TYPICAL WIRING DIAGRAM
NOTE: Larger versions of the Typical Wiring Diagrams are available in the products’
operator manuals, refer to DSE Publication: 057-310 DSE8910 Operator Manual & 057-311
DSE8920 Operator Manual, both available from www.deepseaelectronics.com.
Deep Sea Electronics Ltd.
Tel:+44 (0)1723 890099
Email: support@deepseaelectronics.com
Web: www.deepseaelectronics.com
Deep Sea Electronics Inc.
Tel: +1 (815) 316 8706
Email: USAsupport@deepseaelectronics.com
Web: www.deepseaelectronics.com
DEEP SEA ELECTRONICS
DSE8910 & DSE8920 Installation Instructions
053-248
ISSUE: 1
ACCESSING THE RUNNING CONFIGURATION EDITOR
•The Running Configuration Editor is accessible without stopping the generator. All protections
remain active whilst the ‘Running Configuration Editor is accessed.
•Press and hold the Tick button to enter the Running Configuration Editor.
EDITING A PARAMETER
•Enter the Running Configuration Editor as described above.
•Press the Up or Down buttons to select the section to view/change. The current selected
section highlights in green.
•Press the Left or Right buttons to select the Subsection/Parameter to be edited. The
current selected item highlights in green.
•To edit the parameter, press the Tick button to enter the edit mode. The parameter is no
longer highlighted green to indicate editing.
•Press the Up or Down buttons to change the parameter to the required value.
•Press the Tick button to save the value. The parameter highlights green to indicate that it has
been saved.
•To exit the editor and save the changes, press and hold the Tick button.
SELECTING THE DSE8910 OR DSE8920 SOFTWARE APPLICATION
•Ensure the generator is at rest and the module by pressing the Stop/Reset Mode button.
•Enter the Running Configuration Editor as described above.
•Press the Up or Down buttons to navigate to the MODEL TYPE section. The section
highlights in green when selected.
•Press the Right button to select the MODEL SELECTION parameter. The parameter
highlights in green when selected.
•To edit the parameter, press the Tick button to enter the edit mode. The parameter is no
longer highlighted green to indicate editing.
•Press the Up or Down buttons to change between DSE8910 and DSE8920, by default
DSE8920 is selected.
•Press the Tick button to change the software application, a confirmation box appears.
•Press the Left or Right buttons to select YES to confirm software application change.
When prompted, remove the power supply to the module and then reapply the power supply. The
module powers up in the newly selected software application.
NOTE: If the editor is left inactive for the duration of the LCD Page Timer, it is automatically
exited to ensure security.
RUNNING CONFIGURATION EDITOR
Section
Sub Section
Parameter
Value
Model Type
Model Selection
8910 / 8920
Display
Backlight
Backlight Level
10 % to 100 %
Language
Lang File Selection
Run Load
Priority
Load Priority
1 to 32
Screen
Selection
Home Selection
8910: Home / Engine / Generator /
Bus / I/O / PLC / Status
8920: Home / Engine / Generator /
Mains / I/O / PLC / Status
Commissioning Screen
Enable / Disable
Tier 4 Screen
Enable / Disable
Display Options
Page Timer
1 s to 1 H
Graphics
Bars / Meters
Bar Selection
DEF Level / Coolant Temp
Options
Starting Alarms
Enable / Disable
Mains Decoupling Test
Mode
Enable / Disable
External Alarm Alert
Enable / Disable
Adjustments
Frequency Adjust
0 % to 100 %
Voltage Adjust
0 % to 100 %
Units
Pressure
kPa / Bar / PSI
Temperature
°C / °F
Volume
Litres / Imp Gal / US Gal
Logging
Safe Removal
Do Not Remove / Safe to Remove
/ Not Detected / Unknown
Maintenance Reset
Maintenance Alarm 1, 2 & 3
Reset / Not Reset
Engine
Governor Gain
0.0 % to 15.9 %
Frequency Adjust Offset
-8.0 % to 7.9 %
DPF Auto Inhibit
Enable / Disable
DPF Manual Regen
Enable / Disable
Power
Levels
Control Mode
Power Control Mode
Const Power / Frequency Power /
Voltage Power
kVAr Control Mode
Const Reactive / Voltage-Reactive
Power / Power-Power Factor
Mains
Mains Stability Timer
0 s to 10 s
Out of Sync
Enable / Disable
Sequence Alarm Reset
Enable / Disable
DIMENSIONS AND MOUNTING
Parameter
Specification
Dimensions
310 mm X 162 mm X 51.3 mm (12.2 ” X 6.38 ” X 2.02 ”)
Panel Cutout
282 mm X 136 mm (11.10” X 5.35”)
Weight
1.19 kg (2.62 lb)
Operating Temperature
-40 ºC to +70 ºC (-40 ºF to +158 ºF)
Storage Temperature
-40 ºC to +80 ºC (-40 ºF to +176 ºF)
PANEL FASCIA FIXING CLIPS
NOTE: In conditions of excessive vibration, mount the module on suitable anti-vibration
mountings.
The module is held into the panel fascia using the supplied fixing clips:
•Withdraw the fixing clip screw (turn anticlockwise) until only the pointed end is protruding from the
clip.
•Insert the three ‘prongs’ of the fixing clip into the slots in the side of the module case.
•Pull the fixing clip backwards (towards the back of the module) ensuring all three prongs of the clip
are inside their allotted slots.
•Turn the fixing clip screws clockwise until they make contact with the panel fascia.
•Turn the screw a quarter of a turn to secure the module into the panel fascia. Care must be taken
not to over tighten the fixing clip screws.
REQUIREMENTS FOR UL CERTIFICATION
WARNING!: More than one live circuit exists, see diagram overleaf for further information.
ATTENTION!: Il existe plusieurs circuits sous tension. Voir le schéma au verso pour plus
d'informations.
Specification
Description
Screw Terminal Tightening
Torque
•4.5 lb-in (0.5 Nm)
Conductors
•Terminals suitable for connection of conductor size 13 AWG to 20
AWG (0.5 mm² to 2.5 mm²).
•Conductor protection must be provided in accordance with NFPA 70,
Article 240
•Low voltage circuits (35 V or less) must be supplied from the engine
starting battery or an isolated secondary circuit.
•The communication, sensor, and/or battery derived circuit
conductors shall be separated and secured to maintain at least ¼ ”
(6 mm) separation from the generator and mains connected circuit
conductors unless all conductors are rated 600 V or greater.
Current Inputs
•Must be connected through UL Listed or Recognized isolating
current transformers with the secondary rating of 5 A max.
Communication Circuits
•Must be connected to communication circuits of UL Listed equipment
DC Output Pilot Duty
•0.5 A
Mounting
•Suitable for flat surface mounting in Type 1 Enclosure Type rating
with surrounding air temperature -22 ºF to +122 ºF (-30 ºC to +50 ºC)
•Suitable for pollution degree 3 environments when voltage sensing
inputs do not exceed 300 V. When used to monitor voltages over
300 V device to be installed in an unventilated or filtered ventilation
enclosure to maintain a pollution degree 2 environment.
Operating Temperature
•-22 ºF to +122 ºF (-30 ºC to +50 ºC)

