manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Dimplex
  6. •
  7. Heater
  8. •
  9. Dimplex FX 20V User manual

Dimplex FX 20V User manual

Operating and Installation Instructions
FX 20 V Downflow Fan Heater 453321.66.70gb 09/03/A
1. Warnings
You are requested to read carefully all the information in
these instructions. Keep these instructions carefully and if
applicable pass them on to the final owner.
− The appliance is only to be used for the heating of
dwellings or similar spaces. It is only suitable for domestic
use or similar purposes within enclosed spaces.
− Repairs to the appliance are only to be carried out by a
competent electrician.
− In the event of a fault disconnect the electricity supply to
the appliance (turn off or remove the fuse).
− By covering the heater could cause a heat build up and
possibly lead to material igniting. You must observe the
minimum clearances.
− The surfaces, especially the air-outlet grille, become hot
during operation. For this reason ensure that small
children cannot touch these surfaces.
− No objects should be inserted through the openings of
the appliance.
− It is particularly important that the appropriate safety
− regulations for bathrooms, showers, swimming pools
etc. are fulfilled.
− The heater is to be installed in such a way that it cannot
be touched from a person in the bath or shower and that
the switch cannot be operated.
− The fixed installation must be provided with a switching
device having a contact separation of 3 mm in all poles
(e.g. overload release).
− No materials can be used in the room where the
appliance is installed whose fumes or the material itself
could give rise to ignition, explosion or thermal
decomposition due to the high temperatures.
2. Description
Heating capacity : 2 kW, 1 kW (depending on pre-setting)
Supply voltage : 1/N/~230V, 50 Hz
Construction class II: double insulated
System of protection: IP 22
Dimensions (W x H x D) : 229 x 109 x 242 mm
Weight : 1.4 kg
3. Minimum clearances, installation
The sketch below shows the drilling dimensions and the
dimensions for the cable entry.
229
188
116 100
12
242
30
• The minimum clearances given in the mounting sketch
are to be observed.
• The heater must not be located immediately below a
fixed socket outlet.
• Do not place easily combustible objects, such as
curtains or heat sensitive plastics, in the direct airflow
from the unit.
• The fan heater should only be mounted on a vertical
wall as shown in the sketch below.
• Furthermore there must be a clearance of at least 350
mm from the front of the heater.
To fix the heater, remove the two screws securing the top
cover and remove the cover from the heater.
− Mark the position of the keyhole slots on the wall, drill
and plug for the two suitable screws (see sketch for
position).
− Partially insert the two screws, then hang the appliance
on these screws and mark the position of the lower
positioned screw.
− Remove the appliance, drill and plug the third screw.
− Remount the appliance on the wall and insert the supply
cable. Ensure that the appliance is horizontal and fix in
position by tightening the three screws.
1800
300
250
600
242
229
4. Electrical connection
Take care! The appliance must be installed by a
competent electrician.
The appliance may be connected directly to a fixed wiring or
to a flexible supply cable H05VV-F 2 x 1.0 mm² from a wall
connecting box.
The heater must not be located immediately above the wall
connecting box.
GB
5. Presetting
Take care! The settings must be carried out by a
competent electrician. Ensure that the appliance is
disconnected from the mains.
5.1 Selecting the heating capacity
The wall mounted fan heater is provided with an internal
selector switch with which the output can be set during
installation to 1 kW or 2 kW corresponding to the size of the
room to be heated.
In rooms of less than 11 m3in volume, the 1 kW output
should be selected as otherwise nuisance tripping of the
thermal cut-out may occur.
In case of selecting the 2 kW position, the thermostat is in
operation and will switch automatically to 1 kW when the
preselected temperature is achieved.
Note: the heater is preset to 2 kW.
5.2 Selecting the temperature
Note: the thermostat will only function when 2KW is
selected.
The heater is fitted with an adjustable thermostat, which has
three different settings : 1. - Low, 2. - Medium, 3 - High.
This gives you an approximate room temperature range of
18°C - 32°C depending on room size. The temperature
switches to half heat when the room warms up. Full heat will
be switched on automatically when the room temperature
falls.
The thermostat has been factory set on ‘2’ (Medium).
6. Heater operation
The pull cord operates the ON/OFF switch. The pilot lamp
will illuminate when the heater is switched on.
7. Faults
If the heater is not heating, check whether the heater is
switched on (pilot lamp must illuminate). Check that it is
switched on at the distribution board and that the fuse is
intact.
Further directions are explained in section "9. Thermal
safety cut-out".
In the event of malfunctions in your heater, please contact
your local electrician or the nearest customer service point.
The E-Number and the FD code are required before
servicing can be carried out. You will find them on the rating
plate.
8. Cleaning the appliance
Switch off the heater before cleaning and allow to cool.
If dust accumulates, the heater should be cleaned from the
outside using a vacuum cleaner.
The outside can be cleaned by wiping it over with a soft
damp cloth and then dried. Do not use abrasive cleaning
powders or furniture polish, as this can damage the surface
finish.
9. Thermal safety cut-out
For your safety the heater is fitted with a thermal cut-out.
If the air circulation is restricted (e.g. hanging something
over or blocking the grille) the heater switches off
automatically. In order to bring the heater back into
operation remove the cause of the overheating. Switch off
the heater for a few minutes by pulling the cord and allow to
cool down after which normal operation may be resumed.
In addition the appliance is fitted with a thermal fuse link.
If there is abnormal overheating within the appliance, it
operates and opens the circuit.
10. Guarantee
The guarantee terms issued by our representatives in the
country of purchase are applicable for this appliance. The
dealer from whom the appliance was purchased will provide
details at any time on request. Presentation of a receipt is
essential for the implementation of the guarantee terms.

