Dimplex WPM 2006 plus User manual

Bedienungsanleitung
für den Benutzer
DeutschEnglishFrançais
Manuel d’utilisation
Operating instructions
for Users
Wärmepumpen-
Manager
für Nieder-, Mittel- und
Hochtemperatur–Wärme-
pumpen zum Heizen und
Kühlen
WPM 2006 plus
WPM 2006 R
WPM 2007 plus
WPM 2007 R
Heat Pump
Controller
for Low, Medium and
High-Temperature Heat
Pumps for Heating and
Cooling
Regulateur de
pompe à chaleur
pour des pompes à chaleur
à basse température,
à température moyenne
et à haute température
– pour le chauage et le
rafraîchissement
Bestell-Nr. / Order no. / Node commande : 452114.66.48 FD 8609

E-1
English
Table of Contents
1 General Information ........................................................................................................................................E-2
2 Heat Pump Manager........................................................................................................................................E-2
3 Quick Reference Instructions ........................................................................................................................E-3
3.1 Selection of the Operating Mode ...................................................................................................................................................E-3
3.2 Changing the Settings ...................................................................................................................................................................E-3
3.3 Settings and Operating Data .........................................................................................................................................................E-3
4 Operation .........................................................................................................................................................E-4
5 Operating Modes.............................................................................................................................................E-5
6 Adjustment of Heating Operation..................................................................................................................E-5
7 DHW Heating ...................................................................................................................................................E-6
7.1 Shut-Off times for DHW Preparation .............................................................................................................................................E-6
7.2 Thermal Disinfection......................................................................................................................................................................E-6
8 Menu Structure................................................................................................................................................E-7
8.1 Settings..........................................................................................................................................................................................E-7
8.2 Operating Data ............................................................................................................................................................................E-10
8.3 History..........................................................................................................................................................................................E-12
9 Displays .........................................................................................................................................................E-13
9.1 Normal Operating Statuses .........................................................................................................................................................E-13
9.2 Fault Messages ...........................................................................................................................................................................E-14

E-2
English
2
1 General Information
For installation, operation and maintenance refer to the
installation and operating instructions. This device should only be
installed and repaired by a competent technician. Poorly carried
out repairs can endanger the safety of the user. According to
current regulations, the installation and operating instructions
must always be available and should be handed to the technician
working on the device for his/her information. Therefore, we
request that these installation and operating instructions be
passed on to the new tenant or owner when there is a change in
occupancy. Do not connect the device if it is visibly damaged. In
this event, ask the supplier for advice. Ensure that only original
spare parts are used to prevent consequential damage. All
environmentally-relevant requirements regarding the recovery,
recycling and disposal of materials and components should be
observed in accordance with the applicable standards.
Regulations and Safety Information!
Any adjustments to the settings within the device may only
be carried out by an authorised technician.
The heat pump manager should only be operated in dry
rooms with temperatures ranging between 0 °C and 35 °C.
Ensure that no condensation forms on the device.
To ensure that the antifreeze function of the heat pump
works properly, the heat pump manager must remain
connected to the power supply and the flow must be
maintained through the heat pump at all times.
2 Heat Pump Manager
The heat pump manager is essential for operation of air-to-water,
brine-to-water and water-to-water heat pumps. It regulates a
bivalent, monovalent or mono energy heating system and
monitors the safety components in the refrigerating circuit. The
heat pump manager is either installed in the heat pump casing or
is delivered with the heat pump as a wall-mounted controller. It
carries out regulation of both the heating system (radiators and
circulation pump) and the heat source system.
Overview of functions
Convenient 6-button operation
Large and clear illuminated LC display with indicators for
operating status and service information
Conforms with utility company requirements
Dynamic menu navigation, customised for the configured
heat pump system
Remote control interface with identical menu navigation
Return temperature-controlled regulation of heating
operation based on external temperature, adjustable fixed-
setpoint or room temperature
Control of up to 3 heating circuits
Priority switching
– Cooling first
– DHW preparation first
– Heating first
– Swimming pool
Control of a 2nd heat generator
(oil or gas boiler, or immersion heater)
Control of a mixer for a 2nd heat generator (oil, gas, solid
fuel boiler, or regenerative heat source)
Special program for a 2nd heat generator to ensure
minimum runtimes (oil boiler) or minimum heating times
(main cylinder)
Control of a flange heater for targeted reheating of domestic
hot water with adjustable time programs, and for thermal
disinfection
Optional control of up to 5 circulating pumps
Defrost management system to minimise the energy
required for defrosting using variable, self-adjusting
defrosting cycle times
Compressor management system to ensure balanced
loading of the compressors for heat pumps with two
compressors
Operating hours counter for compressors, circulating
pumps, 2nd heat generator and flange heater
Keyboard block, child lock
Alarm memory with time and date
Interface for communication via PC with optional display of
heat pump parameters
Automatic program for targeted heat drying of screed floors
and saving the start and finish times

