manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. DXV
  6. •
  7. Toilet
  8. •
  9. DXV Belshire D22025A101 User manual

DXV Belshire D22025A101 User manual

- 1 -
INSTALLATION INSTRUCTIONS
SAVE FOR FUTURE USE
Product names listed herein are trademarks of AS America, Inc.
© AS America, Inc. 2020 7302408-100 (2/2020)
RECOMMENDED TOOLS AND MATERIALS
Most of the procedures require the use of common tools and materials, which are available from hardware and plumbing
supply stores. It is tessential that the tools and materials be on hand before work is begun.
Thank you for selecting DXV. To ensure this product is installed properly, please read these instructions carefully before you begin.
(Certain installations may require professional help.) Also be sure your installation conforms to local codes.
CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE!
NOTE: Pictures may not exactly define contour of china and components.
!
DXV Belshire™
1-Piece Toilet, Concealed Trapway
Right Height®, Elongated, HET
Model: D22025A101
GasketWax Ring
Regular Screwdriver
10'
Level Flexible Supply Tube
Closet Bolts
Putty Knife
Tape Measure Hacksaw
SealantAdjustable Wrench
a. Close toilet supply valve and ush tank completely. Towel or sponge remaining water from tank and bowl.
b. Disconnect and remove supply line. NOTE: If replacing valve, first shut off main water supply!
c. Remove old mounting hardware, remove toilet and plug oor waste opening to prevent escaping sewer gases.
d. Remove closet bolts from ange and clean away old wax, putty, etc. from base area.
NOTE: Mounting surface must be clean and level before new toilet is installed!
IMPORTANT: Water supply on the wall is required at 2-1/4" or 8" from centerline of the toilet. First suggested position is
hidden behind the toilet. The geometry of the toilet gives space for this installation. The second suggested
position is next to the toilet. Between these two positions, the space for the supply between wall and toilet
is limited to 4-1/2". In this case, check your supply and hose dimensions.
1
2
REMOVE OLD TOILET
ALL INSTALLATION PROCEDURES MUST COMPLY IN STRICT ACCORDANCE WITH APPLICABLE LOCAL
PLUMBING AND BUILDING CODES
In the United States:
DXV
One Centennial Avenue
Piscataway, New Jersey 08855
Attention: Director of Customer Care
For residents of the United States, warranty
information may also be obtained by calling
the following toll free number: (800) 227-2734
www.DXV.com
In Canada:
DXV
5900 Avebury Road
Mississauga, Ontario
L5R 3M3
Canada
Toll Free: 1-800-387-0369
Local: 905-306-1093
Fax: 1-800-395-1498
www.DXV.ca
In Mexico:
DXV
Via Morelos 330
Col. Santa Clara Coatitla
Ecatepec, Estado de México 55540
Toll Free: 01-800-8391200
www.DXV.mx
For rough-in dimensions, see spec page or web site
- 2 -
INSTALL CLOSET BOLTS
Install closet bolts in ange channel
and slide into place parallel to wall.
TIP: Place 2 pieces of masking tape
on oor (as shown) to help with
alignment in step 4.
Apply weight evenly. Do not move
after placement. Water tight seal
may break.
7302408-100 (2/2020)
1
4
6
2
5
3
!
WARNING:
Overtightening of water supply
line nuts could result in breakage
and potential ooding. If the
connection leaks after hand
tightening, replace the supply
line. Do not use any type of
sealant on the water supply
connection.
Use of plumber’s putty,
pipe dope, or any other
type of sealant will void
the warranty.
For seat installation,
see instructions
included with seat.
*
!
CLOSET FLANGE
DRAIN
CENTER LINE
CLOSET BOLTS
VALVE
BODY
ADJUSTABLE
HEIGHT
WATER LEVEL
ADJUSTMENT
ROD
TANK
LEVER
FLUSH
VALVE
TOP ARM
NIPPLE
Diagram 1
PARTS FOR WATER
CONNECTION
(SEE STEP 9)
CONE WASHER
FLAPPER
THREADED
SHANK
SHANK
WASHER
COUPLING NUT
(HAND TIGHT ONLY)
FILL
VALVE
F L O AT
CUP
CRITICAL LEVEL
MARK ("C.L.")
MUST BE
1" ABOVE
OVERFLOW PIPE
REFILL
TUBE
LOCK NUT
CLOSET BOLT
WASHER
NUT
Press
firmly.
WAX RING
7
ADJUSTMENTS
• Adjust water level. Water
level should be adjusted to
level indicated on tank
by adjusting oat cup.
See Step 7 for water level
adjustment method
• If bowl fails to siphon, an
adjustment may be required
with the lift chain. Simply
remove the bead chain
from the retainment clip
and take up slack on the
chain, and reinsert on lift
rod. Make sure the chain
is not too taught.
Turn on water supply.
Submerge the FLOAT CUP
under the water for 30
seconds. Adjust the water
to desired level by turning
WATER LEVEL ADJUSTMENT
ROD and moving FLOAT CUP
