www.Fisher.com
Use these instructions to mount a FisherRFIELDVUEt
DVC6200 or DVC2000 digital valve controller on Fisher
585C/585CR size 25 actuators with or without handjack
actuators.
WARNING
Avoid personal injury or property
damage from sudden release of process
pressure or bursting of parts. Before
performing any maintenance operations:
DAlways wear protective clothing,
gloves, and eyewear.
DDo not remove the actuator from
the valve while the valve is still
pressurized.
DDisconnect any operating lines
providing air pressure, electric power, or
a control signal to the actuator. Be sure
the actuator cannot suddenly open or
close the control valve.
DUse bypass valves or completely
shut off the process to isolate the
control valve from process pressure.
Relieve process pressure from both
sides of the control valve.
DVent the pneumatic actuator
loading pressure and relieve any
actuator spring precompression.
DUse lock-out procedures to be sure
that the above measures stay in effect
while you work on the equipment.
DCheck with your process or safety
engineer for any additional measures
that must be taken to protect against
process media.
Refer to figure 2 and the parts list for mounting parts
identification. Refer to the DVC6200 or DVC2000 digital
valve controller instruction manual for digital controller
parts identification. Refer to the appropriate actuator
instruction manual for actuator installation, operation,
maintenance, and parts identification.
1. Isolate the control valve from the process line
pressure and release pressure from both sides of the
valve body. Shut off all pressure lines to the actuator,
releasing all pressure from the actuator. Use lock-out
procedures to be sure that the above measures stay in
effect while you work on the equipment.
WARNING
To avoid personal injury due to the
sudden, uncontrolled movement of
parts, do not loosen the stem connector
cap screws when the stem connector
has spring force applied to it.
2. During the attachment of the connector arm (key 3)
to the valve stem connector it will be necessary to
remove the stem connector cap screws and use the
longer cap screws (key 9). To reassemble the valve
stem connector use plain washer (key 8) and hex nut
(key 7). Install the connector arm (key 3) when
reassembling the valve stem connector.
3. Attach the extension arm (key 6) to the connector
arm using two pan head machine screws (key 4) but do
not tighten. See figure 2 for extension arm orientation.
4. Attach the magnet assembly (key 5) to the
extension arm with two pan head machine screws
(key 4) but do not tighten (the magnet assembly can be
inverted 180_without effect).
5. Attach the mounting bracket assembly (key 1) to the
yoke using the two socket head screws (key 2).
6. Push the cap screws and the O-ring in the mounting
bracket groove and then attach the black plastic
alignment template to the mounting bracket by inserting
the two protruding posts into the mounting holes in the
bracket and simultaneously positioning the magnet
assembly so that it can slide into the channel in the
alignment template. The magnet assembly should be
fully in the alignment template channel so that the
extension arm is contacting the back of the alignment
template but not bending it. Tighten pan head machine
screws (key 4), attaching the extension arm to the
connector arm but do not yet tighten the pan head
machine screws attaching the magnet assembly.
7. For an air-to-extend actuator, slide the magnet
assembly (key 5) so that the bottom marking aligns with
sensor index mark on the alignment template (see
figure 1). The magnet assembly’s top marking is used
for air-to-retract. The mounting bracket may require
vertical repositioning to get the magnet assembly in the
correct location. When the magnet assembly is properly
positioned, remove the alignment template and tighten
the two pan head machine screws (key 4).
8. Attach the digital valve controller to the mounting
bracket and tighten the three hex head cap screws
(key 1b).
Mounting Instructions
D103439X012
May 2010
DVC6200 or DVC2000 Digital Valve
Controller on 585C/585CR Size 25
Actuators with or without Handjack
DVC6200 or DVC2000 Digital Valve
Controller on 585C/585CR Size 25
Actuators with or without Handjack Mounting Instructions
D103439X012
May 2010
2
9. Check the position of the magnet assembly (key 5)
in the channel of the digital valve controller housing and
ensure that it is visually centered between the channel
walls and has adequate clearance with the backside of
the channel (approximately 3 mm).
10. Connect and calibrate the digital valve controller as
described in the instruction manual or quick start guide.
For additional information concerning mounting, setup,
calibration, or maintenance of the DVC6200 or
DVC2000 digital valve controller, refer to the
appropriate instruction manual.
Note
Neither Emerson, Emerson Process
Management, nor any of their affiliated
entities assumes responsibility for the
selection, use or maintenance of any
product. Responsibility for the selection,
use and maintenance of any product
remains with the purchaser and end
user.
2
3
4
5
6
1b
Figure 1. Alignment Template
1a
9
GG03798
Figure 2. Mounting Parts Identification
FIGURE SHOWS MAGNET
ASSEMBLY MARKING ALIGNED
WITH SENSOR INDEX MARK
FOR AIR-TO-EXTEND ACTUATOR
ASSEMBLY MARKING
GE43826
NOTE:
DURING THE COMPLETE STROKE OF THE
ACTUATOR, AT ANY PARTICULAR POSITION, THE
DIGITAL VALVE CONTROLLER HALL SENSOR MUST
REMAIN WITHIN THE MARKING SHOWN ON THE
MAGNET ASSEMBLY.
1c
7
8MAGNET ASSEMBLY
Emerson Process Management
Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Chatham, Kent ME4 4QZ UK
Dubai, United Arab Emirates
Singapore 128461 Singapore
EFisher Controls International LLC 2010; All Rights Reserved
www.Fisher.com
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they
are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or
applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the
designs or specifications of such products at any time without notice. Neither Emerson, Emerson Process Management, nor any of their affiliated
entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of
any product remains solely with the purchaser and end user.
Fisher and FIELDVUE are marks owned by one of the companies in the Emerson Process Management business division of Emerson Electric Co.
Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are
the property of their respective owners.