E-3
English
3
3 Quick Reference Instructions
3.1 Selection of the Operating Mode
3.2 Changing the Settings
Hold MENUE button depressed for several seconds
Select the desired menu item with the arrow buttons (⇑and
⇓)
Confirm by pressing the ENTER button (↵)
Select the desired submenu item with the arrow buttons (⇑
and ⇓)
Confirm with the ENTER button (↵) until cursor jumps to the
setting
Change the setting to the desired value with the arrow
buttons (⇑and ⇓)
Confirm new value with the ENTER button (↵) or revoke with
the ESC button
3.3 Settings and Operating Data
Menu for setting system-specific parameters (see Chap. 8 on p.
7). Dynamic menus hide non-essential settings.
Heating characteristic curves (see Chap. 6 on p. 5)
The heating characteristic curve can be adjusted to individual
temperature requirements using the Warmer/colder buttons on
the main display. Increase or reduce the temperature with the ⇑/
⇓buttons. For heating circuit 2/3, make this setting in the menu
“Heating circuit 2/ Heating circuit 3”.
DHW heating (see Chap. 7 on p. 6)
In addition to the hot water temperature, a shut-off-time for the
DHW heating can be set in the menu item “Settings – Domestic
hot water”. This can be used to switch DHW preparation e.g. to
the night hours. There is also the option of time-controlled
reheating of domestic hot water using a flange heater.
Operating data menu (see Chap. 8.2 on p. 10)
Display of measured sensor values
History menu (see Chap. 8.3 on p. 12)
Display of runtimes and stored data (e.g. faults)
Displays (see Chap. 9 on p. 13)
Select the desired operating mode by repeatedly pressing the modus button (text message). The operating mode will change 10
seconds after altering the setting (symbol changes on the display).
Cooling The system operates in cooling operation.
Summer Domestic hot water heating and swimming pool water heating only. Antifreeze (frost protection) is ensured.
Auto Programmed raising and lowering times are automatically activated.
Vacation Temperature reduction and domestic hot water block for an adjustable time period.
Party A programmed lowering of the heating characteristic curves is overridden.
2nd heat generator Heat pump is blocked. Heat is generated using the 2nd heat generator.
Time Sets the time and activates an automatic
summer/winter changeover.
Operation Various operating mode settings available
(see “Changing the Settings” on p. 3)
Heating circuit 1 Settings for heating circuit 1
Heating circuit 2 Settings for heating circuit 2
Heating circuit 3 Settings for heating circuit 3
Cooling Settings for cooling operation
DHW Settings for DHW preparation
Swimming pool Settings for swimming pool heating
Date Sets the date
(required for leap years only)
Language Sets the language desired
for menu navigation
Display of the current operating status of the heat pump
system
Fault messages: (ESC button flashes)
- HP fault Indication of a fault in the heat pump.
Inform your after-sales service.
- Plant fault Indication of a fault or an incorrect
setting in the system. Inform your local
technician.
- Short-circ.
or break
This can be caused by a breakage or a
sensor which is short circuiting. Inform
your local technician.

E-4
English
4
4 Operation
The heat pump manager is operated using 6 pushbuttons:
Esc, Modus, Menue, ⇓, ⇑, ↵. Different functions are assigned
to these buttons according to the current display (Standard
or Menu).
The operating status of the heat pump and the heating
system is indicated in plain text on a 4 x 20 character LC
display (see Chap. 9 on p. 13).
6 different operating modes can be selected:
Cooling, Summer, Auto, Party, Vacation, 2nd heat
generator.
The menu consists of 3 main levels:
Settings, Operating data, History
(see Chap. 6 on p. 5)
Fig. 4.1: Standard LC display - main display with operator buttons
NOTE
Contrast:
The display can be adjusted for contrast. Do this by depressing the
buttons (MENUE) and (↵) at the same time until adjustment process has
been completed.
Increase the contrast by simultaneously pressing the button (×). Reduce
the contrast by pressing the button (Ø).
NOTE
Keyboard block, child lock!
To prevent unintentional adjustment of the heat pump manager, press the
button (Esc) for approx. 5 seconds until KEY BLOCK ACTIVE appears on
the display. Cancel the keyboard block using the same procedure.
Tab. 4.1: Operator button functions
FKDUDFWHUGLVSOD\
ZLWKEDFNOLJKWLQJ
2SHUDWLQJPRGH
V\PEROV
&RQWURONH\V
+3VWDWXVGLVSOD\
OLQHV
+HDWLQJZDUPHUFROGHU
3URJUHVVEDUOLQH
Button Standard display (Fig. 4.1 on p. 4)Change of setting (Chap. 8 on p. 7)
Esc Activates or deactivates the keyboard block
Acknowledges a fault
Exits the menu and returns to the main display
Returns from a submenu
Exits a setting without saving changes
Modus Selects the operating mode (see Chap. 5 on p. 5)No action
Menue Jumps to menu No action
⇓Shifts the heating curve downwards (colder) Scrolls downwards between menu items on one level
Changes a setting in a downward direction
⇑Shifts the heating curve upwards (warmer) Scrolls upwards between menu items on one level
Changes a setting in an upwards direction
↵No action Selects a setting in the corresponding menu item
Exits a setting and saves changes
Jumps to a submenu

