomationDrive FC 302 User manual

Danfoss

Danfoss VLT AutomationDrive FC 302 User manual

Danfoss PVE 4 Series Manual

Danfoss

Danfoss PVE 4 Series Manual

Danfoss AME 110 User manual

Danfoss

Danfoss AME 110 User manual

Danfoss EKC 326A User manual

Danfoss

Danfoss EKC 326A User manual

Danfoss MCD 201 Guide

Danfoss

Danfoss MCD 201 Guide

Danfoss Icon Series User manual

Danfoss

Danfoss Icon Series User manual

Danfoss AME 130H User manual

Danfoss

Danfoss AME 130H User manual

Danfoss VLT MCD 200 User manual

Danfoss

Danfoss VLT MCD 200 User manual

Danfoss AMV 335 User manual

Danfoss

Danfoss AMV 335 User manual

Danfoss ADAP-KOOL AK-PC 572 User manual

Danfoss

Danfoss ADAP-KOOL AK-PC 572 User manual

Danfoss 51 Series User manual

Danfoss

Danfoss 51 Series User manual

Danfoss AFP 2/VFG 22 (221) User manual

Danfoss

Danfoss AFP 2/VFG 22 (221) User manual

Danfoss AK-CC 450 User manual

Danfoss

Danfoss AK-CC 450 User manual

Danfoss AME 35 User manual

Danfoss

Danfoss AME 35 User manual

Danfoss VLT AQUA Drive FC 202 User manual

Danfoss

Danfoss VLT AQUA Drive FC 202 User manual

Danfoss ESBE 90 Series User manual

Danfoss

Danfoss ESBE 90 Series User manual

Danfoss PCVA User manual

Danfoss

Danfoss PCVA User manual

Danfoss OBC 80 Series User manual

Danfoss

Danfoss OBC 80 Series User manual

Danfoss VLT AutomationDrive FC 300 User manual

Danfoss

Danfoss VLT AutomationDrive FC 300 User manual

Danfoss pved-cl Manual

Danfoss

Danfoss pved-cl Manual

Popular Controllers manuals by other brands

Sunricher SR-ZV9003T3-RGBW-US Installation

Sunricher

Sunricher SR-ZV9003T3-RGBW-US Installation

Ksenia intro Installation and configuration manual

Ksenia

Ksenia intro Installation and configuration manual

Inovance CAN200 Series manual

Inovance

Inovance CAN200 Series manual

Gauzy LC6 FLEX Controller Installation and operation guide

Gauzy

Gauzy LC6 FLEX Controller Installation and operation guide

Viking SLP-1 Technical practice

Viking

Viking SLP-1 Technical practice

CKD KBX-30E-U Series instruction manual

CKD

CKD KBX-30E-U Series instruction manual

Sharp Energy Sun Flux User manual & installation guide

Sharp Energy

Sharp Energy Sun Flux User manual & installation guide

Yamaha RCX40 user manual

Yamaha

Yamaha RCX40 user manual

AB Quality PowerFlex 400 Frames D-H Service bulletin

AB Quality

AB Quality PowerFlex 400 Frames D-H Service bulletin

Yamaha MJC8 owner's manual

Yamaha

Yamaha MJC8 owner's manual

AL-KO ATC operating instructions

AL-KO

AL-KO ATC operating instructions

Savant SmartControl 2 Deployment guide

Savant

Savant SmartControl 2 Deployment guide

GameSir T3S user manual

GameSir

GameSir T3S user manual

Kostal inveor operating manual

Kostal

Kostal inveor operating manual

Emerson Yarway 20-55 Operating and safety instructions

Emerson

Emerson Yarway 20-55 Operating and safety instructions

CoCo ACM-LV24 Quick installation guide

CoCo

CoCo ACM-LV24 Quick installation guide

Brooks SLA5810/20 Installation and operation manual

Brooks

Brooks SLA5810/20 Installation and operation manual

SIGMA TEK SR 011 Technical manual

SIGMA TEK

SIGMA TEK SR 011 Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

084R8057
AN294434115977en-000202
Identification Dimensions
Mounting
Connection
AK-UI cable, 3 m: 084B4078
AK-UI cable, 6 m: 084B4079
RJ 12
AK-UI55 Set
tamb = 0 – 55 °C
32 – 130 °F
Non condensing
L max.= 100 m
NEMA4
IP65
0.5 - 3.0 mm
L1+ L2 : max.= 100 m
L1
L2
AK-UI55 Bluetooth
AK-UI55 Info
Installation Guide
AK-UI55
© Danfoss | DCS (vt) | 2019.09 AN294434115977en-000202b| 1
AK-UI55 Info
AK-UI55 Bluetooth
Functions:
See the respective controller's User Guide.
Lights up in event of:
Energy optimization
Cooling
Defrosting
Fan operation
Lights up in event of:
Alarm
The display can give the following messages:
-d- Defrost is in progress
Err The temperature cannot be displayed due to a sensor error
Fan Appliance cleaning has been initiated. The fans are running
OFF Appliance cleaning is activated and the appliance can be cleaned
OFF The main switch is set to Off
SEr The main switch is set to service / manual operation
CO Flashes: Will display in event of a refrigerant leakage alarm, but only if the refrigerant is set up for CO
