manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Emerson
  6. •
  7. Control Unit
  8. •
  9. Emerson Kunkle Valve Series User manual

Emerson Kunkle Valve Series User manual

Other Emerson Control Unit manuals

Emerson ANDERSON GREENWOOD 9300H User manual

Emerson

Emerson ANDERSON GREENWOOD 9300H User manual

Emerson Fisher ME00124272 Configuration guide

Emerson

Emerson Fisher ME00124272 Configuration guide

Emerson Fisher HP User manual

Emerson

Emerson Fisher HP User manual

Emerson YARWAY 60Y Series User manual

Emerson

Emerson YARWAY 60Y Series User manual

Emerson Sempell series User manual

Emerson

Emerson Sempell series User manual

Emerson Fisher Baumann Little Scotty 24000C User manual

Emerson

Emerson Fisher Baumann Little Scotty 24000C User manual

Emerson PENBERTHY N6 Series Manual

Emerson

Emerson PENBERTHY N6 Series Manual

Emerson Fisher 6010 User manual

Emerson

Emerson Fisher 6010 User manual

Emerson Dixell XEC Supercap Wiring diagram

Emerson

Emerson Dixell XEC Supercap Wiring diagram

Emerson Fisher POSI-SEAL A81 User manual

Emerson

Emerson Fisher POSI-SEAL A81 User manual

Emerson Bettis Om3-SCE300 User manual

Emerson

Emerson Bettis Om3-SCE300 User manual

Emerson Rosemount RM5800 User manual

Emerson

Emerson Rosemount RM5800 User manual

Emerson Keystone Figure 320 User manual

Emerson

Emerson Keystone Figure 320 User manual

Emerson numatics E22 User manual

Emerson

Emerson numatics E22 User manual

Emerson Fisher OSE User manual

Emerson

Emerson Fisher OSE User manual

Emerson Fisher NPS 2 CCV-N User manual

Emerson

Emerson Fisher NPS 2 CCV-N User manual

Emerson KEYSTONE FIGURE PCS17 Operation and maintenance manual

Emerson

Emerson KEYSTONE FIGURE PCS17 Operation and maintenance manual

Emerson Anderson Greenwood 400 Series Quick guide

Emerson

Emerson Anderson Greenwood 400 Series Quick guide

Emerson EIM 2000 Series User manual

Emerson

Emerson EIM 2000 Series User manual

Emerson Fisher EU User manual

Emerson

Emerson Fisher EU User manual

Emerson 1805 Series User manual

Emerson

Emerson 1805 Series User manual

Emerson Keystone K-LOK H Series Manual

Emerson

Emerson Keystone K-LOK H Series Manual

Emerson Fisher G101 Series User manual

Emerson

Emerson Fisher G101 Series User manual

Emerson Rosemount Analytical NGA2000 CLD User manual

Emerson

Emerson Rosemount Analytical NGA2000 CLD User manual

Popular Control Unit manuals by other brands

Festo Compact Performance CP-FB6-E Brief description

Festo

Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

Elo TouchSystems

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation MPC3034A user manual

JS Automation

JS Automation MPC3034A user manual

JAUDT SW GII 6406 Series Translation of the original operating instructions

JAUDT

JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum Air Module System manual

Spektrum

Spektrum Air Module System manual

BOC Edwards Q Series instruction manual

BOC Edwards

BOC Edwards Q Series instruction manual

KHADAS BT Magic quick start

KHADAS

KHADAS BT Magic quick start

Etherma eNEXHO-IL Assembly and operating instructions

Etherma

Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations Attenuverter Assembly guide

