E & OE As our policy is one of continuous product development, we reserve the right to alter product details without prior notice. Ei154TL DataSht RevB
Model Ei154TL Heat
Tamper proof rechargeable lithium battery back up
Fixed temperature fast response thermistor type
sensor, range 54°C to 62°C
Test button
Advanced suppression and calibration technology
Interconnectable to other Ei mains powered alarms
Low power cell warning
Kitemarked to BS5446-2:2003
5 year guarantee
Product Description
The Ei154TL is a Heat Alarm that runs on 230V AC
mains power, and has built in tamper proof rechargeable
lithium cells that act as a battery back up in the event of
mains failure. These rechargeable lithium cells are
designed to have a ten year life and outlast the life of the
heat alarm itself, whilst providing up to six months of
heat alarm operation without mains power.
The Ei154TL has advanced features such as the ability
to interconnect up to twelve alarms to allow all alarms to
sound if just one of the interconnected alarms should be
triggered.
The Ei154TL has built in circuitry to aid suppression of
voltage transients and RF interference to further reduce
the chances of false alarms under such conditions.
The Ei154TL heat alarm gives a fire warning when the
temperature at the unit reaches 580C. Heat alarms are
ideal for use in kitchens and garages, where the use of
optical or ionisation alarms would lead to unwanted
nuisance alarms
On escape routes this alarm must be interconnected
with smoke alarms.
Operation
The green indicator will illuminate to show mains
power is present
The red indicator will flash every 40 seconds to
show that the detector has performed an automatic
self test
The red indicator will flash rapidly to show an alarm
condition for the smoke detector
The “Test” button will perform a unit self test and
sound the horn
When interconnected to other Ei mains powered
alarms, an alarm on one detector will trigger all other
interconnected alarms within one second (only the
triggered alarm will flash a red indicator)
The heat detector will emit a beep every 40 seconds
to indicate that the battery back up is depleted and
needs recharging
MAINS POWERED 230V~
Rechargeable Battery Back-Up
Shannon Free Zone, Shannon, Co. Clare, Ireland.
Ph.+353 61 471277 Fx.+353 61 471053
Email. eielectronics@eiltd.ie
Web: www.eielectronics.com
E & OE As our policy is one of continuous product development, we reserve the right to alter product details without prior notice. Ei154TL DataSht RevB
Model Ei154TL Heat
Installation & Placement
Wiring for Interconnected Alarms
Be very careful about correctly wiring the alarms as mixing Live and Neutral
will blow/damage interconnected alarms.
Alarms should be placed in accordance with the general guidelines shown in
the diagram above. These recommendations are based on the problem of
areas of “dead air” close to corners of rooms and apexes of ceilings, which
could result in the prevention of smoke reaching the smoke detector
Please consult instruction booklet for specific installation details
Important Precaution:
Do not install the actual smoke/heat
alarm itself in new or renovated
buildings until all work is completed
(including floor coverings) and the
building has been fully cleaned.
The wiring can be installed when
appropriate. (Excessive dust and
debris from building work can
contaminate the smoke chamber
and cause problems, and it will also
invalidate the guarantee). If it must
be installed, cover it completely,
particularly around the edges, with
a dust cover (eg. a plastic bag),
until all cleaning is finished..
Connect wires to the unit as in
wiring diagram. All wiring must
comply with local codes.
Technical Specification
Sensor Thermistor
Sensitivity: Complies with BS 5446 Part 2:
2003
Source: Contains no radioactive material
Airspeed: Essentially immune to the effect
of airspeed.
Button Test: Simulates the effect of heat and
checks electronics and horn.
Supply Voltage: 230V AC
Battery back up: Rechargeable lithium cells
Power-On Indicator: Continuous green LED
Alarm: Electronic Piezoelectric horn
in unit
Alarm Sound Output: 85dB (minimum) at 3m
Alarm Status: Red LED flashes every second on
unit sensing heat
Temperature Range: 0° to 40°C
Humidity Range: 15% to 95% Relative Humidity
Interconnect: Up to 12 interconnected
Ei150/151TL/151TLR/154TL/155/1
56TL/156TLR smoke or heat
alarms, along with an EI158 relay
base
Fixing: Screw fixings supplied
Plastic material: UL94VO flame retardant
Dimensions: 140mm x 120mm x 58mm.
Weight: 195g
Warranty: 5 year (limited) warranty
Approvals: Kitemarked to BS5446-2:2003, CE
Approved
Specifications are subject to change

