manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Emerson
  6. •
  7. Controllers
  8. •
  9. Emerson Fisher 61 Series User manual

Emerson Fisher 61 Series User manual

Introduction
This installation guide provides instructions for
installation, startup and adjustment. To receive a copy
of the instruction manual, contact your local Sales
Office or view a copy at www.fisher.com. For further
information refer to: 61 Series Instruction Manual,
D103233X012. For information on mounting on
pilot-operated regulators, refer to: Type 1098-EGR
Instruction Manual, D100339X012, or Type 99
Instruction Manual, D100260X012.
PED Categories
This product may be used as a safety accessory with
pressure equipment in the following Pressure Equipment
Directive categories. It may also be used outside of the
Pressure Equipment Directive using sound engineering
practice (SEP) per table below. For information on the
current PED revision see Bulletin: D103053X012.
PRODUCT SIZE CATEGORIES FLUID TYPE
1/4 NPT SEP 1
Specifications
Available Configurations
Type 61L: Low pressure pilot for 0.02 to 1.38 bar /
0.25 to 20 psig set points
Type 61LD: Low pressure, narrow proportional
band pilot for 0 to 1.38 bar / 0 to 20 psig
Type 61LE: Low pressure, wide proportional band
pilot for 0.02 to 1.38 bar / 0.25 to 20 psig
Type 61H: high pressure pilot for set pressures
from 0.69 to 4.48 bar / 10 to 65 psig
Type 61HP: high pressure pilot for set pressures
from 1.03 to 20.7 bar / 15 to 300 psig
Maximum Inlet Pressure(1)(2)
Types 61L, 61LE, 61H(3):20.7 bar / 300 psig
Type 61LD: 11 bar / 160 psig
Type 61HP: 41.4 bar / 600 psig
Reduce Pressure Ranges
See Table 1
Proof Test Pressure
All Pressure Retaining Components have been
proof tested per Directive.
Temperature Capabilities(1)
Standard Elastomers: -29 to 66°C / -20 to 150°F
High-Temperature Elastomers: -18 to 149°C /
0 to 300°F, except -18 to 82°C / 0 to 180°F for
water service
Installation
!
WARNING
Only qualied personnel should install
or service a regulator. Regulators
should be installed, operated and
maintained in accordance with
international and applicable codes
and regulations and Emerson Process
Management Regulator Technologies,
Inc. instructions.
If the regulator vents uid or a leak
develops in the system, it indicates that
service is required. Failure to take the
regulator out of service immediately may
create a hazardous condition.
Personal injury, equipment damage or
leakage due to escaping uid or bursting
of pressure-containing parts may result
if this regulator is overpressured or
is installed where service conditions
could exceed the limits given in the
Specications section, or where
conditions exceed any ratings of the
adjacent piping or piping connections.
To avoid such injury or damage, provide
pressure-relieving or pressure-limiting
devices (as required by the appropriate
code, regulation or standard) to prevent
service conditions from exceeding limits.
Additionally, physical damage to the
regulator could result in personal injury
and property damage due to escaping
uid. To avoid such injury and damage,
install the regulator in a safe location.
1. The pressure/temperature limits in this installation guide or any applicable standard limitation should not be exceeded.
2. For stability or overpressure protection, a pressure reducing regulator may be installed upstream of the pilot according to the Installation section.
3. Type 61H pilot used with a 99 Series regulator can handle a maximum inlet pressure of 27.6 bar / 400 psig.
