Thank you for purchasing DIG’s 410BT Single Station Battery Operated Timer. This
manual describes how to get the 410BT series timer up and running quickly. After
reading this manual and becoming familiar with the basic functionality of the timer,
use the manual as a reference for less common tasks in the future.
About the 410BT-MVA Battery Operated Timer
The 410BT series watering controller employs the latest in Bluetooth technology
using the free DIG BTT app for Android or iPhone. The 410BT is available as a single
station battery operated timer and is powered by two AA batteries that can last up
to 1 year using name brand alkaline batteries. The timer is enclosed in a compact,
waterproof housing to protect it from the elements.
Specification
• Operating pressure: 10 to 120 PSI (.7 to 8.3 bar)
• Temperature range: 38º-130º F (-2º to 54º C)
• Flow range: .1 to 6 GPM (.38 to 30 L/H)
• Power source: 2 AA alkaline batteries (not included)
• USA Connection: Female hose thread inlet (FHT) x male hose thread outlet (MHT)
• International Connection: British standard thread for tap (BSP)
• Dimensions: 5.5″x 3.1″x 4.3″
• Weight: 8 oz.
Component Identification
Controller
cover
DC Solenoid
1 button for
manual run
and reset
Battery compartment
cap for 2 AA batteries
12″Solenoid wire
FCC
Information
label

2
Installing Batteries
1. Open the battery compartment cap by turning it counter-clockwise.
2. Install two, fresh, brand name, AA alkaline batteries (not included) and note
the proper direction of the positive and negative orientation on the underside of
the timer.
3. Insert and screw the battery cap clockwise. Make sure to securely tighten the
cover rmly by hand only. The timer will now appear on the smartphone app and
is ready to be connected to and programmed.
Valve Adapter Installation
The 410BT series controller includes 3 adapters to retrot Rainbird, Hunter and Toro
valves. Follow the instructions below to install.
1. Shut off the main water supply
2. Remove the existing solenoid if applicable.
Note: If adapting to an IRRITROL valve, remove the solenoid but leave the existing solenoid
adapter installed.
3. Select the appropriate solenoid adapter associated with the valve. (see chart A)
4. Screw the solenoid adapter into the valve bonnet by hand, tighten with pliers if
necessary – but do not over tighten.
5. Thread the 410BT series solenoid into the valve adapter. Hand tighten only.
6. Turn the main water supply on and pressurize the valve; the valve may discharge
water momentarily but should then shut off.
7. Test the controller and the installation by pressing the button on the controller
or see section 6 on how to perform a manual run through the app. To turn the
valve on via the solenoid, lift the 410BT series controller from the solenoid and
turn the solenoid counter clockwise 1/2″to 3/4″of a turn, or until you hear or see
water owing through the valve. To turn the water off, turn the solenoid clockwise
1/2″to 3/4″of a turn and wait for the a few seconds for the valve to close.
8. Program the 410BT series controller (see section 7).
In-line valve Installation
Rated operating pressure: 10-125 PSI
Recommended Operating Pressure: 10-80 PSI
Warning: Wrap all ttings with Teon tape! Do not use pipe cement on valve as this
will damage the valve and void the warranty!
1. Shut off main water supply.
2. Install a 3/4 in. ball or gate valve onto the PVC pipe or to the valve manifold be-
fore installing the controller (Figure 1a and 1b).
3. Turn water supply on to ush the line and then shut the water off using the ball or
gate valve.
4. Wrap the male threads of the PVC adapters with 4-6 layers of Teon tape, then
tighten into the valve with a wrench.
5. Glue ttings to PVC main line and allow to dry.
6. Turn water supply on to pressurize the system. The controller will open momen-
tarily and then will shut off.
7. The unit is now ready to be programmed.

3
Controller
name
Last run
information
Battery life
Connection
strength
Schedule
Overview:
Shows current
program
run times.
Red lines
indicate that
there is an
overlapping
start time
Activate or
deactivate
the program
Schedule
type
Schedule
settings
Up to 5
start times.
Select an
existing
start time to
edit/delete.
Red start
times are
overlapping
and will not
run
Run time
for valve
Home
(current page)
Controller
settings
Manual run
Home Screen
Programming:
• Open the DIG BTT app and allow it to
scan for nearby timers.
Note: Connection range is up to 50 feet
(15 meters) line of sight.
• The new timer will appear on screen as
the DIG 410BT.
Note: If installing multiple timers, wait until
each unit is renamed until inserting the batteries.
• Select the timer to connect to it. The
following diagrams show all functionality.
Any changes made automatically save and
update to the controller instantaneously.
Programming
Initial Setup:
• Download the DIG BTT app using the iOS
App Store, Google Play,
or the QR code on the box.
• Remove the battery cap from the timer and
insert two fresh, brand name,
AA alkaline batteries (not included). The
proper orientation is denoted on the
underside of the timer.
• Screw the battery cap back on until
hand tight.
Picture of
controller
whether
controller is
currently
runnning
or not

4
Turn the
entire
system
on/off.
Controller
will not
water
Set a rain
delay
Set up to
9 dates
where the
controller
will prevent
watering
Budgeting
per month
View
monthly
watering
history for
the past 12
months Set name
of the
controller
Set picture
for the
controller
Set password for controller.
Password will only be seen when entering
controller from a new phone. Reset
controller to reset password if forgotten
Settings Screen

