DLS FlexxPump 250 User manual

QuickStart
FlexxPump 250 / 400 time
5.3 Actions with the activation and programming key
1. Turn the activation and programming
key to the OPEN position and remove it
from the housing of the FlexxPump
250 / 400.
2. Place the key on the action area on
the front of the FlexxPump 250 / 400 time.
3. Remove the key from the action
area as long as the desired menu item is
displayed in the LCD.
5.4 SET-menu
The SET menu allows you to change the operating mode and the
cartridge size of the FlexxPump 250 / 400 time. You can switch
between hour mode -h- and empty time mode Et
5.5 PRO menu
Being in operating mode hour mode -h-, you can change the break
time h as well as the number of cycles c (number of strokes).
Being in PRO menu the rst step is to set the break time h and after-
wards the number of cycles c; direct access to the number of cycles
c is not possible.
Running empty time mode Et, you can change the emptying time Et
in months.
5.6 FIL menu
This function enables you to prell connected accessories (tubes,
distributors,...) with the lubricant contained in the lubricant cartridge,
especially during the initial start-up. However, the process can also
be aborted manually at any time.
PIN assignment - time control
PIN Assignment Colour
1 +24 V DC brown
2 unallocated white
3 ground blue
4 output signal black
Type: M12x1 female connector; 4-pin, A-coded
The FlexxPump 250 / 400 time can be switched off completely by
switching off the supply voltage.
The output signal at PIN 4 can be tapped for further processing
(e.g. indicator light or external control). The maximum permissible
current output must not exceed Imax < 20mA. No inductive load
(e.g. relay) may be connected!
5.8 Input and output signals
LCD Description Output signal (PIN 4)
OFF switched off low, permanent
ON ready for operation high, permanent
E1 cartridge empty 0,5Hz square wave signal, permanent
E2 overload low, permanent
E3 undervoltage low, permanent
E4 fatal error low, permanent
 The FlexxPump 250 / 400 time does not process any control
signals until all errors have been eliminated.
 Error E2 (overload) must be acknowledged with switching the
pump off and on after elimination of the cause(s).
 Error E3 (undervoltage) must be acknowledged with switching
the pump off and on after elimination of the cause(s).
 IMPORTANT: There must be at least 60 sec. between switching
off and on!
6. Maintenance
Notice
It is not possible to rell empty or opened lubricant cartridges.
32
1
4
5.7 Input and output signals - time control
-h- Operating mode hour mode -h-
Et Operating mode Empty-time
125/250 Cartridge size
If you would like to change the operating mode, move the activation
and programming key back to the action area. When your desired
operating mode is displayed on the LCD, remove the activation and
programming key from the action area. If you would like to change
the cartridge size, act accordingly.
RUN RUN-Menü
01...70 During the manually triggered active RUN command („quick
check“/extra dispense), the LCD displays the approximate
back pressure in bar. In addition, the green LED lights up.
PRO PRO-Menü
h1...240 Adjustable setting of break time h
c1...30 Adjustbale setting of number of strokes c
01...36 Adjustabe setting of emptying time Et
FIL FIL-Menü
01...70 During the manually triggered, active FIL command, the LCD
displays the approximate back pressure in bar. In addition,
the green LED lights up.
Clr If the process is aborted during FIL command Clr appears
at rst.
Additional character on the LCD
1 / 2 During a dispensing process the FlexxPump 250 / 400 time
indicates from which outlet lubricant is being pumped.
MAX After each cycle the maximum back pressure is displayed in
bar.
Rev.: SG-20210914
This brief instruction of mounting the
FlexxPump 250 / 400 time addresses to experienced users.
Please visit www.dls-schmiersysteme.de to download the
complete user manual including all safety instructions.
1. Overview FlexxPump 250/400 time
No. Description
0 FlexxPump 250 / 400 time
1 LCD
2 Action area (for actions with the activation and
programming key)
3 Activation and programming key
4 Lubricant outlet(s) (different versions available)
5 Retaining ring
6 Housing (different versions available)
7 M12x1 electrical interface
8 Nameplate with designation, CE mark and serial number
9 Clearance hole for assembly
10 Lubricant inlet with thread for cartridge
2. Technical data
Housing
Mounting options holes for screw M6
Mounting position any
Operating temperature -10 till +60* °C
Lubricant and hydraulic
Lubricant outlets 1 / 2
Max. Pressure 70 bar / 1015 psi (-10%/+15%)
Steady state pressure 70 bar / 1015 psi
Cartridge volume 250 / 400 ml
Grease delivery per Stroke 0,15 cm³
Electrics
Operating voltage 24 (20...28) V
Protection 0,75 (slow blow) A
Protection class IP 54
*The stated value is down to the individual application and may extensively
differ in some cases (depending on the lubricant and further conditions).
3. Mounting
1. Separate the housing from the power unit by turning the retai-
ning ring counterclockwise.
2. Turn the cap on the lubricant cartridge counterclockwise and
pull it off .
3. Place the full lubricant cartridge on the
FlexxPump 250 / 400 time (label facing front). Turn the lubricant
cartridge twice clockwise onto the FlexxPump 250 / 400 time.
4. Place the dismantled housing on the FlexxPump 250 / 400 time.
Fasten the housing to the power unit by turning the retaining
ring clockwise.
5. To connect the FlexxPump 250 / 400 time with an external
power supply system add a proper connecting cable to the
electrical interface on the side of the FlexxPump 250 / 400 time.
DANGER
Damaged or flawed electrical connections or unlicensed hot
components lead to heavy injuries or even death.
4. Commissioning
1. Mechanical fastening
Fix the FlexxPump 250 / 400 time mechanically. Pay particular atten-
tion to the maximum tightening torques permissible!
2. Electrical connection
3. Power on
4. Execute FIL function
5. Hydraulic connection
Connect the consumer hydraulically to the FlexxPump 250 / 400
time. If you connect tubes to the FlexxPump 250 / 400 time make
sure that tubes and connectors are installed tightly, cleanly and
correctly.
 Ideally, use tubes prelled with the appropriate lubricant.
6. Check settings on the FlexxPump 250 / 400 time
Check the required values for the lubrication point at the factory set-
tings of the FlexxPump 250 / 400 time and adjust them if necessary.
Factory settings: operating mode=hour mode.
5. Operation and settings
Two operating modes can be selected.
Thehourmode -h- allowssettingthenumberofcycles(c)withinabreak
time (h) in hours. The cycles are evenly distributed over the break time.
Breaktimesbetween1...240hour(s)andcycles between 1...30 can be set.
The empty time mode Et allows the emptying time of the cartridge
to be set in months. Emptying times between 1...36 month(s) and cyc-
les (c) between 1...30 can be set.
The graphic above illustrates the unchangeable basic flowchart of the
the FlexxPump 250 / 400 time menu navigation as well as the options
for branching to submenus.
 The FlexxPump 250 / 400 time can be switched on and off at seve-
ral points in the menu navigation.
 The INF-menu provides you with an informative overview of the
current the FlexxPump settings.
 The SET menu allows you to make change the operating mode
and to adjust the size of the cartridge.
 The RUN menu allows you to manually trigger a single dispense at
the FlexxPump 250 / 400 time.
 The PRO menu allows you to make changes to the the FlexxPump
250 / 400 time settings - and thus to its dispensing behavior.
 The FIL menu allows you to manually trigger a xed number of
dispenses at the FlexxPump 250 / 400 time.
0
5
4
2
3
6
8
1
9
10
7
Display in LCD Description
---- Received control signal longer than 15 seconds
Errors
E1 Error E1 (empty cartridge)
E2 Error E2 (overload / overpressure)
E3 Error E3 (undervoltage)
E4 Error E4 (fatal error)
Submenus
INF INF-Menü
n41 Firmware version of the FlexxPump 250 / 400 time
h03 Currently set value of break time h
c01 Currently set value of number of strokes c
06 Currently set value of emptying time Et
SET SET-Menü
-h- Operating mode: hour mode
Et Operating mode: empty time mode
250/400 Adjustment of the cartridge size
5.2 Menu and LCD messages
5.1 Default settings, hour mode -h-
Break time h = 3 The break time is 3 hours.
No. of cycles c = 1 The number of cycles is one (1) stroke during
break time.

