Ekinex EK-EA2-TP User manual

1
4-fold pushbutton
Product code: EK-EA2-TP
Other characteristics
• Housing in plastic material
• Wallinstallationinushmountingbox
• Protection degree IP20 (according to EN 60529)
• Classicationclimatic3K5andmechanical3M2(accor-
ding to EN 50491-2)
• Pollution degree 2 (according to IEC 60664-1)
• Weight 40 g (55 g with mounting support)
• Dimensions82x75x35mm(WxHxD)
Technical data
• Powersupply30VdcfromKNXbusline
• Current consumption < 15 mA
• Powerfrombus<360mW
Environmental conditions
• Operating temperature: - 5 ... + 45°C
• Storage temperature: - 25 ... + 55°C
• Transporttemperature:-25...+70°C
• Relative humidity: 95% not condensing
Completion of the pushbutton
Forinstallationandoperationanekinex®pushbuttonmust
becompletedwithaseparateorderof:
• operationelementsconsistingoffoursquareorrectan-
gular rockers;
• onesquareframeoftheekinex®formorankseries.
The metallic support, the xing screws (two pairs), the
protection for construction site and the KNX terminal
blockforconnectionofthebuslinearesuppliedwiththe
device.
KNX device for switching and control of single loads or
groupsofloads.IthastobeusedinKNXinstallationsfor
controlofhomesandbuildings.
Description
Theekinex®4-foldpushbutton(max8functions)isaS-
modeKNXdeviceforon/offswitchingofloads,dimming
oflightingdevices,controllingofmotordrivesorotherpro-
grammableswitchingandcontrolfunctions.Itisequipped
withanintegratedKNXbuscommunicationmoduleandis
designedforwallinstallationonushmountingbox.The
devicehastwoLEDsforeachchannelprogrammablefor
exampleasastatussignalor orientationnightlight.The
pushbuttonhastobecompletedwithfourrockersanda
framethatmustbeorderedseparately.Pushingarocker,
thedevicesendsonthebusatelegram,whichisreceived
andexecutedbyoneormoreKNXactuators.Thedevice
ispoweredbytheKNXbuslinewithaSELVvoltage30
Vdcanddoesnotrequireauxiliarypower.
RFLEKEA2TP
2
1)Pushbuttonwithrectangularrockersandsquareframeofankseries
2)Pushbuttonwithsquarerockersandsquareframeofformseries
1
Datasheet STEKEA2TP_EN
Note. Rockers and frame for the completion of the
device must be ordered separately. For more infor-
mation on materials, colors and nishes available,
see also the ekinex®product catalog or browse
www.ekinex.com
Main functional characteristics
• On/offswitchingofsingleloadsorgroupsofloads
• Dimmingoflightingdevices
• Controlofmotordrives(forrollershutters,blinds,cur-
tains, etc.)
• Recallingandsavingofscenes
• Sending on the bus of values (temperature, bright-
ness, etc.)
• Switchingtoforcedfunctioning(lock)
• Measuring of room temperature and light brightness
through integrated sensors
• Different functions programmable for short pressure /
longpressureofarocker
• Statusfeedbackororientationnightlightthrough2-co-
lorprogrammableLEDs
Three-positions rockers with central neutral position have
to be mounted on the pushbutton. Pushing one side of
a rocker (for example the upper one), the pushbutton
sendsonthebusatelegramforswitchingon,increasing
the brightness of luminaires or raising the blinds, while
pushingtheotherside(forexamplethelowerone),itsen-
dsatelegramforswitchingoff,reducingthebrightnessof
luminairesorloweringtheblinds.Eachchannelisequip-
pedwithLEDswhichcanbefreelyprogrammedasstatus
feedbacksoftheloadsandasorientationnightlight.
i
TP1
S