Table 1. Reduced Pressure Ranges
TYPE
PILOT CONTROL SPRING
Reduced Pressure Ranges
bar psig
61LD(1) 0 to 10 mbar
7 to 30 mbar
0 to 4 in. w.c.
3 to 12 in. w.c.
61L,
61LD(1),
61LE(2)
17 mbar to 0.14
69 mbar to 0.35
0.14 to 0.69
0.35 to 1.0
0.69 to 1.4
0.25 to 2
1 to 5
2 to 10
5 to 15
10 to 20
61H 0.69 to 4.5 10 to 65
61HP
1.0 to 3.1
2.4 to 6.9
6.9 to 20.7
15 to 45
35 to 100
100 to 300
1. Type 61LD construction has narrower proportional band than the standard Type 61L Pilot.
2. Type 61LE construction has wider proportional band than the standard Type 61L Pilot.
61 Series
Installation Guide
D103233X014
English – June 2011
Clean out all pipelines before installation of the
regulator and check to be sure the regulator has not
been damaged or has collected foreign material during
shipping. For NPT bodies, apply pipe compound to the
external pipe threads. For anged bodies, use suitable
line gaskets and approved piping and bolting practices.
Install the regulator in any position desired, unless
otherwise specied, but be sure ow through the body
is in the direction indicated by the arrow on the body.
Note
It is important that the regulator be
installed so that the vent hole in the
spring case is unobstructed at all times.
For outdoor installations, the regulator
should be located away from vehicular
tra󰀩c and positioned so that water, ice,
and other foreign materials cannot enter
the spring case through the vent. Avoid
placing the regulator beneath eaves or
downspouts, and be sure it is above the
probable snow level.
Overpressure Protection
The recommended pressure limitations are stamped
on the regulator nameplate. Some type of overpressure
protection is needed if the actual inlet pressure
exceeds the maximum operating outlet pressure rating.
Overpressure protection should also be provided if the
regulator inlet pressure is greater than the safe working
pressure of the downstream equipment.
Regulator operation below the maximum pressure
limitations does not preclude the possibility of damage
from external sources or debris in the line. The
regulator should be inspected for damage after any
overpressure condition.
Startup
The regulator is factory set at approximately
the midpoint of the spring range or the pressure
requested, so an initial adjustment may be required
to give the desired results. With proper installation
completed and relief valves properly adjusted, slowly
open the upstream and downstream shuto󰀨 valves.
Adjustment
To change the outlet pressure, remove the closing
cap or loosen the locknut and turn the adjusting
screw clockwise to increase outlet pressure or
counterclockwise to decrease pressure. Monitor
the outlet pressure with a test gauge during the
adjustment. Replace the closing cap or tighten the
locknut to maintain the desired setting.
Taking Out of Service (Shutdown)
!
WARNING
To avoid personal injury resulting from
sudden release of pressure, isolate
the regulator from all pressure before
attempting disassembly.
Parts List
Key Description
1 Relay Spring Case
2 Relay Valve Body
3 Bottom Cover
4 Relay Yoke
5 Closing Cap Assembly, 61 Series except Type 61HP
6 Adjusting Screw
7 Control Spring
8 Relay Orice, 61 Series except Type 61HP
Fast close and open, open only or close only (Types 61L and
61LD only)
Special orice, fast open only application (Types 61L and 61LD only)
9* Disc Holder Assembly, 61 Series except Type 61HP
10* Bleed Orice, 61 Series except Type 61HP
Capped bleed (Types 61L and 61LD only)