Other manuals for Fisher FIELDVUE DVC6200 SIS

7

This manual suits for next models

3

Other Emerson Control Unit manuals

Emerson ASCO 290 Series User manual

Emerson

Emerson ASCO 290 Series User manual

Emerson 91 User manual

Emerson

Emerson 91 User manual

Emerson KTM VIRGO E Series Manual

Emerson

Emerson KTM VIRGO E Series Manual

Emerson EIM PCU REV A4 Manual

Emerson

Emerson EIM PCU REV A4 Manual

Emerson ANDERSON GREENWOOD 96A Series Manual

Emerson

Emerson ANDERSON GREENWOOD 96A Series Manual

Emerson ANDERSON GREENWOOD 5910C User manual

Emerson

Emerson ANDERSON GREENWOOD 5910C User manual

Emerson SM-I/O 24V Protected User manual

Emerson

Emerson SM-I/O 24V Protected User manual

Emerson Fisher NPS 8 CHP User manual

Emerson

Emerson Fisher NPS 8 CHP User manual

Emerson Fisher EWD User manual

Emerson

Emerson Fisher EWD User manual

Emerson Fisher V500 User manual

Emerson

Emerson Fisher V500 User manual

Emerson Fisher ACE95 Series User manual

Emerson

Emerson Fisher ACE95 Series User manual

Emerson Varec 5010 Series Owner's manual

Emerson

Emerson Varec 5010 Series Owner's manual

Emerson RAIMONDI User manual

Emerson

Emerson RAIMONDI User manual

Emerson AVENTICS 501 Series User manual

Emerson

Emerson AVENTICS 501 Series User manual

Emerson Crosby HSJ Series Manual

Emerson

Emerson Crosby HSJ Series Manual

Emerson YARWAY 9100 ARC Series Manual

Emerson

Emerson YARWAY 9100 ARC Series Manual

Emerson CROSBY STYLE HC ISOFLEX Guide

Emerson

Emerson CROSBY STYLE HC ISOFLEX Guide

Emerson Anderson Greenwood 400 Series Quick guide

Emerson

Emerson Anderson Greenwood 400 Series Quick guide

Emerson White-Rodgers 764-500 User manual

Emerson

Emerson White-Rodgers 764-500 User manual

Emerson Anderson Greenwood M4TL User manual

Emerson

Emerson Anderson Greenwood M4TL User manual

Emerson Bettis OM13-SCE300 User manual

Emerson

Emerson Bettis OM13-SCE300 User manual

Emerson Rosemount ET410 User manual

Emerson

Emerson Rosemount ET410 User manual

Emerson Fisher 8532 User manual

Emerson

Emerson Fisher 8532 User manual

Emerson Fisher Baumann 24000S User manual

Emerson

Emerson Fisher Baumann 24000S User manual

Popular Control Unit manuals by other brands

SEW-Eurodrive 18978894 operating instructions

SEW-Eurodrive

SEW-Eurodrive 18978894 operating instructions

Joy-it DPS BT manual

Joy-it

Joy-it DPS BT manual

U-Prox Button user manual

U-Prox

U-Prox Button user manual

SMART Embedded Computing COMX-P2020 BSP Installation and use

SMART Embedded Computing

SMART Embedded Computing COMX-P2020 BSP Installation and use

M-system R6-NP1 instruction manual

M-system

M-system R6-NP1 instruction manual

Texas Instruments LM3643EVM user guide

Texas Instruments

Texas Instruments LM3643EVM user guide

Viessmann Vitotrol 350-C operating instructions

Viessmann

Viessmann Vitotrol 350-C operating instructions

Linear DC1957A Demo Manual

Linear

Linear DC1957A Demo Manual

Hayward H-Power HPOW230BDT50 user guide

Hayward

Hayward H-Power HPOW230BDT50 user guide

ETAS ES432.1 user guide

ETAS

ETAS ES432.1 user guide

Alfred ZW2-PRO quick start guide

Alfred

Alfred ZW2-PRO quick start guide

Inge dizzer L Series Assembly instructions

Inge

Inge dizzer L Series Assembly instructions

JED JED T440 manual

JED

JED JED T440 manual

Honeywell NOTIFIER FCM-1 Installation and maintenance instructions

Honeywell

Honeywell NOTIFIER FCM-1 Installation and maintenance instructions

Seeed Grove manual

Seeed

Seeed Grove manual

Graco CSP Series instructions

Graco

Graco CSP Series instructions

Waeco Switch200VTO Installation and operating manual

Waeco

Waeco Switch200VTO Installation and operating manual

Pentair PROSTOP-E Installation and operation manual

Pentair

Pentair PROSTOP-E Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.