GB Wired Weather Sensor
SW01-W wind
SWS01-W wind-sun
SWSR01-W wind-sun-rain
Model
SW01-W01-01 wind
SWSR01-W01-01 wind/sun/rain
SWS01-W01-01 wind/sun
Coding: EasywaveSens
Power supply: 230 V AC ~ 50 Hz
Connected load: 4 VA
Degree of protection: IP44
Class of protection: II
Data line: max. 25m
Operating temperature: -25 °C bis +55 °C
Measuring ranges:
- wind 3 km/h to 50 km/h
- light intensity 1 lx to100 klx
Dimensions (BxLxH):
- sensor 52/131x200x73 mm
- plate 121x52x30 mm
Weight: 260 g
Technical Details
- 1 Sensor SWSR01
- 1 Mounting plate
- 2 Cover caps
- 1 Terminal cover
- 1 Terminal block 2-pin
- 2 Hex bolts 6x40
- 2 Washers
- 2 Dowels SX8
- 1 Hexagon socket screw M6x65
- 1 Lock nut M6
- 2 Pan head screws
- Operating instructions
Scope of Delivery
The weather sensors are only for wire trans-
mission of weather data to the Easywave radio
receivers RCJ05, RCM04 or CM01 for weat-
her-dependent control of awnings.
The manufacturer shall not be liable for any da-
mage caused by improper or non-intended
use!
Intended use
Safety Advice
Before you connect and operate
the device, please read these
operating instructions carefully!
The electrical installation must only be
carried out by a qualified electrician (please
refer to VDE 0100-200 and/or relevant
national regulations).
Repair, maintenance and cleaning
work must only be carried out after
the device has been disconnected
from the mains power supply!
Have faulty device checked by the
manufacturer!
Do not make any unauthorized alterations or
modifications to the device!
Keep the device out of the reach of children.
-
-
-
-
-
Function
The weather sensors continuously detect wind
strength, light intensity and rain data and send
this data via a wired connection to the control
RCM04, RCJ05 or CM01. There, the data is
evaluated and the awning is controlled accor-
dingly.
The „gastronomy function“ integrated in the
SWSR01 also allows the awning to be opened
in rainy weather, contrary to the standard rain
function.
When selecting a location for the device, please
ensure that the light sensor and surface of the
rain sensor are not covered or placed in the
shade. Slipstreams should also be avoided.
We recommend assembling the
weather sensor at a height of above
2.50 m. The installation height may by
no means fall below 1.70 m.
For each installation, please ensure that
the weather sensor is horizontal or is
tilted downwards slightly at the front.
The impeller must always face
downwards.
1. Screw the mounting plate to the installation
site with the screws and dowels.
2. Insert the current and voltage-free mains
cable and the Sensor cable through the
terminal cover from below and clamp the
wires to the terminal block provided.
3. Attach the terminal to the pin connector on the
printed circuit board and securely fix the
terminal cover (see also „Electrical connecti-
on“).
4. Place the sensor between the brackets of the
Mounting plate and attach it with hexagon
socket screw and the lock nut. Attach the
cover caps.
Mains power cable
(not included in supply package)
Warning: the “Electrical connection”
section of this document must be
observed!
Terminal block 2-pin
Cover cap
Mounting plate
Installation
Light sensor
(only SWSR01-W and
SWS01-W)
Rain sensor (only SWSR01-W)
Vane
SWSR01-W
Terminal cover
Sensor connection cable (data cable)
max. permitted Line 25 m
(not included in supply package)
Fig. 1
UM98546A 0913 GB
Disposal Conformity
Service
Put the packaging material into the
recycling bins for cardboard, paper
and plastics.
Dispose of the waste product via a
collection point for electronic scrap or
via your specialist dealer.
Waste electrical products not be disposed of
with household waste!
This product conforms to the
basic requirements of the
R&TTE Directive 1999/5/EC.
Warranty
Within the statutory warranty period we undertake
to rectify free of charge by repair or replacement
any product defects arising from material or
production faults.
Any unauthorized tampering with, or modifica-
tions to, the product shall render this warranty null
and void.
For use in: EU/CH/FL/IS/N
The Declaration of Conformity can be found on
the Internet at: www.eldat.de
General Advice
If, despite correct handling, faults or malfunctions
occur or if the product was damaged, please
contact the company at the address below:
ELDAT GmbH
Im Gewerbepark 14,
15711 Koenigs Wusterhausen, Germany
Phone: + 49 33 75 / 90 37-0
Fax: + 49 33 75 / 90 37-90
Internet: www.eldat.de E-Mail: [email protected]
The operating voltage is 230 V. The
electricity must be connected to the
permanently fitted installation by an
authorised electrically qualified person.
A safety and isolating device must be provided by
the purchaser for activating the system.
Disconnect the power supply cable from the
mains power supply before starting the
installation work.
(see
Fig. 1).
A weatherproof and UV-resistant connection
cable and data cable must be used.
The connection cables and the data cable
cross section must completely seal off the
lead-through opening in the connector
cover.
1. Place the terminal block with the attached
cables onto the pins connector on the printed
circuit board.
2. Snap the terminal cover onto the lower
section of the sensor housing and screw it
tight with the pan head screws provided
Mains connection: N L
Sensor connection: S- S+
Electrical connection
Make / interrupt connection to radio
receiver
To enable weather data to be transmitted to the
control, the weather sensor transmission code
must be programmed into the control as follows:
1. Activate the learning mode/delete mode in
the control (refer to the instruction manual for
the control).
2. Give the „prog“ transmit button on the sensor
a short press; the LED will light up. The
transmission code is transmitted to the
control and the connection between the
control and the sensor has been made or
deleted.
3. Set the desired threshold value.
The setting for the threshold value
depends upon the size and type of
awning and on local conditions. Please
take into account the wind resistance
class for your awning!
Set threshold value for wind
Set threshold value for light intensity
(only SWSR01-W and SWS01-W)
The sensor continuously measures wind speeds
between 3 km/h und 50 km/h. Within this range,
the wind value (threshold value) can be selected
individually.
The currently measured value and the threshold
value that has been set are transmitted to the
radio receiver at 12-minute intervals. If there is a
significant increase in the wind , the value
measured is transmitted immediately.
The awning is then operated as prescribed by the
control.
The factory setting for this value is 11
km/h.
Turn the hand wheel of the potentiometer until the
desired threshold value is obtained.
(³21%)
The sensor measures the light intensity
periodically within the range of 1 lux to 100klux.
Within this range, the light intensity value
(threshold value) can be selected individually.
The currently measured value and the threshold
value that has been set are transmittted to the
radio receiver at 3-minute intervals.
Turn the hand wheel of the potentiometer until the
desired threshold value is obtained.
If the measured value is above or below the
threshold value, then the awning is operated as
prescribed by the control.
The
factory setting for this value is 10 klux.
Rain detection (only SWSR01-W)
Gastronomy function only SWSR01-W
The rain sensor surface is continuously
monitored. The status is transmitted to the control
every 12 minutes. If the status changes from wet
to dry or vice versa, this information is
immediately transmitted to the radio receiver.
The awning is then operated as prescribed by the
control.
The indirekt heating of the rain sensor surface
allows the surface to dry quickly.
The procedure for switching the „gastronomy
function“ ON/OFF is as follows.
1. Press the „prog“ button until the LED flashes.
2. Press the „prog“ button to switch the
gastronomy function ON or OFF.
3. Finally, press the „prog“ button again until the
LED goes off.
prog
+
_
+
_
3 50
km/h
11
19 27 34
42
Wind speed km/h
1 3 Light air
2 11 Light breeze
3 19 Gentle breeze
4 27 Moderate breeze
5 34 Fresh breeze
6 42 Strong breeze
7 50 High wind
prog
+
_
+
_
1 100k
Lux
10
100 1k
10k
Light intensity in lux
100k Bright sunny day
20k Dull sunny day
10k In the shade in summer
3,5k Dull winter day
prog
Gastronomy function
OFF
ON ...
...
Single flash
Double flash
prog
+
_
+
_
prog
_
10 mA IP43
50Hz
230 V
NL-
S+
S
Transmit
button
RCJ05
RCM04