With start-up /connection to a controller,
the display will“light up in circles”as it col-
lects data from the controller.
Without configuration, the display
can show the same information as
shown above.
Loc
The operation is locked and cannot
be operated via Bluetooth.
Unlock from the system device.
Access to parameters via Bluetooth and app
1. App can be downloaded from Google App Store and Google Play
Name = AK-CC55 Connect
Start the app.
2. Click on the display’s Bluetooth button for 3 seconds.
The Bluetooth light will then flash while display is showing the
controller’s address.
3. Connect to the controller from the app.
© Danfoss | DCS (vt) | 2019.09
2 | AN294434115977en-000202b
ADAP-KOOL®
AK-UI55 Set
Display during operation
The values will be shown with three digits, and with a setting you can display the temperature in °C or in °F.
Lights in event of alarm — press on alarm button — alarm relay is reset — alarm code displayed — e.g.“A1”
Lights up in event of:
Energy optimization
Cooling
Defrosting
Fan operation Up arrow / Down arrow / Arrow to left:
Navigation in the menu and setting of values.
Long press (3 seconds) will start a defrost,
“dEF” is shown in the display.
Long press (3 seconds) gives access to the
information menu “InF”
SET:
Long press (3 seconds) gives access to the“SEt”menu.
If the operation is locked with a password,“PS” is shown. Enter the code.
Shows the setting for a chosen parameter / saves a changed setting.
Short press gives access to entering of the thermostat’s cut-out limit.
Alarm Codes:
See the respective controller's User Guide.
The display can give the following messages:
-d- Defrost is in progress
Err The temperature cannot be displayed due to a sensor error
Err The display cannot load data from the controller. Disconnect and then reconnect the display
ALA The alarm button is activated. The first alarm code is then shown
- - - Top position in the alarm queue
- - - Bottom position in the alarm queue
Loc The configuration is locked. Unlock by pressing (for 3 seconds) on the‘up arrow’ and ‘down arrow’ simultaneously
UnL The configuration is unlocked
- - - The parameter has reached min. or max. limit
PS A password is required for access to the menu
Fan Appliance cleaning has been initiated. The fans are running
OFF Appliance cleaning is activated and the appliance can now be cleaned
OFF The main switch is set to Off
SEr The main switch is set to service / manual operation
CO Flashes: Will display in event of a refrigerant leakage alarm, but only if the refrigerant is set up for CO
Factory setting
If you need to return to the factoryset values it can be done in this way:
- Cut off the supply voltage to the controller
- Keep up "∧" and down "∨"arrow buttons depressed at the same time as you reconnect the supply voltage
- When FAc is shown in the display select "yes"
© Danfoss | DCS (vt) | 2019.09 AN294434115977en-000202b| 3
ADAP-KOOL®
Statements for the AK-UI55 Bluetooth display:
FCC COMPLIANCE STATEMENT
CAUTION: Changes or modifications not expressly approved could void your authority to use this equipment
This device complies with Part 15 of the FCC Rules. Operation to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation
INDUSTRY CANADA STATEMENT
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device
may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the
device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux
deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
NOTICE
FCC COMPLIANT NOTICE
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
Modifications: Any modifications made to this device that are not approved by Danfoss may void the authority granted to the user by the FCC to
operate this equipment.
Any regulatory related concerns contact: [email protected]
Danfoss Cooling
11655 Crossroads Circle
Baltimore, Maryland 21220
United States of America
www.danfoss.com
EU CONFORMITY NOTICE
Hereby, Danfoss A/S declares that the radio equipment type AK-UI55 Bluetooth is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address: www.danfoss.com
Danfoss A/S
Nordborgvej 81
6430 Nordborg
Denmark
www.danfoss.com
© Danfoss | DCS (vt) | 2019.09 AN294434115977en-000202b| 4