ZKTeco C3 Pro User manual

Quick Start Guide
C3 Pro
+
ZKBioSecurity 3.0

2
C3 Pro Series Access Control Panels and ZKBioSecurity 3.0 Quick Start Guide
CONTENT
ContentsWhat’s in the Box......................................................................2
Optional accessories..............................................................4
Safety Precautions....................................................................5
Product PIN Diagram.............................................................6
LED Indicators.............................................................................7
Product Dimension.................................................................8
Installation of Panel & Cabinet........................................9
Wiring Legend.........................................................................10
Power Wiring Diagram .....................................................11
Without Backup Battery ........................................................ 11
With Backup Battery ............................................................... 11
Wiegand Connection........................................................ 12
REX Connections.................................................................. 13
Lock Connection .................................................................. 14
Normally Open Lock Powered From Lock Terminal...... 14
Normally Closed Lock Powered From Lock Terminal.... 14
Switching from Dry to Wet................................................... 15
Connecting a lock with external power supply ............. 16
Aux. I/O connection .......................................................... 17
Aux. Input Connection .......................................................... 17
Aux. Output Connection....................................................... 17
Ethernet Connection ........................................................ 18
LAN Connection...................................................................... 18
Direct connection ................................................................... 18
RS485 Connection .............................................................. 19
Restore factory setting........................................................... 20
DIP Switch Setting............................................................... 21
RS485 Address.......................................................................... 21
Terminal Resistance ................................................................ 21
Installation Diagram............................................................22
Troubleshooting ....................................................................23
PC 485 Setting Table .......................................................... 24
Electrical Specifications ...................................................26
Specifications ..........................................................................27
ZKBioSecurity
Software
Installation and
Setup starts at
Page 29

3
C3 Pro Series Access Control Panels and ZKBioSecurity 3.0 Quick Start Guide
What’s in the Box
4 Diode2 Screws & Anchors 2 Screwdriver

4
C3 Pro Series Access Control Panels and ZKBioSecurity 3.0 Quick Start Guide
Optional accessories
Wiegand Card Reader
RS485 Convertor
Alarm
Prox Card
Card Enroller
PTE-1 Exit Button
C3 Pro Cabinet

5
C3 Pro Series Access Control Panels and ZKBioSecurity 3.0 Quick Start Guide
Safety Precautions
The following precautions are to keep user’s safe and prevent any damage.
Please read carefully before installation.
Do not install the device in a place subject to direct sun
light, humidity, dust or soot.
Do not place a magnet near the product. Magnetic objects
such as magnet, CRT, TV, monitor or speaker may damage
the device.
Do not place the device next to heating equipment.
Be careful not to let liquid like water, drinks or chemicals
leak inside the device.
Do not let children touch the device without supervision.
Do not drop or damage the device.
Do not disassemble, repair or alter the device.
Do not use the device for any other purpose than specied.
Clean the device often to remove dust on it. In cleaning, do
not splash water on the device but wipe it out with smooth
cloth or towel.
Contact your supplier in case of a problem.

6
C3 Pro Series Access Control Panels and ZKBioSecurity 3.0 Quick Start Guide
Product PIN Diagram
Figure 1
4 Aux Inputs
Reserved
Lock Power
Power
4 Lock & Door Sensor
4 Aux Output
RS485 Communication
DIP Switches
Ethernet Port
#1 Door Exit Button
#1 Door Card Reader
#2 Door Exit Button
#2 Door Card Reader
#3 Door Exit Button
#3 Door Card Reader
#4 Door Exit Button
#4 Door Card Reader
485 LED
Status LED
ACT LED
SD Card Slot

7
C3 Pro Series Access Control Panels and ZKBioSecurity 3.0 Quick Start Guide
LED Indicators
LINK Solid Green LED indicates TCP/IP
communication is normal.
Flashing (ACT )Yellow LED indicates
data communication is in progress.
EXT RS485 (TX/RX) Flashing Yellow
& Green LED indicates communication is
in progress.
Flashing (POWER) Red LED indicates
the panel is powered on.
Flashing (RUN) Green LED indicates
that panel is in normal working state.
Flashing (CARD) Yellow LED indicates
that the card is read by the panel.
Figure 2
Figure 3
Figure 4
Figure 5
Figure 7
Figure 6

8
C3 Pro Series Access Control Panels and ZKBioSecurity 3.0 Quick Start Guide
Product Dimension
Figure 9
C3-100 Pro C3-200 Pro C3-400 Pro
C3 Pro- Metal Cabinet
Figure 8
8.00 in
(203.2 mm)
6.325 in
(160.6 mm)
4.17 in (106 mm)
4.17 in (106 mm)
4.17 in (106 mm)
13.625 in (330.2 mm)
11.75 in
(279.4mm)
3.56 in
(90.5 mm)

