TROUBLESHOOTING GUIDE - DWF1203
PROBLEM CAUSE SOLUTION
General
Circuit breaker trips or fuse
blows when unit is turned on
Short in unit wiring. Trace wiring in unit.
Improper circuit current rating Additional appliances may exceed the current
rating of the circuit breaker or fuse. Plug unit into
another outlet or install unit on a dedicated 15
amp circuit.
Unit turns on or off by itself Remote control has a similar frequen-
cy to other remotes in the area.
Replace Remote Control. Initialize to Remote
Control Receiver.
Radio frequency disturbance from
outside sources.
Replace Remote Control and Remote Control
Receiver where necessary. Initialize Remote
Control and Receiver
Defective Remote Control Receiver Replace Remote Control Receiver. Initialize to
Remote Control.
Lights dim in room while the
unit is on
Unit is drawing close to circuit current
rating
Move the unit to another outlet or install unit on a
dedicated 15 amp circuit
Power cord gets warm Normal Operation The power cord may get slightly warm to the
touch when the heater is on
Defective power cord Replace power cord if cord gets hot to the touch.
Appearance
Fireplace does not turn on in
Manual Mode
Improper operation Refer to Operation Section
No incoming power from the electrical
wall socket
Check Fuse/Breaker Panel
Defective On/Off Switch Replace On/Off Switch
Defective Remote Control Receiver Replace Remote Control Receiver. Initialize with
Remote Control.
Fireplace does not turn on in
Remote Mode
Improper operation Refer to Operation Section
Remote control not initialized to re-
place
Initialize the remote control
Loose wiring Check wiring connections
Remote Control not working Install new battery into the Remote Control. Re-
initialize remote control where necessary
Replace Remote Control Receiver where nec-
essary. Initialize Remote Control Receiver to
Remote Control.
Defective Remote Control Receiver Replace Remote Control Receiver. Initialize to
Remote Control
Flame Frozen Loose wiring Check wiring connections
Defective icker motor Replace icker motor
Flame not bright or ame not
visible
Loose wiring Check wiring connections
Defective LED light strip Replace LED light strip
Log set dim, not glowing Defective LED Log Driver Board Replace LED Log Driver Board
Flame Shudder Defective icker motor Replace icker motor
In keeping with our policy of continuous product improvement, we reserve the right to make changes without notice.
© 2012 Dimplex North America Limited
1367 Industrial Road Cambridge ON Canada N1R 7G8
1-888-346-7539 www.dimplex.com
PROBLEM CAUSE SOLUTION
Heater
Heater is not turning Off Improper operation Refer to Operation Section
Defective Heater On/Off Switch Defective Heater On/Off Switch
Defective Remote Control Receiver Replace Remote Control Receiver. Initialize to
Remote Control.
Heater is not turning On Improper operation Refer to Operation Section
Loose wiring Check wiring connections
Defective heater assembly Replace heater assembly
Heater is turning off after a
couple of minutes of operation
Build up of dirt/dust in heater assem-
bly
Ensure that exterior intake louvers and rebox
cavity are free of dirt/dust.
Defective Heater Assembly Replace Heater Assembly
Heater emits an odor Normal Operation Normal operation is when the heater emits an
odor for a brief period after the heater is initially
turned on. The heater is burning off any dust ac-
cumulated during manufacturing or operation.
Defective heater assembly Replace heater assembly
Heater fan turns on but heater
lacks heat
Improper operation Refer to Operation Section
Loose wiring Trace wiring in unit
Defective heater assembly Replace heater assembly
Heating element is glowing red Normal Operation Small glowing sections of the element are con-
sidered normal.
Defective heater assembly If larger glowing sections are causing the heater
to trip the thermal cutout, unplug unit, discon-
tinue use and replace heater assembly.
Heater fan runs continuously Loose wiring Trace wiring in unit
Defective heater assembly Replace heater assembly
Noise
Excessive noise with the
heater on
Dirty heater assembly Ensure that exterior intake louvers and re-
box cavity are free of dirt/dust.
Defective heater assembly Replace heater assembly
Grinding or excessive noise
with the heater off
Flicker rod hitting or rubbing
against internal components
Ensure rod is straight and mounted properly
in the bracket, spinning freely away from
other components. Replace if necessary.
Defective icker motor Replace icker motor
!NOTE: For any additional operational, servicing, replacement instructions or replacement
parts please see the associated Service Manual.

