manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Dimplex
  6. •
  7. Heater
  8. •
  9. Dimplex IRX50N User manual

Dimplex IRX50N User manual



ContactDetails

Pleasenotethatsomeofthecontactdetailson
thisPDFdocumentmaynotbecurrent.

Pleaseusethefollowingdetailsifyouneedto
contactus:

Telephone:08448793588
Email:[email protected]


Thecustomersupportsectionofourwebsitealsofeaturesawide
rangeofinformationwhichmaybeofusetoyouandisavailable
24hoursaday.Itincludes:

•Operatingandinstallationinstructions
•Easy‘Howtouse’guidesforstorageheaters
•Serviceandrepairs
•Wheretobuyourproducts
•Literaturedownloads
•Heatingrequirementcalculator

Visit‐www.dimplex.co.uk/support
A division of GDC Group Ltd
Millbrook House Grange Drive Hedge End Southampton SO30 2DF
www.dimplex.co.uk
Re
g
istered No: 1313016 En
g
land
VAT GB 287 1315 50004
EEE Producer Registration Number –
WEE/GE0057TS
Paper from sustainable sources
08/51090/0 (UK) Issue 0
The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014,
EN60555-2 and EN60555-3. These cover the essential requirements of EEC Directives 2006/95/EC and 2004/108/EC
Models:
IRX50N, IRX120N, IRX200N
INFRA - RED HEATERS
1
3
5
600mm
1800mm
400mm
300mm
2
bb
bb
b
255mm
aa
aa
a
bb
bb
b
cc
cc
c
cc
cc
c
aa
aa
a
aa
aa
a
cc
cc
c
cc
cc
c
a
aa
aa
a
bb
bb
b
cc
cc
c
Infra - Red Heaters
Model(s) : IRX50N, IRX120N, IRX200N
THESEINSTRUCTIONSSHOULDBEREADCAREFULLYANDRETAINEDFORFUTUREREFERENCE
(IP24)
Important Safety Advice
Because the IRX Heater contains no moving parts little
maintenance is required. Before undertaking any
maintenance work on the heater due attention must be
paid to the following:
This heater is designed to be horizontally wall mounted
only, it must not be ceiling mounted.
Always ensure a safe mounting height, at or above a
minimum height of 1.8 metres from ground level, so that
the heater can not be touched when in operation.
The heater must be wall mounted level ± 5º to the
horizontal.
The appliance is not intended for use by young children
or infirm persons without supervision unless they have
been adequatelty supervised by a responsible person
to ensure that they can use the appliance safely.
Young childrenshouldbe supervised toensurethat they
do not play with the appliance.
Do not locate the heater immediately above or below a
fixed socket outlet or connection box.
Alwaysdisconnectthe heater from the electricity supply
before attempting to work on or near it.
Always ensure a safe means of access using an access
tower or properly supported ladder.
Do not cover the heater.
Keep combustible materials away from the heater.
Do not look into the heater for prolonged periods
Do not use the heater if the elements are broken - as
injury may occur.
Allow adequate time (minimum of 30 mins.) for the
elements and body casing to cool before attempting to
work on the heater.
Do not allow the supply cord to sit or hang in front of the
heater while in use.
Note: Provide sufficient slack to the cable to allow for
angular adjustment of the body.
The bulbs are extremely fragile and must be handled
with extreme care at all times. If the bulb is accidentally
touched by bare fingers remove the fingerprint with a
soft cloth moistened with methylated spirits. The device
mustbeinstalled in such a waythatit cannot be touched
by a person in the bathtub or under the shower.
General
The IRX range of infra-red wall heaters are a safe, practical
source of heat in bathrooms, kitchens, work areas - anywhere
where fast localised heating is required. The IRX uses quartz
elements which emit a warm glow of medium wave infra-
red. The IP24 rating means the appliance is suitably rated to
be permanently installed either internally or externally.
Electrical
The installation of this appliance should be carried out by a
competent electrician and be in accordance with the current
IEE wiring regulations and any local or insurance regulations.
The IRX range are designed for use on a 230-240VAC single
phase supply. A double pole isolating switch with a minimum
separation of 3mm in each pole must be fitted to facilitate
isolation. This switch must either be positioned inside a
building or have an IP rating against water ingress suitable
for external installation. The appliance must be supplied
through a residual current device (RCD) having a rated
residualoperatingcurrentnotexceeding30mA.Theappliance
must be connected to a socket-outlet having an earthing
contact (for Class I appliances).
Remove Packaging (See Fig.1)
Prior to installation remove the polystyrene inserts which
secure the elements during transportation.
