Model Code
F(C)G
Type
FCG= Flow control with reverse flow
check
FG = Flow control without reverse
flow check
Max. controlled flow rate
10 = 1,0 L/min (0.26 USgpm)
16 = 1,6 L/min (0.42 USgpm)
32 = 3,2 L/min (0.85 USgpm)
63 = 6,3 L/min (1.66 USgpm)
120 = 12,0 L/min (3.17 USgpm)
180 = 18,0 L/min (4.75 USgpm)
-3-*** (-A)-*
1 2 4 5
1
2
3
-10
Anti-jump feature (FCG model
option)
Omit when not required and for all FG
models.
Controlled flow adjustment
H = Manual without key lock
K = Manual with key lock
Design number, 10 series
Subject to change. Installation
dimensions remain unchanged for
design numbers 10-19 inclusive.
5
3
4
2
Operating Data
Pressure Limits
Max. pressure, all ports:
FCG-3-***-A models
All other models 160 bar (2320 psi)
315 bar (4500 psi)
Min. pressure differential for effective controlled flow
(port A pressure > port B pressure):
F(C)G-3-10/16/32 models
F(C)G-3- 63/120/180 models 5 bar (75 psi)
8,5 bar (125 psi)
Flow Limits
Recommended controlled flow ranges:
F(C)G-3-10
F(C)G-3-16
F(C)G-3-32
F(C)G-3-63
F(C)G-3-120
F(C)G-3-180
0,015 to 1,0 L/min (0.004 to 0.26 USgpm)
0,015 to 1,6 L/min (0.004 to 0.42 USgpm)
0,025 to 3,2 L/min (0.007 to 0.85 USgpm)
0,025 to 6,3 L/min ( 0.007 to 1.66 USgpm)
0,08 to 12,0 L/min (0.02 to 3.17 USgpm)
0,08 to 18,0 L/min (0.02 to 4.75 USgpm)
Max. recommended reverse flow (FCG model) 30 L/min (7.9 USgpm)
Applications
FG-3 models are for general use in
meter-in, meter-out or bleed-off
applications.
FCG-3-***-*-10 models are for general use
in meter-in or meter-out applications in
which high reverse flow rates can occur.
FCG-3-***-A-10 models are for similar
use in those meter-in applications where
the possibility of transient surges above
the controlled flow rate setting,
whenever flow is first directed to the inlet
port, is undesirable, e.g.
–for feed speed control
–for successive fast approach/feed
sequences (fine machining of
interrupted bores).