11 Diaphram Nut, 61 Series except Type 61HP
12* O-ring Seal, 61 Series except Type 61HP
13 Relay Spring
14* Upper Relay Diaphragm
15* Lower Relay Diaphragm
16 Upper Relay Head, 61 Series except Type 61HP
Diaphragm Plate, Type 61HP only
17 Lower Relay Head, 61 Series except Type 61HP
18 Spring Seat, 61 Series except Type 61HP
19 Hex Nut
20 Cap Screw, 61 Series except Type 61HP
23 Pipe Plug, Types 61L, 61LD and 61LE only, or
Vent Assembly, Type 61H only
24 Pipe Nipple
25 Filter Assembly
26 Bleed Valve
27 Nameplate
28* Gasket, 61 Series except Type 61HP
30 Pipe Plug, 61 Series except Type 61HP
32 Bleed Orice Cap, Types 61L and 61LD with capped bleed only
33 Handwheel, Types 61L, 61LD and 61LE only
34 Hex Nut
35 Spring Seat
40* O-ring, Types 61L, 61LD and 61LE only
41 Adaptor, Type 61H only
42 Yoke Cap, Type 61HP only
43 Lockwasher, Types 61L, 61LD and 61LE only
44 Machine Screw, Types 61L, 61LD and 61LE only
45 Valve Spring Seat, Type 61HP only
46 Cap Screw, Type 61HP only
47 Machine Screw, Type 61HP only
48 Cap Screw, Type 61HP only
50 Drive Screw
51* Diaphragm Insert, Type 61HP only
52 Lower Yoke Cap, Type 61HP only
53 Bleed Plug, Type 61HP only
*Recommended spare part.
61 Series
2
13 326 11
50
25
15
17
23
19
27
1
28
16
14
24
4
10
12
9
8
18
6
5
7
20
2
TYPES 61L, 61LD AND 61LE PILOT
20A6326
Figure 1. Types 61L, 61LD and 61LE Pilot Assemblies
35
28
1
20A6328 DETAIL OF CAPPED
ADJUSTING SCREW OPTION
1
35
40
34
33
43
28
5
6
44
DETAIL OF HANDWHEEL OPTION
30A6327
30 3
10
11
16
20
12
9
8
17
19
34
27
50
26
13
14
25
4
24
2
15
18
7
1
35
23
6
Figure 2. Type 61H Pilot Assembly
5
28 34
6
35
41
DETAIL OF CAPPED
ADJUSTING SCREW OPTION
30A6330
TYPE 61H PILOT
32A2068
61 Series
3
634
35
48
42
10
45
13
2
52
53
19
46
1
7
50
16
14
4
26
47
15
51
3
27
34A0396
Figure 3. Type 61HP Pilot Assembly
61 Series
Facebook.com/EmersonAutomationSolutions
LinkedIn.com/company/emerson-automation-solutions
Twitter.com/emr_automation
[email protected]
Emerson Automation Solutions
For further information on the current
PED revision see Bulletin: D103053X012
or scan the QR code.
Fisher.com
Americas
McKinney, Texas 75070 USA
T +1 800 558 5853
+1 972 548 3574
Europe
Bologna 40013, Italy
T +39 051 419 0611
Asia Pacic
Singapore 128461, Singapore
T +65 6777 8211
Middle East and Africa
Dubai, United Arab Emirates
T +971 4 811 8100
D103233X014 © 2002, 2019 Emerson Process Management Regulator
Technologies, Inc. All rights reserved. 06/19.
The Emerson logo is a trademark and service mark of Emerson
Electric Co. All other marks are the property of their prospective owners.
Fisher™ is a mark owned by Fisher Controls International LLC, a
business of Emerson Automation Solutions.
The contents of this publication are presented for information purposes
only, and while e󰀨ort has been made to ensure their accuracy, they are
not to be construed as warranties or guarantees, express or implied,
regarding the products or services described herein or their use or
applicability. All sales are governed by our terms and conditions, which
are available on request. We reserve the right to modify or improve the
designs or specications of our products at any time without notice.
Emerson Process Management Regulator Technologies, Inc does not
assume responsibility for the selection, use or maintenance of any
product. Responsibility for proper selection, use and maintenance of any
Emerson Process Management Regulator Technologies, Inc. product
remains solely with the purchaser.

