manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Danfoss
  6. •
  7. Water Filtration System
  8. •
  9. Danfoss 130B2404 Instruction sheet

Danfoss 130B2404 Instruction sheet

Sketches / Skizzen
Footprints / Befestigungsmaße
MI.90.N1.5B - VLT®is a registered Danfoss trademark
Sine-wave Filter MCC 101 -Technical data /Technische Daten
Nom.
current
(50/60/120
Hz)
Nenn-
strom
(50/60/100
Hz)
Motor
Power
(400V)
Motor-
leistung
(400V)
Foot-
print
Gehäuse
Protect.
degree
Schutz-
art
Code
number
Bestell-
nummer
Dimensions
Maße
Max. wire
cross
section
Max.
Anschl.
Quersch.
[A] [kW] A a B b C c d e f [mm2]
2.5/2.5/2 0.37-0.75 A1 IP00
IP20
130B2404
130B2439
200 190 75 60 205 7 8 4.5 5 4
4.5/4/3.5 1.1 – 1.5 A1 IP00
IP20
130B2406
130B2441
200 190 75 60 205 7 8 4.5 5 4
8/7.5/5.5 2.2 – 3.0 A2 IP00
IP20
130B2408
130B2443
268 257 90 70 206 8 11 6.5 6.5 4
10/9.5/7.5 4.0 A2 IP00
IP20
130B2409
130B2444
268 257 90
98
70 206 8 11 6.5 6.5 4
17/16/13 5.5 – 7.5 A3 IP00
IP20
130B2411
130B2446
268 257 130
138
90 205 8 11 6.5 6.5 4
Note: The minimum switching frequency for MCC 101 filters up to 16 A is 5 kHz.
Anmerkung: Die minimale Taktfrequenz für MCC 101 Filter bis 16 A ist 5 kHz.
IP00 IP20
Warnings / Warnung
– When in use the filter surface temperature rises. DO NOT touch the filter during operation.
– Never work on a filter in operation. Touching the electrical parts may be fatal – even after the
equipment has been disconnected from the drive or motor.
– Before servicing the filter, wait at least the voltage discharge time stated in the Design Guide
for the corresponding VLT® to avoid electrical shock hazard
– Never attempt to repair a defective filter
– Während des Betriebs steigt die Oberflächentemperatur des Filter, also berühren Sie NICHT
den Filter während des Betriebs
– Arbeiten Sie niemals an einem Filter, der gerade in Betrieb ist. Das Berühren elektrischer
Teile - auch nach der Trennung des Gerätes vom Netz - kann lebensgefährlich sein.
– Warten Sie mindestens die im Projektierungshandbuch angegebene Entladezeit für den
entsprechenden VLT® ab, bevor Sie Wartungsarbeiten am Filter durchführen, um das Risiko
eines Stromschlags zu vermeiden.
– Versuchen Sie niemals, einen beschädigten Filter zu reparieren.
Necessary drive adjustments / Notwendige Umrichtereinstellungen
– The VLT switching frequency must be set to the value specified for the individual filter.
Please consult the VLT Programming Guide for the corresponding parameter values.
– With an output filter installed only a reduced Automatic Motor Adaption (AMA) can be used.
– The filters are designed for a max. frequency of 120 Hz. For frequencies above 50 Hz the
nominal current may have to be reduced (see filter nameplate).
– Die Schaltfrequenz des VLT muss auf den für den jeweiligen Filter angegebenen Wert
eingestellt werden. Siehe Beschreibung im Programmierhandbuch.
– Mit einem installierten Ausgangsfilter kann nur eine reduzierte Automatische
Motoranpassung (AMA) durchgeführt werden.
– Die Filter sind auf eine max. Frequenz von 120 Hz ausgelegt. Bei Betrieb über 50 Hz muß
der Filter Nennstrom ents
p
rechend reduziert werden
(
siehe Filter T
yp
enschild
)
.
MCC 101 - Sine Wave Filter
Installation guidelines
Installationsanweisungen
Mounting / Montage
– Mount the filter vertically with the output (motor side) at the bottom
– Do not mount the filter close to other heating elements or heat sensitive material (such as wood)
– Filter can be side-mounted with the frequency converter. There is no requirement for spacing
between the filter and frequency converter.