5
Start/Stop
Manual Run
Set Manual
Run
duration
Manual Run Screen
Reset to Factory Defaults
• Press and hold the button on the DIG BOHE-BT/BOHE-BTI for 15 seconds. This
will remove all controller programs, settings, historical information, and any set
passwords.
This is the only way to reset a password, so try not to forget it!
Technical Assistance
• Should you encounter any problem(s) with this product or if you do not
understand its many features, please refer to this operating manual rst

6
If further assistance is required, DIG offers the following customer support:
• DIGPRO Technical Service USA:
DIG’s Technical Service Team is available to answer questions in English and
Spanish from 8:00 AM to 5:00 PM (PST) Monday-Friday (except holidays)
at 1.800.344.2281 or 1.760.727.0914
• Questions also can be e-mailed to questions@digcorp.com
or faxed to 760.727.0282
• Specication documents and manuals are available for download at
www.digcorp.com
• Customer Assistance Outside the USA: Contact your local distributor
Warranty
DIG CORPORATION warrants these products to be free from defects in material and workman-
ship for a period of three years from date of purchase. This warranty does not cover damage
resulting from accident, indoor uses, misuse, neglect, modication, improper installation or
subjection to line pressure more than 125 lbs. per square inch for anti-siphon valves, in-line
valves and from an actuator. This warranty shall extend only to the original purchaser of the
product for use by the purchaser. The obligation of DIG CORPORATION under this warranty
is limited to repairing or replacing at its factory this product which shall be returned to the
factory within three years after the original purchase and which on examination is found
to contain defects in material and workmanship. DIG CORPORATION SHALL IN NO EVENT
BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND; THE SOLE
OBLIGATION OF DIG BEING LIMITED TO REPAIR OR REPLACEMENT OF DEFECTIVE PROD-
UCTS. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR
CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO
YOU. Unattended use for prolonged periods without inspection to verify proper operation is
beyond the intended use of this product, and any damage resulting from such use shall not
be the responsibility of DIG CORPORATION. There are no warranties, which extend beyond the
description on the face hereof. In the case of purchase of the product for use other than, for
irrigation purposes, DIG CORPORATION hereby disclaims any implied warranties including any
warranties of merchantability and tness for a particular purpose. In the case of the purchase
of the product for personal, family or household purposes, DIG CORPORATION disclaims any
such warranties to the extent permitted by law. To the extent that any such disclaimer or
implied warranties shall be ineffectual, then any implied warranties shall be limited in dura-
tion to a period of three years from the date of the original purchase for use by the purchaser.
Some states do not allow limitation on how long an implied warranty lasts, so the above limi-
tation may not apply to you. In order to obtain performance under this warranty, the unit must
be returned to the factory, along with proof of purchase indicating original date of purchase,
shipping prepaid, addressed as follows: DIG CORPORATION, 1210 Activity Drive, Vista, CA
92081. Repaired or replaced units will be shipped prepaid to the name and address supplied
with the unit returned under warranty. Allow four weeks for repairs and shipping time. Repair
of damaged units not otherwise within warranty may be refused or done at a reasonable cost
or charge at the option of DIG CORPORATION. This warranty gives you specic legal rights,
and you may also have other rights, which vary from state to state.
This device complies with FCC and IC radiation exposure limits set forth for an uncontrolled
environment. The device should be installed and operated with a minimum distance of 20cm
between the radiator and your body. This device must not be collocated or operating in conjunction
with any other antenna or transmitter.

www.digcorp.com
dig@digcorp.com
26-304 REV A 031518
Printed in the USA
DIG is a Registered Trademark of DIG Corp.
I. Changes or modications not expressly approved by DIG Corporation could void the user’s
authority to operate the equipment.
II. This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
III. Industry Canada
This device complies with Industry Canadalicence-exemptRSSstandard(s). Operation is
subject to the following two conditions: (1) this device may not cause interference, and (2)
this device must accept any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme auxCNRd’Industrie Canada applicables aux appareils
radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1)
l’appareil ne doit pas produire de brouillage, et (2) l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en compromettre le
fonctionnement.
Other manuals for 410BT Series
2
Table of contents
Other DIG Timer manuals
Popular Timer manuals by other brands

Rain Bird
Rain Bird SST1200OUT Setup & operation instructions

Stanley
Stanley PLUGBANK 3 SELECT operating instructions

Thermorail
Thermorail TRTS Installation & user guide

CIAT
CIAT V300 Control manual

Salter
Salter Heston Blumenthal 340A HBBKXR Instructions and guarantee

Robic
Robic SC-502T operating instructions

TJERNLUND
TJERNLUND 950-0453 PAI-T TIMER-CLOCK KIT 8504045 REV. 1... manual

Westinghouse
Westinghouse T28440 quick start guide

Greiner Bio-One
Greiner Bio-One Sed Rate Timer 10/II user manual

ENDA
ENDA ETM442 Series manual

Grasslin
Grasslin talento easy operating instructions

Novatek-electro
Novatek-electro TK-415 Operation manual