Emerson SW46 User manual

Other Emerson Control Unit manuals

Emerson PENBERTHY FHS Manual

Emerson

Emerson PENBERTHY FHS Manual

Emerson Bettis TEC2 User manual

Emerson

Emerson Bettis TEC2 User manual

Emerson EXD-U01 User manual

Emerson

Emerson EXD-U01 User manual

Emerson Fisher 92B User manual

Emerson

Emerson Fisher 92B User manual

Emerson OSE Series User manual

Emerson

Emerson OSE Series User manual

Emerson SAPAG 7700 Guide

Emerson

Emerson SAPAG 7700 Guide

Emerson FASANI User manual

Emerson

Emerson FASANI User manual

Emerson 289 Series User manual

Emerson

Emerson 289 Series User manual

Emerson Raimondi User manual

Emerson

Emerson Raimondi User manual

Emerson Fisher Type H800 User manual

Emerson

Emerson Fisher Type H800 User manual

Emerson ANDERSON GREENWOOD 96A Series Manual

Emerson

Emerson ANDERSON GREENWOOD 96A Series Manual

Emerson Rosemount BP20E User manual

Emerson

Emerson Rosemount BP20E User manual

Emerson Anderson Greenwood M4TL User manual

Emerson

Emerson Anderson Greenwood M4TL User manual

Emerson Fisher VS100 Series User manual

Emerson

Emerson Fisher VS100 Series User manual

Emerson Fisher HS User manual

Emerson

Emerson Fisher HS User manual

Emerson Coils ASC3 Series User manual

Emerson

Emerson Coils ASC3 Series User manual

Emerson Clarkson ZP300 User manual

Emerson

Emerson Clarkson ZP300 User manual

Emerson Fisher 122A Series User manual

Emerson

Emerson Fisher 122A Series User manual

Emerson Raimondi HPA 150 Installation and operating instructions

Emerson

Emerson Raimondi HPA 150 Installation and operating instructions

Emerson Fisher EAD User manual

Emerson

Emerson Fisher EAD User manual

Emerson YARWAY 9100 ARC Series Manual

Emerson

Emerson YARWAY 9100 ARC Series Manual

Emerson PACSystems IC695ACC302 User manual

Emerson

Emerson PACSystems IC695ACC302 User manual

Emerson Thermo TCLE Series User manual

Emerson

Emerson Thermo TCLE Series User manual

Emerson Bettis XTE3000 User manual

Emerson

Emerson Bettis XTE3000 User manual

Popular Control Unit manuals by other brands

Festo Compact Performance CP-FB6-E Brief description

Festo

Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

Elo TouchSystems

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation MPC3034A user manual

JS Automation

JS Automation MPC3034A user manual

JAUDT SW GII 6406 Series Translation of the original operating instructions

JAUDT

JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum Air Module System manual

Spektrum

Spektrum Air Module System manual

BOC Edwards Q Series instruction manual

BOC Edwards

BOC Edwards Q Series instruction manual

KHADAS BT Magic quick start

KHADAS

KHADAS BT Magic quick start

Etherma eNEXHO-IL Assembly and operating instructions

Etherma

Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations Attenuverter Assembly guide