2
Mounting
ThedevicehasdegreeofprotectionIP20,andistherefo-
resuitableforuseindryinteriorrooms.Theinstallationof
thedevicerequiresthefollowingsteps:
a)xthemetallicsupport(5)withthescrewssupplied(6)
onthewallbox(7)providedwithsuitablexingholes;
b) snap a square frame (2) of the form or ank series,
insertingitfromtherearofthedevice(4);
c)enterthebusterminal,previouslyconnectedtothebus
cablein its slot on the rear side (see also: “Connection
oftheKNXbusline”).Atthispointitisrecommendedto
carryoutthecommissioningofthedevice(seealso“Con-
gurationandcommissioning”)oratleastthedownloadof
the physical address;
d) mounting the device on the metallic support supplied
(5)withthescrews(3).Thecorrectmountingofthedevice
occurswhenthebusterminalislocatedinthelowerpart;
formountingthedevicefollowalsotheindicationTOP(ar-
rowtippointingup)ontherearsideofthedevice.
ESEKEA2TP
REFEKQFTQTP
Switching, display and connection elements
Thedeviceisequippedwithmechanismsforswitching,2
LEDsforeachchannel,aprogrammingLEDandapro-
grammingpushbuttonandaterminalblockforconnection
ofthebusline.
Switching elements
• Pushbutton(2) for switching between thenormal and
programming operating modes
• Mechanisms(4)forindependentswitchingofsingleor
groupofloads(tobecompletedwithsquareorrectan-
gular rockers)
Display elements
• LEDred(1)forindicationoftheactiveoperatingmode
(on=programming,off=normaloperation)
• Green and blue LED freely programmable e.g. for
feedbackstatusandorientationnightlight
Customization of rockers
Therockerscanbecustomizedwithsymbolsandtexts,
formoreinformationseethestandardlibraryontheeki-
nex®catalogorthewebsitewww.ekinex.com.Onrequest
itisalsopossibleacustomizationwithsymbolsandtexts
chosenbythecustomer.
Protection for construction site
Aprotectionforconstructionsiteisincludedinthedelivery
of the device. The protection is made of thermoformed
transparentplasticand avoidsthedirtying ofthedevice
causedbythepaintingofthewalls.Tworeliefsincorre-
spondenceofeachrockerallowtheoperationofthechan-
nelalsowhentheprotectionisappliedonthepushbutton.
If necessary the protection for construction site can be
orderedseparatelywiththecodegiveninthetable.
Product
code
Number
and type of
rockers
Modularity
of rockers Frame
EK-EA2-TP
4square 40x40mm square,formor
ankseries
4 rectangular 80x20mm
Product
code
Wall ush
mounting box
Distance betwe-
en xing holes Support
EK-EA2-TP roundorsquare 60 mm EK-SMQ
Product
code Rockers Construction site
protection
EK-EA2-TP 4squareo4rectangular EK-PPQ
123457
6
1)Rockers(tobeorderedseparately)
2)Screwstofastenthepushbuttononthemetallicsupport
3)Pushbutton4channels
4)Frameoftheseriesformorank(tobeorderedseparately)
5)Metallicsupportformountingwallbox
6)Screwsforxingthesupportonthewallbox
7)Wallbox
Note. Programming pushbutton and LED are only
accessible from the rear side of the device. It is bet-
ter addressing the device before the nal assem-
bly of rockers and frame. Once the addressing has
been carried out, the device conguration can be la-
ter downloaded without pressing the programming
pushbutton.
e)snapthefourrockers(1)onthedevice.
The 4-channel pushbutton can be mounted only on a
round or square wall ush mounting box. If necessary,
themetallicsupportformountingonthewallboxcanalso
beorderedseparatelyusingthecodeshowninthetable.
i

3
DCEKEA2TP
Warning! In order to supply the KNX bus lines use
only KNX bus power supplies (e.g. ekinex EK-AB1-
TP or EK-AG1-TP). The use of other power supplies
can compromise the communication and damage
the devices connected to the bus.
1
2
4
5
3
1) Programming LED
2)Programmingpushbutton
3)ConnectionterminalblockforKNXbusline
4)Seatformountingtherocker(intheexample:squarerocker40x40mm)
5)LightguideforLED
Connection of the KNX bus line
TheconnectionoftheKNXbuslineismadewiththeter-
minalblock(black/red)includedindelivery andinserted
intotheslotofthehousing.
CharacteristicsoftheKNXterminalblock
• springclampingofconductors
• 4seatsforconductorsforeachpolarity
• terminal suitable for KNX bus cable with single-wire
conductorsanddiameterbetween0.6and0.8mm
• recommendedwirestrippingapprox.5mm
• color codication: red = + (positive) bus conductor,
black=-(negative)busconductor
Conguration and commissioning
Conguration and commissioning of the device require
theuseoftheETS®(EngineeringToolSoftware)program
V4orlaterreleases.Theseactivitiesmustbecarriedout
accordingtothedesignofthebuildingautomationsystem
donebyaqualiedplanner.
Conguration
Forthecongurationofthedeviceparametersthecorre-
spondingapplicationprogramorthewholeekinex®pro-
ductdatabasemustbeloadedintheETSprogram.For
detailedinformationoncongurationoptions,refertothe
applicationmanualofthedeviceavailableonthewebsite
www.ekinex.com
Warning! The electrical connection of the device
can be carried out only by qualied personnel. The
incorrect installation may result in electric shock or
re. Before making the electrical connections, make
sure the power supply has been turned off.
ELEKEA2TP
+
-
Bus
KNX
82
75
35
29 6
53
DQEKEA2TP
!
!
Product
code
Application program
(## = release)
Communica-
tion objects
(nr. max)
Group
adresses
(nr. max)
EK-EA2-TP
APEKEA2TP##.knxprod
156 254
Note. The conguration and commissioning of KNX
devices require specialized skills. To acquire these
skills, you should attend the workshops at KNX cer-
tied training centers.
i
Commissioning
Forcommissioningthedevicethefollowingactivitiesare
required:
• maketheelectricalconnectionsasdescribedabove;
• turnonthebuspowersupply;
• switch the device operation to the programming mode
by pressing the programming pushbutton located on
therearsideofthehousing.Inthismodeofoperation,
the programming LED is turned on;
• download into the device the physical address and the
congurationwiththeETS®program.
At the end of the download the operation of the device
automatically returns to normal mode; in this mode the
programming LED is turned off. Now the bus device is
programmedandreadyforuse.
Dimensions [mm]