Other manuals for DWF1203

1

Other Dimplex Heating System manuals

Dimplex VFMQ User manual

Dimplex

Dimplex VFMQ User manual

Dimplex TIMRA User manual

Dimplex

Dimplex TIMRA User manual

Dimplex DuoHeat Duo300N User manual

Dimplex

Dimplex DuoHeat Duo300N User manual

Dimplex DF3033ST User manual

Dimplex

Dimplex DF3033ST User manual

Dimplex VSH LAK9 User manual

Dimplex

Dimplex VSH LAK9 User manual

Dimplex R7 User manual

Dimplex

Dimplex R7 User manual

Dimplex RXPW4 User manual

Dimplex

Dimplex RXPW4 User manual

Dimplex R10/73 - 10kW User manual

Dimplex

Dimplex R10/73 - 10kW User manual

Dimplex DWF1215 User manual

Dimplex

Dimplex DWF1215 User manual

Dimplex Quantum User manual

Dimplex

Dimplex Quantum User manual

Dimplex BF33STP User manual

Dimplex

Dimplex BF33STP User manual

Dimplex VFMQ User manual

Dimplex

Dimplex VFMQ User manual

Dimplex DF2550 User manual

Dimplex

Dimplex DF2550 User manual

Popular Heating System manuals by other brands

Aqua-Hot 400-P02 Use and care guide

Aqua-Hot

Aqua-Hot 400-P02 Use and care guide

Salda RIS 2500HW EKO 3.0 Technical manual

Salda

Salda RIS 2500HW EKO 3.0 Technical manual

Viessmann VITODENS 200 WB2B specification

Viessmann

Viessmann VITODENS 200 WB2B specification

Immergas 3.033210 Instruction and warning book

Immergas

Immergas 3.033210 Instruction and warning book

Master BV 77E Technical data

Master

Master BV 77E Technical data

flowair LEO KM L Technical documentation operation manual

flowair

flowair LEO KM L Technical documentation operation manual

Fresh-Aire UV TUVC-ADS-118D-HO-OS-100 Installation & maintenance

Fresh-Aire UV

Fresh-Aire UV TUVC-ADS-118D-HO-OS-100 Installation & maintenance

Oxygen X-Air V200E Installation and operation manual

Oxygen

Oxygen X-Air V200E Installation and operation manual

Immergas SUPER TRIO Instructions and warnings

Immergas

Immergas SUPER TRIO Instructions and warnings

aerauliqa QR400A Installation, use & maintenance manual

aerauliqa

aerauliqa QR400A Installation, use & maintenance manual

Legalett 4000E-24 manual

Legalett

Legalett 4000E-24 manual

Midea CE-HRV-800 Owners manual and installation manual

Midea

Midea CE-HRV-800 Owners manual and installation manual

Bryant HRVBBLHU Installation, start-up, and operating instructions

Bryant

Bryant HRVBBLHU Installation, start-up, and operating instructions

Hotstart CMM Installation & operation manual

Hotstart

Hotstart CMM Installation & operation manual

Honeywell S8700 Series installation instructions

Honeywell

Honeywell S8700 Series installation instructions

SIRE XROOM OPERATING AND INSTALLATION Manual

SIRE

SIRE XROOM OPERATING AND INSTALLATION Manual

Frapol Onyx SKY 250 Operation and maintenance manual

Frapol

Frapol Onyx SKY 250 Operation and maintenance manual

Roberts Gorden Dualair DA260G Series Installation, comissioning, service & user instructions

Roberts Gorden

Roberts Gorden Dualair DA260G Series Installation, comissioning, service & user instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.