9
C3 Pro Series Access Control Panels and ZKBioSecurity 3.0 Quick Start Guide
Installation of Panel & Cabinet
+--
Cable Conduit
(Punch Hole for cables)
Mounting Holes
We recommend drilling the mounting plate screws into solid wood (i.e. stud/beam). If a stud/beam cannot be
found, then use the supplied drywall plastic mollies (anchors).
Figure 10
Figure 11
Power Supply
C3 Pro Panel
Heat Dissipation Grill
Backup Battery

10
C3 Pro Series Access Control Panels and ZKBioSecurity 3.0 Quick Start Guide
Wiring Legend
Figure 12
Ethernet Cable
RS485
485 Convertor
Floodlight
ALARM
Normally Open Lock
12V DC Power Supply
12V DC Power
Normally Close Lock
P
U
S
H
T
O
T
E
S
T
W
E
E
K
L
Y
P
U
S
H
T
O
T
E
S
T
W
E
E
K
L
Y
FIRE
ALARMDetector
IR Sensor
PTE-1 Exit Button
Card Reader
PTE-1 Exit Button
Card Reader

11
C3 Pro Series Access Control Panels and ZKBioSecurity 3.0 Quick Start Guide
Power Wiring Diagram
Without Backup Battery
With Backup Battery
Switching Power Supply
Ground
Ground Switching Power Supply
Figure 14
Figure 13
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON

12
C3 Pro Series Access Control Panels and ZKBioSecurity 3.0 Quick Start Guide
Wiegand Connection
Wiegand Card Reader
Figure 15
16 or 18 AWG shielded
cable recommended
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON
Beeper
Green LED
Wiegand D1
Wiegand D0
GND
DC+(6-14V)

13
C3 Pro Series Access Control Panels and ZKBioSecurity 3.0 Quick Start Guide
REX Connections
Figure 16
PTE - 1 Exit Button
IR Sensor
Separate Power Supply
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON
Unused
NO
COM
12V DC ( + )
12V DC ( - )
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON
BUTTON
GND

14
C3 Pro Series Access Control Panels and ZKBioSecurity 3.0 Quick Start Guide
Lock Connection
Connecting a lock with external power supply
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON
FR107
Diode
GND
GND
12V DC
12V DC
ETHERNET
Figure 17
+
-
Sensor
Sensor
Door Contact

15
C3 Pro Series Access Control Panels and ZKBioSecurity 3.0 Quick Start Guide
Switching from Dry to Wet
Important Notes:
The factory default jumper setting is set as dry mode. If you want to power the
lock from the panel, you must take the following steps:
1. Take apart the cover of C3-400 Pro. Push the tab inward (see gure 21)
2. Select the appropriate lock relay and nd its jumpers
3. Take o the jumpers and change to
4. Connect the lock as show in the diagram, (see gure 23 and 24)
Select one Relay
Default setting
1, 2 - 3, 4
Take o jumpers Jumpers Plug Jumpers
2, 3 - 4, 5
Figure 19
Figure 18
V+
V-
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 L
OCK
C3-400 Pro 4 Lock Relays

16
C3 Pro Series Access Control Panels and ZKBioSecurity 3.0 Quick Start Guide
Lock Connection
Normally Open Lock Powered From Lock Terminal
(Wet Contact)
Normally Closed Lock Powered From Lock Terminal
(Wet Contact)
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON
12V DC
12V DC
12V DC
12V DC
GND
GND
FR107
Diode
FR107
Diode
GND
GND
ETHERNET
ETHERNET
Figure 20
Figure 21
+
-
+
-
16 or 18 AWG shielded cable recommended

17
C3 Pro Series Access Control Panels and ZKBioSecurity 3.0 Quick Start Guide
Aux. I/O Connection
Aux. Input Connection
Figure 23
Aux. Output Connection
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON
12V DC
12V DC
12V DC
GND
GND
P
U
S
H
T
O
T
E
S
T
W
E
E
K
L
Y
P
U
S
H
T
O
T
E
S
T
W
E
E
K
L
Y
FIRE
ALARM
ALARM
ETHERNET
ETHERNET
Figure 22
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON

18
C3 Pro Series Access Control Panels and ZKBioSecurity 3.0 Quick Start Guide
Ethernet Connection
LAN Connection
Important Notes:
1. Both 10Base-T and 100Base-T are supported
2. This cable distance must be less than 330 ft. (100m)
3. For cable length of more than 330 ft. (100m). use HUB to amplify the signal.
Figure 25
USB
USB
Direct connection
To connect C3-400 Pro with a PC directly, connect both devices with a straight network
cable. As the C3-400 Prosupports auto MDI/MDIX, it is not necessary to use a crossover
type cable.
CR10 Card Issuer
CR10 Card Issuer
ETHERNET
ETHERNET
Figure 24
CAT5e or CAT6 ethernet
cable recommended