PMFoundations

PMFoundations Attenuverter Assembly guide

GEA VARIVENT Operating	 instruction

GEA

GEA VARIVENT Operating instruction

Walther Systemtechnik VMS-05 Assembly instructions

Walther Systemtechnik

Walther Systemtechnik VMS-05 Assembly instructions

Altronix LINQ8PD Installation and programming manual

Altronix

Altronix LINQ8PD Installation and programming manual

Eaton Powerware Series user guide

Eaton

Eaton Powerware Series user guide

WAGO 750-407/040-000 manual

WAGO

WAGO 750-407/040-000 manual

Sony CCU-590 Operation manual

Sony

Sony CCU-590 Operation manual

Graco 25D614 instructions

Graco

Graco 25D614 instructions

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Task Force Tips

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Shini SPV-U Series manual

Shini

Shini SPV-U Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

KUNKLE VALVE PRESSURE RELIEF VALVES
INSTALLATION AND OPERATING INSTRUCTIONS
INSTALLATION
Always wear proper safety equipment,
includingsafety glasses and ear protection.
1. Mount the valve in a vertical position so
that the valve body is self-draining. If a
body drain port is provided, make sure it
is open when required by the ASME code.
HANDLING
This pressure relief valve is designed to protect
equipment from overpressure. The valve
should be handled with care, not subjected to
heavy shock loads and protected to prevent
contamination from getting inside. It should
be installed correctly per ASME boiler and
pressure vessel code requirements, where
applicable. Failure to do so could result in
property damage or serious injury to personnel.
When hoisting the valve into position for
installation, care should be exercised so that
lifting straps do not contact the valve lift lever.
Rev. E 05/24/2007
Emerson.com/FinalControl © 2017 Emerson. All Rights Reserved. VCIOM-01873-EN 17/07
3. For threaded valves, to prevent sealing
compound from entering and damaging the
valve, apply a small amount of pipe thread
sealing compound to external threads only.
Do not put any sealing compound on the
first thread or on any internal threads. To
do so may cause the sealing compound to
enter the valve and cause seat leakage.
Do not use the valve body or bonnet for
installing the valve in threaded connections.
Use the wrench flats provided to tighten
the valve to the connecting pipe. Torque the
valve enough to ensure a pressure-tight
seal and do not overtighten. To do so may
causevalveleakage.
4. For flanged valves, use new gaskets and
tighten the mounting studs evenly.
5. Do not paint, lubricate or allow
contaminates to enter or cover the interior
or any working parts of the valve.
6. Remove gag screw (if valve is so equipped)
before system start up.
Do not plug any bonnet vent openings. The
inlet piping should be as short as possible,
with no elbows and equal to or greater
than the size of the pressure relief valve
inlet connection. This will help to limit the
inlet pressure drop to 3% or less when the
valveis relieving.
2. When discharge piping is connected to the
valve outlet, make sure it is self-draining if a
body drain port is not used. The valve should
not be connected to any discharge pipe that
contains pressure before the valve opens or
to any pipe where the pressure build-up is
greater than 10% of the set pressure when
the valve is open and relieving.
Discharge piping, other than a short tailpipe,
must be supported. For steam service,
a drip pan elbow or flexible connection
between the valve and the pipe should be
used to prevent excessive pipe stress, due
tothermal expansion, from being imposed
on the valve body.
PRE-INSTALLATION
Verification of model and service media/capacity/
temperature/pressure limits
Verify the model number on the tag against
the model number of the order. For European
service, verify the 'CE Mark' tag is connected
to the valve. Verify the service media, capacity,
temperature and pressure limits of the valve
against the application. Please note the marked
capacity is based on standard temperature
and pressure conditions and is valid only for
the service media noted on the catalog order
guide. Adjustments to the capacity must be
performed for different temperatures or service
media and are the responsibility of the end user
todetermine.
Before installation these instructions must be read fully and understood
2
WARNING
Removal of the seal wires or any attempt to
adjust, repair or modify this product by non-VR
Certified personnel voids the product guarantee
and may cause serious damage to equipment,
personal injury and death. Kunkle Valve is not
liable for any damage resulting from misuse or
misapplication of its products.
MAINTENANCE
Maintenance should be performed on a
regular basis. An initial inspection interval
of 12 months is recommended. Depending
on the service conditions and the condition
of the valve, the inspection interval may be
decreased or increased. Use only Kunkle parts
for repair. Depending on the local jurisdictional
requirements where the valve is installed,
repairs may have to be made by a repair
facilityholding a VR stamp.
KUNKLE VALVE PRESSURE RELIEF VALVES
INSTALLATION AND OPERATING INSTRUCTIONS
OPERATION
1. Maintain a system operating pressure at
least 5 psig or 10% below the set pressure
of the valve, whichever is greater. Operating
too close to the valve set pressure will
cause seat leakage and will shorten the
time between valve maintenance.
2. Do not use the safety valve as a control
valveto regulate system operating pressure.
Excessive operation will cause the seat to
leak and will require more frequent valve
maintenance.
3. ASME Section I and VIII valves equipped with
lift levers are designed to be operated only
when the system pressure is 75% of set
pressure or greater. ASME Section IV valves
may be operated at any set pressure. When
hand operating the valve, hold it open long
enough to purge any foreign matter from
the seat area. If a cable or wire is attached
to the lift lever for remote actuation, make
sure the direction of pull is the same as it
would be if the lever were pulled directly
byhand.