E-5
English
5
5 Operating Modes
6 different operating modes can be selected using the button
(Modus). There is a time delay between switching modes. The
operating mode can be changed each time the button is pressed
in the order shown below.
NOTE
Heat pump operation block
The heat pump is blocked in the 2nd heat generator operating mode.
Heating operation and DHW preparation in mono energy systems is
carried out using electric heating elements. In the case of bivalent
systems, the 2nd heat generator is used.
6 Adjustment of Heating Operation
During start-up, the heating characteristic curve is adjusted to
suit the building and local conditions. This heating characteristic
curve can be adjusted to individual temperature requirements
using the Warmer/colder arrow buttons on the main display.
Increase the temperature with the ⇑button. The indicator bar in
the last line will move to the right.
Decrease the temperature with the ⇓button. The indicator bar in
the last line will move to the left.
For heating circuits 2/3, make this setting in the “Heating circuit
2/ 3” menu.
The set heating characteristic curves can be lowered or raised on
a time-controlled basis. For example, in poorly insulated
buildings the heating characteristic curve can be lowered, or
raised before the shut-off time to prevent significant cooling of
the heating surfaces.
If the raising and lowering operations overlap each other, the
raising operation has priority.
NOTE
Energy-Efficient Operation
For energy-efficient operation of the heat pump heating system, the
temperature level to be generated by the heat pump should be as low as
possible.
In well-insulated buildings, constant heating operation without lowering
times will normally result in lower energy costs. This is because power
peaks with high flow temperatures are avoided and the same degree of
comfort is attained at lower temperatures.
Shut-off times can be compensated for by a temperature rise that begins
1 hour before the shut-off time takes effect.
COOLING
Selectable only when the
cooling controller is
connected
(see Installation and
Start-up)
The system operates in cooling operation. The individual control functions are active. This
operating mode can only be activated if a cooling controller is connected to the heat pump
manager and the cooling function has been enabled in the preconfiguration.
SUMMER Only domestic hot water and swimming pool water are heated up in the SUMMER operating
mode. Space heating is not activated. Antifreeze (frost protection) is ensured.
AUTO The heat pump operates in automatic operation. Programmed lowering times, raising times and
shut-off-times for heating and DHW heating are activated automatically. DHW heating, heating
and swimming pool heating are activated according to priority. The heat pump and the 2nd heat
generator are switched on or off as required.
VACATION
(lower operation)
A lowering of the heating characteristic curves and a hot water block are activated in the
VACATION operating mode. Both functions are independent of any relevant timings, but the
lower values set for these functions still apply. The duration of the VACATION operating mode
can be set in the menu “1 Settings – Operation – Vacation mode”. After this time period has
elapsed, the system switches automatically back to automatic operation again.
PARTY
(daytime operation)
A programmed lowering of the heating characteristic curves is overridden in the PARTY operating
mode. The duration of the PARTY operating mode can be set in the menu “1 Settings –
Operation – Party mode”. After this time period has elapsed, the system switches automatically
back to automatic operation again.
2nd heat generator
(HG2)
The heat pump is switched off in this operating mode and the entire heat supply is provided by
the 2nd heat generator (HG2). This is the immersion heater in mono energy systems. In bivalent
systems it is the oil or gas heating. Time programs and heating curve settings remain active.