19
C3 Pro Series Access Control Panels and ZKBioSecurity 3.0 Quick Start Guide
RS485 Connection
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC
AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC
AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC
AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON
RS485
#1 C3-400 Pro #2 C3-400 Pro #63 C3-400 Pro
RS485 --
RS485 +
GND
Important Notes:
1. RS485 communication wires should be a shielded twisted
pair cable. RS485 communication wires should be connected
in a bus cascade topology instead of a star topology, to
achieve a better shielding eect by reducing signal reection
during communications.
2. A single RS485 bus can connect up to 63 access control
panels, but preferably 32 is recommended maximum.
3. To eliminate signal attenuation in communication cables and
suppress interference, if the bus is longer than 200 meters,
set the number 8 DIP switch to the ON position. This is
equivalent to a parallel connection of one 120ohm resistance
between the 485+ and 485- lines.
12345678
ON
12345678
ON
SINGLE C3-400 Pro
MULTI C3-400 Pro
Incorrect RS 485 connections
Distance: More
than 200 meters
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC
AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC
AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC
AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC
AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC
AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON
+
+
+
BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2
TX
RX
TX
ACT
LINK
RX
POWER RUN CARD
AUX 1
IN
GND
IN
GND
IN
GND
IN
GND
+12V
GND
485-
485+
AUX 2 AUX 3 AUX 4 EXT EXT
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
NO
COM
NC
485+
485--
GND
PC
AUXOUT1
NO
COM
NC
AUXOUT2
NO
COM
NC
AUXOUT3
NO
COM
NC
V+
V-
12V
GND
AUXOUT4
SEN
GND
NO
COM
NC
LOCK1
SEN
GND
NO
COM
NC
LOCK2
SEN
GND
NO
COM
NC
LOCK3
SEN
GND
NO
COM
NC
LOCK4 LOCK POWER
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON READER
12345678
ON
RS485
#1 C3-400 Pro
#1 C3-400 Pro
#2 C3-400 Pro
#2 C3-400 Pro
#63 C3-400 Pro
#63 C3-400 Pro
RS485 --
RS485 +
GND
RS485 --
RS485 +
GND
RS485
x
x
Figure 26
Figure 27
Figure 28

20
C3 Pro Series Access Control Panels and ZKBioSecurity 3.0 Quick Start Guide
RS485 Connection
12345678
ON
12345678
ON
12345678
ON
12345678
ON
1
2
4
8
16
32
Restore Factory Setting
RS485 Terminal Resistance
Restore factory setting
1. If you forget the IP address of the C3 panel or the device does not work normally,
you can use the number 7 DIP switch to restore C3-400 Pro to factory default set-
tings. The parameters which gets reset are device IP address,
communication password, gateway, and subnet mask.
2. The switch is OFF by default. When it is moved up and down for three times
within 10 seconds and nally returned to OFF position, the factory settings will be
restored after the access control panel is restarted.
OFF OFF
ON
To reset factory settings
Turn #7 switch ON and OFF
Repeat process 3 times
Figure 29
Figure 30
Table of contents
Other ZKTeco IP Access Controllers manuals
![ZKTeco G4[QR] User manual ZKTeco G4[QR] User manual](/data/manuals/1j/2/1j2wo/sources/zkteco-g4-qr-ip-access-controllers-manual.jpg)
ZKTeco
ZKTeco G4[QR] User manual

ZKTeco
ZKTeco F6 User manual

ZKTeco
ZKTeco EFace10 User manual

ZKTeco
ZKTeco MultiBio 700 User manual

ZKTeco
ZKTeco C2-260/inBio2-260 User manual

ZKTeco
ZKTeco SA40 User manual

ZKTeco
ZKTeco KF1000-U User manual

ZKTeco
ZKTeco F19 User manual

ZKTeco
ZKTeco ProCapture-WP User manual

ZKTeco
ZKTeco ProlD Series User manual

ZKTeco
ZKTeco FaceKiosk-H10A User manual

ZKTeco
ZKTeco SilkID F21-ID User manual

ZKTeco
ZKTeco BioPro SA50 User manual

ZKTeco
ZKTeco Ultima Series User manual

ZKTeco
ZKTeco C2-260 User manual

ZKTeco
ZKTeco FA50 User manual

ZKTeco
ZKTeco OP-200 User manual

ZKTeco
ZKTeco X7 User manual

ZKTeco
ZKTeco SLK21M User manual

ZKTeco
ZKTeco F18 User manual