Digi-Code DGA User manual

Group Company
SVENSKA
ENGLISH
* Refer to Limited Lifetime Warranty / Se villkor för Limited Lifetime Warranty
INSTALLATIONSMANUAL
Vattentätt kompaktkodlås med bakgrundsbelysning
Digicode® keypad/ Digicode® kodlås
INSTALLATION MANUAL

2cdvi.se
cdvigroup.com
120
98 25
Illuminated keypad.
Cast aluminium body.
2 relay.
Surface mount.
Free voltage**
100 user codes.
Torx®mounting screws.
2 relay outputs, N/O and N/C contact 8A/250V.
100 user codes in 4 to 6 digits.
All programming stored in non-volatile
EEPROM memory.
1 request-to-Exit input.
1 master code.
Modication of Pin code by the user.
Visual and sound feedback.
Keypad Illumination :
Permanent or timed.
Operating voltage:
- 12V to 24VAC,
- 12V to 48VDC.
Consumption :
25 to 80 mA.
Its design and its high resistance to vandalism make it suitable to secure residential as well
as industrial sites. Its compatibility with all CDVI locking devices gives you the exibility to set
your own personalized system while keeping a high security level.
IP67
Environmental tests
Salt spray
-25°C à +70°C
CE Certication
HIGH RESISTANCE
TO VANDALISM
WEEE & RoHS
Cast aluminium Digicode® Self Contained
- No code programmed in the keypad, - Programming mode time: 120 seconds,
- Illumination time: 10 seconds, - Sub master code for user to reprogram its Pin code group #1: A and B,
- Relay output time: 1 second, - Sub master code for user to reprogram its Pin code group #2: 1 and 3,
- Code length: 5-digits, - Red LED lights on when the keypad is powered.
- Master code: 12345,

3
cdvi.se
cdvigroup.com
Cast aluminium Digicode® Self Contained
- 1 short beep > Keypad powered,
- 1 long beep > data computing in programming or access granted,
- 2 short beeps > Enter or Exit from programming,
- 4 short beeps > Data computing error.
- All the keypad keys can be used to program a code,
- The master code and the Pin code can be of 4, 5 or 6-digits,
- The master code CAN NOT be used as a PIN code (User Pin code),
- Codes 000000, 00000 and 0000 can only be used to delete a user code,
- To delete a specic User Code replace it by 0000 if code length is 4-digit format or replace it
by 00000 if the code is in 5-digit format.
P1 input activates relay 1. (The output can be programmed) :
- The timer input H1 if connected allows using the 0 key as a request-to-enter,
- If the timer contact is open then the 0 digit key is used for the Pin code,
- if the contact is closed then the 0 key is used for the request-to-enter.
- 12V AC: in stand-by 20 mA, when 2 relay outputs activated 80 mA max,
- 24V AC: in stand-by 10 mA, when 2 relay outputs activated 40 mA max.
1] Enter the master code twice (12345 default value master code):
- the red LED lights on to conrm entry in programming mode.
2] Press A6 to enter in the reset menu:
- the green LED lights on for 1 second,
- press simultaneously on A and B to start the reset,
- the green LED lights during all the reset process, wait until it lights off,
- the master code is reset to its factory value 12345 and all the user codes are deleted,
- the keypad is reset to the factory default values, the red LED lights on then lights off.
------------------------------------------------------ OR ---------------------------------------------------------
1] Turn off the power. Short the white and the yellow wires.
2] Power on the keypad:
- the green LED lights on,
- wait a few seconds, one beep is emitted. The green LED lights off. Unshort the wires.
3] The keypad is reset to the factory default values.
1] Enter the master code twice (12345 default value master code) :
- the red LED lights on to conrm entry in programming mode
2] Press A4 to program the code length:
- the green LED lights on during 1 second,
- press 4, 5 or 6 to enter the code length,

