This brief instruction of mounting the
FlexxPump 250 / 400 time addresses to experienced users.
Please visit www.dls-schmiersysteme.de to download the
complete user manual including all safety instructions.
1. Overview FlexxPump 250/400 time
No. Description
0 FlexxPump 250 / 400 time
1 LCD
2 Action area (for actions with the activation and
programming key)
3 Activation and programming key
4 Lubricant outlet(s) (different versions available)
5 Retaining ring
6 Housing (different versions available)
7 M12x1 electrical interface
8 Nameplate with designation, CE mark and serial number
9 Clearance hole for assembly
10 Lubricant inlet with thread for cartridge
2. Technical data
Housing
Mounting options holes for screw M6
Mounting position any
Operating temperature -10 till +60* °C
Lubricant and hydraulic
Lubricant outlets 1 / 2
Max. Pressure 70 bar / 1015 psi (-10%/+15%)
Steady state pressure 70 bar / 1015 psi
Cartridge volume 250 / 400 ml
Grease delivery per Stroke 0,15 cm³
Electrics
Operating voltage 24 (20...28) V
Protection 0,75 (slow blow) A
Protection class IP 54
*The stated value is down to the individual application and may extensively
differ in some cases (depending on the lubricant and further conditions).
3. Mounting
1. Separate the housing from the power unit by turning the retai-
ning ring counterclockwise.
2. Turn the cap on the lubricant cartridge counterclockwise and
pull it off .
3. Place the full lubricant cartridge on the
FlexxPump 250 / 400 time (label facing front). Turn the lubricant
cartridge twice clockwise onto the FlexxPump 250 / 400 time.
4. Place the dismantled housing on the FlexxPump 250 / 400 time.
Fasten the housing to the power unit by turning the retaining
ring clockwise.
5. To connect the FlexxPump 250 / 400 time with an external
power supply system add a proper connecting cable to the
electrical interface on the side of the FlexxPump 250 / 400 time.
DANGER
Damaged or flawed electrical connections or unlicensed hot
components lead to heavy injuries or even death.
4. Commissioning
1. Mechanical fastening
Fix the FlexxPump 250 / 400 time mechanically. Pay particular atten-
tion to the maximum tightening torques permissible!
2. Electrical connection
3. Power on
4. Execute FIL function
5. Hydraulic connection
Connect the consumer hydraulically to the FlexxPump 250 / 400
time. If you connect tubes to the FlexxPump 250 / 400 time make
sure that tubes and connectors are installed tightly, cleanly and
correctly.
Ideally, use tubes prelled with the appropriate lubricant.
6. Check settings on the FlexxPump 250 / 400 time
Check the required values for the lubrication point at the factory set-
tings of the FlexxPump 250 / 400 time and adjust them if necessary.
Factory settings: operating mode=hour mode.
5. Operation and settings
Two operating modes can be selected.
Thehourmode -h- allowssettingthenumberofcycles(c)withinabreak
time (h) in hours. The cycles are evenly distributed over the break time.
Breaktimesbetween1...240hour(s)andcycles between 1...30 can be set.
The empty time mode Et allows the emptying time of the cartridge
to be set in months. Emptying times between 1...36 month(s) and cyc-
les (c) between 1...30 can be set.
The graphic above illustrates the unchangeable basic flowchart of the
the FlexxPump 250 / 400 time menu navigation as well as the options
for branching to submenus.
The FlexxPump 250 / 400 time can be switched on and off at seve-
ral points in the menu navigation.
The INF-menu provides you with an informative overview of the
current the FlexxPump settings.
The SET menu allows you to make change the operating mode
and to adjust the size of the cartridge.
The RUN menu allows you to manually trigger a single dispense at
the FlexxPump 250 / 400 time.
The PRO menu allows you to make changes to the the FlexxPump
250 / 400 time settings - and thus to its dispensing behavior.
The FIL menu allows you to manually trigger a xed number of
dispenses at the FlexxPump 250 / 400 time.
0
5
4
2
3
6
8
1
9
10
7
Display in LCD Description
---- Received control signal longer than 15 seconds
Errors
E1 Error E1 (empty cartridge)
E2 Error E2 (overload / overpressure)
E3 Error E3 (undervoltage)
E4 Error E4 (fatal error)
Submenus
INF INF-Menü
n41 Firmware version of the FlexxPump 250 / 400 time
h03 Currently set value of break time h
c01 Currently set value of number of strokes c
06 Currently set value of emptying time Et
SET SET-Menü
-h- Operating mode: hour mode
Et Operating mode: empty time mode
250/400 Adjustment of the cartridge size
5.2 Menu and LCD messages
5.1 Default settings, hour mode -h-
Break time h = 3 The break time is 3 hours.
No. of cycles c = 1 The number of cycles is one (1) stroke during
break time.