All disclosures, notices and warranty conditions are being written on EKWB website. Please check terms of use. Revision 2.0. Released on 4th of April, 2018.
STEP 4: CONNECTING WATERBLOCK
Carefully identify the direction of the flow in your circuit. For the EK-VGA Supremacy series water block to operate properly it is mandatory to use the dedicated
INLET/OUTLET openings as shown on picture below. To ensure that the tubes are securely attached to the barb/fittings, please use hose clamps or an appropriate substitute.
ADDITIONAL MOUNTING PLATE OVERVIEW
This product comes with additional mounting plates which even further expand the compatibility of EK-VGA Supremacy series water block. Please consult EK Cooling
Configurator at http://www.coolingconfigurator.com for detailed compatibility list. Please note that due to the shear size of EK-VGA Supremacy the water block needs to be
rotated 45° (in any direction) when using Mounting plate VGA Supremacy HD6770, furthermore it uses only two mounting holes.
Please follow STEP 1 on how to disassemble the EK-VGA Supremacy HWBOT Edition water block and install alternative mounting plate! Use enclosed Allen Key 2mm
Mounting plate VGA Supremacy GF560
Mounting plate VGA Supremacy GF2x0
Mounting plate VGA Supremacy HD6770
(this row is intentionally left blank)
VERY IMPORTANT NOTICE: Once the installation is completed, it is a recommended practice to test the cooling circuit for leaks prior to powering up the computer. We
recommend a 24 hour leak test prior to powering up the computer. Do not test the water block using city water pressure. This will rupture the top of the housing and render
the block unusable (and will void your warranty). While all efforts have been made to provide the most comprehensive tutorial possible, EK Water Blocks assumes no liability
expressed or implied for any consequential damage(s) occurring to your equipment as a result of using EK Water Blocks cooling products, either due to errors or omissions on
our part in the above instructions, or due to failure or defect in the EK Water Blocks cooling products.
REQUIRED TOOLS:
philips screwdriver
All chips, marked RED and BLUE, must be
passively cooled. This is an example shown
on GTX 1080 reference design graphics
card. EK suggests users to check their
factory cooling solution and locate the ICs
which are being actively cooled besides the
GPU itself. We recommend applying self-
adhesive heat-sinks on the same IC.
It is important to cool VRM- and RAM IC on
modern high-performance graphics cards!