4cdvi.se
cdvigroup.com
Cast aluminium Digicode® Self Contained
- the green LED lights on during 1 second to conrm programming of the code length.
3] Enter A5 to modify the master code:
- the green LED lights on during 1 second,
- enter the new 4 or 5 or 6-digit master code,
- the green LED lights on during 1 second to conrm programming of the new master code.
4] Press B to exit from programming mode:
- the red LED lights off to conrm exit from programming.
The red LED ashes 4 times to indicate a data computing error
12369
enter 2369
enter 012369
It is recommended to program the codes in 6-digits
and then modify the code length.
1] Enter the master code twice (12345 default value master code):
- the red LED lights to conrm entry in programming mode.
2] Press A5:
- the green LED lights on during 1 second,
- enter the new master code (according to the code length set up),
- the green LED lights on during 1 second to conrm programming.
3] Press B to exit from programming mode. The red LED lights off to conrm exit from programming.
from user number 00 to user number 59, relay 1
from user number 60 to user number 99, relay 2
1] Enter the master code twice (12345 default master code):
- the red LED lights on to conrm entry in programming mode.
- pour programmer des codes :
2] To add a user code, enter the user number (from 00 to 99):
- If the user number is free, the green LED lights during 1 second enter the 4, 5 or 6-digit code,
- If the user number is already programmed, the red LED ashes 4 times,
- To modify the user code enter a 4, 5 or 6 digit code,
- To cancel the user code enter 000000 or 00000 or 0000 code,

5
cdvi.se
cdvigroup.com
Cast aluminium Digicode® Self Contained
- The green LED lights on duri ng 1 second to conrm programming.
If the user code is already programmed or is identical to the master code,
then the red LED
ashes 4 times to indicates a data computing error.
Note that the codes 000000 or 00000
or 0000 are strictly used to deleted a user code only.
3]
Press B to exit from programming mode. The red LED lights off to conrm exit from programming.
00 25 50 75
01 26 51 76
02 27 52 77
03 28 53 78
04 29 54 79
05 30 55 80
06 31 56 81
07 32 57 82
08 33 58 83
09 34 59 84
10 35 60 85
11 36 61 86
12 37 62 87
13 38 63 88
14 39 64 89
15 40 65 90
16 41 66 91
17 42 67 92
18 43 68 93
19 44 69 94
20 45 70 95
21 46 71 96
22 47 72 97
23 48 73 98
24 49 74 99
1] Enter the master code twice (12345 default value master code):
- the red LED lights on to conrm entry in programming mode
2] Press A0 to program the key-in keypad time and the illumination time:

Cast aluminium Digicode® Self Contained
6cdvi.se
cdvigroup.com
- the green LED lights during 1 second. Enter the time in 10th of second 10 for 10 seconds up to 99 for 99
seconds the backlighting dims 10 seconds after the last keypress or switches off after entering a valid code,
- enter 00 for a permanent illumination keys. The green LED lights during 1 second.
3] Press A1 to program relay 1 output time (door release time):
- the green LED lights during 1 second,
- for a timed output enter the time in seconds 01 for 1 second up to 99 for 99 seconds,
- enter 00 for a latched output,
- the green LED lights during 1 second to validate the time.
4] Press A2 to program relay 2 output time (door release time):
- the green LED lights during 1 second,
- for a timed output enter the time in seconds – 01 for 1 second up to 99 for 99 seconds,
- enter 00 for a latched output. The green LED lights during 1 second to validate the time.
5] Press B to exit from programming mode:
- the red LED lights to conrm exit from programming.
The red LED ashes 4 times to indicate a data computing error.
Short the white and the yellow wires:
- the green LED lights on,
- one beep is emitted,
- wait until the green LED lights off. Separate the two wires,
- the master code is reset to the factory default value 123456 in 6-digit code length, 12345 in 5-digit
code length or 1234 in 4-digit code length.
To authorize a user to modify its own User code short the blue and the yellow wires (Separate the two wires
to disable this function).
1] Enter the old user code:
- the relay is activated and the green LED lights on.
2] Enter the 2-digit sub master code (default sub master code A and B):
- the red LED lights on to authorize the modication.
3] Enter the new user code:
- the green LED lights during 1 second to conrm the new user code The red LED lights off.
4] Check the new user code to make sure of the modication.
The Sub Master code allows the user to change its own code without entering in programming mode. For
security reasons the code need to be changed periodically. This feature makes it easier and faster to change
its code
1] Enter the master code twice (12345 default master code):
- the red LED lights on to conrm entry in programming.