– Filter senkrecht und mit dem Filteranschluss (Motorseite) nach unten befestigen
– Nicht in der Nähe von temperaturempfindlichen Elementen montieren.
– Das Filter kann direkt neben dem Frequenzumrichter montiert werden. Es gibt keine
Einschränkungen bezüglich des Mindestabstands zwischen Frequenzumrichter und Filter.
Earthing / Erdung
The filter must be earthed before switching the power on (high leakage currents).
Common mode interferences are kept small by ensuring that the current return path to the VLT® has
the lowest possible impedance.
– Choose the best earthing possibility (e.g. cabinet mounting panel)
– Use the enclosed (in accessory bag) protective earth terminal to ensure the best possible earthing
– Remove any paint present to ensure good electrical contact
– Ensure that the filter and VLT® make solid electrical contact (high frequency earthing)
Die Gleichtaktstörungen werden klein gehalten, indem man dafür sorgt, dass die Ströme möglichst
niederimpedant zur Quelle zurückgeführt werden.
– Beste Erdungsmöglichkeit wählen (z.B. Montageplatte des Schaltschrankes)
– Grossflächiges Kontaktieren von Filter und Frequenzumrichter (HF-Erdung)
– Benutzen Sie die in mitgelieferte PE Klemme für eine optimale Erdung.
– Entfernen vorhandener Farbe, so dass eine gute Kontaktierung gewährleistet ist
– Das Filter ist unbedingt vor dem Einschalten zu erden (erhöhter Ableitstrom)
Screening / Schirmung
It is recommended to use screened cables to reduce the radiation of electromagnetic noise into the
environment and prevent malfunctions in the installation.
– Cable between the VLT® output (U, V, W) and filter input (U1, V1, W1) to be screened or twisted.
– Use preferably screened cables between the filter output (U2, V2, W2) and the motor. When
unscreened cables are employed it should be ensured that the installation minimizes the possibility
of cross-couplings with other cables carrying sensitive signals. This can be achieved by measures
such as cable segregation and mounting in earthed cable trays.
– The screen on screened cables must be solidly connected at both ends to the housings (e.g.
housing of filter and motor).
– All screen connections must exhibit the smallest possible impedance, i.e. solid, large area
connections, both ends of shielded cable.
– For maximum cable length consult the Design Guide of the VLT® in question
Es ist empfehlenswert auch bei Einsatz eines Ausgangsfilters das Motorkabel geschirmt auszuführen
um die Störabstrahlung an die Umgebung zu begrenzen und Anlagenstörungen vorzubeugen.
– Kabel zwischen Umrichterausgang (U, V, W) und Filtereingang (U1, V1, W1) möglichst geschirmt
oder verdrillt ausführen.
– Es ist vorzugsweise zwischen Filterausgang (U2, V2, W2) und Motor geschirmtes Kabel zu
verwenden. Sollte dies nicht vorgesehen sein, muss sichergestellt werden, dass die Installation
die Warscheinlichkeit von gegenseitigen Einkopplungen z.B. mit Signalkabeln ausschließt. Dies
kann u.a. durch eine gute räumliche Trennung und Verlegung der Kabel in geerdeten
Metallkanälen erreicht werden.
– Bei geschirmten Leitungen muss der Schirm beidseitig grossflächig mit den Gehäusen verbunden
werden (z.B. Filter- und Motorgehäuse).
– Alle Schirmverbindungen möglichst niederimpedant, sprich grossflächig auslegen (z.B. Schirm
unter den Befestigungsbolzen des Filters montieren).
– Die maximale Kabellänge ist dem Projektierungshandbuch des jeweiligen VLT® zu entnehmen.
Block diagram / Anschlussschema
VLT frequency
converter
Sine wave filter
MCO
MI.90.N1.5B - VLT®is a registered Danfoss trademark
Shielded or
twisted cable Screened
cable