This manual suits for next models

5

Other Emerson Controllers manuals

Emerson Fisher 1052 User guide

Emerson

Emerson Fisher 1052 User guide

Emerson Fisher EZH Series User manual

Emerson

Emerson Fisher EZH Series User manual

Emerson Bettis XTE3000 User manual

Emerson

Emerson Bettis XTE3000 User manual

Emerson Fisher Y696VR Series User manual

Emerson

Emerson Fisher Y696VR Series User manual

Emerson CPHE User manual

Emerson

Emerson CPHE User manual

Emerson Fisher 67C User manual

Emerson

Emerson Fisher 67C User manual

Emerson Bettis RPX Series User manual

Emerson

Emerson Bettis RPX Series User manual

Emerson E300 Series User manual

Emerson

Emerson E300 Series User manual

Emerson Fisher 1305 Series User manual

Emerson

Emerson Fisher 1305 Series User manual

Emerson DIXELL XR60T User manual

Emerson

Emerson DIXELL XR60T User manual

Emerson PACSystems RX3i User manual

Emerson

Emerson PACSystems RX3i User manual

Emerson Fisher S200 Series User manual

Emerson

Emerson Fisher S200 Series User manual

Emerson Fisher 630 Series User manual

Emerson

Emerson Fisher 630 Series User manual

Emerson Rosemount 3490 Series User manual

Emerson

Emerson Rosemount 3490 Series User manual

Emerson Tartarini PRX Series User manual

Emerson

Emerson Tartarini PRX Series User manual

Emerson Bettis M3 User manual

Emerson

Emerson Bettis M3 User manual

Emerson El-O-Matic E Series Instruction manual

Emerson

Emerson El-O-Matic E Series Instruction manual

Emerson Dixell XR03CH Wiring diagram

Emerson

Emerson Dixell XR03CH Wiring diagram

Emerson Fisher Y692 User manual

Emerson

Emerson Fisher Y692 User manual

Emerson Fisher MR95 Series User manual

Emerson

Emerson Fisher MR95 Series User manual

Emerson Dixell XR70CX Wiring diagram

Emerson

Emerson Dixell XR70CX Wiring diagram

Emerson Fisher FIELDVUE DVC6200 SIS User manual

Emerson

Emerson Fisher FIELDVUE DVC6200 SIS User manual

Emerson EC20 Series User manual

Emerson

Emerson EC20 Series User manual

Emerson XWEB300D User manual

Emerson

Emerson XWEB300D User manual

Popular Controllers manuals by other brands

Data Video TPC-700 instruction manual

Data Video

Data Video TPC-700 instruction manual

J-TECH IntelFlex Controller Installation and operator's guide

J-TECH

J-TECH IntelFlex Controller Installation and operator's guide

Cine Gears CG-FC821 user manual

Cine Gears

Cine Gears CG-FC821 user manual

LogiCO2 Grow CO2 Enrichment Controller user manual

LogiCO2

LogiCO2 Grow CO2 Enrichment Controller user manual

Prism Sound DSA-1 Manager Operation manual

Prism Sound

Prism Sound DSA-1 Manager Operation manual

red lion PAX2C installation guide

red lion

red lion PAX2C installation guide

Tolomatic ServoWeld CSW Installation operation & maintenance

Tolomatic

Tolomatic ServoWeld CSW Installation operation & maintenance

Astral Pool Redox Basic EV Next instruction manual

Astral Pool

Astral Pool Redox Basic EV Next instruction manual

digitalview DT-1920-HDMI instructions

digitalview

digitalview DT-1920-HDMI instructions

Alphawave Photonics AWCL-300-6P Series user manual

Alphawave Photonics

Alphawave Photonics AWCL-300-6P Series user manual

Delta 2SPA quick start guide

Delta

Delta 2SPA quick start guide

Black Box 3174/3274 I-Mux Series manual

Black Box

Black Box 3174/3274 I-Mux Series manual

Air Lift AutoPilot V2 installation guide

Air Lift

Air Lift AutoPilot V2 installation guide

Solartech PD600 Operation manual

Solartech

Solartech PD600 Operation manual

Timeguard NSLDD1000 Installation & operating instructions

Timeguard

Timeguard NSLDD1000 Installation & operating instructions

System air E 28 Operator's guide

System air

System air E 28 Operator's guide

BlueBox Eight1080 user manual

BlueBox

BlueBox Eight1080 user manual

Bluesky SOLAR BOOST 2000E Installation and operation manual

Bluesky

Bluesky SOLAR BOOST 2000E Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.