manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. E Instruments
  6. •
  7. Measuring Instrument
  8. •
  9. E Instruments BTU900 User manual

E Instruments BTU900 User manual

K800000000EJ 026741 140416
In case the automatic print mode is set then the average analysis
printing start automatically.
Conversely, after the sampling of the third analysis, the average
analysis is shown, so that it can be sent to the printer as
explained in the following.
Note: at this stage turn on the printer (BT / IR) and place it close
to the instrument.
KEYBOARD FUNCTIONS
ON / OFF
Configure / Info Menu
Analysis Menu
WARNING!
Before proceeding with the combustion analysis remember to set the proper fuel and analysis mode through the menu
"SET ANALYSIS", as described in the following:
Using the menu "SET ANALYSIS" you can also set the number of memory in which the acquired data ("Memory")
are stored, as well as set the data of the operator performing the analysis ("Oper.") and finally the model of
receipt to be printed ("Rep.").
Measurements Menu
Print menu
Zoom on Analysis (-)
Select / Modify
Zoom on Analysis (+)
Cancels the modification or
the operation / goes back to
the previous screen
Enters the modify mode
for the selected data /
Confirms the settings
Memory Menu
Draft Menu
E Instruments respects the nature and the environment, therefore provides this quick user guide to
avoid any unwanted waste of paper.
However the complete manual for use and maintenance of the instrument is already available in
the USB stick (included).
Respect your environment: think before printing the full manual on paper.
The magnets in the back of the instrument can damage
credit cards, hard driver, mechanical watches, pacemakers,
defibrillators and other devices proven sensitive to
magnetic fields.
It is recommended to keep the instrument at a distance of
at least 10" away from these devices.
Automatic,
at turn on
Or
►Mem.: 001
Fuel: Natural gas
Oper.:
Rep.: full
Mode: manual
ANALYSIS SETUP
►Natural gas
Propane
L.P.G.
Butane
Diesel oil
▼
FUEL
Automatically
Automatically
saves the first
sample when the
set interval
expires, and so on
until the third
sample.
►RefO2001/1:120 ▼
O24.2
CO29.3
Xair 1.25
Tf 190.1C
Ta 15.4C
ΔT 74.7C
Eff 83.4
Loss16.6
CO 146p
Memory
Analysis
Model
Please wait ...
PRINT REPORT
total
average
001
402 Middletown Blvd, Suite 216, Langhorne, PA 19047 USA
Tel: (215) 750-1212; Fax: (215) 750-1399
[email protected] - www.E-Inst.com
WARNING
Memory location is
already occupied
AUTOMATIC ANALYSIS
QUIT DELETE
Only when the selected
m e m o r y a l r e a d y
contains an analysis.
►RefO2▼
O24.2
CO29.3
Xair 1.25
Tf 190.1C
Ta 15.4C
ΔT 74.7C
Eff 83.4
Loss16.6
CO 146p
Memory 001/1
Draft yes
Smoke yes
CO amb yes
SAVE ANALYSIS
SAVE QUIT
►Print report
Print setup
Print test
PRINT
►RefO2Mem.:001/A ▼
O24.2
CO29.3
Xair 1.25
Tf 190.1C
Ta 15.4C
ΔT 74.7C
Eff 83.4
Loss16.6
CO 146p
Memory
Analysis
Model
PRINT REPORT
total
average
001
PRINT QUIT
Automatically
Features
Flue gas analysis according UNI 10389-1
Calculating of stack heat loss and efficiency
CO environment measurement
Store Smoke value, calculating mean value
Measuring differential pressure
Draught measurement according to UNI 10845
Pressure measurement in the gas supply pipe.
Compliant with: EN 50379-1, EN 50379-2, UNI 10845, UNI 10389-1 COMPLETE MANUAL
ON USB FLASH DRIVE
►Analysis config.
Instrument config.
Information
CONFIG/INFO
It is mandatory to perform
the instrument autozero in
clean air.
WARNING!
During autozero DO NOT
insert the gas probe in the
chimney.
Wait: zeroing instrument
KEEP
PRESSED
FOR 2
SECONDS
WARNING
Do not insert the
gas probe in the
chimney
AUTOZERO STARTED
Once the pressure
zeroing is completed
insert the probe in the
chimney and measure
the draught.
0.0 inH2O
DRAFT
ZERO KEEP
WARNING
Use P+ positive
inlet
DRAFT
Before zeroing the
pressure it is
mandatory to extract
the probe from the
chimney.
0.1 inH2O
DRAFT
ZERO KEEP
AAC PB07
AA SF--A
AAC TA03A
AAC KP01
AA SA05
Smoke
►Ambient CO
Pressure
Tightness test
TC K temperature
▼
MEASUREMENTS
►Print report
Print setup
Print test
PRINT
CO
COmax
AMBIENT CO
START KEEP
PPM
PPM
0
0
►Smoke
Ambient CO
Pressure
Tightness test
TC K temperature
▼
MEASUREMENTS
The CO ambient gas gives a measurement about
the safety of the environment in which the operator
is working. The concentration values can be
associated to the ongoing analysis or printed
through the Print menu.
COmax
AMBIENT CO
START KEEP
PPM
0
►Fuel
Measurement units
O2Reference
Automatic analysis
Condensation
▼
CONFIGURATION
9 x
▲
Alarms
Autozero/Pump
Operator
Report header setup
►Air T
CONFIGURATION
The measured value of the draft may be associated
to the ongoing analysis or directly printed on the
ticket through the "Print" menu.
Save the measurement
2 x
Save the measurement.
2 x
►Print report
Print setup
Print test
PRINT
BTU700
SN:00001 Ver:1.00
►RefO2Auto:001 ▼
O24.2
CO29.3
Xair 1.25
Tf 190.1C
Ta 15.4C
ΔT 74.7C
Eff 83.4
Loss16.6
CO 146p
►Air T
TC K temperature
AIR T
Air T ----- °F
AIR T
Air T
AIR T
---- -
Air T
►TC K temperature
AIR T
68.4°F
AIR T
QUIT KEEP
68.4°F
AIR T
QUIT KEEP