E-6
English
7.2
7 DHW Heating
The heat pump manager automatically calculates the maximum
possible hot water temperature in heat pump operation. The
desired hot water temperature can be set in the menu “Settings
– Domestic hot water – Hot water set temp”.
Hot water temperature - HP maximum
To attain the highest possible heat pump ratio during DHW
preparation, the controller automatically calculates the maximum
possible hot water temperature in heat pump operation based on
the current heat source temperature. The lower the heat source
temperature (e.g. external temperature, brine temperature), the
higher the attainable hot water temperature.
Hot water cylinder without flange heater
If the hot water set temperature exceeds the maximum attainable
hot water temperature in heat pump operation, DHW preparation
is terminated once the so-called HP maximum temperature is
reached.
Hot water cylinder with flange heater
If the hot water set temperature exceeds the maximum attainable
hot water temperature in heat pump operation, DHW preparation
with the heat pump is terminated once the so-called HP
maximum temperature is reached, and the desired hot water
temperature is attained by reheating using the flange heater.
NOTE
Reheating with flange heater
After DHW preparation with the heat pump, the water can be further
heated to higher temperatures if the system is provided with a flange
heater. DHW heating does not take place again until the HP maximum
temperature is undershot. This ensures that basic heating can be carried
out by the heat pump.
7.1 Shut-Off times for DHW Preparation
In addition to the hot water temperature, shut-off-times for DHW
heating can also be programmed in the menu item “Settings –
Domestic hot water –Hot water block“. No DHW heating is
carried out during this period.
If a sufficiently large cylinder is available, we recommend
carrying out DHW heating or reheating during the night-time
hours. This means that the more favourable low tariff periods
normally available can be utilized.
7.2 Thermal Disinfection
In the menu item “Settings – Domestic hot water – Therm.
Desinfection”, it is possible to carry out a thermal disinfection
with hot water temperatures of up to 85 °C in bivalent systems or
systems with hot water cylinders and integral flange heaters. The
thermal disinfection can be carried out for each day of the week.
The start time is selectable.

E-7
English
8
8 Menu Structure
8.1 Settings
All user settings are made in the “Settings” menu item.
The following table shows not only the menu structure and
explanations in the right-hand column, but also the
corresponding setting ranges. Values in bold print indicate the
factory settings.
You can access the settings menu by:
Pressing the button (MENUE) for approx. 5 seconds
Confirming the settings menu item with the ENTER button.
NOTE
Dynamic menus
The following contains a description of the complete menu. During start-
up, the regulatory functions and the menu structure are adjusted to the
specific system. Non-relevant menu items are then hidden according to
these settings.
Example: Settings for DHW preparation can only be made if the “DHW
preparation” menu item is configured with “Yes” in the preconfiguration.
Abbreviations:
HG2 = 2nd heat generator (e.g. boiler)
System-specific parameters Setting range
Menu for setting the time. An automatic changeover from daylight
saving time (summer) to winter time can be selected.
International 24 h
display
Level for setting operating modes
Selects the operating mode
It is also possible to make changes directly using the modus
button.
Cooling
Summer
Auto
Party
Vacation
HG2
Duration of party mode in hours
After the set period has elapsed, the system returns automatically
back to automatic operation again.
0
... 4...
72
Duration of vacation mode in days
After the set period has elapsed, the system returns automatically
back to automatic operation again.
0
... 15 ...
150
Settings for heating circuit 1
Sets the desired room set temperature when room temperature
regulation is selected
15.0 °C
... 20.0 °C ...
30.0 °C
Settings to lower the heating characteristic curve of heating
circuit 1
Sets the time during which the temperature in heating circuit 1 is to
be lowered
00:00
...
23:59
Sets the temperature value by which the heating characteristic
curve of heating circuit 1 is to be lowered when the temperature is
lowered
0 K
...
19 K
For each day of the week, it is possible to select whether Time1,
Time2, no time or both times are to be active when the
temperature is lowered. Operations to lower the temperature that
exceed a week day are activated or deactivated at the end of each
day accordingly.
N
T1
T2
Y
Settings to raise the heating characteristic curve of heating circuit
1
Sets the time during which the temperature in heating circuit 1 is to
be raised.
00:00
...
23:59
Sets the temperature value by which the heating characteristic
curve of heating circuit is to be raised when the temperature is
raised.
0 K
...
19 K

E-8
English
8.1
For each day of the week, it is possible to select whether Time1,
Time2, no time or both times are to be active when the
temperature is raised. Operations to raise the temperature that
exceed a week day are activated or deactivated at the end of each
day accordingly.
N
T1
T2
Y
Settings for heating circuit 2/3
Parallel shift of the set heating curve for heating circuit 2/3. By
pressing the arrow buttons once, the heating curve is shifted by
1°C upwards (warmer) or downwards (colder).
Indicator bar
Settings to lower the heating characteristic curve of heating circuit
2/3
Sets the time during which the temperature in heating circuit 2/3 is
to be lowered.
00:00
...
23:59
Sets the temperature value by which the heating characteristic
curve of heating circuit 2/3 is to be lowered when the temperature
is lowered
0 K
...
19 K
For each day of the week, it is possible to select whether Time1,
Time2, no time or both times are to be active when the
temperature is lowered. Operations to lower the temperature that
exceed a week day are activated or deactivated at the end of each
day accordingly.
N
T1
T2
Y
All settings to raise the heating characteristic curve of heating
circuit 2/3
Sets the time during which the temperature in heating circuit 2/3 is
to be raised.
00:00
...
23:59
Sets the temperature value by which the heating characteristic
curve of heating circuit 2/3 is to be raised when the temperature is
raised.
0 K
...
19 K
For each day of the week, it is possible to select whether Time1,
Time2, no time or both times are to be active when the
temperature is raised. Operations to raise the temperature that
exceed a week day are activated or deactivated at the end of each
day accordingly.
N
T1
T2
Y
Settings for cooling operation
Sets the desired return set temperature when dynamic cooling is
selected
10 °C
... 15 °C ...
30 °C
Sets the room set temperature for silent cooling
The actual value is measured by room climate control station 1
15.0 °C
... 20.0 °C ...
30.0 °C
Sets the DHW preparation
Sets the desired hot water temperature 30 °C
... 45 °C ...
85 °C
Sets the time programs for hot water blocks
Sets the times in which DHW preparation is blocked 00:00
...
23:59
For each day of the week, it is possible to select whether Time1,
Time2, no time or both times are to be active when the
temperature is lowered. Operations to lower the temperature that
exceed a week day are activated or deactivated at the end of each
day accordingly.
N
T1
T2
Y
System-specific parameters Setting range

