Enerdrive Inverter-Charger Owners Manual (Rev. 1.0)Page 14
Unit Setting Function Chart
Inverter
ON : Use as Inverter only. No By-Pass functions.
ON : (Default): Buzzer is enabled. Unit buzzes whenWarning or Error occurs.
OFF : Buzzer is disabled. Unit does not buzz whenWarning and Error occur.
ON : (Default): AC Charger is enabled. Charge battery when AC Input is available.
Li : (Default): Lithium Battery, default Bulk Charge/FloatVoltage is 14.4V/13.5V*
12V/3000W Models: Selectable Ranges 25A, 40A, 60A, 80A, 100A (Default 100A).
12V/3000W Models: Selectable Range: 20A, 15A, 10A, 5A, 2A (Default 10A).
12V/2000W Models: Selectable Ranges 10A, 20A, 40A, 60A, 80A (Default 80A).
12V/2000W Models: Selectable Range: 15A, 10A, 8A, 4A, 2A (Default 8A).
24V/3000W Models: Selectable Ranges 10A, 20A, 30A, 40A, 50A (Default 50A).
24V/3000W Models: Selectable Range: 8A, 6A, 5A, 3A, 2A (Default 5A).
24V/2000W Models: Selectable Ranges 5A, 10A, 20A, 30A, 40A (Default 40A).
24V/2000W Models: Selectable Range: 6A, 5A, 4A, 3A, 2A (Default 4A).
AGM : AGM Battery, default Bulk Charge/Float Voltage is 14.3V/13.4V*
FLd : Flooded Battery, default Bulk Charge/FloatVoltage is 14.4V/13.5V*
HI : High <35°C
(Default): Normal 15 -
35°C : Low < 15°C
Bulk/Absorption voltage is based on the battery type chosen. All battery types have selectable ranges
of 13.8 – 14.8V*. (Default on Li Battery is 14.4V*)
Float voltage is based on the battery type chosen. All battery types have selectable
ranges of 13.0 – 14.0V*. (Default on Li Battery is 13.5V*)
230 Vac Models: Range: 3, 5, 7, 10, 15
(Default 15A).
Select to reset all settings to default
Battery Recharge Voltage Selectable Range: 12.8 to 14.0V (0.1V step)* (Default on
GEL, AGM, Flooded, PGM battery setting is 12.8V* and Li setting is 13.3V).
PGM : Program, default Bulk Charge/FloatVoltage is 13.8V/13.2V*
PSY : : Power Supply Mode, Default Power Supply Voltage 13.8V*
OFF : AC Charger is disabled. No battery charging when AC Input is available.
Battery Low Disconnect Voltage selectable ranges is 10.5 - 12.0V (0.1V steps)
*(Default voltage is set to 12.0V*)
Battery LowWarning Voltage selectable ranges is 11.0 - 12.5V (0.1V step)*
(Default voltage is set to 12.5V*)
Battery Low RecoveryVoltage selectable ranges is 11.5 - 13.0V (0.1V step)
*(Default voltage is set to 13.0V*)
OFF : (Default): Continuous AC Output when inverter is ON
10 : Continuous AC Output when inverter is ON and AC load is > 10W
15 : Continuous AC Output when inverter is ON and AC load is > 15W
20 : Continuous AC Output when inverter is ON and AC load is > 20W
25 : Continuous AC Output when inverter is ON and AC load is > 25W
Inverter can be turned ON & OFF with a press of the power button. (AC OUT)
Charger &Transfer Auto Connect when Mains is Connected (Within Range)
Whole Unit can be turned OFF by HOLDING the Power Button for 5-seconds
F01
ATO
Load Sense
Battery Low Disconnect
Battery LowWarning
Battery Low Recovery
Audible Buzzer
AC Charger
Battery Type
Bulk Current
Bulk/Absorption/Voltage
Absorption to Float Current
FloatVoltage
RechargeVoltage
Battery Temperature
AC Input
Source Circuit Breaker
Factory Default
F02
F03
12.0*
F04
12.5*
F05
13.0*
F06
F07
F08
F09
100
F10
14.4*
F11
10
F15
15
F16
F12
13.5*
F13
13.3*
F14
Unit Setting Display Description and Available Setting
*for 24V models all of the voltage values are doubled.