Other manuals for BTU900

1

This manual suits for next models

1

Other E Instruments Measuring Instrument manuals

E Instruments 1100 User manual

E Instruments

E Instruments 1100 User manual

E Instruments Incuba-103 User manual

E Instruments

E Instruments Incuba-103 User manual

E Instruments 4400 User manual

E Instruments

E Instruments 4400 User manual

E Instruments E500 User manual

E Instruments

E Instruments E500 User manual

E Instruments AQ 200 User manual

E Instruments

E Instruments AQ 200 User manual

E Instruments BTU900 User manual

E Instruments

E Instruments BTU900 User manual

E Instruments E500 User manual

E Instruments

E Instruments E500 User manual

E Instruments AQ COMFORT Installation instructions manual

E Instruments

E Instruments AQ COMFORT Installation instructions manual

E Instruments AMI 300 User manual

E Instruments

E Instruments AMI 300 User manual

E Instruments AQ Expert Installation instructions manual

E Instruments

E Instruments AQ Expert Installation instructions manual

E Instruments AQ 100 User manual

E Instruments

E Instruments AQ 100 User manual

E Instruments E8500 Plus Installation instructions manual

E Instruments

E Instruments E8500 Plus Installation instructions manual

E Instruments E4500 User manual

E Instruments

E Instruments E4500 User manual

E Instruments E4500 Installation and operation manual

E Instruments

E Instruments E4500 Installation and operation manual

E Instruments CT 100 O User manual

E Instruments

E Instruments CT 100 O User manual

E Instruments 1500 User manual

E Instruments

E Instruments 1500 User manual

E Instruments 4400-N User manual

E Instruments

E Instruments 4400-N User manual

Popular Measuring Instrument manuals by other brands

FRO­NIUS Smart Meter 50kA-3 operating instructions

FRO­NIUS

FRO­NIUS Smart Meter 50kA-3 operating instructions

SPX FLOW APV DELTA SW4 instruction manual

SPX FLOW

SPX FLOW APV DELTA SW4 instruction manual

ACU-RITE 06034 instruction manual

ACU-RITE

ACU-RITE 06034 instruction manual

Delta OHM HD21ABE manual

Delta OHM

Delta OHM HD21ABE manual

B+K precision 467 Service manual

B+K precision

B+K precision 467 Service manual

EMU PROFESSIONAL II Quick start manual

EMU

EMU PROFESSIONAL II Quick start manual

I-care TA01i User and maintenance manual

I-care

I-care TA01i User and maintenance manual

PerkinElmer Lambda 11 Operation and Parameter Description

PerkinElmer

PerkinElmer Lambda 11 Operation and Parameter Description

Kyoritsu Electrical Instruments Works, Ltd. KEW SNAP 2431 instruction manual

Kyoritsu Electrical Instruments Works, Ltd.

Kyoritsu Electrical Instruments Works, Ltd. KEW SNAP 2431 instruction manual

Unit LM50A user manual

Unit

Unit LM50A user manual

Taramp's VTS 5.1 instruction manual

Taramp's

Taramp's VTS 5.1 instruction manual

ATO T Series instruction manual

ATO

ATO T Series instruction manual

Blackline Safety LONER 900 Getting started

Blackline Safety

Blackline Safety LONER 900 Getting started

AU Tool X91 TPMS user manual

AU Tool

AU Tool X91 TPMS user manual

PerkinElmer LAMBDA 265 Assembly/installation instructions

PerkinElmer

PerkinElmer LAMBDA 265 Assembly/installation instructions

Shineway Tech CAA-100 Series user manual

Shineway Tech

Shineway Tech CAA-100 Series user manual

Applied Instruments Super Buddy 1000.4 East Application note

Applied Instruments

Applied Instruments Super Buddy 1000.4 East Application note

Right On Retinomax 3 instructions

Right On

Right On Retinomax 3 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.