E-9
English
8.1
To carry out a thermal disinfection, the DHW is heated up once to
the desired temperature. The heating period is terminated
automatically when the set temperature is reached or after 4 hours
at the latest.
Sets the start time for the thermal disinfection 00:00
...
23:59
Sets the desired hot water temperature which is to be reached
during thermal disinfection
60 °C
... 45 °C ...
85 °C
For each day of the week, it is possible to select whether thermal
disinfection is desired at the set start time.
N
Y
By setting Reset to “Yes”, the maximum calculated hot water
temperatures in HP operation are reset to a value of 65 °C. The
setting is automatically reset to “No”.
No
Yes
Sets the preparation of swimming pool water
Sets the time programs for swimming pool blocks
Sets the times in which swimming pool water preparation is
blocked
00:00
...
23:59
For each day of the week, it is possible to select whether Time1,
Time2, no time or both times are to be active when the
temperature is lowered. Operations to lower the temperature that
exceed a week day are activated or deactivated at the end of each
day accordingly.
N
T1
T2
Y
Sets the date, year, day, month and week day
The language for menu navigation can be selected from the
available languages
DEUTSCH
ENGLISH
FRANCAIS
ITALIANO
NEDERLAND
CESKY
System-specific parameters Setting range

E-10
English
8.2
8.2 Operating Data
All current operating statuses are displayed in the “Operating
data” menu item.
You can access the operating data menu by:
Pressing the button (MENUE) for approx. 5 seconds
Selecting the operating data menu item with the arrow
buttons and confirming with the ENTER button
Depending on the system configuration, the following data can
be queried in the “Operating data” menu:
Display of sensor and system values Display
The external temperature is used for calculating the return set
temperature, for antifreeze functions and for defrosting
At all times
Displays the calculated return set temperature for heating circuit 1 Not with silent
cooling only with
reversible HP
Displays the return temperature of heating circuit 1 measured on
the sensor. This temperature is the controlled variable for heating
circuit 1.
At all times
Displays the flow temperature measured on the sensor. This
temperature is used for antifreeze functions and for safeguarding
defrosting.
Air HP or sensor
connected
Displays the calculated set temperature for heating circuit 2 Heating circuit 2
Heating operation
Displays the minimum temperature possible with silent cooling,
calculated from the dew point plus dew point distance
Cooling operation
Silent cooling
only, reversible
HP
or HC2
Displays the temperature of heating circuit 2 measured on the
sensor.
This temperature is, among other things, the controlled variable for
heating circuit 2.
HC2 or
cooling operating
with silent cooling
only with
reversible HP
Displays the calculated set temperature for heating circuit 3 Heating circuit 3
Heating operation
Displays the temperature of heating circuit 3 measured on the
sensor. This temperature is the controlled variable for heating
circuit 3.
Heating circuit 3
Heating operation
Indicates if a request for heating has been made. Even if there is a
request for heating, it is possible that the heat pump will not
operate (e.g. because of the utility company shut-off time).
“Heating system flushing” is displayed when the system is being
flushed.
An HP block combined with a sufficiently high cylinder temperature
is indicated by “Bivalent-regen.”.
Min. 1 heating
circuit
Indicates which heat generator is available to carry out the heating
request
1: max. 1 compressor, 2: max. 2 compressors, 3: max. 2
compressors and a 2nd heat generator
Heating operation
Sensor for determining the defrost end with hot gas defrosting Air HP with hot
gas defrosting
Displays the temperature measured in the cylinder in bivalent-
regenerative systems
Bivalent-
regenerative
Displays the measured return temperature during cooling
operation measured at the heat exchanger input
Passive cooling
function
Cooling operation
Displays the measured flow temperature during cooling operation
measured at the heat exchanger output
Passive
cooling function