Other manuals for FlexxPump 250

2

This manual suits for next models

1

Other DLS Lubrication System manuals

DLS FlexxPump 125 B User manual

DLS

DLS FlexxPump 125 B User manual

DLS DLS-47 Series User manual

DLS

DLS DLS-47 Series User manual

DLS FlexxPump 250 B User manual

DLS

DLS FlexxPump 250 B User manual

DLS FlexxPump 1500 User manual

DLS

DLS FlexxPump 1500 User manual

DLS 125 User manual

DLS

DLS 125 User manual

DLS 125 User manual

DLS

DLS 125 User manual

DLS FlexxPump 250 User manual

DLS

DLS FlexxPump 250 User manual

DLS FlexxPump 250 B User manual

DLS

DLS FlexxPump 250 B User manual

Popular Lubrication System manuals by other brands

Bijur Delimon MultiPort quick start guide

Bijur Delimon

Bijur Delimon MultiPort quick start guide

Trico Opto-Matic 30078 instructions

Trico

Trico Opto-Matic 30078 instructions

Perma NOVA 125 operating instructions

Perma

Perma NOVA 125 operating instructions

BEROTEC Mofessor manual

BEROTEC

BEROTEC Mofessor manual

Lincoln QLS 421 Installation and operating instructions

Lincoln

Lincoln QLS 421 Installation and operating instructions

Timken M-Power 300 installation instructions

Timken

Timken M-Power 300 installation instructions

Perma Classic 120 operating instructions

Perma

Perma Classic 120 operating instructions

Timken C-POWER Series operating manual

Timken

Timken C-POWER Series operating manual

Pulsarlube 1250RO-2 installation instructions

Pulsarlube

Pulsarlube 1250RO-2 installation instructions

LubriMist JD Installation and operating manual

LubriMist

LubriMist JD Installation and operating manual

Bijur Delimon V5 Assemblies

Bijur Delimon

Bijur Delimon V5 Assemblies

Wilkerson B18 Installation & service instructions

Wilkerson

Wilkerson B18 Installation & service instructions

Lincoln SKF 84803 User and maintenance instructions

Lincoln

Lincoln SKF 84803 User and maintenance instructions

Graco FIRE-BALL Series Instructions-parts list

Graco

Graco FIRE-BALL Series Instructions-parts list

iSHAN YGL-L Operation manual

iSHAN

iSHAN YGL-L Operation manual

Lincoln QLS 301 user manual

Lincoln

Lincoln QLS 301 user manual

ABNOX 4327000 instruction manual

ABNOX

ABNOX 4327000 instruction manual

Groeneveld BreakAlube-3 General manual

Groeneveld

Groeneveld BreakAlube-3 General manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.