This manual suits for next models

1

Other DEEP SEA ELECTRONICS Control Unit manuals

DEEP SEA ELECTRONICS DSEControl DSEE050 User manual

DEEP SEA ELECTRONICS

DEEP SEA ELECTRONICS DSEControl DSEE050 User manual

DEEP SEA ELECTRONICS DSEGenset DSE3110 User manual

DEEP SEA ELECTRONICS

DEEP SEA ELECTRONICS DSEGenset DSE3110 User manual

DEEP SEA ELECTRONICS DSEGenset DSE6110 MKIII User manual

DEEP SEA ELECTRONICS

DEEP SEA ELECTRONICS DSEGenset DSE6110 MKIII User manual

DEEP SEA ELECTRONICS DSEE800 User manual

DEEP SEA ELECTRONICS

DEEP SEA ELECTRONICS DSEE800 User manual

DEEP SEA ELECTRONICS 6110 User manual

DEEP SEA ELECTRONICS

DEEP SEA ELECTRONICS 6110 User manual

DEEP SEA ELECTRONICS DSE8910 User manual

DEEP SEA ELECTRONICS

DEEP SEA ELECTRONICS DSE8910 User manual

DEEP SEA ELECTRONICS DSECONTROL DSE7000 Series User manual

DEEP SEA ELECTRONICS

DEEP SEA ELECTRONICS DSECONTROL DSE7000 Series User manual

Popular Control Unit manuals by other brands

Nakanishi E800Z Operation manual

Nakanishi

Nakanishi E800Z Operation manual

Danfoss ETS 250 installation guide

Danfoss

Danfoss ETS 250 installation guide

Kathrein UFOcompact plus UFG 810 manual

Kathrein

Kathrein UFOcompact plus UFG 810 manual

Chamberlain 041-0200-000 instructions

Chamberlain

Chamberlain 041-0200-000 instructions

Vantron MOB-WBT-56 user manual

Vantron

Vantron MOB-WBT-56 user manual

ABB 616016-T2 Replacement procedure

ABB

ABB 616016-T2 Replacement procedure

Listen Technologies ListenPoint quick reference

Listen Technologies

Listen Technologies ListenPoint quick reference

Ebyte E32-DTU-V8 manual

Ebyte

Ebyte E32-DTU-V8 manual

Stahl 8146/5 Series operating instructions

Stahl

Stahl 8146/5 Series operating instructions

schmersal SRB 202CS/T operating instructions

schmersal

schmersal SRB 202CS/T operating instructions

Becker Centronic UnitControl UC520 Assembly and operating instructions

Becker

Becker Centronic UnitControl UC520 Assembly and operating instructions

Burkert 6213 EV operating instructions

Burkert

Burkert 6213 EV operating instructions

HP A12500 Product End-of-Life Disassembly Instructions

HP

HP A12500 Product End-of-Life Disassembly Instructions

Swidget WI002UWA quick start guide

Swidget

Swidget WI002UWA quick start guide

Parker B5 operating instructions

Parker

Parker B5 operating instructions

Allen-Bradley MicroLogix 1500 1764-MM1 installation instructions

Allen-Bradley

Allen-Bradley MicroLogix 1500 1764-MM1 installation instructions

VAT 110 Series Installation, operating,  & maintenance instructions

VAT

VAT 110 Series Installation, operating, & maintenance instructions

Jorc SmartGuard Installation & maintenance instructions

Jorc

Jorc SmartGuard Installation & maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.