E-11
English
8.2
NOTE
Heating request
A heating request is pending if the “Return set temperature” minus the
“Hysteresis return temperature” is higher than the currently measured
“Return temperature”.
Displays the temperature measured on the “Antifreeze Cool”
sensor.
This temperature is used to safeguard the operating limits in
cooling operation.
Reversible HP
Cooling operation
Displays the current room set temperature with silent cooling. Cooling function
Silent cooling
Cooling operation
Displays the temperature measured in the room in which room
climate control station 1 is installed.
This temperature is the controlled variable for silent cooling.
Cooling function
Silent cooling
or
reference room
Displays the humidity measured in the room in which room climate
control station 1 is installed. This value is used for calculating the
dew point with silent cooling.
Cooling function
Silent cooling
Displays the temperature measured in the room in which room
climate control station 2 is installed.
This value is used for calculating the dew point with silent cooling.
Cooling function
Silent cooling
2 room stations
Displays the actual humidity in the room in which room climate
control station 2 is installed. This value is used for calculating the
dew point with silent cooling.
Cooling function
Silent cooling
2 room stations
Indicates if a request for cooling has been made Cooling function
Cooling operation
Displays the current hot water set temperature Domestic hot
water
Sensor
Displays the measured hot water temperature. This temperature is
the controlled variable for DHW preparation.
Domestic hot
water
Sensor
Indicates if a request for domestic hot water has been made. Even
if there is a request for hot water, it is possible that the heat pump
will not operate (e.g. because of the utility company shut-off time).
An HP block combined with a sufficiently high cylinder temperature
is indicated by “Bivalent-regen.”.
Domestic hot
water
Indicates if a request for swimming pool water has been made.
Even if there is a request for swimming pool water, it is possible
that the heat pump will not operate (e.g. because of the utility
company shut-off time). An HP block combined with a sufficiently
high cylinder temperature is indicated by “Bivalent-regen.”.
Swimming pool
Displays the temperature measured at the heat source output or
the refrigerating circuit output of the HP. This temperature serves
to safeguard the lower operating limit.
BW or WW HP
with integr.
controller
Displays the heat pump type identified from the coding resistor. At all times
Displays the heating controller software version including the boot
and bios version, as well as the valid network address.
At all times
Displays the cooling controller software version including the boot
and bios version, as well as the valid network address.
Cooling function
Displays whether a cooling controller is available in the network
(Contr. Cooling) and whether the network is operating correctly
(Network O.K.).
Cooling function
Display of sensor and system values Display

E-12
English
8.3
8.3 History
The “History” menu can be used to query the runtimes of the
compressor(s), circulating pumps and further components in the
heat pump heating system.
You can access the history menu by:
Pressing the button (MENUE) for approx. 5 seconds
Selecting the history menu item with the arrow buttons and
confirming with the ENTER button
Depending on the system configuration, the following data is
available:
Display of runtimes and stored data Display
Total runtime of compressor 1 At all times
Total runtime of compressor 2 Compressor 2
Total runtime of compressor 2 Bivalent or mono
energy
Total runtime of the brine circulating pump or well pump. The
runtime is greater than the total of the compressor runtimes
because of pump forerun and afterun.
BW or WW HP
Total runtime of the ventilator. The runtime is less than the total of
the compressor runtimes because of the defrosting process (the
ventilator is switched off during defrosting).
AW HP
Total runtime of the heat circulating pump At all times
Runtime of the compressor in cooling operation Reversible HP
Total runtime of the hot water circulating pump Domestic hot
water
Total runtime of the swimming pool circulating pump Swimming pool
Runtime during which the flange heater was additionally switched
on for DHW preparation
Domestic hot
water
Sensor
Immersion heater
Displays the last fault which occurred with the date, time and
cause
At all times
Displays the second to the last fault which occurred with the date,
time and cause
At all times
Displays the start and end of the last, fully completed initial heating
program
At all times
Displays the start and end of the last, fully completed screed drying
program
At all times