Other manuals for Ei154TL

1

Other Ei Electronics Security System manuals

Ei Electronics RadioLINK Ei200MRF User manual

Ei Electronics

Ei Electronics RadioLINK Ei200MRF User manual

Ei Electronics Ei156TL User manual

Ei Electronics

Ei Electronics Ei156TL User manual

Ei Electronics MCP401RC User manual

Ei Electronics

Ei Electronics MCP401RC User manual

Ei Electronics Ei600 Series User manual

Ei Electronics

Ei Electronics Ei600 Series User manual

Ei Electronics Ei Ei168RC User manual

Ei Electronics

Ei Electronics Ei Ei168RC User manual

Ei Electronics Ei208DWRF User manual

Ei Electronics

Ei Electronics Ei208DWRF User manual

Ei Electronics Ei207 Series User manual

Ei Electronics

Ei Electronics Ei207 Series User manual

Ei Electronics RadioLINK Ei171RF User manual

Ei Electronics

Ei Electronics RadioLINK Ei171RF User manual

Ei Electronics RadioLINK Ei168RC User manual

Ei Electronics

Ei Electronics RadioLINK Ei168RC User manual

Ei Electronics Ei 405 User manual

Ei Electronics

Ei Electronics Ei 405 User manual

Ei Electronics RadioLINK Ei262 Manual

Ei Electronics

Ei Electronics RadioLINK Ei262 Manual

Ei Electronics Ei600 Series User manual

Ei Electronics

Ei Electronics Ei600 Series User manual

Ei Electronics RadioLINK Base Smoke & Heat Alarms Ei168 User manual

Ei Electronics

Ei Electronics RadioLINK Base Smoke & Heat Alarms Ei168 User manual

Ei Electronics EI 175 Manual

Ei Electronics

Ei Electronics EI 175 Manual

Popular Security System manuals by other brands

Eclipse EC-P50 user manual

Eclipse

Eclipse EC-P50 user manual

jablotron JA-63A manual

jablotron

jablotron JA-63A manual

Visonic GB-501 PG2 installation instructions

Visonic

Visonic GB-501 PG2 installation instructions

SwissPhone TRIO operating manual

SwissPhone

SwissPhone TRIO operating manual

Pisector GSM-06 user manual

Pisector

Pisector GSM-06 user manual

Google Nest Protect Guide

Google

Google Nest Protect Guide

DSC Power 832 user manual

DSC

DSC Power 832 user manual

Nokia IP60 - Security Appliance user guide

Nokia

Nokia IP60 - Security Appliance user guide

Monroe One-Net SE user manual

Monroe

Monroe One-Net SE user manual

ADEMCO Vista-10P user guide

ADEMCO

ADEMCO Vista-10P user guide

X10 IN62A Setup instructions

X10

X10 IN62A Setup instructions

Aquavx Scout user manual

Aquavx

Aquavx Scout user manual

Vimar 6260.16P.02 Installer's guide

Vimar

Vimar 6260.16P.02 Installer's guide

Visonic POWERMAXEXPRESS - Installer's guide

Visonic

Visonic POWERMAXEXPRESS - Installer's guide

Alexor PC9155-433/868 installation guide

Alexor

Alexor PC9155-433/868 installation guide

SkyLink SA-001S User instructions

SkyLink

SkyLink SA-001S User instructions

First Alert ReadyGuard-RI quick start guide

First Alert

First Alert ReadyGuard-RI quick start guide

Linear 21st Sentry user guide

Linear

Linear 21st Sentry user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.