SAFETY
Propane Gas: Propane gas is odorless. An
odor-making agent is added to propane gas.
The odor helps you detect a propane gas
leak. However, the odor added to propane
gas may fade. Propane gas may be present
even though no odor exists.
Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this heater.
1. Install and use heater with care. Follow all
local ordinances and codes. In the absence
of local ordinances and codes, refer to
the Standard for Storage and Handling of
Liqueed Petroleum Gas, ANSI/NFPA 58
Natural Gas Installation Code, CAN/CGA
B149.2. This instructs on the safe storage
and handling of propane gases.
2. State of Massachusetts: The installation
must be made by a licensed plumber or
gas tter in the Commonwealth of Mas-
sachusetts.
3. Use only propane gas set up for vapor
withdrawal.
4. Provide adequate ventilation. Before us-
ing heater, provide at least a 2.5 square
foot (0.232 m2) (80,000 Btu/Hr heaters) or
6.0 square foot (0.557 m2) (200,000 Btu/
Hr heaters) opening of fresh, outside air.
5. For indoor use only. Do not use heater
outdoors.
6. Keep heater away from strong drafts,
wind, water spray, rain or dripping water.
7. Do not use heater in occupied dwellings
or in living or sleeping quarters.
8. Do not use heater in a basement or below
ground level. Propane gas is heavier than
air. If a leak occurs, propane gas may sink
to the lowest possible level.
9. Keep appliance area clear and free from
combustible materials, gasoline, paint
thinner and other ammable vapors and
liquids. Dust is combust ble. Do not use
heater in areas with high dust content.
10. Minimum heater clearances from combus-
tibles: 80,000 Btu/Hr heaters
Sides: 3 feet (91 cm); Top: 6 feet (1.83 m)
100-200,000 Btu/Hr heaters
Sides: 3 feet (91 cm); Top: 7 feet (2.1 m)
11. Keep heater at least six feet (1.83 m) from
propane tank(s).
12. Keep propane tank(s) below 100° F
(37.8° C).
WARNING: This product
contains and/or generates
chemicals known to the State
of California to cause cancer or
birth defects or other reproduc-
tive harm.
WARNING: Fire, burn inhala-
tion and explosion hazard. Keep
solidcombustibles,suchasbuild-
ingmaterials,paperorcardboard,
a safe distance away from the
heater as recommended by the
instructions.Neveruse theheater
inspaceswhichdoormaycontain
volatile or airborne combustibles
orproducts suchasgasoline, sol-
vents,paintthinner,dustparticles
or unknown chemicals.
WARNING: Not for home or
recreational vehicle use.
The heater is designed for use as a con-
struction heater in accordance with ANSI
Z83.7•CGA 2.14. Other standards govern
the use of fuel gases and heating products
for specic uses. Your local authority can
advise you about these. The primary purpose
of construction heaters is to provide tempo-
rary heating of buildings under construction,
alteration or repair. Properly used, the heater
provides safe economical heating. Products
of combustion are vented into the area being
heated.
We cannot foresee every use which may be
made of our heaters. CHECK WITH YOUR
LOCAL FIRE SAFETY AUTHORITY IF YOU
HAVE QUESTIONS ABOUT HEATER USE.
Carbon Monoxide Poisoning: Some people
are more affected by carbon monoxide than
others. Early signs of carbon monoxide poi-
soning resemble the u, with headaches, diz-
ziness and/or nausea. If you have these signs,
the heater may not be working properly. Get
fresh air at once! Check for proper ventilation
and have heater serviced.