E-13
English
9
9Displays
The current operating status of the heat pump system can be
read from the LC display.
9.1 Normal Operating Statuses
The display shows both normal operating statuses and those that
are required by utility companies or due to safety functions of the
heat pump. Only information about the relevant system
configuration and HP type are shown on the display.
Heat pump does not operate because there is no request for heating pending.
Heat pump operates in heating operation
Heat pump operates with active cooling
Heat pump operates for DHW preparation and heats the hot water cylinder
Heat pump operates and heats the swimming pool water
Heat pump and 2nd heat generator operate in heating operation
Heat pump and 2nd heat generator operate and heat the swimming pool water
Heat pump and 2nd heat generator operate in DHW heating operation and heat the hot water
cylinder
After expiry of the minimum pause time, the heat pump will start in order to meet the heating
request that is pending. The minimum pause time protects the heat pump and can last up to 5
minutes.
After expiry of the switch cycle block, the heat pump will start in order to meet the heating request
that is pending. The switch cycle block is required by utility companies and can last up to 20
minutes. A maximum of 3 switch-ons per hour are permissible.
After expiry of the switch-on delay for the line load, the heat pump will start in order to meet the
heating request that is pending. The switch-on delay for the line load is required by utility
companies after the voltage is recovered or after a utility block. It can last up to 200 seconds.
The heat pump starts after expiry of the utility company shut-off time. The utility company shut-off
time is specified by the utility company and lasts up to two hours depending on the utility company.
Activation or deactivation is carried out by the utility company.
The heat pump was switched off by an external utility blocking signal on input ID4.
The heat pump starts after completion of the primary pump forerun. This can last up to 3 minutes
(safety function).
The heat pump was switched off because the low pressure limit was reached. The heat pump will
switch on again automatically. The 2nd heat generator (HG2) undertakes the supply of heat until
the heat pump switches on again automatically.
The heat pump was switched off because the low pressure limit was reached. The heat pump will
switch on again automatically. The 2nd heat generator (HG2) undertakes the supply of heat until
the heat pump switches on again automatically.
The heat pump was switched off because the lower operating limit was reached. The heat pump
will switch on again automatically as soon as the heat source temperature has reached a sufficient
level (safety function).
The heat pump was switched off because the high pressure limit was reached. It will switch on
again automatically (high pressure safety program).
The heat pump cannot start because of the operating temperature limit. The external air
temperature is less than –15 °C or –20 °C, or higher than 35 °C (safety function). Or the heat pump
was blocked by the “Bivalent-alternative” setting, because the external temperature is lower than
the limit temperature.
The heat pump is switched off because the operating mode, 2nd heat generator (HG2) was
selected. Heat generation is provided by the 2nd heat generator.
Flow rate monitoring of the heating water takes place before the evaporator is defrosted. This
applies to air-to-water heat pumps only. This process lasts a maximum of 4 minutes.
The heat pump defrosts the evaporator. This process lasts a maximum of 8 minutes.
The maximum return temperature was overshot. Once the temperature drops, the HP will start
again automatically.
Switching to and from the cooling operating mode activates a time delay of 5 minutes. The heat
pump remains switched off during this period.

E-14
English
9.2
9.2 Fault Messages
Fault Messages on the display fall into three broad categories:
Heat pump fault
Plant fault and
Sensor fault
You only need to inform your after-sales service if there is a heat
pump fault (HP fault). Make a note of the error message and the
software version displayed in the operating data. After rectifying
the problem, press the Esc button to acknowledge the fault.
The following messages may appear on the display.
NOTE
Plant fault
In mono energy systems, the minimum return set temperature is set if a
heat pump or plant fault occurs. Antifreeze (frost protection) is ensured.
By manually switching to the 2nd heat generator operating mode, the
building is heated exclusively using the immersion heater.
Despite a pending request, the chiller is unable to cool because antifreeze (frost protection) was
activated. This state is ended automatically.
Despite a pending request, the chiller is unable to cool because the current flow temperature is
under the operating limit. This state is ended automatically.
Despite a pending request, the chiller is unable to cool because the dew point monitor has been
activated (external input). This state is ended automatically.
Despite a pending request, the chiller is unable to cool because the dew point calculated from the
sensor values from the room climate control stations has been undershot. This state is ended
automatically.
The heat pump operates in passive cooling and no requests are pending.
A heat pump fault indicates a defect in the heat pump. Inform your after-sales service. Details
of the fault (display), the heat pump designation (type plate) and the software version of the heat
pump manager (operating data) are required for rapid and precise troubleshooting. Depending on
the system type, the following heat pump faults may appear on the display:
Low pressure
Hot gas thermostat
Antifreeze
Temp. difference
Motor prot.compr
A plant fault indicates a defect or a false setting in the heat pump system. Inform your local
technician. Details of the fault, the heat pump designation and the software version of the
controller are required for rapid and precise troubleshooting. Depending on the system type, the
following plant faults may appear on the display:
Motor prot. Primary
Flow rate well
High pressure
As with a plant fault, this can be caused by a breakage or a sensor which is short circuiting. Inform
your local technician. Details of the fault, the heat pump designation and the software version of
the controller are required for rapid and precise troubleshooting. Depending on the system type,
the following sensors may be defective:
Return flow sensor
Flow temperature limit sensor
Hot water sensor
Flow sensor
2./3. Sensor for heating circuit 2/3
External sensor

Garantiebedingungen und Kundendienstadresse siehe
Montage- und Gebrauchsanweisung Wärmepumpe.
For the terms of the guarantee and after-sales service
addresses, please refer to the Installation and Operating
Instructions for Heat Pumps.
Pour les conditions de garantie et les adresses SAV, se référer
aux instructions de montage et d'utilisation de la pompe à
chaleur.
Irrtümer und Änderungen vorbehalten.
Subject to alterations and errors.
Sous réserve d’erreurs et modifications.