This manual suits for next models

10

Other Danfoss Water Filtration System manuals

Danfoss AHF 010 Guide

Danfoss

Danfoss AHF 010 Guide

Danfoss VLT AAF00x User manual

Danfoss

Danfoss VLT AAF00x User manual

Danfoss AAF 007 Installation and operating manual

Danfoss

Danfoss AAF 007 Installation and operating manual

Danfoss VLT AAF006 User manual

Danfoss

Danfoss VLT AAF006 User manual

Danfoss VLT AHF 005 User manual

Danfoss

Danfoss VLT AHF 005 User manual

Danfoss OF7S1 User manual

Danfoss

Danfoss OF7S1 User manual

Danfoss VLT AAF006 User manual

Danfoss

Danfoss VLT AAF006 User manual

Danfoss VLT AHF 005 User manual

Danfoss

Danfoss VLT AHF 005 User manual

Danfoss IPS 8 User manual

Danfoss

Danfoss IPS 8 User manual

Danfoss AHF 005 User manual

Danfoss

Danfoss AHF 005 User manual

Danfoss VLT AAF00x User manual

Danfoss

Danfoss VLT AAF00x User manual

Danfoss VLT AHF 005 Guide

Danfoss

Danfoss VLT AHF 005 Guide

Danfoss AHF 005 User manual

Danfoss

Danfoss AHF 005 User manual

Danfoss VLT AHF005 Guide

Danfoss

Danfoss VLT AHF005 Guide

Danfoss VLT AHF 005 User manual

Danfoss

Danfoss VLT AHF 005 User manual

Popular Water Filtration System manuals by other brands

InSinkErator F-201 Specifications

InSinkErator

InSinkErator F-201 Specifications

Pentair Autotrol 255 Logix 740-760 Installer manual

Pentair

Pentair Autotrol 255 Logix 740-760 Installer manual

EHEIM aqua160 Original operating manual

EHEIM

EHEIM aqua160 Original operating manual

Weh TSF2 H2 operating instructions

Weh

Weh TSF2 H2 operating instructions

Greenway Home Products Dual Stage Water Filtration System VGS2-PC Use and care guide

Greenway Home Products

Greenway Home Products Dual Stage Water Filtration System VGS2-PC Use and care guide

Grunbeck desaliQ Operation manual

Grunbeck

Grunbeck desaliQ Operation manual

ELECTOR Clarimax user guide

ELECTOR

ELECTOR Clarimax user guide

Zip Heater HydroTap G4 user guide

Zip Heater

Zip Heater HydroTap G4 user guide

Hague Quality Water WaterMax H6000 Owner's manual and installation guide

Hague Quality Water

Hague Quality Water WaterMax H6000 Owner's manual and installation guide

Filtech DP 200 Use and maintenance manual

Filtech

Filtech DP 200 Use and maintenance manual

Wilo EMUport CORE Series Installation and operating instructions

Wilo

Wilo EMUport CORE Series Installation and operating instructions

HYDAC FILTER SYSTEMS OLF-5 Series Installation and maintenance instructions

HYDAC FILTER SYSTEMS

HYDAC FILTER SYSTEMS OLF-5 Series Installation and maintenance instructions

WilTec ECF-15000 instruction manual

WilTec

WilTec ECF-15000 instruction manual

Hycontrol HYVENT Installation and operation manual

Hycontrol

Hycontrol HYVENT Installation and operation manual

Intex 126644GS owner's manual

Intex

Intex 126644GS owner's manual

Axeon ELP Series user manual

Axeon

Axeon ELP Series user manual

Wellness Wellness Shower Usage & Care Guide

Wellness

Wellness Wellness Shower Usage & Care Guide

Atlantic Ultraviolet Eco-Logic Operation manual

Atlantic Ultraviolet

Atlantic Ultraviolet Eco-Logic Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.