Operation: Start-Up
Turn water supply on and inspect for leaks. Fix all leaks before continuing.
Connect plug-end of International Power Cord Sets from the Cooler and Bottle Filler into electrical outlets. Bottle Filler must have electrical
power to dispense water. Be sure to reinstall fuse to the circuit or switch the circuit breaker back to the “ON” position.
WARNING: Exposed electrically energized components. Use extreme caution.
Purge air from all water lines by:
• Depressing button of cooler/fountain.
• Depressing the button at top of the Bottle Filler and verify water dispenses.
• NOTE: Steady stream of water assures all air is removed.
The LCD Bottle Counter on the Bottle Filler should illuminate.
Recheck all water and drain connections with water owing through system. Fix all leaks before continuing.
Once unit tests out, install Lower Panel on Water Cooler. Units are now ready for use.
5.
4.
2.
3.
1.
Operation: Bottle Filler Control Board Set-Up
VERIFY CONTROL BOARD SOFTWARE
To verify the software program of the control board the unit
will need to be shut down and restarted. The chiller (if pres-
ent) does not need to be shut down and restarted.
The unit’s lower panel must be open to access the power
cord and wall outlet.
Shut down the unit by unplugging the power cord from the
wall outlet.
Restart the unit by plugging the power cord back into the
wall outlet.
Upon start up, the bottle count display will show the software
designation of BF12.
Reference the instructions for setting the control board.
ACCESSING THE PROGRAMMING BUTTON
To access the program button remove the top cover of the
Bottle Filler. Remove the two (2) screws holding top cover
to Bottle Filler with a 5/32” (4mm) allen wrench. Remove top
cover. Do not discard mounting screws. They will be needed
to reinstall the top cover after programming operations are
completed. The programming button is located at the top
right side of the unit on the control board.
SETTING RANGE OF THE IR SENSOR WHERE APPLICABLE
Depress the program button for approximately 2 seconds un-
til the display changes then release. The display will change
and scroll through two messages:
“RST FLTR” – Reset Filter Status LED
“SETTINGS” – System Settings Sub Menu
If the program button is not pushed again the display will
scroll through the two messages above for three cycles and
then default back to bottle count and be back in run mode.
When the display changes to “SETTINGS”, depress the but-
ton again. The display will change to show
“RNG SET” - Range set for IR sensor.
“UNIT TYP” - Type of unit (REFRIG or NON-RFRG)
“FLT SIZE” - Select lter capacity
“RST BCNT” - Reset bottle count.
When display shows “RNG SET” push program button
once the display will show current value(can be 1–10)
e.g.“RNG=3”.
Once display shows current value push the program button
to scroll through value of 1 – 10. Select the desired range
setting.
Once range is selected allow approximately 4 seconds to
pass and then the display will go back to bottle counter and
be in run mode.
Test bottle ller by placing bottle or hand in front of sensor to
makesure water is dispensed.
1.
3.
2.
6.
5.
4.
1.
1.
2.
1.
4.
5.
6.
7.
3.
6.
RESETTING BOTTLE COUNT
NOTE: Once the bottle count is reset to zero there is no way to
return to the previous bottle count.
Depress the program button for approximately 2 seconds until the
display changes then release. The display will change and scroll through
two messages:
“RST FLTR” – Reset Filter Status LED
“SETTINGS” – System Settings Sub Menu
If the program button is not pushed again the display will scroll through
the two messages above for three cycles and then default back to bottle
count and be back in run mode.
When the display changes to “SETTINGS”, depress the button again.
The display will change to show:
“RNG SET”- Range set for IR sensor.
“UNIT TYP” - Type of unit (REFRIG or NON-RFRG)
“FLT SIZE” - Select lter capacity
“RST BCNT” - Reset bottle count
If the button is not pushed again the display will scroll through the four
messages above for three cycles and return to run mode.
When display shows “RST BCNT” push program button once the display
will show current value e.g. “0033183”.
Once display shows current value push the program button once more
to reset back to 0. The display will show BTLCT = 0 for approximately 2
seconds and then return to run mode showing 00000000 bottles.
Testing the bottle counter:
REFRIG units: Place bottle or hand in front of sensor for 9.4 seconds to
see bottle counter count 00000001, (This is based on lling a
20 oz (590 ml) bottle).
NON-RFRG units: Place bottle or hand in front of sensor for 6.25 sec-
onds to see bottle counter count 00000001, (This is based on lling a
20 oz (590 ml) bottle).