1. Key assignment
Change the operating mode by pushing the key once or repeatedly:
The filled square in the upper right corner of the display indicates the current operating mode.
Symbol Operating mode Denotation
Auto Fully automatic control of the entire heat pump
heating system
Vacation Temperature lowering and hot water block
for an adjustable time period (in days)
Party For overriding programmed temperature lowering
for an adjustable time period (in hours)
Heat generator 2 Heat pump blocking;
Heating and domestic hot water preparation through the second
heat source (e.g.oil heater) or the electric heating elements
Summer Domestic hot water and swimming pool water preparation;
Heating operation blocked
Cooling Cooling operation cannot be activated on all
heat pumps
The heat pump manager is operated using 6 keys:
Modus
Confirm changes to settings (Enter key).
Press the key once to increase the heating temperature by 1 °C.
The indicator bar will move to the right.
Press the key once to reduce the heating temperature by 1 °C.
The indicator bar will move to the left.
2. Settings menus
Jump to the menu to modify Settings.
Jump to other setting options.
Confirm the menu item Settings to go to the submenus.
Briefly touch
Briefly touch
Briefly touch
Briefly touch
Keep pressed
for 2 seconds
Briefly touch
Briefly touch
Keep pressed
for 1 second Jump back to a higher menu level.
How to adapt the settings to your requirements:
Menue
ESC
ESC
Jump back to a higher menu level.Briefly touch
Keep pressed
for 3 seconds
Keep pressed
for 5 seconds Activate and deactivate the keylock.
Jump back to the standard display.
Menue
Jump to the menu to modify Settings.
Keep pressed
for 2 seconds
When the key is pressed, the selected operating mode will be shown as text in the display.
The selected operating mode will be activated after approx. 10 seconds.
or
Quick Reference Instructions
WPM 2006 plus
WPM 2006 R
WPM 2007 plus
WPM 2007 R
Note: These quick reference instructions do not replace the enclosed operating instructions, which can also be downloaded from the Internet.

Quick Reference Instructions
3. Domestic hot water preparation
WPM 2006 plus
WPM 2006 R
WPM 2007 plus
WPM 2007 R
How to set the domestic hot water temperature and the hot water block:
ESC
Jump back to the standard display.
Menue
Confirm the selection of the menu item Settings.
Jump to the menu to modify Settings.
Keep pressed
for 3 seconds
Briefly touch
Keep pressed
for 2 seconds
Press the key several times to select the menu item Domestic hot water.Briefly touch
Confirm selection of the menu item Domestic hot water.Briefly touch
Confirm selection of the menu item Hot water set temp.Briefly touch
Increase or lower the hot water set temperature as required.Briefly touch
or
Confirm the set value.Briefly touch
Select the menu item Hot water block.Briefly touch
Confirm selection of the menu item Hot water block.Briefly touch
Jump to the setting to start the Hot water block (Time).Briefly touch
Increase or lower the setting as required.Briefly touch
or
Jump to the other settings until the cursor flashes in the upper corner.
Example: Time 1: 06:00-22:00 will block domestic hot water preparation from 6:00 am to 10:00 pm.
Briefly touch
repeatedly
Select the menu item Hot water block (Mo-Su).Briefly touch
Jump to the individual weekdays from Monday to Sunday.
Briefly touch
repeatedly
Select one or both shut-off times per weekday and confirm by pressing the Enter key:
N: No shut-off time active
T1: Time 1 active as shut-off time
T2: Time 2 active as shut-off time
Y: Time 1 and Time 2 active as shut-off times
Example: SA: N and SU: N will prevent hot water block at weekends.
Briefly touch
or
How to return to the standard screen
and what to do if you have any problems making settings:
Briefly touch
Other manuals for WPM 2006 plus
2
This manual suits for next models
3
Table of contents
Other Dimplex Network Router manuals
Popular Network Router manuals by other brands

Asus
Asus REPUBLIC OF GAMERS GT-AX6000 user manual

D-Link
D-Link DIR-600L Quick installation guide

TRENDnet
TRENDnet TW100-BRV204 SHEETS Specifications

Elsner
Elsner KNX CP IP Installation and adjustment

ZyXEL Communications
ZyXEL Communications Unified Security Gateway ZyWALL 300 Specifications

Advantech
Advantech SmartFlex SR307 user manual