4
Disposal
Attheendofitsusefullifetheproduct
describedinthisdatasheetisclassied
aswastefromelectronicequipmentin
accordance with the European Direc-
tive 2002/96/EC (WEEE), and cannot
bedisposedtogetherwiththemunici-
palundifferentiatedsolidwaste.
Documentation
ThisdatasheetreferstothereleaseA1.0oftheekinex®
deviceEK-EA2-TP,andisavailablefordownloadatwww.
ekinex.comasaPDF(PortableDataFormat)le.
File name Device release Updating
STEKEA2TP_EN.pdf A1.0 03/2014
Warnings
• Installation, electrical connection, conguration and
commissioningofthedevicecanonlybecarriedoutby
qualied personnel in compliance with the applicable
technicalstandardsandlawsoftherespectivecountri-
es
• Openingthe housingof thedevice causes theimme-
diateendofthewarrantyperiod
• Incaseoftampering,thecompliancewiththeessential
requirementsoftheapplicabledirectives,forwhichthe
devicehasbeencertied,isnolongerguaranteed
• ekinex®KNXdefectivedevicesmustbereturnedtothe
manufactureratthefollowingaddress:SBSS.p.A.Via
Circonvallaziones/n,I-28010Miasino(NO)Italy
Other information
• This datasheet is aimed at installers, system integra-
tors and planners
• Forfurtherinformationontheproduct,pleasecontact
the ekinex®technical support at the e-mail address:
[email protected]orvisitthewebsitewww.ekinex.
com
• ekinex®isaregisteredtrademarkofSBSS.p.A.
• KNX®and ETS®areregisteredtrademarksofKNXAs-
sociationcvba,Brussels
© SBS S.p.A. 2014. The company reserves the right to make changes to
this documentation without notice.
Warning! Incorrect disposal of this product may
cause serious damage to the environment and hu-
man health. Please be informed about the correct
disposal procedures for waste collecting and pro-
cessing provided by local authorities.
Marks
• KNX
• CE:thedevicecomplieswiththeLowVoltageDirecti-
ve(2006/95/EC)andtheElectromagneticCompatibility
Directive(2004/108/EC).Testscarriedoutaccordingto
EN 50491-5-1:2010, EN 50491-5-2:2010
Maintenance
Thedeviceismaintenance-free.Tocleanuseadrycloth.
Itmustbeavoidedtheuseofsolventsorotheraggressive
substances.
!
Other Ekinex Control Unit manuals
Popular Control Unit manuals by other brands

oventrop
oventrop Cocon 2TZ Installation and operating instructions

turck
turck TBPN-L1-FDIO1-2IOL user manual

Honeywell
Honeywell L5000-Wi-Fi installation guide

Graco
Graco Compact Dyna-Star 25P686 instructions

Data Translation
Data Translation DT9847 Series user manual

ICP DAS USA
ICP DAS USA MDC-700 Series quick start

Optimus
Optimus AV-4 Installation and operating instructions

SEW-Eurodrive
SEW-Eurodrive MOVITRAC LT Series operating instructions

Allen-Bradley
Allen-Bradley 1785-KE user manual

i3-TECHNOLOGIES
i3-TECHNOLOGIES iMO-LEARN - MDM user manual

ESBE
ESBE CRA110 series manual

Isenberg
Isenberg TVH.4501 installation manual