Other manuals for FX 20V

5

Other Dimplex Heater manuals

Dimplex SmartRad SRX80 User manual

Dimplex

Dimplex SmartRad SRX80 User manual

Dimplex B075E User manual

Dimplex

Dimplex B075E User manual

Dimplex PPC0500 Installation instructions manual

Dimplex

Dimplex PPC0500 Installation instructions manual

Dimplex IRC 400 A User manual

Dimplex

Dimplex IRC 400 A User manual

Dimplex LC2507W31 User manual

Dimplex

Dimplex LC2507W31 User manual

Dimplex IRX60/120E User manual

Dimplex

Dimplex IRX60/120E User manual

Dimplex Evo Rad User manual

Dimplex

Dimplex Evo Rad User manual

Dimplex RCH5031CXW User manual

Dimplex

Dimplex RCH5031CXW User manual

Dimplex ARC10E User manual

Dimplex

Dimplex ARC10E User manual

Dimplex DCU18LCD User manual

Dimplex

Dimplex DCU18LCD User manual

Dimplex BN/60100 Series User manual

Dimplex

Dimplex BN/60100 Series User manual

Dimplex M2GTS User manual

Dimplex

Dimplex M2GTS User manual

Dimplex XHD23L-AU-RL User manual

Dimplex

Dimplex XHD23L-AU-RL User manual

Dimplex DX 410EP User manual

Dimplex

Dimplex DX 410EP User manual

Dimplex XLE Series User manual

Dimplex

Dimplex XLE Series User manual

Dimplex AC3CE User manual

Dimplex

Dimplex AC3CE User manual

Dimplex DGWH4031 User manual

Dimplex

Dimplex DGWH4031 User manual

Dimplex BFH24E User manual

Dimplex

Dimplex BFH24E User manual

Dimplex 2nc8 series User guide

Dimplex

Dimplex 2nc8 series User guide

Dimplex CAB Series User manual

Dimplex

Dimplex CAB Series User manual

Dimplex RKHA User manual

Dimplex

Dimplex RKHA User manual

Dimplex QXD1500 User manual

Dimplex

Dimplex QXD1500 User manual

Dimplex EUH02B21T User manual

Dimplex

Dimplex EUH02B21T User manual

Dimplex DIR Series User manual

Dimplex

Dimplex DIR Series User manual

Popular Heater manuals by other brands

Create WARM BOX user manual

Create

Create WARM BOX user manual

Sawo TH3-35NB manual

Sawo

Sawo TH3-35NB manual

Taurus tropicano 3C ceramic manual

Taurus

Taurus tropicano 3C ceramic manual

Vitek VT-2170 Manual instruction

Vitek

Vitek VT-2170 Manual instruction

EINHELL NKH 1500 operating instructions

EINHELL

EINHELL NKH 1500 operating instructions

Purmo BR222 Assembly instructions

Purmo

Purmo BR222 Assembly instructions

Clarke DEVIL 371SPD Operating & maintenance instructions

Clarke

Clarke DEVIL 371SPD Operating & maintenance instructions

GoodHome wilsona 3663602428565 manual

GoodHome

GoodHome wilsona 3663602428565 manual

Frico Panther S 20 Original instructions

Frico

Frico Panther S 20 Original instructions

Frico AREC4025E Series Original instructions

Frico

Frico AREC4025E Series Original instructions

aoyue INT853A Operation manual

aoyue

aoyue INT853A Operation manual

Herschel Vulcan Installation & operating instructions

Herschel

Herschel Vulcan Installation & operating instructions

L.B. White Foreman CI500 Owner's manual and instructions

L.B. White

L.B. White Foreman CI500 Owner's manual and instructions

Reece Kado Lussi MKII Operation and maintenance

Reece

Reece Kado Lussi MKII Operation and maintenance

ambiance pc14ss owner's manual

ambiance

ambiance pc14ss owner's manual

Westfalia JOKER Maintenance and operation

Westfalia

Westfalia JOKER Maintenance and operation

Stadler Form Anna operating instructions

Stadler Form

Stadler Form Anna operating instructions

HearthRite HB20ML-1 OWNER'S OPERATION AND INSTALLATION MANUAL

HearthRite

HearthRite HB20ML-1 OWNER'S OPERATION AND INSTALLATION MANUAL

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.