a. Remove the two front grill screws.
b. Remove the front grill in the direction of the arrow.
c. Remove element protection polystyrene.
Replace front grill and reverse procedure.
Installation – Wall Mounting
The heater must be permanently fixed to the wall using the
wall mounting bracket and screws supplied. The heater must
be mounted Horizontally as shown observing the minimum
clearances stated in Fig. 2.
The minimum mounting height for the heater is 1.8 meters
whichrequires that the themountingholes for the wall bracket
be drilled at a height of 1.9 meters.
a. Removethescrew(a) to release the plastic control molding.
This will allow the unit to tilt forward and allow access to the
securing holes on the back of the unit - see Fig. 3.
b. Place heater horizontally against the wall, mark and drill
holes to suit and insert the two wall fixings supplied - see
Fig.3
c. Place the two plastic inserts into the holes provided on the
control housing and tighten screws to secure heater - see
Fig.3
Replace control molding and fix heater to required angle.
The bracket allows the heater to be inclined at the required
angle. The siting of the heater(s) should be such as to allow
an even and uninterrupted distribution of radiation to the
area(s) to be heated. Heaters are most effective when the
beam angle is inclined down at an angle of between 30º to
45º to the vertical. When deciding upon the best location,
consideration must be given to the following requirements:
a.Comfort and safety could be compromised unless the
heater is mounted at or above 1.8m from ground level.
b. The minimum clearance distances must be maintained
as shown in Fig. 2.
Model Watts
IRX50N 500W
IRX120N 1200W
IRX200N 2000W
GDC Group Ltd
Millbrook House
Grange Drive
Hedge End
Southampton
SO30 2DF
[c] GDC Group Ltd
All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Dimplex UK Limited. A division
of GDC Group Ltd
Operation
The desired heating level can be set by pulling the pull cord
switch once or repeatedly. The set heating level can be read
in the display window. In position “0” the heating device is
switched off.
Element Replacement (see Fig. 5)
WARNING–BEFOREUNDERTAKINGTHISTASKENSURETHE
HEATERISDISCONNECTEDFROMTHEELECRICITYSUPPLY
ANDLEFT TOCOOL FORAMINIMUM OF30 MINUTES.
1. Remove the two screws which hold the front grill onto the
heater.
2. Remove the front grill in the direction of the arrow.
3. Remove the two element securing clips to release the
element.
4. Disconnect the element wires from each side of the
element.
5. Reverse procedure with new element.
Cleaning and User Maintenance
WARNING: BEFORE UNDERTAKING CLEANING OR
MAINTENANCEWORK ONTHE APPLIANCE,DISCONNECT
THEELECTRICITYSUPPLY.
Since the appliance contains no moving parts little
maintenance is required beyond cleaning and element
replacement. It is however essential that the heater is not
operated with an accumulation of dust or dirt on the element,
as this can cause a build up of heat and eventual damage.
For this reason the heater must be inspected regularly,
depending upon conditions and at least at yearly intervals.
Allow adequate time for the element and body casing to cool
before attempting to work on the heater - a minimum time of
30 minutes is recommended.
If the bulb is accidentally touched by bare fingers remove the
fingerprint with a soft cloth moistened with methylated spirits.
Recycling
For electrical products sold within the European Community.
At the end of the electrical products useful life it should not be
disposed of with household waste.
Please recycle where facilities exist. Check with your Local
Authority or retailer for recycling advice in your country.
Tel: 0845 604 2330
Fax: 01489 773050
Website: www.gdcgroup.co.uk
Republic of Ireland Tel. 01 8424833
Model Display 0 Display 1 Display 2 Display3
IRX50N 500W
IRX120N 1200W
IRX200N 800W 1200W 2000W
After Sales Service
Your product is guaranteed for one year from the date of
purchase.
Within this period, we undertake to repair or exchange this
product free of charge (excluding element & subject to
availability) provided it has been installed and operated in
accordance with these instructions. Your rights under this
guarantee are additional to your statutory rights, which in
turn are not affected by this guarantee.
Should you require after sales information or
assistance with this product please contact our
help desk on 0845 6042330
Spare Part’s information can be found on our website
www.gdcgroup.co.uk by clicking on the Dimplex logo and
selecting the spares information tab.

