Eloma Joker B 6-23 Instruction manual

1
Installation and Technical Connections
Combi Steamer
Joker B, Joker C 6-23
Article No. 900646 10/05
Place of Installation:
Follow the local regulations and observe the instructions for
the installation of kitchen and shop equipment.
•It is mandatory to set up the appliance in horizontal position. True up minor
unevenness with the vertically adjustable feet.
yWe recommend to install the ovens on top of original eloma lower
racks/supports or wall brackets. In case of installations on top of worktables,
ensure sufficient stability and load capacity, (weight of an empty oven approx.
100 kg).
The equipment must be secured against tilting and falling down.
yInstall no heat or steam sources (for instance deep fat fryers or cooking kettles)
underneath the oven.
Minimum clearance:
yDistance to walls on right, left and back side at least 50 mm. In case of
installations near to materials that risk burning, observe the instructions of fire
protection.
yAvoid to have any other heat and/or steam sources behind or next to the unit.
If this is impossible, ensure sufficient clearance or provide for appropriate
protection. No heat or humidity must penetrate through the cooling slots into the
unit.
Noise Level :
yThe emission value of the noise is less than 70 dB/A.
Exhaust air Lrg
yA built-in cooling function cools down water and steam of condensation, which then
runs down the drain. It is therefore not imperative, however recommended, to install
the appliance under a ventilation hood.
yIf such a hood is installed, its design and power rates should comply with the
German VDI regulation 2052.
yConnected load 5,9 kW Connected load 3,6 kW
Latent heat emission 3,82 MJ/h 2,33 MJ/h
Sensible heat emission 2,55 MJ/h 1,56 MJ/h

2
Electrical connection EZ + Potential equalisation PE
Do not connect the unit to the mains if it has just been transported from a cold
environment into a warm room. Otherwise condensate may develop inside the combi
steamer which may cause damages.
Wait for about two hours until the unit has reached room temperature.
Electrical connections must be performed by an approved electrician in accordance
with VDE regulations and regulations of the local electricity supply companies.
yAs standard the unit with 5,9 kW is supplied with a connecting cable, length 2 m. In case this
cable has to be replaced for whatever reason, use a cable type H07RN-F according to
German VDE standards.
yThe unit with 3,6 kW is ready for plugging
yNext to the appliance an all-pole electric circuit breaker with a contact opening of at least
3mm has to be provided for on site.
yEvery unit requires its own connection and fuse protection.
yModel B: Upon request the possibility of connection to energy optimising systems is
provided for.
yModel C: The possibility of connection to energy optimising systems is standard.
Connecting data:Standard
Connected load 5,9 kW 3,6 kW
Voltage 400 V 3N AC 230 V AC
Fuse protection 3 x 16 A 1 x 16 A
yRefer always to data given on the type plate.
yThe appliance must be incorporated into the potential equalisation system (ground).
You find the terminal under the indication plate.
Water supply EWk /TWk
Connection to the drinking water supply in accordance with the German standard
DIN 1988, section 4 .
yIn accordance with DVGW instructions (German Gas and Water Standard), the appliance is
intrinsically safe and can be connected to the drinking water supply without additional
preventive measures.
To avoid calcareous deposits, we recommend to install a water softener on the basis of
decarbonizer / osmosis for the steam production, if the water hardness exceeds 6° dH (1,08 mmol/litre).
Physical methods, such as for instance magnetic fields are unsuitable.
Please observe installation and operation instructions for the water softener.
Do not use any connections of galvanized steel or any similar material sensitive to corrosion
between water softener and the unit.
yAs standard, the appliance is equipped with two water supply connections (EWk /TWk), both
must be connected.
ySoft water connection EWk for steam generation and manual humidification.
yHard water connection TWk (cold water) for cooling down the condensed water.
(Warm water results in increased water consumption, hot water would stop cooling down)
yWe recommend to use a pressure-resistant, flexible hose ½ " with R¾" screwing. It should be
DVGW (German Gas and Water Standard) and drinking water approved. Make sure it is long
enough to remove the appliance by approx. 50 cm from its standard position ensuring easy
access for servicing .

3
yInstall on site an easily accessible water shut-off valve for every single unit.
Technical Data: Water pressure min 200 kPa = 2 bar
max 600 kPa = 6 bar
Flow pressure at maximum flow rate
Water hardness: EWk max 6°dH = 1,08 mmol/l (only for soft water)
TWk 0-30° dH = 0 - 5,4 mmol/l
Water temperature: EWk max. 50°C but preferably cold.
TWk cold water
Maximum flow rate: EWk 8 l/h
TWk 30 l/h (shower 4,2 l/min)
Water drain A
Connect drain to the waste water system in accordance with the German standard
DIN 1986, section 1.
yIn accordance with DVGW instructions (German Gas and Water Standard), the appliance is
intrinsically safe and can be connected to the drinking water supply without additional
preventive measures.
yMaterial of drain and air-vent pipe must be steam temperature resistant.
Minimum diameter 40 mm, preferably not longer than 1 m, we recommend high temperature
resistant pipes type HT PA-I 1818 according to the German standard DIN 19560. It is not
permitted to taper the cross-section of the drain.
yMake sure to have a slope of at least 5%.
Technical data: Nominal cross-section: 40 mm
Waste water temperature: 80 °C
Maximum flow rate: 4,8 l/min (with shower)
The appliance is intrinsically safe
and can be connected directly to
the sewer without any further
measures.
Gerät = Appliance
Festanschluss = Fixed connection
Tisch = Table/support
However, if there is a siphon built-in in the sewer, the following
measures are mandatory :
1.
Install at the discharge pipe (fixed
connection) a pressure relief pipe.
Gerät = Appliance
Entlüftungsrohr = Discharge pipe
Tisch= Table/support
Festanschluss = Fixed connection
Siphon eingebaut = Built-in siphon
2.
Or place the discharge pipe into an open funnel, which, however, must not be under the
appliance.

4
Dimensioned sketch Joker B, Joker C 6-23
(Housing dimensions and technical connections of models Joker C, Joker B are identical)
Eloma GmbH
Otto-Hahn-Straße 10
82212 Maisach
Germany
Phone: +49 (0) 8141 395-0
Fax: +49 (0) 8141 395-130
www.eloma.com
EZ
520
30 10
50
30
93
30
EZ
10
EWk
A
PE TWk
Lrg
70
Lrg
80
PE EWk
Lrg
A
Ø40
520
50
165 600
615 65
100
530
665
130
195
10
200 365
435
510
35
09.12.03
eloma Maßskizze 915161
Combi Steamer Joker C 6-23
Lrg Ventilation
A Drain Ø 40
EWk Softened water cold G3/4A
TWk Drinking water cold G3/4A
EZ Current
PE Potential equalisation
Technical amendments are reserved
This manual suits for next models
1
Other Eloma Kitchen Appliance manuals
Popular Kitchen Appliance manuals by other brands

Hamilton Beach
Hamilton Beach Electric Skillet user manual

Aroma
Aroma Hot Froth X-Press AFR-120B instruction manual

Danby
Danby DWC283 owner's manual

Elite Gourmet
Elite Gourmet EG-1500 instruction manual

Pizzeria Pronto
Pizzeria Pronto Pizzacraft CS0115 owner's manual

Euroflex
Euroflex Monster EZ2 AUS instruction manual