up or down.
- 3 -
When cleaning your toilet, wash it with mild, soapy water, rinse thoroughly with clear water and dry with a soft cloth. Avoid
detergents, disinfectants, or cleaning products in aerosol cans. NEVER use abrasive scouring powders or abrasive pads on
your toilet seat. Some bathroom chemicals and cosmetics may damage the seat's nish.
WARNING: Do not use in-tank cleaners. Products containing chlorine (calcium hypochlorite) can seriously damage ttings in
the tank. This damage can cause leakage and property damage.
DXV shall not be responsible or liable for any tank tting damage caused by the use of cleaners containing chlorine (calcium
hypochlorite).
7302408-100 (2/2020)
8CARE AND CLEANING
!
TROUBLESHOOTING
IF FILL VALVE SHUTS OFF BUT CONTINUES TO LEAK SLOWLY, repeat Step 9.
IF FILL VALVE TURNS OFF AND ON DURING PERIODS OF NON-USE, it is a signal you are wasting water because:
• The end of the rell tube is inserted into overow pipe, below water level in tank. Attach rell tube to overow pipe
using "S" clip provided.
• The ush valve is leaking because it's worn, dirty or misaligned with tank ball or apper (replace with a new apper).
IF FILL VALVE WON'T TURN ON OR SHUT OFF or REFILL OF TANK WATER IS SLOW after valve has been in
use for some time, Fluidmaster Model 242 Replacement Seal may be needed.
Go to our website at www.fluidmaster.com for more solutions to toilet problems.
9
LIFT ARM
FIRST
LIFT ARM
FIRST
LIFT ARM
FIRST
IMPORTANT: Always clear sand
and rust from system.
• Make sure water supply is off.
Remove valve TOP by lifting arm
and rotating top and arm 1/8 turn
counterclockwise, pressing down
slightly on cap.
• While holding a container over
the uncapped VALVE to prevent
splashing, turn water supply on
and off a few times. Leave water
supply off.
• Replace TOP by engaging lugs and
rotating 1/8 turn clockwise. MAKE
CERTAIN TIP IS TURNED TO THE
LOCKED POSITION. VALVE MAY
NOT TURN ON IF TOP IS NOT FULLY
TURNED TO THE LOCKED POS
For troubleshooting information please contact:
© 2001 Fluidmaster, Inc.
® Registered trademark of Fluidmaster, Inc.
30800 Rancho Viejo Road
San Juan Capistrano, CA 92675
(949) 728-2000 (800) 631-2011
www.uidmaster.com
NOTE: Pictures are representative and may not exactly depict the flush valve.
Always use quality Fluidmaster repair parts when maintaining your Fluidmaster products. Fluidmaster shall not be responsible or liable for any damages
caused by products used with Fluidmaster valves that were not manufactured by Fluidmaster, Inc.
- 4 -
7302408-100 (2/2020)
TROUBLESHOOTING GUIDE
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Does not ush a. Water supply valve closed.
b. Supply line blocked.
c. Flush valve chain too loose or disconnected.
d. Sand or debris lodged in water control.
a. Open valve and allow water to ll tank.
b. Shut off water supply, disconnect supply line and inspect all
gaskets and washers. Reassemble. Also, see Fluidmaster
maintenance. (see Step 9)
c. Readjust chain length as required.
d. Shut off water supply. Remove cap and clean as per Step 9.
Poor or sluggish ush a. Bowl water level too low.
b. Supply valve partly closed.
c. Partially clogged trapway and/or drain pipe and/
or vent.
d. Supply pressure too low.
a. Check that rell tube is connected to water control and
inserted into tank
overow without being kinked or damaged.
b. Open supply valve fully. Be sure that proper supply tube size
is used.
c. Remove obstruction. Consult a plumber if necessary.
d. Normal supply pressure must be at least 20 psi.
Toilet leaks a. Poor supply line connection.
b. Poor bowl to tank/oor connection.
a. Review Step 6.
b. Review Step 1-5.
Toilet does not shut off a. Flush valve chain too tight, holding ush valve
open.
b. Flush valve seat and/or apper worn or
deformed.
c. Sand or debris lodged in water control.
a. Readjust chain length as needed. Review Step 6.
b. Shut off water supply. Replace ush valve.
c. Shut off water supply. Remove cap and clean per Step 9.
PARTS LIST
PART NUMBER DESCRIPTION
5020A15G.415 Elongated Seat, Canvas White
735225-400.415 Tank Cover, Canvas White
7381914-200.4270A Trip Lever, Satin Brass
7381914-200.2950A Trip Lever, Brushed Nickel
7381914-200.0080A Trip Lever, Platinum Nickel
7381914-200.0020A Trip Lever, Polished Chrome
7381073-4150A Bolt Cap Kit
7381125-400.0070A Universal Inlet Valve
738942-104.0070A Flush Valve Assembly with Flapper
7381043-402.0070A Flapper Assembly