This manual suits for next models

2

Other Dimplex Heater manuals

Dimplex QM100 User manual

Dimplex

Dimplex QM100 User manual

Dimplex XLS24N User manual

Dimplex

Dimplex XLS24N User manual

Dimplex QUBEFAN Q2TSNH User manual

Dimplex

Dimplex QUBEFAN Q2TSNH User manual

Dimplex Coldwatcher MPH 500 User manual

Dimplex

Dimplex Coldwatcher MPH 500 User manual

Dimplex MaxAir25 B User manual

Dimplex

Dimplex MaxAir25 B User manual

Dimplex AC3CN User manual

Dimplex

Dimplex AC3CN User manual

Dimplex PCH2000TCW-TK User manual

Dimplex

Dimplex PCH2000TCW-TK User manual

Dimplex Q-Rad QRAD050E User manual

Dimplex

Dimplex Q-Rad QRAD050E User manual

Dimplex CXLS12N User manual

Dimplex

Dimplex CXLS12N User manual

Dimplex AC3RE User manual

Dimplex

Dimplex AC3RE User manual

Dimplex QRAD150 User manual

Dimplex

Dimplex QRAD150 User manual

Dimplex Monterey User manual

Dimplex

Dimplex Monterey User manual

Dimplex BFH24T User manual

Dimplex

Dimplex BFH24T User manual

Dimplex CXLN User manual

Dimplex

Dimplex CXLN User manual

Dimplex DGP1000-B User manual

Dimplex

Dimplex DGP1000-B User manual

Dimplex B48 User manual

Dimplex

Dimplex B48 User manual

Dimplex XMCS712N User manual

Dimplex

Dimplex XMCS712N User manual

Dimplex DCU18LCD User manual

Dimplex

Dimplex DCU18LCD User manual

Dimplex PLX 500 User manual

Dimplex

Dimplex PLX 500 User manual

Dimplex 403TSFTIE7 User manual

Dimplex

Dimplex 403TSFTIE7 User manual

Dimplex PFH30 User manual

Dimplex

Dimplex PFH30 User manual

Dimplex RD 907 User manual

Dimplex

Dimplex RD 907 User manual

Dimplex OFRC15WTE User manual

Dimplex

Dimplex OFRC15WTE User manual

Dimplex PFH30R User manual

Dimplex

Dimplex PFH30R User manual

Popular Heater manuals by other brands

Eterna PFH2400 installation guide

Eterna

Eterna PFH2400 installation guide

LUXEVA LXV2000-TS instruction manual

LUXEVA

LUXEVA LXV2000-TS instruction manual

Desa BLP170VTA owner's manual

Desa

Desa BLP170VTA owner's manual

Homelite HHC50LP owner's manual

Homelite

Homelite HHC50LP owner's manual

Munters GA55 operating instructions

Munters

Munters GA55 operating instructions

EOS Stativ Terra Vita II Assembly instruction

EOS

EOS Stativ Terra Vita II Assembly instruction

STIEBEL ELTRON CON 5 Premium Operation and installation

STIEBEL ELTRON

STIEBEL ELTRON CON 5 Premium Operation and installation

Soleus Air NDY-15 owner's manual

Soleus Air

Soleus Air NDY-15 owner's manual

Lenoxx H500 manual

Lenoxx

Lenoxx H500 manual

wallas 270 Installation, operation and service instructions

wallas

wallas 270 Installation, operation and service instructions

MaxxHome 20722 User's manual and operating instructions

MaxxHome

MaxxHome 20722 User's manual and operating instructions

SKF TWIM 15 Instructions for use

SKF

SKF TWIM 15 Instructions for use

Möhlenhoff Basis AB 4071-6 manual

Möhlenhoff

Möhlenhoff Basis AB 4071-6 manual

Somogyi Home FKF 2000 LED instruction manual

Somogyi

Somogyi Home FKF 2000 LED instruction manual

Thermon Ruffneck RGE Series Installation & operation instructions

Thermon

Thermon Ruffneck RGE Series Installation & operation instructions

United Technologies Carrier 42AM Control manual

United Technologies

United Technologies Carrier 42AM Control manual

Rotel U707CH1 Instructions for use

Rotel

Rotel U707CH1 Instructions for use

AERMEC FCX US Direction for use and installation

AERMEC

AERMEC FCX US Direction for use and installation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.