manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. DVS
  6. •
  7. Control Unit
  8. •
  9. DVS EC Reclaim Plus User manual

DVS EC Reclaim Plus User manual

Other DVS Control Unit manuals

DVS FILTER CONTROL User manual

DVS

DVS FILTER CONTROL User manual

DVS EC Reclaim Plus User manual

DVS

DVS EC Reclaim Plus User manual

DVS EC Automatic User manual

DVS

DVS EC Automatic User manual

DVS D103/V2/AUTO User manual

DVS

DVS D103/V2/AUTO User manual

DVS EC Climate Controlled System User manual

DVS

DVS EC Climate Controlled System User manual

DVS EC Automatic User manual

DVS

DVS EC Automatic User manual

DVS EC Climate Controlled User manual

DVS

DVS EC Climate Controlled User manual

DVS EC Automatic User manual

DVS

DVS EC Automatic User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

DVS® EC Reclaim Plus
Enjoy a healthier, more comfortable home
0800 387 387 www.dvs.co.nz
Humidity Sensitive
User Guide
For further assistance please call DVS® on 0800 387 387 or visit www.dvs.co.nz
Useful Tips.
System Performance.
Your DVS® will help to provide a healthier, drier
living environment.
Ventilation, heating (in cooler months) and
cooling (in warmer months) are all keys
to providing a drier, healthier and more
comfortable living environment.
Winter: (or cooler months). Your DVS® is
programmed to supply enough ventilation for
your home based on the size of your home. If
the home is now drier, you may wish to reduce
the level of ventilation using the Fan Tune
adjustment (see page one). The ideal being to
have the minimum level of ventilation while
retaining a drier, healthier home.
If the home is not yet drier, you can increase
the Fan Tune adjustment to ventilate at a
higher level.
Summer: (or warmer months). Experience has
found that increasing the Fan Tune setting
to higher levels provides better ventilation in
warmer months.
If you feel you have system performance issues
e.g. wet windows, turn the system o and call
0800 387 387 so that we can assist with this
issue.
Filters.
Maintenance of the equipment, including
replacement of the air lter(s) with genuine
DVS® lter(s), is required to ensure the
durability and performance of the system for
the warranty period and beyond.
As the serviceable life of the DVS® lter(s) will
vary with location and environmental factors
outside of the control of the Company, Proven
Systems Limited recommends replacing the
lter(s) with a genuine DVS® lter(s) annually.
A message will show on the controller when
your lter(s) are due to be changed
Call us on 0800 387 387 or visit
www.DVS.co.nz to purchase lters.
Five Year Warranty.
DVS® Manufactured and branded products
carry a 5 year on site parts and labour warranty.
The warranty is dated (begins) on the day of
installation and/or supply of the goods.
Non DVS® manufactured and branded products
are not manufactured by the company. Non
DVS® manufactured and branded products
therefore, carry the warranty provided by the
specic product manufacturer.
The warranty covers manufacturing faults in
the product (equipment) and product failure
caused by incorrect installation.
DVS® EC Reclaim Plus Installed on:
Installed by:
Invoice Number:
F6 Carbon MERV12
Filter(s) type and number:
F7 MERV13
Optional features, if
in operation, appear
here.
Displayed on the home screen
House temperature
at the keypad.
Filter change
indication (if it is
due) appears here.
Menu / On / O
Turning the system ON or OFF: Press and hold MENU to turn the system On or O.
Fan Boost: (Activate by holding down for 3 seconds) When in Fan Boost, the system will
operate at maximum speed (max air supply rate) for a set amount of time, and then it will revert
back to condensation control speed.
Standard features:
To access the standard features: Press the MENU button. (This changes the screen to the
rst menu). Then move the highlight by using to select the desired function and press
OK to enter that function. Press the MENU Button at any time to return to the previous screen.
Fan Settings:
Fan Tune: This allows you to adjust the condensation control fan speed (air supply rate)
by +/- 50%. The system operates at this speed constantly unless it is in Fan Boost or has turned
o because of a humid air supply (see Hum. Settings)
Note: Altering the fan settings will alter the behaviour of your system. If performance is reduced,
adjust this setting back to where it was originally set. If unsure please contact our service
department on 0800 387 387.
DVS® EC Reclaim Plus User Guide (Humidity Sensitive)
Humidity Sensor
Phone 0800 387 387 | www.dvs.co.nz
Hum. Settings: For adjusting the sensitivity of the system to an air supply which is more humid
than the air inside the home.
Hum. Settings - Hum. Sens: Sets the level of sensitivity of the system to the supply air being
more humid than the air inside the home. Ranging from OFF, LOW, MED, Hi (high), V Hi (very high).
‘Standard Setting = Hi’
Hum. Settings - Hum. Time: Sets the time the system will allow supply air to be more humid
than the inside air. So; this setting creates a delayed reaction, ranging from Instant, V Hi (15mins),
Hi (30mins), Med (45mins), Low (60mins).
Standard Setting = ‘Instant’
Note: Altering the above Humidity Settings will alter the behavior of your system. If performance
is reduced, adjust this setting back to where it was originally set. If unsure please contact our
service department on 0800387387 before you alter any of the settings.
Utilities:
For access to: Setting the System Clock, turning the Backlight On/O, setting System Timer,
resetting the Filter Timer, viewing Temperature and Humidity graphs and System Diagnostics.
Optional Features:
These include Summer Vent Bypass, Solar Gain and Tempervents (Air Warmers)
To access the optional features (if tted):
Press the MENU button. (This changes the screen to the rst menu) Then move the highlight by
using the arrows to select the desired option and press OK to select that option.
Mode: The way you want the optional feature to be activated.
(Follow the prompts at the bottom of each screen when setting).
Fan Speed: (Summer Vent Bypass and Solar Gain only). The Fan Speed the optional feature will
operate at when it is active.
Remember: Where you leave the highlight, is the mode in which the feature will operate in. If a
feature is currently on (active), it will show on the home screen in red.
State-of-the-
art European
counterow
heat exchanger