PMFoundations

PMFoundations Attenuverter Assembly guide

GEA VARIVENT Operating	 instruction

GEA

GEA VARIVENT Operating instruction

Walther Systemtechnik VMS-05 Assembly instructions

Walther Systemtechnik

Walther Systemtechnik VMS-05 Assembly instructions

Altronix LINQ8PD Installation and programming manual

Altronix

Altronix LINQ8PD Installation and programming manual

Eaton Powerware Series user guide

Eaton

Eaton Powerware Series user guide

WAGO 750-407/040-000 manual

WAGO

WAGO 750-407/040-000 manual

Sony CCU-590 Operation manual

Sony

Sony CCU-590 Operation manual

Graco 25D614 instructions

Graco

Graco 25D614 instructions

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Task Force Tips

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Shini SPV-U Series manual

Shini

Shini SPV-U Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

LIMITED WARRANTY
What The Warranty Covers:
All products covered by this Owner’s Manual are warranted against all defects in workmanship and materials. You must be the
original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
All components are covered by this warranty for one year from the date you purchased your fan control. ANY IMPLIED WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES
IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Company Do To Correct Problems:
Emerson Company will replace a defective Emerson Fan Control at no charge to you. We will ship the repaired product or replacement
to you at no charge, but you are responsible for all costs or removal, reinstallation and shipping of the product to Emerson.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE FAN CONTROL TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR
RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products,
Division of Emerson Company, 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product
with your request.
• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your
Emerson Fan Control should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
This warranty also does not cover any defects, malfunctions or failures caused by:
• Repairs by persons not authorized by Emerson Company,
• Use of parts or accessories not authorized by Emerson Company,
• Mishandling, improper installation, modifications or damage to your fan control while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The ceiling fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties
apply, and no employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson Company.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS
NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages
include but are not limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the
cost of repairing or replacing other property which was damaged if this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may
not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Part No. F40BP72300000 Form No. BP7230 Printed in Taiwan 07/99
4
0
3
2
1
Model No.
SW46
WHITE/IVORY
QUIETSLIDE FAN CONTROL
SINGLE-POLE, 4-SPEED FAN MOTOR CONTROL
MAXIMUM 1.25 AMPS, 120 VAC, 60 HZ
CAUTION: Read all instructions carefully before installation.
Save this Owner's Manual for future reference.
Form No. BP7230 Printed in Taiwan
EMERSON
Air Comfort Products
DIVISION OF EMERSON COMPANY
8100 W. Florissant, St. Louis, MO 63136
SW46 Quietslide Fan
Control Owner's Manual
®
OPERATION
Set the fan on its HIGH speed pull
chain setting. Then use your speed
control to select any of the
4-speeds, plus OFF.
NOTE: The “0” position is OFF.
The four fan speeds are selected
by sliding the bar to the other
four speed positions (“1”, “2”,
“3” and “4”).
IMPORTANT
Always have the fan switch set to
HIGH speed before using the wall
control. To avoid accidental pull
chain use, shorten chain by
cutting it 1” below switch body.
The SW46 Quietslide Fan Control
turns all Emerson Ceiling Fans into
four-speed fans.
32
General
This control is designed to operate
only one ceiling fan, and not an
accessory light kit. This SW46
speed control is rated for 1.2 amps
at 120 volts. To avoid erratic speeds
and possible damage to your ceiling
fan, use this control only with the fan
pull chain switch set to its high
speed setting.
Installation
1. Before disconnecting power,
ensure that the fan is set at the
highest speed.
NOTE: Electric connections
should be in accordance with the
National Electrical Codes and all
Local Codes. Before starting,
disconnect power to the circuit at
the fuse box or circuit breaker
panel.
2. Remove the faceplate and
screws from the existing wall
switch. Pull switch out from wall
outlet box.
3. Disconnect wire from existing fan
wall switch (Figure 1).
4. Slide the SW46 Quietslide Fan
Control in the OFF position (0).
Safety Instructions
WARNING: To avoid fire, shock, and serious personal injury,
follow all instructions carefully.
1.Read your Owner's Manual carefully. Retain Owner’s Manual for
future reference.
2.To avoid possible electrical shock, be sure electricity is turned off
at the main fuse or circuit breaker box before wiring.
3.Make certain no bare wires are exposed outside the wire
connectors.
4.Do not mount speed control near heat producing equipment.
5.All wiring must conform to National and Local Electrical Codes. If
you do not have enough electrical knowledge, have a licensed
electrician install the control.
WARNING: Use of this control with some ceiling fans could result
in fire, shock and serious personal injury. Use this speed control
only with Emerson ceiling fans.
7. Attach the SW46 Quietslide Fan
Control to the wall outlet box
with two 6-32 x 3/4” screws
(provided).
8. Position the faceplate (provided)
onto the speed control. Using the
two 6-32 x 1/4” screws, screw the
faceplate and speed control to
the wall outlet box (Figure 3).
9. Restore power at the main fuse
box or circuit breaker panel.
CAUTION
For fans equipped with built-in
variable speed devices: These
devices must be set at their
MAXIMUM SPEED for proper
operation. Adjustments to their
setting must only be made with
Quietslide in the OFF position.
Changing or sliding these
settings while the fan control is in
operation could damage the
control.
FACEPLATE
SWITCH WALL
OUTLET
BOX
Figure 1
5. Connect one BLACK wire from
the Quietslide to the fan/motor
lead with a wire connector
(provided). (Figure 2.)
6. Connect the other BLACK wire
from the Quietslide to the
120VAC hot wire with a wire
connector (provided).
NOTE: Use wire connectors
(supplied) to secure electrical
connections.
TO NEUTRAL TO FAN MOTOR LOAD
MOTOR LOAD
1.2 AMP MAXIMUM
TO
120VAC
SOURCE
HOT
BLACK
BLACK
4
0
3
2
1
Figure 2
Figure 3
WARNING
!
6-32 x 1/4" SCREW (2)
FACEPLATE
SW46 QUIETSLIDE
SPEED CONTROL
OUTLET BOX
4
0
3
2
1
6-32 x 3/4"
SCREW (2)