Other DXV Toilet manuals

DXV Belshire D23050A000.415 User manual

DXV

DXV Belshire D23050A000.415 User manual

DXV AT200 Instruction Manual

DXV

DXV AT200 Instruction Manual

DXV AT200 LS SpaLet User manual

DXV

DXV AT200 LS SpaLet User manual

DXV AT200 User manual

DXV

DXV AT200 User manual

DXV AT200 LS SpaLet User manual

DXV

DXV AT200 LS SpaLet User manual

DXV Lowell D22010C104.415 User manual

DXV

DXV Lowell D22010C104.415 User manual

DXV Modulus Right Height D22020A Series User manual

DXV

DXV Modulus Right Height D22020A Series User manual

DXV Modulus Right Height D22020A Series User manual

DXV

DXV Modulus Right Height D22020A Series User manual

DXV Equility D22690A109 User manual

DXV

DXV Equility D22690A109 User manual

DXV AT200 User manual

DXV

DXV AT200 User manual

DXV Wyatt VorMax Right Height Elongated... User manual

DXV

DXV Wyatt VorMax Right Height Elongated... User manual

Popular Toilet manuals by other brands

Kohler SAN RAPHAEL GRANDE K-8688T-TPF installation instructions

Kohler

Kohler SAN RAPHAEL GRANDE K-8688T-TPF installation instructions

Niagara Ecologic 2216TL product manual

Niagara

Niagara Ecologic 2216TL product manual

Mirabelle BRADENTON MIRBD241 installation instructions

Mirabelle

Mirabelle BRADENTON MIRBD241 installation instructions

Cinderella BUILD IN BOX TRAVEL Installation instruction

Cinderella

Cinderella BUILD IN BOX TRAVEL Installation instruction

Dudley Resan Vandal Resistant Urinal Fitting instructions

Dudley

Dudley Resan Vandal Resistant Urinal Fitting instructions

BIOLAN 70570360 Instructions for installation, use and maintenance

BIOLAN

BIOLAN 70570360 Instructions for installation, use and maintenance

American Standard CCAS1880-111A410 quick start guide

American Standard

American Standard CCAS1880-111A410 quick start guide

aidapt VR252 Usage and maintenance instructions

aidapt

aidapt VR252 Usage and maintenance instructions

Mirabelle ALLEDONIA MIRAL241WH installation instructions

Mirabelle

Mirabelle ALLEDONIA MIRAL241WH installation instructions

Woodbridge B0950S Installation and care guide

Woodbridge

Woodbridge B0950S Installation and care guide

DURAVIT SensoWash Classic 613000 01 2 00 4300 Mounting instructions

DURAVIT

DURAVIT SensoWash Classic 613000 01 2 00 4300 Mounting instructions

EcoLet 25e owner's manual

EcoLet

EcoLet 25e owner's manual

Raritan Marine Elegance 241E Installation and maintenance instructions

Raritan

Raritan Marine Elegance 241E Installation and maintenance instructions

Schon TL-7522HC-W installation instructions

Schon

Schon TL-7522HC-W installation instructions

Gustavsberg NORDIC 3 installation instructions

Gustavsberg

Gustavsberg NORDIC 3 installation instructions

bioBidet BB-600 quick start guide

bioBidet

bioBidet BB-600 quick start guide

Delta C01905 quick start guide

Delta

Delta C01905 quick start guide

Etac Kaskad manual

Etac

Etac Kaskad manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.