This manual suits for next models

3

Other Eldat Accessories manuals

Eldat EasyWave SH01 User manual

Eldat

Eldat EasyWave SH01 User manual

Eldat Easywave Neo STH01 User manual

Eldat

Eldat Easywave Neo STH01 User manual

Eldat EasyWave RCP04 User manual

Eldat

Eldat EasyWave RCP04 User manual

Eldat Easywave RCP04E5001-15 User manual

Eldat

Eldat Easywave RCP04E5001-15 User manual

Popular Accessories manuals by other brands

Bellhowell BHDC1A user manual

Bellhowell

Bellhowell BHDC1A user manual

Hi-Spec HSODS instruction manual

Hi-Spec

Hi-Spec HSODS instruction manual

MECNOSUD SB Series Use and maintenance manual

MECNOSUD

MECNOSUD SB Series Use and maintenance manual

INW AquiStar TempHion instruction manual

INW

INW AquiStar TempHion instruction manual

TeraBee TeraRanger Multiflex Installation and operation manual

TeraBee

TeraBee TeraRanger Multiflex Installation and operation manual

Argo ARMONY operating instructions

Argo

Argo ARMONY operating instructions

StarTech.com ST122DVIA user guide

StarTech.com

StarTech.com ST122DVIA user guide

Waterpik Water Flosser WF-03 quick start guide

Waterpik

Waterpik Water Flosser WF-03 quick start guide

MOB MO8602 user manual

MOB

MOB MO8602 user manual

System Sensor B501AP-IV installation instructions

System Sensor

System Sensor B501AP-IV installation instructions

DEWESOFT DS-TACHO-2 Technical reference manual

DEWESOFT

DEWESOFT DS-TACHO-2 Technical reference manual

Trinity 100 QT owner's manual

Trinity

Trinity 100 QT owner's manual

Crivit CEK 29 A1 Operating instructions and safety instructions

Crivit

Crivit CEK 29 A1 Operating instructions and safety instructions

Netview Technologies VUEBELL quick start guide

Netview Technologies

Netview Technologies VUEBELL quick start guide

Emos P5740T quick start guide

Emos

Emos P5740T quick start guide

North Star PVM-1 user manual

North Star

North Star PVM-1 user manual

Crow EDS-3000 Installation instructions and user guide

Crow

Crow EDS-3000 Installation instructions and user guide

Bozz Party cooler BWC31B-1 manual

Bozz

Bozz Party cooler BWC31B-1 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.