Cast aluminium Digicode® Self Contained
7
cdvi.se
cdvigroup.com
2] Press A7 to program a sub master code for the user individual Pin code modication of Group 1:
- the green LED lights on during 1 second,
- enter the new 2-digit sub master code,
- the green LED lights on during 1 second to conrm programming of the sub master.
3] Press A8 to program a sub master code for the user individual Pin code modication of Group 2:
- the green LED lights on during 1 second,
- enter the new 2-digit sub master code,
- the green LED lights on during 1 second to conrm programming of the sub master.
4] Press B to exit from programming:
- the red LED lights off to conrm exit from programming.
The audible signal is enabled in programming mode and when the relay is energised after a valid code.
To enable the audible feedback on a key press:
1] Enter the master code twice (12345 default value master code):
- 2 beeps are emitted to conrm entry in programming mode.
2] Press A twice:
- One beep is emitted,
- Press 0 to disable the audible signal during a keypress,
- Press 1 to enable the audible signal during a keypress,
- One beep conrms the modication.
3] Press B to exit from programming:
- 2 beeps are emitted to conrm exit from programming mode.

8cdvi.se
cdvigroup.com
P1
H
V
V
V
This device comes with a
varistor. The varistor must
be connected on the strike
terminal (electromagnet…)
operated by the device. If
this product operates more
than one strike, each lock
should have a varistor. The
varistor controls the overload
produced by the strike coil –
back emf.
Input voltage 12V or 24V AC or DC
Input voltage 12V or 24V AC or DC
Relay 1 N/C contact
Relais 1 common
Relay 1 N/O contact
Common
Relay 1 request-to-exit input
H Timer input
User code modication
Relay 2 N/C contact
Relais 2 common
Relay 2 N/O contact
Reset
Varistor
12V à 24VAC
12V à 48VDC
Locking devices
230 V ELECTROMAGNET
Black
Red
Pink [C1]
Brown [NC]
Orange [NO]
Yellow
Dark green
Light green
Blue
Purple [C2]
Gray [NO]
Dark blue [NC]
White
STRIKE
RESET
230 V
Cast aluminium Digicode® Self Contained

9
cdvi.se
cdvigroup.com
11122
(X2)
(X2)
Digicode
Once you have made sure that the mounting kit is complete and that you prepared the cables
of the DGA keypad then you can proceed and mount the product. Make sure that you have
all the appropriate tools (drill, screw drivers and a meter tape...) and follow the mounting
instructions of the DGA keypad.
Take the marks with the back plate
of the DGA. Drill the 2 mounting
holes (Ø 5 MM bit and 35 MM depth
minimum) and the wiring access
hole.
Insert the 2 plastic anchors. Then
mount the back plate of the DGA
keypad, and screw on the wall with
the (M4x30) mounting screws.
Insert the cable of the keypad in
the wiring access area.
Place the keypad on the back plate
top rst and then make sure that it
ts all over the back plate.
fasten the screw at the buttom
of the DGA keypad with the Torx®
screw using the spanner.
Cast aluminium Digicode® Self Contained

10 cdvi.se
cdvigroup.com
CDVI warrants this product to be free from defects in material and workmanship, when it has been installed
in accordance with the manufacturer’s instructions and has not been modied or tampered with. Only product
recognized by CDVI to be defective should be returned under these warranty terms if accompanied
by an RMA (Return Material Authorization Number) provided by CDVI. CDVI, at its option, shall repair
or replace the defective product at CDVI premises or at any CDVI approved service center. This warranty
does not cover any damage due to accident, misuse, abuse or negligence. This warranty is valid only
if the product is registered, within 1 month from delivery to the nal costumer. To obtain full details of this
warranty and to register the product to commence the “Limited Lifetime Warranty”, complete the enclosed
registration card and return it, either by e-mail or post, to the relevant CDVI address or completion of the
on line registration at www.cdvigroup.com. Repair or replacement of the defective product is the exclusive
remedy. CDVI shall not be liable for any incidental or consequential damages arising from any defect in, or
malfunction of, its product. In no event the entire liability can not exceed the purchase price of the product.
The CDVI local country contact details can be found on line by visiting www.cdvigroup.com or on the back
cover of the installation manual.
EXCEPT AS STATED ABOVE, CDVI MAKES NO WARRANTIES, EITHER
EXPRESS OR IMPLIED, AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITION OF ITS PRODUCTS,
THE TRANSPORTATION, THEIR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
*Refer to Limited Lifetime Warranty conditions
Cast aluminium Digicode® Self Contained